Daikin ETVH16S18EA6V, ETVH16S23EA6V, ETVH16S18EA9W, ETVH16S23EA9W, ETVX16S18EA6V Installation manuals

...
https://daikintechnicaldatahub.eu
Installation manual
Daikin Altherma 3 H HT F
ETVH16S18EA6V ETVH16S23EA6V ETVH16S18EA9W ETVH16S23EA9W
ETVX16S18EA6V ETVX16S23EA6V ETVX16S18EA9W ETVX16S23EA9W
Installation manual
Daikin Altherma 3 H HT F
English
Directivelor, cu amendamentele respective.
<A>
<B>
<C>
DEKRA (NB0344)
2192529.0551-EMC
DAIKIN.TCF.034B2/01-2021
Direktive z vsemi spremembami.
Direktiivid koos muudatustega.
Директиви, с техните изменения.
Direktyvose su papildymais.
Direktīvās un to papildinājumos.
Smernice, v platnom znení.
18192021222324
Direktiver, med senere ændringer.
Direktiv, med företagna ändringar.
Direktiver, med foretatte endringer.
10111213141516
Directives, as amended.
Direktiven, gemäß Änderung.
deklaruje na własną i wyłączną odpowiedzialność, że urządzenia, których ta deklaracja dotyczy:
declară pe proprie răspundere că echipamentele la care se referă această declaraţie:
z vso odgovornostjo izjavlja, da je oprema naprav, na katero se izjava nanaša:
kinnitab oma täielikul vastutusel, et käesoleva deklaratsiooni alla kuuluv varustus:
декларира на своя отговорност, че оборудването, за коeто се отнася тази декларация:
visiška savo atsakomybe skelbia, kad įranga, kuriai taikoma ši deklaracija:
ar pilnu atbildību apliecina, ka tālāk aprakstītās iekārtas, uz kurām attiecas šī deklarācija:
vyhlasuje na vlastnú zodpovednosť, že zariadenie, na ktoré sa vzťahuje toto vyhlásenie:
tamamen kendi sorumluluǧunda olmak üzere bu bildirinin ilgili olduǧu donanımının aşaǧıdaki gibi olduǧunu beyan eder:
17
18
19
20
21
22
23
24
25
megfelelnek az alábbi szabvány(ok)nak vagy egyéb irányadó dokumentum(ok)nak, ha azokat előírás szerint használják:
spełniają wymogi następujących norm i innych dokumentów normalizacyjnych, pod warunkiem że używane są zgodnie z naszymi instrukcjami:
sunt în conformitate cu următorul (următoarele) standard(e) sau alt(e) document(e) normativ(e), cu condiţia ca acestea să fie utilizate în conformitate cu
instrucţiunile noastre:
skladni z naslednjimi standardi in drugimi normativi, pod pogojem, da se uporabljajo v skladu z našimi navodili:
on vastavuses järgmis(t)e standardi(te)ga või teiste normatiivsete dokumentidega, kui neid kasutatakse vastavalt meie juhenditele:
съответстват на следните стандарти или други нормативни документи, при условие, че се използват съгласно нашите инструкции:
atitinka žemiau nurodytus standartus ir (arba) kitus norminius dokumentus su sąlyga, kad yra naudojami pagal mūsų nurodymus:
tad, ja lietoti atbilstoši ražotāja norādījumiem, atbilst sekojošiem standartiem un citiem normatīviem dokumentiem:
sú v zhode s nasledovnou(ými) normou(ami) alebo iným(i) normatívnym(i) dokumentom(ami), za predpokladu, že sa používajú v súlade snašim
návodom:
161718192021222324
ürünün, talimatlarımıza göre kullanılması koşuluyla aşağıdaki standartlar ve norm belirten belgelerle uyumludur:
25
Directives, telles que modifiées.
010203040506070809
Değiştirilmiş halleriyle Yönetmelikler.
25
Direktiivejä, sellaisina kuin ne ovat muutettuina.
v platném znění.
Smjernice, kako je izmijenjeno.
irányelv(ek) és módosításaik rendelkezéseit.
z późniejszymi poprawkami.
17
Richtlijnen, zoals geamendeerd.
Directivas, según lo enmendado.
Direttive, come da modifica.
Οδηγιών, όπως έχουν τροποποιηθεί.
Directivas, conforme alteração em.
както е изложено в <A> и оценено положително от <B>
съгласно Сертификата<C>.
kaip nustatyta <A> ir kaip teigiamai nuspręsta <B> pagal
Sertifikatą<C>.
kā norādīts <A> un atbilstoši <B> pozitīvajam vērtējumam
saskaņā ar sertifikātu<C>.
ako bolo uvedené v <A> a pozitívne zistené <B> vsúlade
s osvedčením<C>.
<A>’da belirtildiği gibi ve <C>Sertifikasına göre <B>
tarafından olumlu olarak değerlendirildiği gibi.
