Daikin ETVH16S18DA6V, ETVH16S23DA6V, ETVH16S18DA9W, ETVH16S23DA9W, ETVX16S18DA6V Operation manuals

...
Operation manual
Daikin Altherma 3 H HT F+W
ETVH16S18DA6V(G) ETVH16S23DA6V(G) ETVH16S18DA9W(G) ETVH16S23DA9W(G) ETVX16S18DA6V(G) ETVX16S23DA6V(G) ETVX16S18DA9W(G) ETVX16S23DA9W(G)
ETBH16DF6V ETBH16DF9W ETBX16DF6V ETBX16DF9W
Operation manual
Daikin Altherma 3 H HT F+W
Betriebsanleitung
Daikin Altherma 3 H HT F+W
Manuel d'utilisation
Daikin Altherma 3 H HT F+W
Gebruiksaanwijzing
Daikin Altherma 3 H HT F+W
Manuale d'uso
Daikin Altherma 3 H HT F+W
Betjeningsvejledning
Daikin Altherma 3 H HT F+W
Bruksanvisning
Daikin Altherma 3 H HT F+W
Driftshåndbok
Daikin Altherma 3 H HT F+W
Käyttöopas
Daikin Altherma 3 H HT F+W
English
Deutsch
Français
Italiano
Dansk
Svenska
Norsk
Suomi

Table of contents

Table of contents
1 Installer settings: Tables to be filled in by
installer 2
1.1 Configuration wizard.................................................................. 2
1.2 Settings menu ........................................................................... 2
2 Quick guide 3
2.1 User permission level ................................................................ 3
2.2 Space heating/cooling ............................................................... 3
2.3 Domestic hot water.................................................................... 5
3 General information 6
3.1 About this document.................................................................. 6
3.2 About the system....................................................................... 6
3.2.1 Components in a typical system layout....................... 7
4 Operation 7
4.1 User interface: Overview ........................................................... 7
4.2 Menu structure: Overview user settings .................................... 8
4.3 Possible screens: Overview ...................................................... 9
4.3.1 Home screen............................................................... 9
4.3.2 Main menu screen ...................................................... 10
4.3.3 Setpoint screen........................................................... 10
4.3.4 Detailed screen with values ........................................ 11
4.4 Turning operation ON or OFF ................................................... 11
4.4.1 Visual indication.......................................................... 11
4.4.2 To turn ON or OFF...................................................... 11
4.5 Reading out information ............................................................ 12
To read out information............................................... 12
Possible read-out information ..................................... 12
4.6 Space heating/cooling control ................................................... 12
4.6.1 Setting the space operation mode .............................. 12
4.6.2 To change the desired room temperature................... 12
4.6.3 To change the desired leaving water temperature...... 13
4.7 Domestic hot water control........................................................ 13
4.7.1 Reheat mode .............................................................. 13
4.7.2 Scheduled mode......................................................... 13
4.7.3 Scheduled + reheat mode........................................... 13
4.7.4 Using DHW powerful operation................................... 14
4.8 Schedule screen: Example........................................................ 14
4.9 Weather-dependent curve......................................................... 16
4.9.1 What is a weather-dependent curve? ......................... 16
4.9.2 2-points curve ............................................................. 16
4.9.3 Slope-offset curve....................................................... 16
4.9.4 Using weather-dependent curves ............................... 17
5 Energy saving tips 18 6 Maintenance and service 18
6.1 Overview: Maintenance and service ......................................... 18
7 Troubleshooting 19
7.1 To display the help text in case of a malfunction....................... 19
7.2 To check the malfunction history............................................... 19
7.3 Symptom: You are feeling too cold (hot) in your living room..... 19
7.4 Symptom: The water at the tap is too cold ................................ 19
7.5 Symptom: Heat pump failure..................................................... 19
7.6 Symptom: The system is making gurgling noises after
commissioning........................................................................... 20
8 Disposal 20 9 Glossary 20
1 Installer settings: Tables to be
filled in by installer

1.1 Configuration wizard

Setting Fill in…
System
Indoor unit type (read only) Backup heater type [9.3.1]
(read only)
Domestic hot water [9.2.1] Emergency [9.5] Number of zones [4.4]
Glycol Filled system
(overview field setting [E‑0D])
Booster heater capacity
[9.4.1] (if applicable)
Backup heater
Voltage [9.3.2] Configuration [9.3.3] Capacity step 1 [9.3.4]
Additional capacity step 2
[9.3.5] (if applicable)
Main zone
Emitter type [2.7] Control [2.9] Setpoint mode [2.4] Schedule [2.1] WD curve type [2.E]
Additional zone (only if [4.4]=1, dual zone)
Emitter type [3.7] Control (read only) [3.9] Setpoint mode [3.4] Schedule [3.1] WD curve type [3.C] (read only)
Tank (if applicable)
Heat up mode [5.6] Comfort setpoint [5.2] Eco setpoint [5.3] Reheat setpoint [5.4] Setpoint mode [5.B] WD curve type [5.E] (read only)

1.2 Settings menu

Setting Fill in…
Main zone
Thermostat type [2.A]
Additional zone (if applicable)
Thermostat type [3.A]
Information
Dealer information [8.3]

Operation manual

2
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10

2 Quick guide

User profile
B
0000
User
1234
Advanced user
Operation
Room
Space heating/cooling
On
On
C.1
Operation
Space heating/cooling
Tank
Off
On
On
Room
C.2
Room
1
+
21°C
1
a b
Room
Main zone
2
Additional zone
3
2 Quick guide

2.1 User permission level

The amount of information you can read out and edit in the menu structure depends on your user permission level:
User: Standard mode
Advanced user: You can read out and edit more information
To change the user permission level
1 Go to [B]: User profile.
2 Enter the applicable pin code for the user permission
level. ▪ Browse through the list of digits and change the
selected digit. ▪ Move the cursor from left to right. ▪ Confirm the pin code and proceed.
User pin code
The User pin code is 0000.
NOTICE Water pipe freeze prevention. Even if you turn OFF
space heating/cooling operation ([C.2]: Operation > Space heating/cooling), water pipe freeze prevention –
if enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
2 Set operation to On or Off.
To change the desired room temperature
During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
2 Adjust the desired room temperature.
Advanced user pin code
The Advanced user pin code is 1234. Additional menu items for the user are now visible.

