Daikin FDXM25F3V1B, FDXM35F3V1B, FDXM50F3V1B, FDXM60F3V1B, FDXM25F3V1B9 Installer reference guide [hr]

...
Referentni vodič za
instalatera
Split sustav za klimatizaciju
FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B
FDXM25F3V1B9 FDXM35F3V1B9 FDXM50F3V1B9 FDXM60F3V1B9
Referentni vodič za instalatera
Split sustav za klimatizaciju
hrvatski
Sadržaj

1 Opće mjere opreza 2

1.1 O dokumentaciji......................................................................... 2
1.1.1 Značenje upozorenja i simbola ................................... 2
1.2 Za instalatera............................................................................. 3
1.2.1 Općenito...................................................................... 3
1.2.2 Mjesto postavljanja ..................................................... 3
1.2.3 Rashladno sredstvo .................................................... 5
1.2.4 Slana voda.................................................................. 5
1.2.5 Voda............................................................................ 5
1.2.6 Električno .................................................................... 6
2 O dokumentaciji 6
2.1 O ovom dokumentu ................................................................... 6
2.2 Pregled referentnog vodiča za instalatera................................. 7
3 O pakiranju 7
3.1 Pregled: O pakiranju.................................................................. 7
3.2 Unutarnja jedinica...................................................................... 7
3.2.1 Otvaranje pošiljke i rukovanje uređajem..................... 7
3.2.2 Za uklanjanje dodatnog pribora s unutarnje jedinice .. 7
4 O jedinicama i opcijama 7
4.1 Pregled: O jedinicama i opcijama.............................................. 7
4.2 Raspored sustava ..................................................................... 8
4.3 Kombiniranje jedinica i opcija .................................................... 8
4.3.1 Mogućnosti za unutarnju jedinicu................................ 8
5 Priprema 8
5.1 Pregled: Priprema ..................................................................... 8
5.2 Priprema mjesta ugradnje ......................................................... 8
5.2.1 Zahtjevi za mjesto postavljanja unutarnje jedinice...... 8
5.3 Priprema cjevovoda rashladnog sredstva ................................. 9
5.3.1 Zahtjevi za cjevovod rashladnog sredstva.................. 9
5.3.2 Izolacija cjevovoda za rashladno sredstvo.................. 9
5.4 Priprema električnog ožičenja ................................................... 9
5.4.1 O pripremi električnog ožičenja................................... 9
6 Instalacija 10
6.1 Pregled: Postavljanje................................................................. 10
6.2 Montaža unutarnje jedinice ....................................................... 10
6.2.1 Mjere opreza prilikom postavljanja unutarnje jedinice 10
6.2.2 Smjernice kod postavljanja unutarnje jedinice............ 10
6.2.3 Smjernice kod postavljanja kanala.............................. 11
6.2.4 Smjernice pri postavljanju odvodnog cjevovoda......... 11
6.3 Priključivanje cjevovoda rashladnog sredstva........................... 12
6.3.1 O spajanju cjevovoda za rashladno sredstvo ............. 12
6.3.2 Mjere opreza pri spajanju cijevi rashladnog sredstva . 12
6.3.3 Smjernice pri spajanju rashladnog cjevovoda............. 13
6.3.4 Smjernice za savijanje cijevi ....................................... 13
6.3.5 Za proširivanje otvora cijevi ........................................ 13
6.3.6 Za priključivanje cjevovoda rashladnog sredstva na
unutarnju jedinicu........................................................ 14
6.3.7 Za provjeru curenja..................................................... 14
6.4 Spajanje električnog ožičenja.................................................... 14
6.4.1 Više o spajanju električnog ožičenja........................... 14
6.4.2 Mjere opreza za spajanje električnog ožičenja ........... 14
6.4.3 Smjernice za spajanje električnog ožičenja ................ 14
6.4.4 Za spajanje električnog ožičenja unutarnje jedinice.... 15
6.4.5 Specifikacije standardnih komponenti ožičenja .......... 15
7 Konfiguracija 15
7.1 Podešavanje na mjestu ugradnje .............................................. 15
8 Puštanje u pogon 16
8.1 Kontrolni popis prije puštanja u pogon ...................................... 16
8.2 Izvođenje pokusnog rada .......................................................... 16
8.3 Kodovi grešaka kod izvođenja pokusnog rada.......................... 17
9 Predaja korisniku 17 10 Odlaganje na otpad 17 11 Tehnički podaci 17
11.1 Električka shema ........................................................................ 18
12 Rječnik 18
1 Opće mjere opreza