Директив со всеми поправками.
21Забележка*
22Pastaba*
23Piezīmes*
24Poznámka*
25Not*
a(z) <A> alapján, a(z) <B> igazolta a megfelelést, a(z)
<C>tanúsítvány szerint.
zgodnie z dokumentacją <A>, pozytywną
opinią <B> i Świadectwem<C>.
aşa cum este stabilit în <A> şi apreciat pozitiv de<B>
în conformitate cu Certificatul<C>.
kot je določeno v <A> in odobreno s strani <B>
vskladu scertifikatom<C>.
nagu on näidatud dokumendis <A> ja heaks kiidetud
<B> järgi vastavalt sertifikaadile<C>.
16Megjegyzés*
17Uwaga*
18Notă*
19Opomba*
20Märkus*
Low Voltage 2014/35/EU
enligt <A> och godkänts av <B> enligt
Certifikatet<C>.
som det fremkommer i <A> og gjennom positiv
bedømmelse av <B> ifølge Sertifikat<C>.
jotka on esitetty asiakirjassa <A> ja jotka <B>
on hyväksynyt Sertifikaatin<C> mukaisesti.
jak bylo uvedeno v <A> a pozitivně zjištěno
<B> vsouladu sosvědčením<C>.
kako je izloženo u <A> i pozitivno ocijenjeno odstrane
Electromagnetic Compatibility 2014/30/EU *
заявляет, исключительно под свою ответственность, что оборудование, к которому относится настоящее заявление:
erklærer under eneansvarlig, at udstyret, som er omfattet af denne erklæring:
deklarerar i egenskap av huvudansvarig, att utrustningen som berörs av denna deklaration innebär att:
erklærer et fullstendig ansvar for at det utstyr som berøres av denne deklarasjon innebærer at:
ilmoittaa yksinomaan omalla vastuullaan, että tämän ilmoituksen tarkoittamat laitteet:
prohlašuje ve své plné odpovědnosti, že zařízení, k němuž se toto prohlášení vztahuje:
izjavljuje pod isključivo vlastitom odgovornošću da oprema na koju se ova izjava odnosi:
teljes felelőssége tudatában kijelenti, hogy a berendezések, melyekre e nyilatkozat vonatkozik:
09
10
11
12
13
14
15
16
estão em conformidade com a(s) seguinte(s) norma(s) ou outro(s) documento(s) normativo(s), desde que estes sejam utilizados de
acordo com as nossas instruções:
соответствуют следующим стандартам или другим нормативным документам, при условии их использования согласно нашим инструкциям:
overholder følgende standard(er) eller andet/andre retningsgivende dokument(er), forudsat at disse anvendes i henhold til vore instrukser:
respektive utrustning är utförd i överensstämmelse med och följer följande standard(er) eller andra normgivande dokument, under förutsättning att
användning sker i överensstämmelse med våra instruktioner:
respektive utstyr er i overensstemmelse med følgende standard(er) eller andre normgivende dokument(er), under forutssetning av at disse brukes i
henhold til våre instrukser:
vastaavat seuraavien standardien ja muiden ohjeellisten dokumenttien vaatimuksia edellyttäen, että niitä käytetään ohjeidemme mukaisesti:
za předpokladu, že jsou využívány v souladu s našimi pokyny, odpovídají následujícím normám nebo normativním dokumentům:
08091011121314
u skladu sa slijedećim standardom(ima) ili drugim normativnim dokumentom(ima), uz uvjet da se oni koriste u skladu s našim uputama:
15
ob upoštevanju določb:
vastavalt nõuetele:
следвайки клаузите на:
laikantis nuostatų, pateikiamų:
ievērojot prasības, kas noteiktas:
19202122232425
održiavajúc ustanovenia:
11Information*
12Merk*
13Huom*
bunun koşullarına uygun olarak:
delineato nel <A> e giudicato positivamente da<B>
secondo il Certificato<C>.
όπως καθορίζεται στο <A> και κρίνεται θετικά
από το <B> σύμφωνα με το Πιστοποιητικό<C>.
tal como estabelecido em <A> e com o parecer positivo
<B> prema Certifikatu<C>.
14Poznámka*
15Napomena*
de <B> de acordo com o Certificado<C>.
как указано в <A> и в соответствии сположительным
решением <B> согласно Свидетельству<C>.
som anført i <A> og positivt vurderet af <B> ihenhold til
Certifikat<C>.
Hiromitsu Iwasaki
Director
Ostend, 3rd of May 2021
declares under its sole responsibility that the equipment to which this declaration relates:
erklärt auf seine alleinige Verantwortung daß die Ausrüstung für die diese Erklärung bestimmt ist:
CE - DECLARATION-OF-CONFORMITY CE - DECLARACION-DE-CONFORMIDAD CE - DECLARAÇÃO-DE-CONFORMIDADE CE - ERKLÆRING OM-SAMSVAR CE - IZJAVA-O-USKLAĐENOSTI CE - IZJAVA O SKLADNOSTI CE - ATITIKTIES-DEKLARACIJA
CE - KONFORMITÄTSERKLÄRUNG CE - DICHIARAZIONE-DI-CONFORMITA CE - ЗАЯВЛЕНИЕ-О-СООТВЕТСТВИИ CE - ILMOITUS-YHDENMUKAISUUDESTA CE - MEGFELELŐSÉGI-NYILATKOZAT CE - VASTAVUSDEKLARATSIOON CE - ATBILSTĪBAS-DEKLARĀCIJA
CE - DECLARATION-DE-CONFORMITE CE - ΔHΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ CE - OVERENSSTEMMELSESERKLÆRING CE - PROHLÁŠENÍ-O-SHODĚ CE - DEKLARACJA-ZGODNOŚCI CE - ДЕКЛАРАЦИЯ-ЗА-СЪОТВЕТСТВИЕ CE - VYHLÁSENIE-ZHODY
CE - CONFORMITEITSVERKLARING CE - FÖRSÄKRAN-OM-ÖVERENSTÄMMELSE CE - DECLARAŢIE-DE-CONFORMITATE CE - UYGUNLUK-BEYANI
déclare sous sa seule responsabilité que l'équipement visé par la présente déclaration:
Daikin Europe N.V.
01
02
03
06Nota*
07Σημείωση*
08Nota*
09Примечание*
10Bemærk*
under iagttagelse af bestemmelserne i:
enligt villkoren i:
gitt i henhold til bestemmelsene i:
noudattaen määräyksiä:
za dodržení ustanovení předpisu:
prema odredbama:
követi a(z):
zgodnie z postanowieniami Dyrektyw:
101112131415161718
verklaart hierbij op eigen exclusieve verantwoordelijkheid dat de apparatuur waarop deze verklaring betrekking heeft:
declara bajo su única responsabilidad que el equipo al que hace referencia la declaración:
dichiara sotto la propria responsabilità che gli apparecchi a cui è riferita questa dichiarazione:
δηλώνει με αποκλειστική της ευθύνη ότι ο εξοπλισμός στον οποίο αναφέρεται η παρούσα δήλωση:
declara sob sua exclusiva responsabilidade que os equipamentos a que esta declaração se refere:
ETVH16S18EA6V, ETVH16S23EA6V, ETVH16S18EA9W, ETVH16S23EA9W,
04
05
06
07
ETVX16S18EA6V, ETVX16S23EA6V, ETVX16S18EA9W, ETVX16S23EA9W,
08
are in conformity with the following standard(s) or other normative document(s), provided that these are used in accordance with our instructions:
der/den folgenden Norm(en) oder einem anderen Normdokument oder -dokumenten entspricht/entsprechen, unter der Voraussetzung, daß sie gemäß
unseren Anweisungen eingesetzt werden:
sont conformes à la/aux norme(s) ou autre(s) document(s) normatif(s), pour autant qu'ils soient utilisés conformément à nos instructions:
conform de volgende norm(en) of één of meer andere bindende documenten zijn, op voorwaarde dat ze worden gebruikt overeenkomstig onze
instructies:
están en conformidad con la(s) siguiente(s) norma(s) u otro(s) documento(s) normativo(s), siempre que sean utilizados de acuerdo con nuestras
instrucciones:
sono conformi al(i) seguente(i) standard(s) o altro(i) documento(i) a carattere normativo, a patto che vengano usati in conformità alle nostre istruzioni:
είναι σύμφωνα με το(α) ακόλουθο(α) πρότυπο(α) ή άλλο έγγραφο(α) κανονισμών, υπό την προϋπόθεση ότι χρησιμοποιούνται
01020304050607
σύμφωνα με τις οδηγίες μας:
following the provisions of:
gemäß den Vorschriften der:
conformément aux stipulations des:
EN60335-2-40,
overeenkomstig de bepalingen van:
010203040506070809
în urma prevederilor:
as set out in <A> and judged positively by <B>
according to the Certificate<C>.
wie in <A> aufgeführt und von <B> positiv
beurteilt gemäß Zertifikat<C>.
tel que défini dans <A> et évalué positivement par <B>
conformément au Certificat<C>.
zoals vermeld in <A> en positief beoordeeld door <B>
siguiendo las disposiciones de:
secondo le prescrizioni per:
με τήρηση των διατάξεων των:
de acordo com o previsto em:
в соответствии с положениями:
01Note*
02Hinweis*
03Remarque*
04Bemerk*
overeenkomstig Certificaat<C>.
como se establece en <A> y es valorado
positivamente por <B> de acuerdo con el
05Nota*
Certificado<C>.
3P644742-2