2.2 Space heating/cooling

To turn room temperature control ON or OFF
1 Go to [C.1]: Operation > Room.
2 Set operation to On or Off.
To turn space heating/cooling operation ON or OFF
NOTICE Room frost protection. Even if you turn OFF space
heating/cooling operation ([C.2]: Operation > Space heating/cooling), room frost protection –if enabled– will
remain active.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
a Actual room temperature b Desired room temperature
To change the desired leaving water temperature
You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
Operation manual
3
2 Quick guide
+
35°C
2
a b
Main zone
+
45°C
3
a b
Additional zone
X1 X2
c d
Y1
Y2
Y3
Y4
a b
Y1
Y2
Y3
Y4
X1 X2
a b
c
d
Y1
Y2
X1 X2
2 Adjust the desired leaving water temperature.
a Actual leaving water temperature b Desired leaving water temperature
To change the weather-dependent curve for the space heating/ cooling zones
1 Go to the applicable zone:
Zone Go to …
Main zone – Heating [2.5] Main zone > Heating WD
curve
Main zone – Cooling [2.6] Main zone > Cooling WD
curve
Additional zone – Heating [3.5] Additional zone >
Heating WD curve
Additional zone – Cooling [3.6] Additional zone >
Cooling WD curve
2-points curve
X1, X2 Outdoor ambient temperature Y1, Y2 Desired leaving water temperature
Possible actions on this screen
Go through the temperatures. Change the temperature. Go to the next temperature. Confirm changes and proceed.
More information
For more information, see also: ▪ "4.4Turning operation ON or OFF"[411]"4.6Space heating/cooling control"[412]"4.8Schedule screen: Example"[414]"4.9Weather-dependent curve"[416] ▪ User reference guide
2 Change the weather-dependent curve.
There are 2 types of WD curves: slope-offset curve (default), and 2-points curve. If needed, you can change the type in [2.E] Main zone > WD curve type. The way to adjust the curve depends on the type.
Slope-offset curve
Slope. When slope is changed,
the new preferred temperature at X1 is unequally higher than the preferred temperature at X2.
X1, X2 Outdoor ambient temperature Y1~Y4 Desired leaving water temperature
a WD curve before changes b WD curve after changes c Slope d Offset
Offset. When offset is changed,
the new preferred temperature at X1 is equally higher as the preferred temperature at X2.
Possible actions on this screen
Select slope or offset. Increase or decrease the slope/offset. When slope is selected: set slope and go to offset.
When offset is selected: set offset. Confirm changes and return to the submenu.
Operation manual
4
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10

2.3 Domestic hot water

Operation
Tank
Off
On
Space heating/cooling
C.3
Tank
5
+
50°C
5
a b
Tank
To turn tank heating operation ON or OFF
NOTICE Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will remain active. However, if you turn it OFF while disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
2 Set operation to On or Off.
To change the tank temperature setpoint
In Reheat only mode, you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature.
1 Go to [5]: Tank.
2 Quick guide
2 Adjust the domestic hot water temperature.
a Actual domestic hot water temperature b Desired domestic hot water temperature
In other modes, you can only view the setpoint screen but not modify it. Instead, you can modify the settings for the Comfort setpoint [5.2], Eco setpoint [5.3] and Reheat setpoint [5.4].
More information
For more information, see also: ▪ "4.4Turning operation ON or OFF"[411]"4.7Domestic hot water control"[413]"4.8Schedule screen: Example"[414] ▪ User reference guide
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Operation manual
5

3 General information

4
Space heating/cooling
Operation range
4.3
3 General information

3.1 About this document

Thank you for purchasing this product. Please: ▪ Read the documentation carefully before operating the user
interface to ensure the best possible performance.
▪ Request the installer to inform you about the settings that he used
to configure your system. Check if he has filled in the installer settings tables. If not, request him to do so.
▪ Keep the documentation for future reference.
Target audience
Endusers
Documentation set
This document is part of a documentation set. The complete set consists of:
General safety precautions:
▪ Safety instructions that you must read before installing ▪ Format: Paper (in the box of the indoor unit)
Operation manual:
▪ Quick guide for basic usage ▪ Format: Paper (in the box of the indoor unit)
User reference guide:
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Installation manual – Outdoor unit:
▪ Installation instructions ▪ Format: Paper (in the box of the outdoor unit)
Installation manual – Indoor unit:
▪ Installation instructions ▪ Format: Paper (in the box of the indoor unit)
Installer reference guide:
▪ Preparation of the installation, good practices, reference
data,…
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Addendum book for optional equipment:
▪ Additional info about how to install optional equipment ▪ Format: Paper (in the box of the indoor unit) + Digital files on
http://www.daikineurope.com/support-and-manuals/product­information/
Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer.
The original documentation is written in English. All other languages are translations.
Daikin Residential Controller app
If set up by your installer, you can use the Daikin Residential Controller app to control and monitor the status of your system. For more information, see:
http://www.onlinecontroller.daikineurope.com/
Breadcrumbs
Breadcrumbs (example: [4.3]) help you to locate where you are in the menu structure of the user interface.
1 To enable the breadcrumbs: In the home screen or
main menu screen, press the help button. The breadcrumbs appear in the top left corner of the screen.
2 To disable the breadcrumbs: Press the help button
again.
This document also mentions these breadcrumbs. Example:
1 Go to [4.3]: Space heating/cooling > Operation
range.
This means:
1 Starting from the home screen, turn the left dial and
go to Space heating/cooling.
2 Press the left dial to enter the submenu. 3 Turn the left dial and go to Operation range.
4 Press the left dial to enter the submenu.

3.2 About the system

Depending on the system layout, the system can: ▪ Heat up a space ▪ Cool down a space (if a heating/cooling heat pump model is
installed)
▪ Produce domestic hot water (if a DHWtank is installed)
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models ▪ Heating only models + conversion kit
Operation manual
6
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10

4 Operation

g
A
db
a
f
e
c
BC
b
c
a
a
b c
a b c d e
3.2.1 Components in a typical system layout
A Main zone. Example: Living room. B Additional zone. Example: Bedroom. C Technical room. Example: Garage.
a Outdoor unit heatpump b Indoor unit heatpump c Domestic hot water (DHW) tank d User interface of the indoor unit e Dedicated Human Comfort Interface (BRC1HHDA used as
room thermostat)
f Underfloor heating
g Radiators, heatpump convectors, or fancoil units
INFORMATION
The indoor unit and the domestic hot water tank (if installed) can be separated or integrated depending on the indoor unit type.
Status indicator
The LEDs of the status indicator light up or blink to show the operating mode of the unit.
LED Mode Description
Blinking blue Standby The unit is not in operation. Continuous blue Operation The unit is in operation. Blinking red Malfunction A malfunction occurred.
See "7.1To display the help text
in case of a malfunction"[419]
for more information.
LCD screen
The LCD screen has a sleeping function. After 15 min of non­interaction with the user interface, the screen darkens. Pressing any button or rotating any dial awakens the display.
Dials and buttons
You use the dials and buttons: ▪ To navigate through the screens, menus and settings of the LCD
screen
▪ To set values
4 Operation
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models ▪ Heating only models + conversion kit

4.1 User interface: Overview

The user interface has the following components:
a Status indicator b LCD screen c Dials and buttons
Item Description
a Left dial The LCD shows an arc on the left side of the
display when you can use the left dial. ▪ : Turn, then press the left dial. Navigate
through the menu structure. ▪ : Turn the left dial. Choose a menu item. ▪ : Press the left dial. Confirm your choice
or go to a submenu.
b Back button : Press to go back 1 step in the menu structure. c Home
button
d Help button : Press to show a help text related to the current
e Right dial The LCD shows an arc on the right side of the
: Press to go back to the home screen.
page (if available).
display when you can use the right dial. ▪ : Turn, then press the right dial. Change
a value or setting, shown at the right side of the
screen. ▪ : Turn the right dial. Navigate through
the possible values and settings. ▪ : Press the right dial. Confirm your
choice and go to the next menu item.
a Status indicator b LCD screen c Dials and buttons
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Operation manual
7
4 Operation
[1]
Room
Room sensor offset
Setpoint range
Antifrost
Cooling schedule
Heating schedule
Schedule
[2]
Main zone Schedule
Heating schedule
Setpoint mode
Cooling schedule
Heating WD curve Cooling WD curve WD curve type
[3]
Additional zone Schedule
Heating schedule
Setpoint mode
Cooling schedule
Heating WD curve Cooling WD curve WD curve type
[4]
Space heating/cooling
Operation mode Operation mode schedule
[7]
User settings Language
Time/date Holiday Quiet Electricity price Gas price
[8]
Information Energy data
Malfunction history Dealer information Sensors Actuators Operation modes About Connection status Running hours
[B]
User profile
[C]
Operation
Room Space heating/cooling Tank
[1.4]
Antifrost
Activation Room setpoint
[1.5]
Setpoint range Heating minimum
Heating maximum Cooling minimum Cooling maximum
[7.2]
Time/date
Hours Minutes Year Month Day Daylight savings time Format
[7.3]
Holiday
Activation From Till
[7.4]
Quiet
Activation Schedule Level
[7.5]
Electricity price
High Medium Low Schedule
[8.1]
Energy data
Electricity input Produced heat
(**)
(**)
[5]
Tank
Powerful operation Comfort setpoint Eco setpoint Reheat setpoint Schedule WD curve WD curve type
(*) (*)
(*)
(*)
(*)
(*)
(*)
(*)
[D]
Wireless gateway
Mode WPS Reboot Device info
(***)