1.1 O dokumentaciji

▪ Izvorna dokumentacija napisana je na engleskom jeziku. Svi ostali
jezici su prijevodi.
▪ Mjere opreza opisane u ovom dokumentu obuhvaćaju vrlo važne
teme, stoga ih pažljivo slijedite.
▪ Postavljanje sustava i sve aktivnosti opisane u priručniku za
postavljanje i u referentnom vodiču za instalatera MORA izvesti ovlašteni instalater.

1.1.1 Značenje upozorenja i simbola

OPASNOST
Označuje situaciju koja rezultira smrću ili teškom ozljedom.
OPASNOST: RIZIK OD STRUJNOG UDARA SA SMRTNIM POSLJEDICAMA
Označuje situaciju koja bi mogla rezultirati strujnim udarom opasnim po život.
OPASNOST: RIZIK OD OPEKLINA
Označuje situaciju koja bi mogla rezultirati opeklinama zbog ekstremno visokih ili niskih temperatura.
OPASNOST: RIZIK OD EKSPLOZIJE
Označuje situaciju koja bi mogla rezultirati eksplozijom.
UPOZORENJE
Označuje situaciju koja bi mogla rezultirati smrću ili teškom ozljedom.
UPOZORENJE: ZAPALJIVI MATERIJAL
OPREZ
Označuje situaciju koja bi mogla rezultirati manjom ili srednje teškom ozljedom.
OBAVIJEST
Označuje situaciju koja bi mogla rezultirati oštećenjem opreme ili imovine.
INFORMACIJE
Označuje korisne savjete ili dodatne informacije.
Simbol Objašnjenje
Prije postavljanja, pročitajte priručnik za postavljanje i rukovanje, i list uputa za ožičenje.
Prije izvođenja radova na održavanju i servisnih zadataka, pročitajte servisni priručnik.
Za više informacija pogledajte referentni vodič za instalatera i korisnika.
Referentni vodič za instalatera
2
FDXM25~60F3V1B(9)
Split sustav za klimatizaciju
4P550955-1 – 2018.07
1 Opće mjere opreza