Table of contents

Table of contents

1 About the documentation 3

1.1 About this document.................................................................. 3
2 Specific installer safety instructions 4 3 About the box 5
3.1 Indoor unit ................................................................................. 5
3.1.1 To remove the accessories from the indoor unit......... 5
3.1.2 To handle the indoor unit ............................................ 5
4 Unit installation 5
4.1 Preparing the installation site .................................................... 5
4.1.1 Installation site requirements of the indoor unit .......... 5
4.2 Opening and closing the unit..................................................... 5
4.2.1 To open the indoor unit............................................... 5
4.2.2 To lower the switch box on the indoor unit.................. 6
4.2.3 To close the indoor unit............................................... 7
4.3 Mounting the indoor unit............................................................ 7
4.3.1 To install the indoor unit.............................................. 7
4.3.2 To connect the drain hose to the drain ....................... 7
5 Piping installation 8
5.1 Preparing water piping .............................................................. 8
5.1.1 To check the water volume and flow rate ................... 8
5.2 Connecting water piping............................................................ 9
5.2.1 To connect the water piping........................................ 9
5.2.2 To connect the recirculation piping ............................. 9
5.2.3 To fill the water circuit ................................................. 9
5.2.4 To protect the water circuit against freezing ............... 10
5.2.5 To fill the domestic hot water tank .............................. 11
5.2.6 To insulate the water piping........................................ 11
6 Electrical installation 11
6.1 About electrical compliance....................................................... 11
6.2 Guidelines when connecting the electrical wiring...................... 11
6.3 Connections to the indoor unit................................................... 11
6.3.1 To connect the main power supply ............................. 12
6.3.2 To connect the backup heater power supply .............. 13
6.3.3 To connect the shut-off valve...................................... 14
6.3.4 To connect the electricity meters ................................ 15
6.3.5 To connect the domestic hot water pump................... 15
6.3.6 To connect the alarm output ....................................... 16
6.3.7 To connect the space cooling/heating ON/OFF
output .......................................................................... 16
6.3.8 To connect the changeover to external heat source... 17
6.3.9 To connect the power consumption digital inputs....... 17
6.3.10 To connect the safety thermostat (normally closed
contact) ....................................................................... 18
6.3.11 To connect a Smart Grid............................................. 18
6.3.12 To connect the WLAN cartridge (delivered as
accessory)................................................................... 20
6.4 After connecting the electrical wiring to the indoor unit ............. 20
7 Configuration 20
7.1 Overview: Configuration ............................................................ 20
7.1.1 To access the most used commands ......................... 21
7.2 Configuration wizard.................................................................. 22
7.2.1 Configuration wizard: Language ................................. 22
7.2.2 Configuration wizard: Time and date .......................... 22
7.2.3 Configuration wizard: System ..................................... 22
7.2.4 Configuration wizard: Backup heater.......................... 23
7.2.5 Configuration wizard: Main zone................................. 24
7.2.6 Configuration wizard: Additional zone......................... 24
7.2.7 Configuration wizard: Tank ......................................... 25
7.3 Weather-dependent curve......................................................... 25
7.3.1 What is a weather-dependent curve? ......................... 25
7.3.2 2-points curve ............................................................. 26
7.3.3 Slope-offset curve........................................................ 26
7.3.4 Using weather-dependent curves ................................ 27
7.4 Settings menu ............................................................................ 27
7.4.1 Main zone .................................................................... 27
7.4.2 Additional zone ............................................................ 28
7.4.3 Information................................................................... 28
7.5 Menu structure: Overview installer settings................................ 29
8 Commissioning 30
8.1 Checklist before commissioning................................................. 30
8.2 Checklist during commissioning ................................................. 30
8.2.1 To check the minimum flow rate .................................. 30
8.2.2 To perform an air purge ............................................... 31
8.2.3 To perform an operation test run ................................. 31
8.2.4 To perform an actuator test run ................................... 31
8.2.5 To perform an underfloor heating screed dryout.......... 31
9 Hand-over to the user 31 10 Technical data 33
10.1 Piping diagram: Indoor unit ........................................................ 33
10.2 Wiring diagram: Indoor unit ........................................................ 34
1 About the documentation

1.1 About this document

Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set consists of:
General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the indoor unit)
Operation manual:
▪ Quick guide for basic usage
▪ Format: Paper (in the box of the indoor unit)
User reference guide:
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Installation manual – Outdoor unit:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
Installation manual – Indoor unit:
▪ Installation instructions
▪ Format: Paper (in the box of the indoor unit)
Installer reference guide:
▪ Preparation of the installation, good practices, reference
data,…
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Addendum book for optional equipment:
▪ Additional info about how to install optional equipment
▪ Format: Paper (in the box of the indoor unit) + Digital files on
http://www.daikineurope.com/support-and-manuals/product­information/
ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02
Installation manual
3

2 Specific installer safety instructions

Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages are translations.
Technical engineering data
▪ A subset of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
Online tools
In addition to the documentation set, some online tools are available for installers:
Daikin Technical Data Hub
▪ Central hub for technical specifications of the unit, useful tools,
digital resources, and more.
▪ Publicly accessible via https://daikintechnicaldatahub.eu.
Heating Solutions Navigator
▪ Digital toolbox that offers a variety of tools to facilitate the
installation and configuration of heating systems.
▪ To access Heating Solutions Navigator, registration to the
Stand By Me platform is required. For more information, see
https://professional.standbyme.daikin.eu.
Daikin e-Care
▪ Mobile app for installers and service technicians that allows you
to register, configure and troubleshoot heating systems.
▪ The mobile app can be downloaded for iOS and Android
devices using the QR codes below. Registration to the Stand By Me platform is required to access the app.
App Store Google Play
WARNING
Install the tundish away from any electrical device. Possible consequence: Electric shock or fire.
In case of freeze protection by glycol:
WARNING
Ethylene glycol is toxic.
WARNING
Due to the presence of glycol, corrosion of the system is possible. Uninhibited glycol will turn acidic under the influence of oxygen. This process is accelerated by the presence of copper and high temperatures. The acidic uninhibited glycol attacks metal surfaces and forms galvanic corrosion cells that cause severe damage to the system. Therefore it is important that:
▪ the water treatment is correctly executed by a qualified
water specialist,
▪ a glycol with corrosion inhibitors is selected to
counteract acids formed by the oxidation of glycols,
▪ no automotive glycol is used because their corrosion
inhibitors have a limited lifetime and contain silicates which can foul or plug the system,
▪ galvanized pipes are NOT used in glycol systems since
the presence may lead to the precipitation of certain components in the glycol's corrosion inhibitor.
Electrical installation (see "6Electrical installation"[411])
DANGER: RISK OF ELECTROCUTION
WARNING
Electrical wiring connection method MUST be in accordance with the instructions from this manual. See
"6Electrical installation"[411].
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Opening and closing the unit (see "4.2Opening and closing the
unit"[45])
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
Mounting the indoor unit (see "4.3Mounting the indoor
unit"[47])
WARNING
Fixing method of the indoor unit MUST be in accordance with the instructions from this manual. See "4.3Mounting
the indoor unit"[47].
Piping installation (see "5Piping installation"[48])
WARNING
Field piping method MUST be in accordance with the instructions from this manual. See "5 Piping
installation"[48].
WARNING
▪ All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable legislation.
▪ Make electrical connections to the fixed wiring.
▪ All components procured on-site and all electrical
construction MUST comply with the applicable legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
CAUTION
Do NOT push or place redundant cable length in the unit.
WARNING
The backup heater MUST have a dedicated power supply and MUST be protected by the safety devices required by the applicable legislation.
CAUTION
To guarantee the unit is completely earthed, always connect the backup heater power supply and the earth cable.
WARNING Stripped wire. Make sure that stripped wire cannot make
contact with possible water on the bottom plate.
Installation manual
4
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02