4.2 Menu structure: Overview user settings

Operation manual
8
Setpoint screen
(*) Only applicable for reversible models, or heating only models + conversion kit
(**) Only accessible by installer
(***) Only applicable when WLAN adapter is installed
INFORMATION
Depending on the selected installer settings and unit type, settings will be visible/invisible.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
4 Operation
+
a
OR
b
c
c2
c4
c1
c3
6
1.6
bar
26 Feb 2019
22:19
55
21
35
j
e2
l
k1
k2 k3
45
d
e1
g3
g2
h1
g1
f
i2 i3 i4 h2i1
a2a1e3 b c
55
6
21
35

4.3 Possible screens: Overview

The most common screens are as follows:
Item Description
b Disinfection / Powerful
Disinfection mode active
Powerful operation mode active
c Emergency
Heat pump failure and system operates in Emergency mode or heat pump is forced off.
d Current date and time
e Smart energy
e1 Smart energy is available via solar panels or smart
grid.
e2 Smart energy is currently being used for space
heating.
e3 Smart energy is currently being used for domestic
hot water.
f Space operation mode
Cooling
Heating
g Outdoor / quiet mode
g1
Measured outdoor temperature
(a)
g2 Quiet mode active
g3 Outdoor unit
h Indoor unit / domestic hot water tank
a Home screen b Main menu screen c Lower level screens:
c1: Setpoint screen c2: Detailed screen with values c3: Screen with weather-dependent curve c4: Screen with schedule
h1 Floor-standing indoor unit with integrated tank
Wall-mounted indoor unit
Wall-mounted indoor unit with separated tank
4.3.1 Home screen
Press the button to go back to the home screen. You see an overview of the unit configuration and the room and setpoint temperatures. Only symbols applicable for your configuration are visible on the home screen.
Possible actions on this screen
Go through the list of the main menu. Go to the main menu screen. Enable/disable breadcrumbs.
Item Description
a Domestic hot water
a1 Domestic hot water
a2
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Measured tank temperature
(a)
h2 Water pressure
i Main zone
i1 Installed room thermostat type:
Unit operation is decided based on the ambient temperature of the dedicated Human Comfort Interface (BRC1HHDA used as room thermostat).
Unit operation is decided by the external room thermostat (wired or wireless).
No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature regardless of the actual room temperature and/or heating demand of the room.
i2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
i3
i4
Measured room temperature
Leaving water temperature setpoint
j Holiday mode
Holiday mode active
(a)
(a)
Operation manual
9
4 Operation
45
a
2
Main zone
Additional zone
Room
Malfunctioning
Space heating/cooling
+
21°C
1
Room
+
35°C
2
Main zone
+
45°C
3
Additional zone
+
50°C
5
Tank
a1
d
+
d
e
d
e
c
a2
b1
b2
Item Description
k Additional zone
k1 Installed room thermostat type:
Unit operation is decided by the external room thermostat (wired or wireless).
No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature regardless of the actual room temperature and/or heating demand of the room.
k2 Installed heat emitter type:
Underfloor heating
Fancoil unit
Radiator
k3
l Malfunction
(a)
Leaving water temperature setpoint
A malfunction occurred. See "7.1To display the help text in case of a
malfunction"[419] for more information.
If the corresponding operation (for example: space heating) is not active, the circle is greyed out.
(a)
4.3.2 Main menu screen
Starting from the home screen, press ( ) or turn ( ) the left dial to open the main menu screen. From the main menu, you can access the different setpoint screens and submenus.
Submenu Description
[4]
Space heating/
cooling
[5]
Tank
[7]
User settings
[8]
Information
[9]
Installer
settings
[A]
Commissioning
[B]
User profile
[C]
Operation
[D]
Wireless
gateway
Shows the applicable symbol of your unit.
Put the unit in heating mode or cooling mode. You cannot change the mode on heating only models.
Set the domestic hot water tank temperature.
Gives access to user settings such as holiday mode and quiet mode.
Displays data and information about the indoor unit.
Restriction: Only for the installer. Gives access to advanced settings.
Restriction: Only for the installer. Perform tests and maintenance.
Change the active user profile.
Turn heating/cooling functionality and domestic hot water preparation on or off.
Restriction: Only displayed if a wireless LAN (WLAN) is installed.
Contains settings needed when configuring the Daikin Residential Controller app.
4.3.3 Setpoint screen
The setpoint screen is displayed for screens describing system components that need a setpoint value.
Examples
[1] Room temperature screen
[2] Main zone screen
a Selected submenu
Possible actions on this screen
Go through the list. Enter the submenu. Enable/disable breadcrumbs.
Submenu Description
[0]
or
Malfunctioning
[1]
Room
[2]
Main zone
[3]
Additional zone
Restriction: Only displayed if a malfunction occurs.
See "7.1To display the help text in
case of a malfunction"[419] for more
information. Restriction: Only displayed if a
dedicated Human Comfort Interface (BRC1HHDA used as room thermostat) is controlling the indoor unit.
Set the room temperature. Shows the applicable symbol for your
main zone emitter type. Set the leaving water temperature for
the main zone. Restriction: Only displayed if there
are two leaving water temperature zones. Shows the applicable symbol for your additional zone emitter type.
Set the leaving water temperature for the additional zone (if present).
[3] Additional zone screen
Explanation
Possible actions on this screen
Go through the list of the submenu. Go to the submenu. Adjust and automatically apply the desired
temperature.
[5] Tank temperature screen
Operation manual
10
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
4 Operation
a bc
a bc
7.2.1
Time/date
Hours
11
30
Minutes
1.6
bar
55
21
35
45
a
1.6 bar
55
21
35
45
b
1.6 bar
55
21
35
45
c
1.6 bar
55
21
35
45
d
1.6 bar
55
21
35
45
e
1.6 bar
55
21
35
45
f
Operation
Room
Space heating/cooling
On
On
C.1
Operation
Space heating/cooling
Tank
Off
On
On
Room
C.2
Item Description
Minimum temperature limit a1 Fixed by the unit
a2 Restricted by the installer
Maximum temperature limit b1 Fixed by the unit
b2 Restricted by the installer
Current temperature c Measured by the unit Desired temperature d Turn the right dial to
increase/decrease.
Submenu e Turn or press the left dial to
go to the submenu.
4.3.4 Detailed screen with values
Example:
a Settings b Values c Selected setting and value
Possible actions on this screen
Go through the list of settings. Change the value. Go to the next setting. Confirm changes and proceed.