1.2 Za instalatera

1.2.1 Općenito

Ako NISTE sigurni kako se uređaj instalira ili kako se njime rukuje, obratite se svom zastupniku.
OBAVIJEST
Nepravilno postavljanje ili pričvršćivanje opreme ili dodatnog pribora može izazvati strujni udar, kratki spoj, curenje, požar ili druga oštećenja opreme. Upotrebljavajte samo dodatni pribor, opcionalnu opremu i rezervne dijelove koje je proizvela ili odobrila tvrtka Daikin.
UPOZORENJE
Pobrinite se da postavljanje, testiranje i upotrijebljeni materijali udovoljavaju važećim zakonima (povrh uputa opisanih u dokumentaciji tvrtke Daikin).
OPREZ
Nosite odgovarajuću osobnu zaštitnu opremu (zaštitne rukavice, sigurnosne naočale…) prilikom instalacije, održavanja ili servisiranja sustava.
UPOZORENJE
Rasparajte i bacite plastične vrećice za pakiranje kako se nitko ne bi njima igrao, a pogotovo djeca. Mogući rizik: gušenje.
OPASNOST: RIZIK OD OPEKLINA
▪ Tijekom i odmah nakon rada NE dodirujte cjevovod
rashladnog sredstva ili vode te unutarnje dijelove. Mogli bi biti prevrući ili prehladni. Ostavite ih da se vrate na normalnu temperaturu. Ako ih morate dirati, nosite pritom zaštitne rukavice.
▪ NE dodirujte nikakva rashladna sredstva koja slučajno
isteku.
UPOZORENJE
Poduzmite odgovarajuće mjere kako jedinica ne bi postala sklonište malim životinjama. U kontaktu s električnim dijelovima male životinje mogu izazvati neispravnosti u radu, pojavu dima ili vatre.
OPREZ
NE dirajte ulaz zraka ni aluminijska krilca uređaja.
OBAVIJEST
▪ NE stavljajte nikakve predmete ili opremu na gornju
ploču jedinice.
▪ NE sjedite i NE stojte na jedinici te se NE penjite na
nju.
OBAVIJEST
Radove na vanjskoj jedinici najbolje je obavljati po suhom vremenu kako biste izbjegli prodiranje vode.
U skladu s važećim zakonima proizvodu ćete možda morati priložiti zapisnik koji sadrži barem informacije o održavanju, popravcima, rezultatima testova, razdobljima mirovanja,…
Također, na dostupnom mjestu uz proizvod MORA SE navesti barem sljedeće podatke:
▪ upute za isključivanje sustava u slučaju nužde ▪ naziv i adresu vatrogasaca, policije i bolnice ▪ naziv, adresu te brojeve dnevnih i noćnih telefona za dobivanje
usluge.
U Europi se u standardu EN378 nalaze potrebne smjernice za ovaj zapisnik.