3 About the box

b
a
1×c1×d1×e1×
f
i
h
j
g
b
a a
b
300
≥600
500
(mm)
a
b
d
c
e
Commissioning (see "8Commissioning"[430])
WARNING
Commissioning method MUST be in accordance with the instructions from this manual. See
"8Commissioning"[430].
3 About the box

3.1 Indoor unit

3.1.1 To remove the accessories from the indoor unit

4 Unit installation

4.1 Preparing the installation site

4.1.1 Installation site requirements of the indoor unit

▪ The indoor unit is designed for indoor installation only and for the
following ambient temperatures:
▪ Space heating operation: 5~30°C
▪ Space cooling operation: 5~35°C
▪ Domestic hot water production: 5~35°C
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models
▪ Heating only models + conversion kit (EKHVCONV*)
▪ Mind the measurement guidelines:
Maximum height difference between indoor unit and outdoor unit
Maximum total water piping length 50m
(a)
Precise water piping length can be determined using the Hydronic Piping Calculation tool. The Hydronic Piping Calculation tool is part of the Heating Solutions Navigator which can be reached via
https://professional.standbyme.daikin.eu. Please contact your
dealer if you have no access to Heating Solutions Navigator.
▪ Mind the following spacing installation guidelines:
10m
(a)
a Shut-off valves for water circuit b Overpressure bypass valve c General safety precautions d Addendum book for optional equipment e Indoor unit installation manual
f Operation manual g WLAN cartridge h Sealing rings for shut-off valves (space heating water
circuit)
i Sealing rings for field-supplied shut-off valves (domestic
hot water circuit)
j Sealing tape for low voltage wiring intake

3.1.2 To handle the indoor unit

Use the handles at the back and at the bottom to carry the unit.
ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02
a Handles at the back of the unit b Handles at the bottom of the unit. Carefully tilt the unit to
the back so that the handles become visible.
INFORMATION
If you have limited installation space, do the following before installing the unit in its final position: "4.3.2 To
connect the drain hose to the drain" [4 7]. It requires to
remove one or both side panels.

4.2 Opening and closing the unit

4.2.1 To open the indoor unit

Overview
a Top panel b User interface panel c Switch box cover d Front panel e High voltage switch box cover
Open
1 Remove the top panel.
Installation manual
5
4 Unit installation
T25
2
1
1
3
4
X14Y
X1A
T25
T25
T25
1
2
T25
2 Remove the user interface panel. Open the hinges at the top
and slide the top panel upwards.
NOTICE
If you remove the user interface panel, also disconnect the cables from the back of the user interface panel to prevent damage.
5 If you need access to the high voltage components, remove the
high voltage switch box cover.
3 Remove the switch box cover.
4 If necessary, remove the front plate. This is, for example,
necessary in the following cases:
"4.2.2To lower the switch box on the indoor unit"[46]"4.3.2To connect the drain hose to the drain"[47] ▪ When you need access to the high voltage switch box
Installation manual
6

4.2.2 To lower the switch box on the indoor unit

During the installation, you will need access to the inside of the indoor unit. To have easier front access, put the switch box lower on the unit as follows:
Prerequisite: The user interface panel and front panel have been removed.
1 Remove the fixing plate at the top of the unit. 2 Tilt the switch box to the front and lift it out of its hinges.
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
4 Unit installation
3
3
≤1°
1° 1°
1
T25
3
2
3 Place the switch box lower on the unit. Use the 2 hinges located
lower on the unit.

4.2.3 To close the indoor unit

1 Close the cover of the switch box. 2 Put the switch box back into place. 3 Reinstall the top panel. 4 Reinstall the side panels. 5 Reinstall the front panel. 6 Reconnect the cables to the user interface panel. 7 Reinstall the user interface panel.
NOTICE
When closing the indoor unit cover, make sure that the tightening torque does NOT exceed 4.1N•m.