4.4 Turning operation ON or OFF

Space heating/cooling operation
c Space heating/cooling operation ON d Space heating/cooling operation OFF
Tank heating operation
e Tank heating operation ON
f Tank heating operation OFF
4.4.2 To turn ON or OFF
Room temperature control
1 Go to [C.1]: Operation > Room.
4.4.1 Visual indication
Certain functionalities of the unit can be enabled or disabled separately. If a functionality is disabled, the corresponding temperature icon in the home screen will be greyed out.
Room temperature control
a Room temperature control ON b Room temperature control OFF
2 Set operation to On or Off.
Space heating/cooling operation
NOTICE Room frost protection. Even if you turn OFF space
heating/cooling operation ([C.2]: Operation > Space heating/cooling), room frost protection –if enabled– will
remain active.
NOTICE Water pipe freeze prevention. Even if you turn OFF
space heating/cooling operation ([C.2]: Operation > Space heating/cooling), water pipe freeze prevention –
if enabled– will remain active.
1 Go to [C.2]: Operation > Space heating/cooling.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
2 Set operation to On or Off.
Operation manual
11
4 Operation
Operation
Tank
Off
On
Space heating/cooling
C.3
Room
1
+
21°C
1
a b
Room
Tank heating operation
NOTICE Disinfection mode. Even if you turn OFF tank heating
operation ([C.3]: Operation > Tank), disinfection mode will remain active. However, if you turn it OFF while disinfection is running, an AH error occurs.
1 Go to [C.3]: Operation > Tank.
2 Set operation to On or Off.

4.5 Reading out information

To read out information
1 Go to [8]: Information.
Possible read-out information
In menu… You can read out…
[8.1] Energy data Produced energy, consumed
electricity, and consumed gas [8.2] Malfunction history Malfunction history [8.3] Dealer information Contact/helpdesk number [8.4] Sensors Room, tank or domestic hot
water, outside, and leaving water
temperature (if applicable) [8.5] Actuators Status/mode of each actuator
Example: Domestic hot water
pump ON/OFF [8.6] Operation modes Current operation mode
Example: Defrost/oil return
mode [8.7] About Version information about the
system [8.8] Connection status Information about the connection
status of the unit, the room
thermostat and the LAN adapter. [8.9] Running hours Running hours of specific system
components
To set the space operation mode
1 Go to [4.1]: Space heating/cooling > Operation
mode
2 Select one of the following options:
Heating: Only heating mode
Cooling: Only cooling mode
Automatic: The operation mode changes
automatically between heating and cooling based on the outdoor temperature. Restricted per month according to the Operation mode schedule [4.2].
To restrict automatic changeover according to a schedule Conditions: You set the space operation mode to Automatic.
1 Go to [4.2]: Space heating/cooling > Operation
mode schedule.
2 Select a month. 3 For each month, select an option:
Reversible: Not restricted
Heating only: Restricted
Cooling only: Restricted
4 Confirm the changes.
4.6.2 To change the desired room temperature
During room temperature control, you can use the room temperature setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
2 Adjust the desired room temperature.

4.6 Space heating/cooling control

4.6.1 Setting the space operation mode
About space operation modes
Your unit can be a heating or a heating/cooling model: ▪ If your unit is a heating model, it can heat up a space. ▪ If your unit is a heating/cooling model, it can both heat up and cool
To tell the system which space operation to use, you can:
Check which space operation mode is currently used.
Set the space operation mode permanently. Main menu Restrict automatic changeover according to
a monthly schedule.
Operation manual
12
down a space. You have to tell the system which operation mode to use.
You can… Location
Home screen
a Actual room temperature b Desired room temperature
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off scheduling.
To turn off room temperature scheduling
1 Go to [1.1]: Room > Schedule. 2 Select No.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
4 Operation
Main zone
2
Additional zone
3
+
35°C
2
a b
Main zone
+
45°C
3
a b
Additional zone
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
T
t
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
5
T
t
t
T
t
60°C
00:00 07:00
50°C 45°C
15°C
14:00 21:00
35°C
1
2
4
5
3
4.6.3 To change the desired leaving water temperature
INFORMATION
The leaving water is the water that is sent to the heat emitters. The desired leaving water temperature is set by your installer in accordance with the heat emitter type. Only adjust the leaving water temperature settings in case of problems.
You can use the leaving water temperature setpoint screen to read out and adjust the desired leaving water temperature.
1 Go to [2]: Main zone or [3]: Additional zone.
2 Adjust the desired leaving water temperature.
INFORMATION
Risk of space heating capacity shortage for domestic hot water tank without internal booster heater: In case of frequent domestic hot water operation, frequent and long space heating/cooling interruption will happen when selecting the following:
Tank > Heat up mode > Reheat only.
INFORMATION
When the DHW tank mode is reheat, the risk for capacity shortage and comfort problem is significant. In case of frequent reheat operation, space heating/cooling function is regularly interrupted.
4.7.2 Scheduled mode
In scheduled mode the DHWtank produces hot water corresponding to a schedule. The best time to allow the tank to produce hot water is at night, because the space heating demand is lower.
Example:
a Actual leaving water temperature b Desired leaving water temperature

4.7 Domestic hot water control

4.7.1 Reheat mode
In reheat mode the DHW tank continuously heats up to the temperature shown on the home screen (example: 50°C) when the temperature drops below a certain value.
TtDHWtank temperature
t Time
▪ Initially, the DHW tank temperature is the same as the
temperature of the domestic water entering the DHW tank (example: 15°C).
▪ At 00:00 the DHWtank is programmed to heat up the water to a
preset value (example: Comfort = 60°C).
▪ During the morning, you consume hot water and the DHW tank
temperature decreases.
▪ At 14:00 the DHWtank is programmed to heat up the water to a
preset value (example: Eco = 50°C). Hot water is available again.
▪ During the afternoon and evening, you consume hot water again
and the DHWtank temperature decreases again.
▪ At 00:00 the next day, the cycle repeats.
4.7.3 Scheduled + reheat mode
In scheduled + reheat mode, the domestic hot water control is the same as in scheduled mode. However, when the DHW tank temperature drops below a preset value (=reheat tank temperature – hysteresis value; example: 35°C), the DHWtank heats up until it reaches the reheat set point (example: 45°C). This ensures that a minimum amount of hot water is available at all times.
Example:
TtDHWtank temperature
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
t Time
TtDomestic hot water tank temperature
t Time
Operation manual
13
4 Operation
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Delete
Rename Select
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
C
Delete
Edit
Copy
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Delete
Edit
Copy
4.7.4 Using DHW powerful operation
About powerful operation
Powerful operation allows the domestic hot water to be heated by the backup heater or booster heater. Use this mode on days when there is more hot water usage than usual.
To check if powerful operation is active
If is displayed on the home screen, powerful operation is active. Activate or deactivate Powerful operation as follows:
1 Go to [5.1]: Tank > Powerful operation 2 Turn powerful operation Off or On.
Usage example: You immediately need more hot water
You are in the following situation: ▪ You already consumed most of your domestic hot water. ▪ You cannot wait for the next scheduled action to heat up the
domestic hot water tank.
Then you can activate powerful operation. The domestic hot water tank will start heating up the water to the Comfort temperature.
INFORMATION
When powerful operation is active, the risk of space heating/cooling and capacity shortage comfort problems is significant. In case of frequent domestic hot water operation, frequent and long space heating/cooling interruptions will happen.