1.2.2 Mjesto postavljanja

▪ Osigurajte dovoljno prostora oko uređaja za servisiranje i strujanje
zraka.
▪ Uvjerite se da mjesto postavljanja može podnijeti težinu uređaja i
vibracije.
▪ Osigurajte dobro prozračivanje prostora. NEMOJTE zapriječiti ni
jedan otvor za provjetravanje.
▪ Pazite da je uređaj niveliran.
Uređaj NE postavljajte na slijedećim mjestima: ▪ U potencijalno eksplozivnom okruženju. ▪ Na mjestima gdje strojevi stvaraju elektromagnetske valove.
Elektromagnetski valovi mogu poremetiti sustav upravljanja i prouzročiti greške u radu opreme.
▪ Na mjestima gdje postoji opasnost od požara zbog curenja
zapaljivih plinova (primjer: razrjeđivač ili benzin), ugljičnih vlakana, zapaljive prašine.
▪ Na mjestima gdje nastaju korozivni plinovi (primjer:
sumporovodik). Korozija bakrenih cijevi ili zavarenih dijelova može prouzročiti istjecanje rashladnog sredstva.
Upute za opremu koja koristi rashladno sredstvo R32
Ako je primjenjivo.
UPOZORENJE
▪ NEMOJTE probušiti ili spaliti. ▪ NEMOJTE koristiti nikakva sredstva za ubrzavanje
odleđivanja ili čišćenje, osim onih koje je preporučio proizvođač.
▪ Imajte na umu da rashladno sredstvo R32 ne sadrži
nikakav miris.
UPOZORENJE
Uređaj treba biti pohranjen tako da se spriječi mehaničko oštećenje i u dobro provjetravanoj prostoriji u kojoj nema stalno uključenih izvora paljenja (primjer: otvoreni plamen, uključeni plinski uređaj ili uključeni električni grijač) i koja ima dolje navedenu veličinu prostora.
OBAVIJEST
▪ NEMOJTE ponovo koristiti spojeve koji su već bili
korišteni.
▪ Spojevi u instalaciji napravljeni između dijelova
rashladnog sustava trebaju biti dostupni u svrhu održavanja.
UPOZORENJE
Sa sigurnošću utvrdite da su instalacija, servisiranje, održavanje i popravci u skladu s uputama iz Daikin i s važećim zakonskim propisima (na primjer s nacionalnim pravilnikom za plinove) i da su ih izvršili samo ovlaštene osobe.
Minimalne udaljenosti instalacije
OBAVIJEST
▪ Cjevovod mora biti zaštićen od fizičkog oštećenja. ▪ Instalacija cjevovoda mora biti minimalne duljine.
FDXM25~60F3V1B(9) Split sustav za klimatizaciju 4P550955-1 – 2018.07
Referentni vodič za instalatera
3
1 Opće mjere opreza
Contains fluorinated greenhouse gases
2
1
1
1
2
2
kg
tCO2eq
1000
GWP × kg
=
=
+
kg
=
kg
=
GWP: xxx
R32
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
1.822.2
2.4
2.6
2.833.2
3.4
3.6
3.844.2
4.4
4.6
4.855.2
5.4
5.6
5.866.2
6.4
6.6
6.877.2
7.4
7.6
7.8
1.843 7.956
8.0
A
min
(m2)
Floor-standing unit
(c)
Wall-mounted unit
(b)
Ceiling-mounted unit
(a)
m (kg)
Ceiling-mounted
unit
(a)
4.6 13.4
4.6 180
4.8 14.6
4.8 196
5.0 15.8
5.0 213
≤1.842
5.2 17.1
≤1.842
5.2 230
1.843 3.64
5.4 18.5
1.843 28.9
5.4 248
2.0 3.95
5.6 19.9
2.0 34.0
5.6 267
2.2 4.34
5.8 21.3
2.2 41.2
5.8 286
2.4 4.74
6.0 22.8
2.4 49.0
6.0 306
2.6 5.13
6.2 24.3
2.6 57.5
6.2 327
2.8 5.53
6.4 25.9
2.8 66.7
6.4 349
3.0 5.92
6.6 27.6
3.0 76.6
6.6 371
3.2 6.48
6.8 29.3
3.2 87.2
6.8 394
3.4 7.32
7.0 31.0
3.4 98.4
7.0 417
3.6 8.20
7.2 32.8
3.6 110
7.2 441
3.8 9.14
7.4 34.7
3.8 123
7.4 466
4.0 10.1
7.6 36.6
4.0 136
7.6 492
4.2 11.2
7.8 38.5
4.2 150
7.8 518
4.4 12.3
7.956 40.1
4.4 165
7.956 539
m (kg)
A
min
(m2)
4.6 20.0
4.8 21.8
5.0 23.6
≤1.842
5.2 25.6
1.843 4.45
5.4 27.6
2.0 4.83
5.6 29.7
2.2 5.31
5.8 31.8
2.4 5.79
6.0 34.0
2.6 6.39
6.2 36.4
2.8 7.41
6.4 38.7
3.0 8.51
6.6 41.2
3.2 9.68
6.8 43.7
3.4 10.9
7.0 46.3
3.6 12.3
7.2 49.0
3.8 13.7
7.4 51.8
4.0 15.1
7.6 54.6
4.2 16.7
7.8 57.5
4.4 18.3
7.956 59.9
Wall-mounted
unit
(b)
m (kg)
A
min
(m2)
Floor-standing
unit
(c)
m (kg)
A
min
(m2)
UPOZORENJE
Ako uređaj sadrži rashladno sredstvo R32, tada površina poda prostorije u kojoj se uređaj postavlja, radi i sprema MORA biti veća od minimalne površine poda definirane u donjoj tablici A (m2). To se odnosi na:
▪ Unutarnje jedinice bez osjetnika za curenje rashladnog
sredstva; kod unutarnje jedinice sa osjetnikom za curenje rashladnog sredstva, pogledajte Priručnik za postavljanje
▪ Vanjske jedinice postavljene ili pohranjene u
zatvorenom prostoru (primjerice: zimski vrt, garaža, strojarnica)
▪ Cjevovod u neprovjetravanim prostorima
Određivanje minimalne površine poda
1 Odredite ukupno punjenje rashladnog sredstva u sustavu
(= tvorničko punjenje rashladnog sredstva + količina dodatnog punjenja).
2 Odredite koji graf ili tablicu želite upotrijebiti.
▪ Za unutarnje jedinice: Je li uređaj postavljen na strop, zid ili
stoji na podu?
▪ Za vanjske jedinice postavljene ili spremljene u zatvorenom
prostoru, i cjevovode u neprovjetravanim prostorijama, to ovisi o visini postavljanja:
Ako je visina postavljanja… Tada koristite graf ili tablicu za…
<1,8m Jedinice koje stoje na podu 1,8≤x<2,2m Jedinice postavljene na zid ≥2,2m Jedinice postavljene na strop
3 Koristite graf ili tablicu da odredite minimalnu površinu poda.
Referentni vodič za instalatera
4
m Ukupno punjenje rashladnog sredstva u sustavu
A
Minimalna površina poda
min
(a) Ceiling-mounted unit (= Jedinica postavljena na strop) (b) Wall-mounted unit (= Jedinica postavljena na zid)
FDXM25~60F3V1B(9)
Split sustav za klimatizaciju
4P550955-1 – 2018.07
1 Opće mjere opreza
(c) Floor-standing unit (= Jedinica koja stoji na podu)