4.3 Mounting the indoor unit

NOTICE
Do NOT tilt the unit forwards:

4.3.2 To connect the drain hose to the drain

Water coming from the pressure relief valve is collected in the drain pan. The drain pan is connected to a drain hose inside the unit. You must connect the drain hose to an appropriate drain according to the applicable legislation. You can route the drain hose through the left or right side panel.
Prerequisite: The user interface panel and front panel have been removed.
1 Remove one of the side panels. 2 Cut out the rubber grommet. 3 Pull the drain hose through the hole. 4 Reattach the side panel. Ensure the water can flow through the
drain tube.
It is recommended to use a tundish to collect the water.
Option 1: Through the left side panel

4.3.1 To install the indoor unit

1 Lift the indoor unit from the pallet and place it on the floor. Also
see "3.1.2To handle the indoor unit"[45].
2 Connect the drain hose to the drain. See "4.3.2To connect the
drain hose to the drain"[47].
3 Slide the indoor unit into position. 4 Adjust the height of the leveling feet to compensate for floor
irregularities. The maximum allowed deviation is 1°.
ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02
Installation manual
7

5 Piping installation

1
T25
3
2
89°C (*)
75°C (*)
75°C (*)
M
EXAMPLE
(*) Maximum temperature for piping and accessories
Option 2: Through the right side panel
5 Piping installation

5.1 Preparing water piping

NOTICE
In case of plastic pipes, make sure they are fully oxygen diffusion tight according to DIN 4726. The diffusion of oxygen into the piping can lead to excessive corrosion.
NOTICE Water circuit requirements. Make sure to comply with the
water pressure and water temperature requirements below. For additional water circuit requirements, see the installer reference guide.
Water pressure – Domestic hot water. The maximum water
pressure is 4 bar. Provide adequate safeguards in the water circuit to ensure that the maximum pressure is NOT exceeded. The minimum water pressure to operate is 1 bar.
Water pressure – Space heating/cooling circuit. The maximum
water pressure is 3bar. Provide adequate safeguards in the water circuit to ensure that the maximum pressure is NOT exceeded. The minimum water pressure to operate is 1 bar.
Water temperature. All installed piping and piping accessories
(valve, connections,…) MUST withstand the following temperatures:
INFORMATION
The following illustration is an example and might NOT match your system layout.

5.1.1 To check the water volume and flow rate

Minimum water volume
Check that the total water volume in the installation is minimum 20 litres, the internal water volume of the outdoor unit NOT included.
NOTICE
When circulation in each space heating/cooling loop is controlled by remotely controlled valves, it is important that the minimum water volume is guaranteed, even if all of the valves are closed.
Minimum flow rate
Check that the minimum flow rate in the installation is guaranteed in all conditions. This minimum flow rate is required during defrost/ backup heater operation. For this purpose, use the overpressure bypass valve delivered with the unit, and respect the minimum water volume.
Minimum required flow rate
25l/min
NOTICE
To guarantee proper operation it is recommended to have a minimum flow of 28l/min during DHW.
NOTICE
If glycol was added to the water circuit, and the temperature of the water circuit is low, the flow rate will NOT be displayed on the user interface. In this case, the minimum flow rate can be checked by way of the pump test (check that the user interface does NOT display error 7H).
NOTICE
When circulation in each or certain space heating loops is controlled by remotely controlled valves, it is important that the minimum flow rate is guaranteed, even if all valves are closed. In case the minimum flow rate cannot be reached, a flow error 7H will be generated (no heating or operation).
See the installer reference guide for more information.
See the recommended procedure as described in "8.2 Checklist
during commissioning"[430].
Installation manual
8
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
5 Piping installation
b1b2
a1a2
c2
c1

5.2 Connecting water piping

5.2.1 To connect the water piping

NOTICE
Do NOT use excessive force when connecting the field piping and make sure the piping is aligned properly. Deformation of the piping can cause malfunctioning of the unit.
NOTICE
Do NOT use excessive force when connecting the piping. Deformation of the piping can cause malfunctioning of the unit.
1 Connect the O-rings and shut-off valves to the outdoor unit
water connection pipes of the indoor unit.
2 Connect the outdoor unit field piping to the shut-off valves. 3 Connect the O-rings and shut-off valves to the space heating/
cooling water pipes of the indoor unit.
4 Connect the space heating/cooling field piping of both zones to
the shut-off valves.
5 Connect the domestic hot water in and out pipes to the indoor
unit.
NOTICE
Overpressure bypass valve (delivered as accessory). We
recommend to install the overpressure bypass valve in the space heating water circuit.
▪ Mind the minimum water volume when choosing the
installation location of the overpressure bypass valve (at the indoor unit, or at the collector). See "5.1.1 To
check the water volume and flow rate"[48].
▪ Mind the minimum flow rate when adjusting the
overpressure bypass valve setting. See "5.1.1 To
check the water volume and flow rate" [4 8] and "8.2.1To check the minimum flow rate"[430].
NOTICE
Install air purge valves at all local high points.
NOTICE
A pressure relief valve (field supply) with an opening pressure of maximum 10bar (=1MPa) must be installed on the domestic cold water inlet connection in accordance with the applicable legislation.