4.8 Schedule screen: Example

This example shows how to set a room temperature schedule in heating mode for the main zone.
To clear the content of the week schedule
1 Select the name of the current schedule.
2 Select Delete.
3 Select OK to confirm.
To clear the content of a day schedule
1 Select the day of which you want to clear the
content. For example Friday
2 Select Delete.
INFORMATION
The procedures to program other schedules are similar.
To program the schedule: overview Example: You want to program the following schedule:
Prerequisite: The room temperature schedule is only available if
room thermostat control is active. If leaving water temperature control is active, you can program the main zone schedule instead.
1 Go to the schedule. 2 (optional) Clear the content of the whole week schedule or the
content of a selected day schedule.
3 Program the schedule for Monday. 4 Copy the schedule to the other weekdays. 5 Program the schedule for Saturday and copy it to Sunday. 6 Give the schedule a name.
To go to the schedule
1 Go to [1.1]: Room > Schedule. 2 Set scheduling to Yes. 3 Go to [1.2]: Room > Heating schedule.
3 Select OK to confirm.
To program the schedule for Monday
1 Select Monday.
2 Select Edit.
Operation manual
14
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
4 Operation
0
6:00
8:30
17:30
20°C
18°C
22:00
--:--
18°C
--
21°C
12 24
Mon
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Delete
Edit
Copy
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
C
Delete
Edit
Copy
Paste
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
C
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
C
0
8:00
23:00
--:--
21°C
18°C
--
12 24
Sat
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
C
Mon
Sat
Wed
Fri
Thu
Tue
Sun
User defined 1
Delete
Rename
Select
3 Use the left dial to select an entry and edit the entry
with the right dial. You can program up to 6 actions each day. On the bar, a high temperature has a darker colour than a low temperature.
Note: To clear an action, set its time as the time of the previous action.
4 Confirm the changes.
Result: The schedule for Monday is defined. The
value of the last action is valid until the next programmed action. In this example, Monday is the first day you programmed. Thus, the last programmed action is valid up to the first action of next Monday.
To copy the schedule to the other weekdays
1 Select Monday.
5 Repeat this action for all other weekdays.
To program the schedule for Saturday and copy it to Sunday
1 Select Saturday. 2 Select Edit. 3 Use the left dial to select an entry and edit the entry
with the right dial.
4 Confirm the changes. 5 Select Saturday. 6 Select Copy. 7 Select Sunday. 8 Select Paste.
Result:
2 Select Copy.
Result: Next to the copied day, "C" is displayed.
3 Select Tuesday.
4 Select Paste.
Result:
To rename the schedule
1 Select the name of the current schedule.
2 Select Rename.
3 (optional) To delete the current schedule name,
browse through the character list until is displayed, then press to remove the previous character. Repeat for each character of the schedule name.
4 To name the current schedule, browse through the
character list and confirm the selected character. The schedule name can contain up to 15characters.
5 Confirm the new name.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
INFORMATION
Not all schedules can be renamed.
Operation manual
15
4 Operation
Y1
Y2
X1 X2
a
X1 X2
c
d
e
Y1
Y2
Y3
Y4
a b

4.9 Weather-dependent curve

4.9.1 What is a weather-dependent curve?
Weather-dependent operation
The unit operates 'weather dependent' if the desired leaving water or tank temperature is determined automatically by the outdoor temperature. It therefore is connected to a temperature sensor on the North wall of the building. If the outdoor temperature drops or rises, the unit compensates instantly. Thus, the unit does not have to wait for feedback by the thermostat to increase or decrease the temperature of the leaving water or tank. Because it reacts more quickly, it prevents high rises and drops of the indoor temperature and water temperature at tap points.
Advantage
Weather-dependent operation reduces energy consumption.
Weather-dependent curve
To be able to compensate for differences in temperature, the unit relies on its weather-dependent curve. This curve defines how much the temperature of the tank or leaving water must be at different outdoor temperatures. Because the slope of the curve depends on local circumstances such as climate and the insulation of the house, the curve can be adjusted by an installer or user.
Types of weather-dependent curve
There are 2 types of weather-dependent curves: ▪ 2-points curve ▪ Slope-offset curve Which type of curve you use to make adjustments, depends on your
personal preference. See "Using weather-dependent curves"[417].
Availability
The weather-dependent curve is available for: ▪ Main zone - Heating ▪ Main zone - Cooling ▪ Additional zone - Heating ▪ Additional zone - Cooling ▪ Tank (only available to installers)
INFORMATION
To operate weather dependent, correctly configure the setpoint of the main zone, additional zone or tank. See
"Using weather-dependent curves"[417].
Item Description
a Selected weather dependent zone:
: Main zone or additional zone heating
: Main zone or additional zone cooling
: Domestic hot water
X1, X2 Examples of outdoor ambient temperature Y1, Y2 Examples of desired tank temperature or leaving water
temperature. The icon corresponds to the heat emitter for that zone:
: Underfloor heating
: Fan coil unit
: Radiator
: Domestic hot water tank
Possible actions on this screen
Go through the temperatures. Change the temperature. Go to the next temperature. Confirm changes and proceed.
4.9.3 Slope-offset curve
Slope and offset
Define the weather-dependent curve by its slope and offset: ▪ Change the slope to differently increase or decrease the
temperature of the leaving water for different ambient temperatures. For example, if leaving water temperature is in general fine but at low ambient temperatures too cold, raise the slope so that leaving water temperature is heated increasingly more at decreasingly lower ambient temperatures.
▪ Change the offset to equally increase or decrease the
temperature of the leaving water for different ambient temperatures. For example, if leaving water temperature is always a bit too cold at different ambient temperatures, shift the offset up to equally increase the leaving water temperature for all ambient temperatures.
Examples
Weather-dependent curve when slope is selected:
4.9.2 2-points curve
Define the weather-dependent curve with these two setpoints: ▪ Setpoint (X1, Y2) ▪ Setpoint (X2, Y1)
Example
Operation manual
16
Weather-dependent curve when offset is selected:
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
Y1
Y2
Y3
Y4
X1 X2
a b
c
d
e
Item Description
a WD curve before changes. b WD curve after changes (as example):
▪ When slope is changed, the new preferred
temperature at X1 is unequally higher than the preferred temperature at X2.
▪ When offset is changed, the new preferred
temperature at X1 is equally higher as the preferred temperature at X2.
c Slope d Offset e Selected weather dependent zone:
: Main zone or additional zone heating
: Main zone or additional zone cooling
: Domestic hot water
X1, X2 Examples of outdoor ambient temperature
Y1, Y2,
Y3, Y4
Examples of desired tank temperature or leaving water temperature. The icon corresponds to the heat emitter for that zone:
: Underfloor heating
: Fan coil unit
: Radiator
: Domestic hot water tank
Possible actions on this screen
Select slope or offset. Increase or decrease the slope/offset. When slope is selected: set slope and go to offset.
When offset is selected: set offset. Confirm changes and return to the submenu.
4.9.4 Using weather-dependent curves
Configure weather-dependent curves as following:
To define the setpoint mode
To use the weather-dependent curve, you need to define the correct setpoint mode:
Go to setpoint mode … Set the setpoint mode to …
Main zone – Heating
[2.4] Main zone > Setpoint mode
Main zone – Cooling
[2.4] Main zone > Setpoint mode
WD heating, fixed cooling OR Weather dependent
Weather dependent
4 Operation
Go to setpoint mode … Set the setpoint mode to …
Additional zone – Heating
[3.4] Additional zone > Setpoint mode
Additional zone – Cooling
[3.4] Additional zone > Setpoint mode
Tank [5.B] Tank > Setpoint mode Restriction: Only available to
To change the type of weather-dependent curve
To change the type for all zones (main + additional) and for the tank, go to [2.E] Main zone > WD curve type.
Viewing which type is selected is also possible via: ▪ [3.C] Additional zone > WD curve type
▪ [5.E] Tank > WD curve type
Restriction: Only available to installers.
To change the weather-dependent curve
Zone Go to …
Main zone – Heating [2.5] Main zone > Heating WD
Main zone – Cooling [2.6] Main zone > Cooling WD
Additional zone – Heating [3.5] Additional zone >
Additional zone – Cooling [3.6] Additional zone >
Tank Restriction: Only available to
INFORMATION Maximum and minimum setpoints
You cannot configure the curve with temperatures that are higher or lower than the set maximum and minimum setpoints for that zone or for the tank. When the maximum or minimum setpoint is reached, the curve flattens out.
To fine-tune the weather-dependent curve: slope-offset curve
The following table describes how to fine-tune the weather­dependent curve of a zone or tank:
You feel … Fine-tune with slope and
At regular outdoor
temperatures …
OK Cold
OK Hot — Cold OK ↑ Cold Cold ↑ Cold Hot
Hot OK ↓ Hot Cold ↓ Hot Hot
To fine-tune the weather-dependent curve: 2-points curve
The following table describes how to fine-tune the weather­dependent curve of a zone or tank:
At cold outdoor
temperatures …
WD heating, fixed cooling OR Weather dependent
Weather dependent
installers.
Weather dependent
curve
curve
Heating WD curve
Cooling WD curve
installers. [5.C] Tank > WD curve
offset:
Slope Offset
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Operation manual
17