1.2.3 Rashladno sredstvo

Ako je primjenjivo. Za više informacija pogledajte priručnik za postavljanje ili referentni vodič za instalatera uređaja.
OBAVIJEST
Pobrinite se da cjevovod za rashladno sredstvo udovoljava važećim zakonima. U Europi vrijedi standard EN378.
OBAVIJEST
Pazite da vanjske cijevi i priključci NE BUDU izloženi naprezanju.
UPOZORENJE
Tijekom testiranja NIKAD proizvod ne izlažite tlaku višem od maksimalnog dopuštenog (kao što je naznačeno na nazivnoj pločici jedinice).
UPOZORENJE
U slučaju istjecanja rashladnog sredstva poduzmite odgovarajuće mjere opreza. Ako rashladni plin curi, odmah prozračite prostor. Mogući rizici:
▪ Prekomjerna koncentracija rashladnog sredstva u
zatvorenoj prostoriji može prouzročiti manjak kisika.
▪ Ako rashladni plin dođe u kontakt s vatrom, može
nastati otrovni plin.
OPASNOST: RIZIK OD EKSPLOZIJE Prepumpavanje – Curenje rashladnog sredstva. Ako
želite prepumpati sustav, a postoji curenje u krugu rashladnog sredstva:
▪ NEMOJTE koristiti funkciju automatskog ispumpavanja
kojom možete sve rashladno sredstvo iz sustava skupiti u vanjsku jedinicu. Moguća posljedica: Samoizgaranje i eksplozija kompresora zbog ulaska zraka u kompresor tijekom rada.
▪ Koristite zasebni sustav sakupljanja tako da jedinica
kompresora NE mora raditi.
UPOZORENJE
UVIJEK prikupite otpadna rashladna sredstva. NE ispuštajte ih izravno u okoliš. Za vakuumiranje instalacije upotrijebite vakuumsku sisaljku.
OBAVIJEST
Nakon priključivanja svih cijevi provjerite ne curi li negdje plin. Za detekciju istjecanja plina upotrijebite dušik.
OBAVIJEST
▪ Da se izbjegne prekid rada kompresora, NEMOJTE
puniti rashladno sredstvo preko navedene količine.
▪ Pri otvaranju rashladnog sustava, s rashladnim
sredstvom se MORA postupati u skladu s važećim propisima.
UPOZORENJE
U sustavu ne smije biti kisika. Rashladno sredstvo može se puniti tek nakon testa curenja i vakuumskog isušivanja.
▪ U slučaju potrebe za dodatnim punjenjem pogledajte nazivnu
pločicu jedinice. Na njoj je navedena vrsta i potrebna količina rashladnog sredstva.
▪ Ova jedinica tvornički je napunjena rashladnim sredstvom. Ovisno
o veličini i duljini cijevi neki sustavi zahtijevaju dodatno punjenje rashladnog sredstva.
▪ Upotrebljavajte alate isključivo za vrstu rashladnog sredstva koja
se rabi u sustavu kako biste osigurali otpor tlaka i spriječili ulazak stranih tvari u sustav.
▪ Tekuće rashladno sredstvo punite na sljedeći način:
Ako Tada
Postoji sifonska cijev (tj. na cilindru je oznaka
"opremljen sifonom za punjenje tekućine")
NEMA sifonske cijevi Punite tako da je cilindar okrenut
▪ Polako otvorite cilindre rashladnog sredstva. ▪ Napunite tekućim rashladnim sredstvom. Dodavanje sredstva u
plinovitom obliku moglo bi onemogućiti ispravan rad.
OPREZ
Pri dovršetku postupka punjenja rashladnog sredstva ili u stanci, odmah zatvorite ventil spremnika rashladnog sredstva. Ako ventil NIJE odmah zatvoren, preostali tlak može napuniti dodatno rashladno sredstvo. Moguća posljedica: Pogrešna količina rashladnog sredstva.
Punite tako da je cilindar u uspravnom položaju.
naopako.