5.2.2 To connect the recirculation piping

Prerequisite: Only required if you need recirculation in your system.
1 Remove the top panel from the unit, see "4.2.1To open the
indoor unit"[45].
2 Cut out the rubber grommet on top of the unit, and remove the
stop. The recirculation connector is placed below the hole.
3 Route the recirculation piping through the grommet and connect
it to the recirculation connector.
a1 Space heating/cooling – Water IN (screw connection, 1") a2 Space heating/cooling – Water OUT (screw connection,
b1 DHW – Cold water IN (screw connection, 3/4") b2 DHW – Hot water OUT (screw connection, 3/4") c1 Water IN from outdoor unit (screw connection, 1") c2 Water OUT to outdoor unit (screw connection, 1")
NOTICE
It is recommended to install shut-off valves to domestic cold water in and domestic hot water out connections. These shut-off valves are field supplied.
ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02
1")
4 Reattach the top panel.

5.2.3 To fill the water circuit

To fill the water circuit, use a field supply filling kit. Make sure you comply with the applicable legislation.
NOTICE
Make sure both air purge valves (one on the magnetic filter and one on the backup heater) are open.
All automatic air purge valves must remain open after commissioning.
Installation manual
9
5 Piping installation

5.2.4 To protect the water circuit against freezing

About freeze protection
Frost can damage the system. To prevent the hydraulic components from freezing, the software is equipped with special frost protection functions such as water pipe freeze prevention and drain prevention (see the installer reference guide) that include the activation of pump in case of low temperatures.
However, in case of a power failure, these functions cannot guarantee protection.
Do one of the following to protect the water circuit against freezing:
▪ Add glycol to the water. Glycol lowers the freezing point of the
water.
▪ Install freeze protection valves. Freeze protection valves drain the
water from the system before it can freeze.
NOTICE
If you add glycol to the water, do NOT install freeze protection valves. Possible consequence: Glycol leaking out of the freeze protection valves.
Freeze protection by glycol
About freeze protection by glycol
Adding glycol to the water lowers the freezing point of water.
WARNING
Ethylene glycol is toxic.
If… Then…
The system does NOT contain a domestic hot water tank
(a)
Propylene glycol, including the necessary inhibitors, classified as CategoryIII according to EN1717.
Required concentration of glycol
The required concentration of glycol depends on the lowest expected outdoor temperature, and on whether you want to protect the system from bursting or from freezing. To prevent the system from freezing, more glycol is required.
Add glycol according to the table below.
Lowest expected outdoor temperature
–5°C 10% 15% –10°C 15% 25% –15°C 20% 35% –20°C 25% — –25°C 30% — –30°C 35%
INFORMATION
▪ Protection against bursting: the glycol will prevent the
piping from bursting, but NOT the liquid inside the piping from freezing.
▪ Protection against freezing: the glycol will prevent the
liquid inside the piping from freezing.
Prevent from bursting
You can use either propylene
(a)
glycol
or ethylene glycol
Prevent from freezing
WARNING
Due to the presence of glycol, corrosion of the system is possible. Uninhibited glycol will turn acidic under the influence of oxygen. This process is accelerated by the presence of copper and high temperatures. The acidic uninhibited glycol attacks metal surfaces and forms galvanic corrosion cells that cause severe damage to the system. Therefore it is important that:
▪ the water treatment is correctly executed by a qualified
water specialist,
▪ a glycol with corrosion inhibitors is selected to
counteract acids formed by the oxidation of glycols,
▪ no automotive glycol is used because their corrosion
inhibitors have a limited lifetime and contain silicates which can foul or plug the system,
▪ galvanized pipes are NOT used in glycol systems since
the presence may lead to the precipitation of certain components in the glycol's corrosion inhibitor.
NOTICE
Glycol absorbs water from its environment. Therefore do NOT add glycol that has been exposed to air. Leaving the cap off the glycol container causes the concentration of water to increase. The glycol concentration is then lower than assumed. As a result, the hydraulic components might freeze up after all. Take preventive actions to ensure a minimal exposure of the glycol to air.
Types of glycol
The types of glycol that can be used depend on whether the system contains a domestic hot water tank:
If… Then…
The system contains a domestic hot water tank
Only use propylene glycol
(a)
NOTICE
▪ The required concentration might differ depending on
the type of glycol. ALWAYS compare the requirements from the table above with the specifications provided by the glycol manufacturer. If necessary, meet the requirements set by the glycol manufacturer.
▪ The added concentration of glycol should NEVER
exceed 35%.
▪ If the liquid in the system is frozen, the pump will NOT
be able to start. Mind that if you only prevent the system from bursting, the liquid inside might still freeze.
▪ When water is at standstill inside the system, the
system is very likely to freeze and get damaged.
Glycol and the maximum allowed water volume
Adding glycol to the water circuit reduces the maximum allowed water volume of the system. For more information, see the installer reference guide (topic "To check the water volume and flow rate").
Glycol setting
NOTICE
If glycol is present in the system, setting [E-0D] must be set to 1. If the glycol setting is NOT set correctly, the liquid inside the piping can freeze.
Freeze protection by freeze protection valves
About freeze protection valves
When no glycol is added to the water, you can use freeze protection valves to drain the water from the system before it can freeze.
▪ Install freeze protection valves (field supply) at all lowest points of
the field piping.
▪ Normally closed valves (located indoors near the piping entry/exit
points) can prevent that all water from indoor piping is drained when the freeze protection valves open.
Installation manual
10
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02

6 Electrical installation

NOTICE
When freeze protection valves are installed, set the minimum cooling setpoint (default=7°C) at least 2°C higher than the maximum opening temperature of the freeze protection valve. If lower, freeze protection valves can open during cooling operation.
For more information, see the installer reference guide.