5 Energy saving tips

You feel … Fine-tune with
setpoints:
At regular outdoor
temperatures …
OK Cold
OK Hot — Cold OK ↑ Cold Cold ↑ Cold Hot
Hot OK
Hot Cold
Hot Hot
(a)
See "2-points curve"[416].
At cold outdoor
temperatures …
(a)Y1(a)X1(a)X2(a)
Y2
5 Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high (in
heating mode) or too low (in cooling mode), but ALWAYS according to your actual needs. Each saved degree can save up to 6% of heating/cooling costs.
▪ Do NOT increase/decrease the desired room temperature to
speed up space heating/cooling. The space will NOT heat up/cool down faster.
▪ When your system layout contains slow heat emitters (example:
underfloor heating), avoid large fluctuation of the desired room temperature and do NOT let the room temperature drop too low/ rise too high. It will take more time and energy to heat up/cool down the room again.
▪ Use a weekly schedule for your normal space heating or cooling
needs. If necessary, you can easily deviate from the schedule: ▪ For shorter periods: You can overrule the scheduled room
temperature until the next scheduled action. Example: When you have a party, or when you are leaving for a couple of hours.
▪ For longer periods: You can use the holiday mode.
Tips about DHWtank temperature
▪ Use a weekly schedule for your normal domestic hot water needs
(only in scheduled mode). ▪ Program to heat up the DHWtank to a preset value (Comfort =
higher DHWtank temperature) during the night, because then space heating demand is lower.
▪ If heating up the DHW tank once at night is not sufficient,
program to additionally heat up the DHWtank to a preset value (Eco = lower DHWtank temperature) during the day.
▪ Make sure the desired DHW tank temperature is NOT too high.
Example: After installation, lower the DHWtank temperature daily by 1°C and check if you still have enough hot water.
▪ Program to turn ON the domestic hot water pump only during
periods of the day when instant hot water is necessary. Example: In the morning and evening.

6 Maintenance and service

6.1 Overview: Maintenance and service

The installer has to perform a yearly maintenance. You can find the contact/helpdesk number via the user interface.
1 Go to [8.3]: Information > Dealer information.
As enduser, you have to: ▪ Keep the area around the unit clean. ▪ Keep the user interface clean with a soft damp cloth. Do NOT use
any detergents.
▪ Regularly check if the water pressure is above 1bar.
Refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent gases into the atmosphere.
Refrigerant type: R32 Global warming potential (GWP) value: 675
NOTICE
Applicable legislation on fluorinated greenhouse gases requires that the refrigerant charge of the unit is indicated both in weight and CO2 equivalent.
Formula to calculate the quantity in CO2 equivalent tonnes: GWP value of the refrigerant × total refrigerant
charge [in kg] / 1000 Please contact your installer for more information.
WARNING: FLAMMABLE MATERIAL
The refrigerant inside this unit is mildly flammable.
WARNING
The appliance shall be stored in a room without continuously operating ignition sources (example: open flames, an operating gas appliance or an operating electric heater).
WARNING
▪ Do NOT pierce or burn refrigerant cycle parts. ▪ Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended by the manufacturer.
▪ Be aware that the refrigerant inside the system is
odourless.
WARNING
The refrigerant inside the unit is mildly flammable, but normally does NOT leak. If the refrigerant leaks in the room and comes in contact with fire from a burner, a heater, or a cooker, this may result in fire, or the formation of a harmful gas.
Turn off any combustible heating devices, ventilate the room, and contact the dealer where you purchased the unit.
Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired.
Operation manual
18
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10

7 Troubleshooting

7 Troubleshooting
Contact
For the symptoms listed below, you can try to solve the problem yourself. For any other problem, contact your installer. You can find the contact/helpdesk number via the user interface.
1 Go to [8.3]: Information > Dealer information.

7.1 To display the help text in case of a malfunction

In case of a malfunction, the following will appear on the home screen depending on the severity:
: Error
: Malfunction You can get a short and a long description of the malfunction as
follows:
1 Press the left dial to open the main menu and go to
Malfunctioning. Result: A short description of the error and the error
code is displayed on the screen.
2 Press in the error screen.
Result: A long description of the error is displayed
on the screen.

7.2 To check the malfunction history

Conditions: The user permission level is set to advanced end user.
1 Go to [8.2]: Information > Malfunction history.
You see a list of the most recent malfunctions.

7.3 Symptom: You are feeling too cold (hot) in your living room

Possible cause Corrective action
The desired room temperature is too low (high).
The desired room temperature cannot be reached.
The weather-dependent curve is set incorrectly.
Increase (decrease) the desired room temperature. See "To
change the desired room temperature"[412].
If the problem recurs daily, do one of the following:
▪ Increase (decrease) the room
temperature preset value. See the user reference guide.
▪ Adjust the room temperature
schedule. See "4.8 Schedule
screen: Example"[414].
Increase the desired leaving water temperature in accordance with the heat emitter type. See
"To change the desired leaving water temperature"[413].
Adjust the weather-dependent curve. See "4.9Weather-
dependent curve"[416].