1.2.4 Slana voda

Ako je primjenjivo. Za više informacija pogledajte priručnik za postavljanje ili referentni vodič za instalatera uređaja.
UPOZORENJE
Odabir slane vode MORA biti u skladu s važećim propisima.
UPOZORENJE
U slučaju istjecanja slane vode poduzmite odgovarajuće mjere opreza. Ako slana voda istječe, odmah prozračite prostor i obratite se svom lokalnom dobavljaču.
UPOZORENJE
Temperatura u okolini unutar jedinice može postati puno veća od sobne temperature, npr. 70°C. U slučaju istjecanja slane vode, vrući dijelovi unutar jedinice mogu dovesti do opasne situacije.
UPOZORENJE
Upotreba i instalacija uređaja MORA biti u skladu sa sigurnosnim mjerama opreza i mjerama za zaštitu okoliša utvrđenima primjenjivim propisima.

1.2.5 Voda

Ako je primjenjivo. Za više informacija pogledajte priručnik za postavljanje ili referentni vodič za instalatera uređaja.
OBAVIJEST
Kvaliteta vode mora biti u skladu sa EU Direktivom 98/83EZ.
FDXM25~60F3V1B(9) Split sustav za klimatizaciju 4P550955-1 – 2018.07
Referentni vodič za instalatera
5