5.2.5 To fill the domestic hot water tank

1 Open every hot water tap in turn to purge air from the system
pipe work.
2 Open the cold water supply valve. 3 Close all water taps after all air is purged. 4 Check for water leaks.

5.2.6 To insulate the water piping

The piping in the complete water circuit MUST be insulated to prevent condensation during cooling operation and reduction of the heating and cooling capacity.
Outdoor water piping insulation
See the installation manual of the outdoor unit, or the installer reference guide.
6 Electrical installation
DANGER: RISK OF ELECTROCUTION
WARNING
ALWAYS use multicore cable for power supply cables.
CAUTION
Do NOT push or place redundant cable length in the unit.
NOTICE
The distance between the high voltage and low voltage cables should be at least 50mm.

6.1 About electrical compliance

Only for the backup heater of the indoor unit
See "6.3.2To connect the backup heater power supply"[413].

6.2 Guidelines when connecting the electrical wiring

Tightening torques
Indoor unit:
Item Tightening torque (N•m)
X1M 2.45 ±10% X2M 0.88 ±10% X5M 0.88 ±10% X6M 2.45 ±10% X10M 0.88 ±10%

6.3 Connections to the indoor unit

Item Description
Power supply (backup heater)
Shut-off valve See "6.3.3To connect the shut-off
Electricity meters See "6.3.4To connect the electricity
Domestic hot water pump
Alarm output See "6.3.6To connect the alarm
Space cooling/heating operation control
Changeover to external heat source control
Power consumption digital inputs
Safety thermostat See "6.3.10To connect the safety
Smart Grid See "6.3.11To connect a Smart
Room thermostat (wired or wireless)
Heat pump convector There are different controllers and
See "6.3.2To connect the backup heater
power supply"[413].
valve"[414].
meters"[415].
See "6.3.5To connect the domestic hot
water pump"[415].
output"[416].
See "6.3.7To connect the space cooling/
heating ON/OFF output"[416].
See "6.3.8To connect the changeover to
external heat source"[417].
See "6.3.9To connect the power
consumption digital inputs"[417].
thermostat (normally closed contact)"[418].
Grid"[418].
See below table.
Wires: 0.75mm²
Maximum running current: 100mA For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
setups possible for the heat pump convectors.
Depending on the setup, you also need to implement a relay (field supply, see addendum book for optional equipment).
For more information, see:
▪ Installation manual of the heat
pump convectors
▪ Installation manual of the heat
pump convector options
▪ Addendum book for optional
equipment
Wires: 0.75mm²
Maximum running current: 100mA For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
Item Description
Power supply (main) See "6.3.1To connect the main power
supply"[412].
ETVH/X16S18+23EA6V+9W Daikin Altherma 3 H HT F 4P644728-1 – 2021.02
Installation manual
11
6 Electrical installation
1
2
3
A
1 2 3
a
Item Description
Remote outdoor sensor
Remote indoor sensor See:
Human Comfort Interface
WLAN module See:
See:
▪ Installation manual of the remote
▪ Addendum book for optional
Wires: 2×0.75mm²
[9.B.1]=1 (External sensor = Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
▪ Installation manual of the remote
▪ Addendum book for optional
Wires: 2×0.75mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset See:
▪ Installation and operation manual of
▪ Addendum book for optional
Wires: 2×(0.75~1.25mm²)
Maximum length: 500m [2.9] Control
[1.6] Room sensor offset
▪ Installation manual of the WLAN
▪ Addendum book for optional
▪ Installer reference guide Use the cable delivered with the
WLAN module. [D] Wireless gateway
outdoor sensor
equipment
indoor sensor
equipment
the Human Comfort Interface
equipment
module
equipment
In case of… See…
Wired room thermostat with multi-zoning base unit
▪ Installation manual of the wired room
thermostat (digital or analogue) + multi-zoning base unit
▪ Addendum book for optional
equipment
▪ In this case:
▪ You need to connect the wired
room thermostat (digital or analogue) to the multi-zoning base unit
▪ You need to connect the multi-
zoning base unit to the outdoor unit
▪ For cooling/heating operation, you
also need to implement a relay (field supply, see addendum book for optional equipment)

6.3.1 To connect the main power supply

1 Open the following (see "4.2.1To open the indoor unit"[45]):
1 Top panel 2 User interface panel 3 Upper switch box cover
2 Connect the main power supply.
In case of normal kWh rate power supply
Interconnection cable (=main power supply)
Wires: (3+GND)×1.5mm²
WLAN cartridge See:
▪ Installation manual of the WLAN
cartridge
▪ Installer reference guide [D] Wireless gateway
for room thermostat (wired or wireless):
In case of… See…
Wireless room thermostat ▪ Installation manual of the wireless
Wired room thermostat without multi-zoning base unit
Installation manual
12
▪ Addendum book for optional
▪ Installation manual of the wired room
▪ Addendum book for optional
room thermostat
equipment
thermostat
equipment
ETVH/X16S18+23EA6V+9W
Daikin Altherma 3 H HT F
4P644728-1 – 2021.02
Loading...
+ 28 hidden pages