7.4 Symptom: The water at the tap is too cold

Possible cause Corrective action
You ran out of domestic hot water because of unusual high consumption.
The desired DHWtank temperature is too low.
If you immediately need domestic hot water, activate the DHW tank Powerful operation. However, this consumes extra energy. See
"Using DHW powerful operation"[414].
If the problems recurs daily, do one of the following:
▪ Increase the DHW tank
temperature preset value. See the user reference guide.
▪ Adjust the DHW tank
temperature schedule. Example: Program to additionally heat up the DHW tank to a preset value (Eco setpoint = lower tank temperature) during the day. See "4.8 Schedule screen:
Example"[414].

7.5 Symptom: Heat pump failure

When the heat pump fails to operate, the backup heater and/or booster heater can serve as an emergency heater. It then takes over the heat load either automatically or by manual interaction.
▪ When Emergency is set to Automatic and a heat pump failure
occurs: ▪ For ETVH/X: The backup heater automatically takes over the
domestic hot water production and space heating.
▪ For ETBH/X: The backup heater automatically takes over the
heat load, and the booster heater in the optional tank takes over the domestic hot water production.
▪ When Emergency is set to Manual and a heat pump failure
occurs, the domestic hot water heating and space heating stops. To manually recover it via the user interface, go to the
Malfunctioning main menu screen and confirm whether the backup heater and/or booster heater can take over the heat load or not.
▪ Alternatively, when Emergency is set to:
auto SH reduced/DHW on, space heating is reduced but
domestic hot water is still available.
auto SH reduced/DHW off, space heating is reduced and
domestic hot water is NOT available.
auto SH normal/DHW off, space heating operates as
normally but domestic hot water is NOT available.
Similarly as in Manual mode, the unit can take the full load with the backup heater and/or booster heater if the user activates this via the Malfunctioning main menu screen.
When the heat pump fails, or will appear on the user interface.
Possible cause Corrective action
Heat pump is damaged. See "7.1To display the help text
in case of a malfunction"[419].
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
INFORMATION
When the backup heater or booster heater takes over the heat load, electricity consumption will be considerably higher.
Operation manual
19

8 Disposal

7.6 Symptom: The system is making gurgling noises after commissioning

Possible cause Corrective action
There is air in the system. Purge air from the system. Various malfunctions.
(a)
We recommend to purge air with the air purge function of the unit (to be performed by the installer). If you purge air from the heat emitters or collectors, mind the following:
WARNING Air purging heat emitters or collectors. Before you
purge air from heat emitters or collectors, check if or
is displayed on the home screen of the user interface.
▪ If not, you can purge air immediately. ▪ If yes, make sure that the room where you want to
purge air is sufficiently ventilated. Reason: Refrigerant might leak into the water circuit, and subsequently into the room when you purge air from the heat emitters or collectors.
Check if or is displayed on the home screen of the user interface. See "7.1To display the
help text in case of a malfunction"[419] for more
information about the malfunction.
8 Disposal
(a)
NOTICE
Do NOT try to dismantle the system yourself: dismantling of the system, treatment of the refrigerant, oil and other parts MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery.

9 Glossary

DHW = Domestic hot water
Hot water used, in any type of building, for domestic purposes.
LWT = Leaving water temperature
Water temperature at the water outlet of the unit.
Operation manual
20
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10

Inhaltsverzeichnis

Inhaltsverzeichnis
1 Monteureinstellungen: Vom Monteur
auszufüllende Tabellen 21
1.1 Konfigurationsassistent ............................................................. 21
1.2 Menü "Einstellungen" ................................................................ 22
2 Kurzanleitung 22
2.1 Zugriffserlaubnisstufe ................................................................ 22
2.2 Raumheizung/-kühlung ............................................................. 22
2.3 Brauchwasser............................................................................ 24
3 Allgemeine Informationen 25
3.1 Informationen zu diesem Dokument.......................................... 25
3.2 Über das System....................................................................... 25
3.2.1 Komponenten in einem typischen Systemlayout ........ 26
4 Betrieb 26
4.1 Bedieneinheit: Überblick............................................................ 26
4.2 Menüstruktur: Übersicht über die Benutzereinstellungen.......... 28
4.3 Mögliche Bildschirme: Überblick ............................................... 29
4.3.1 Startbildschirm ............................................................ 29
4.3.2 Hauptmenübildschirm ................................................. 30
4.3.3 Sollwert-Bildschirm ..................................................... 30
4.3.4 Detaillierter Bildschirm mit Werten.............................. 31
4.4 Ein-/Ausschalten des Betriebs .................................................. 31
4.4.1 Visuelle Anzeige ......................................................... 31
4.4.2 So schalten Sie es EIN oder AUS............................... 31
4.5 Auslesen von Informationen...................................................... 32
So lesen Sie Informationen aus .................................. 32
Mögliche auslesbare Informationen ............................ 32
4.6 Regelung der Raumheizung/-kühlung....................................... 32
4.6.1 Einstellung des Betriebsmodus................................... 32
4.6.2 So ändern Sie die Soll-Raumtemperatur .................... 32
4.6.3 So ändern Sie die Soll-Vorlauftemperatur .................. 33
4.7 Brauchwasserregelung.............................................................. 33
4.7.1 Warmhaltebetrieb........................................................ 33
4.7.2 Programmbetrieb ........................................................ 33
4.7.3 Programmbetrieb + Warmhaltebetrieb........................ 34
4.7.4 Verwendung des Brauchwasser-
Hochleistungsbetriebs................................................. 34
4.8 Programmbildschirm: Beispiel................................................... 34
4.9 Witterungsgeführte Kurve.......................................................... 36
4.9.1 Was ist eine witterungsgeführte Kurve? ..................... 36
4.9.2 2-Punkte-Kurve........................................................... 36
4.9.3 Steilheit-Korrektur-Kurve............................................. 37
4.9.4 Verwenden der witterungsgeführten Kurven............... 38
5 Tipps zum Energiesparen 39 6 Instandhaltung und Wartung 39
6.1 Übersicht: Instandhaltung und Wartung .................................... 39
7 Fehlerdiagnose und -beseitigung 40
7.1 Zum Anzeigen von Hilfeinformationen im Falle einer
Fehlfunktion............................................................................... 40
7.2 Überprüfen des Fehlfunktionsverlaufs....................................... 40
7.3 Symptom: Ihnen ist in Ihrem Wohnzimmer zu kalt (warm)........ 40
7.4 Symptom: Das Wasser am Wasserhahn ist zu kalt .................. 40
7.5 Symptom: Wärmepumpenausfall .............................................. 40
7.6 Symptom: Das Gerät macht nach der Inbetriebnahme
gurgelnde Geräusche................................................................ 41
1 Monteureinstellungen: Vom
Monteur auszufüllende Tabellen