2 O dokumentaciji

1.2.6 Električno

OPASNOST: RIZIK OD STRUJNOG UDARA SA SMRTNIM POSLJEDICAMA
▪ Potpuno isključite napajanje prije skidanja poklopca s
razvodnekutije, spajanja bilo kakvih elektroinstalacija ili dodirivanja električnih dijelova.
▪ Prije servisiranja odspojite napajanje, pričekajte više od
1minute pa izmjerite napon na stezaljkama električnog kondenzatora glavnog strujnog kruga ili električnim komponentama. Napon MORA biti manji od 50V DC da biste mogli dodirnuti električne komponente.
Lokaciju stezaljki potražite u shemi ožičenja. ▪ NE dodirujte električne komponente mokrim rukama. ▪ NE ostavljajte jedinicu bez nadzora kada je s nje
uklonjen servisni poklopac.
UPOZORENJE
Ako NIJE tvornički ugrađen, u fiksno ožičenje MORA se ugraditi glavni prekidač ili drugi uređaj za odspajanje kod kojega dolazi do razdvajanja kontakata na svim polovima, čime se jamči potpuno odspajanje propisano za prenaponsku kategorijuIII.
UPOZORENJE
▪ Upotrebljavajte SAMO bakrene žice. ▪ Uvjerite se da je vanjsko ožičenje u skladu s važećim
zakonima. ▪ Sva ožičenja MORAJU biti provedena u skladu sa
shemom ožičenja koja se isporučuje s proizvodom. ▪ NIKADA ne stišćite višežilne kabele te se pobrinite da
kabeli NE dolaze u dodir s cijevima i oštrim rubovima.
Pazite da nema vanjskog naprezanja na priključne
stezaljke. ▪ Obavezno instalirajte uzemljenje. NE uzemljujte uređaj
na vodovodnu cijev, stabilizator napona ili uzemljenje
telefona. Nepotpuno uzemljenje može prouzročiti strujni
udar. ▪ Obavezno primijenite zaseban strujni krug. NIKADA ne
dijelite izvor napajanja s nekim drugim uređajem. ▪ Provjerite jeste li postavili potrebne osigurače ili
prekidače strujnog kruga. ▪ Obavezno instalirajte zaštitu od dozemnog spoja.
Propuštajući da to učinite možete uzrokovati udar struje
ili požar. ▪ Pri postavljanju zaštite od dozemnog spoja provjerite je
li ona kompatibilna s inverterom (otporna na električne
smetnje visokih frekvencija) kako bi se izbjeglo
nepotrebno otvaranje zaštite od dozemnog spoja.
OBAVIJEST
Mjere opreza prilikom postavljanja ožičenja napajanja:
▪ NEMOJTE povezivati ožičenje različitih debljina s
rednim stezaljkama (labavi dijelovi u ožičenju napajanja mogu prouzročiti neuobičajenu toplinu).
▪ Kada spajate žice koje su iste debljine, činite to kako je
prikazano na gornjoj slici.
▪ Za ožičenje upotrijebite namjensku žicu napajanja i
dobro pričvrstite, a zatim osigurajte kako izvodna ploča ne bi bila pod vanjskim pritiskom.
▪ Za pričvršćivanje vijaka izvoda upotrijebite odgovarajući
odvijač. Vijak s malom glavom oštetit će glavu pa odgovarajuće zatezanje neće biti moguće.
▪ Prekomjernim zatezanjem terminalnih vijaka možete ih
oštetiti.
Postavite strujne kabele najmanje 1metar od televizora i radija da biste spriječili smetnje. Ovisno o radiovalovima, udaljenost od 1metra možda neće biti dovoljna.
UPOZORENJE
▪ Po završetku radova na elektrici provjerite jesu li sve
električne komponente i priključak u kutiji s električnim dijelovima dobro spojeni.
▪ Uvjerite se da su svi poklopci zatvoreni prije pokretanja
jedinice.
OBAVIJEST
Postavljanje je moguće samo ako je napajanje trofazno, a kompresor se može uključiti, odnosno isključiti.
Ako postoji mogućnost reverzne faze nakon kratkotrajnog nestanka struje te ponovnog uključivanja napajanja tijekom rada uređaja, krug zaštite reverzne faze priključite lokalno. Rad uređaja u reverznoj fazi može pokvariti kompresor i druge dijelove.
2 O dokumentaciji

2.1 O ovom dokumentu

INFORMACIJE
Provjerite ima li korisnik tiskanu dokumentaciju i zamolite ga/je da je čuva za buduću upotrebu.
Ciljana publika
Ovlašteni instalateri
Referentni vodič za instalatera
6
INFORMACIJE
Ovaj je uređaj namijenjen za upotrebu od strane stručnjaka ili obučenih korisnika u trgovinama, lakoj industriji i na poljoprivrednim dobrima ili za upotrebu u poslovne i privatne svrhe od strane laika.