1.1 Konfigurationsassistent

Einstellung Ausfüllen …
System
Innengerätetyp
(schreibgeschützt) Reserveheizungstyp [9.3.1]
(schreibgeschützt)
Brauchwasser [9.2.1] Notbetrieb [9.5] Anzahl der Zonen [4.4]
Mit Glykol gefülltes System (Überblick bauseitige
Einstellung [E‑0D])
Leistung der Zusatzheizung
[9.4.1] (falls zutreffend)
Reserveheizung
Spannung [9.3.2] Erweiterte-Funktion [9.3.3] Leistung Schritt 1 [9.3.4]
Zusätzliche Leistung Schritt 2 [9.3.5] (falls
zutreffend)
Hauptzone
Typ Wärmeerzeuger [2.7] Steuerung [2.9] Sollwertmodus [2.4] Zeitprogramm [2.1]
Typ witterungsgeführte Kurve [2.E]
Zusatzzone (nur wenn [4.4]=1, Dual-Zone)
Typ Wärmeerzeuger [3.7] Steuerung (schreibgeschützt)
[3.9]
Sollwertmodus [3.4] Zeitprogramm [3.1]
Typ witterungsgeführte Kurve [3.C] (schreibgeschützt)
Speicher (falls zutreffend)
Betriebsart Heizen [5.6] Komfort-Sollwert [5.2] Eco-Sollwert [5.3] Warmhalte-Sollwert [5.4] Sollwertmodus [5.B]
Typ witterungsgeführte Kurve [5.E] (schreibgeschützt)
8 Entsorgung 41 9 Glossar 41
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10

Betriebsanleitung

21

2 Kurzanleitung

Benutzerprofil
B
0000
Benutzer
1234
Erweiterter Endbenutzer
Betrieb
Raum
Raumheizung/-kühlung
Ein
Ein
C.1
Betrieb
Raumheizung/-kühlung
Speicher
Aus
Ein
Ein
Raum
C.2
Raum
1
+
21°C
1
a b
Raum

1.2 Menü "Einstellungen"

Einstellung Eingabe …
Hauptzone
Thermostattyp [2.A]
Zusatzzone (falls zutreffend)
Thermostattyp [3.A]
Information
Händlerinformation [8.3]
2 Kurzanleitung

2.1 Zugriffserlaubnisstufe

Die Menge der Informationen, die Sie in der Menüstruktur auslesen und bearbeiten können, variiert abhängig von Ihrer Zugriffserlaubnisstufe:
Benutzer: Standardmodus
Erweiterter Endbenutzer: Sie können mehr Informationen
auslesen und bearbeiten.
So ändern Sie die Zugriffserlaubnisstufe
1 Gehen Sie zu [B]: Benutzerprofil.

2.2 Raumheizung/-kühlung

So schalten Sie die Raumtemperatursteuerung EIN oder AUS
1 Gehen Sie zu [C.1]: Betrieb > Raum.
2 Setzen Sie den Betrieb auf Ein oder Aus.
So schalten Sie den Raumheizungs-/-kühlbetrieb EIN oder AUS
HINWEIS Frostschutz Raum. Auch wenn Sie den Raumheiz-/-
kühlbetrieb ausschalten ([C.2]: Betrieb > Raumheizung/­kühlung), bleibt der Frostschutz Raum aktiv, wenn er
aktiviert wurde.
HINWEIS Wasserrohr-Frostschutz. Auch wenn Sie den
Raumheiz-/-kühlbetrieb ausschalten ([C.2]: Betrieb > Raumheizung/-kühlung), bleibt der Wasserrohr-
Frostschutz aktiv, wenn er aktiviert wurde.
1 Gehen Sie zu [C.2]: Betrieb > Raumheizung/-
kühlung.
2 Geben Sie den gültigen PIN-Code für die
Zugriffserlaubnisstufe ein. ▪ Blättern Sie durch die Liste der Ziffern und ändern
Sie die ausgewählte Ziffer. ▪ Bewegen Sie den Cursor von links nach rechts. ▪ Bestätigen Sie den PIN-Code und fahren Sie fort.
Benutzer-Pincode Der Benutzer-Pincode ist 0000.
Pincode Erweiterter Endbenutzer
Der Erweiterter Endbenutzer-Pincode ist 1234. Nun sind zusätzliche Menüelemente für den Benutzer sichtbar.
2 Setzen Sie den Betrieb auf Ein oder Aus.
So ändern Sie die Soll-Raumtemperatur
Während der Raumtemperatursteuerung können Sie den Raumtemperatur-Sollwert-Bildschirm verwenden, um die Soll­Raumtemperatur abzulesen und anzupassen.
1 Gehen Sie zu [1]: Raum.
2 Ändern Sie die Soll-Raumtemperatur.
a Ist-Raumtemperatur b Soll-Raumtemperatur
Betriebsanleitung
22
So ändern Sie die Soll-Vorlauftemperatur
Sie können den Vorlauftemperatur-Sollwert-Bildschirm verwenden, um die Soll-Vorlauftemperatur abzulesen und anzupassen.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
2 Kurzanleitung
Hauptzone
2
Zusatzzone
3
+
35°C
2
a b
Hauptzone
+
45°C
3
a b
Zusatzzone
X1 X2
c
d
Y1
Y2
Y3
Y4
a b
Y1
Y2
Y3
Y4
X1 X2
a b
c
d
Y1
Y2
X1 X2
1 Gehen Sie zu [2]: Hauptzone oder [3]: Zusatzzone.
2 Passen Sie die Soll-Vorlauftemperatur an.
Steilheit-Korrektur-Kurve
Steilheit. Wenn die Steilheit
geändert wird, ist die neue bevorzugte Temperatur an X1 ungleich höher als die bevorzugte Temperatur an X2.
X1, X2 Umgebungstemperatur außen Y1~Y4 Soll-Vorlauftemperatur
a Witterungsgeführte Kurve vor den Änderungen b Witterungsgeführte Kurve nach den Änderungen c Steilheit d Korrektur
Mögliche Aktionen in diesem Bildschirm
Wählen Sie die Steilheit oder die Korrektur. Erhöhen oder verringern Sie die Steilheit/Korrektur. Wenn die Steilheit ausgewählt ist: Legen Sie die
Steilheit fest und wechseln Sie zur Korrektur. Wenn die Korrektur ausgewählt ist: Legen Sie die
Korrektur fest. Überprüfen Sie die Änderungen und kehren Sie zum
Untermenü zurück.
Korrektur. Wenn die Korrektur geändert wird, sind die neue bevorzugte Temperatur an X1 und die bevorzugte Temperatur an X2 gleichermaßen höher.
a Aktuelle Vorlauftemperatur b Soll-Vorlauftemperatur
So ändern Sie die witterungsgeführte Kurve für die Raumheizungs-/Kühlzonen
1 Gehen Sie zur betreffenden Zone:
Zone Gehen Sie zu …
Hauptzone – Heizung [2.5] Hauptzone >
Witterungsgeführte Heizkurve
Hauptzone – Kühlen [2.6] Hauptzone >
Witterungsgeführte Kühlkurve
Zusatzzone – Heizung [3.5] Zusatzzone >
Witterungsgeführte Heizkurve
Zusatzzone – Kühlen [3.6] Zusatzzone >
Witterungsgeführte Kühlkurve
2 Ändern Sie die witterungsgeführte Kurve.
Es gibt 2 Arten von witterungsgeführten Kurven: Steilheit- Korrektur-Kurve (Standard) und 2-Punkte-Kurve. Bei Bedarf können Sie den Typ unter [2.E] Hauptzone > Typ witterungsgeführte Kurve ändern. Die Methode zum Anpassen der Kurve hängt vom Typ ab.
2-Punkte-Kurve
X1, X2 Umgebungstemperatur außen Y1, Y2 Soll-Vorlauftemperatur
Mögliche Aktionen in diesem Bildschirm
Durchlaufen Sie die Temperaturen. Ändern Sie die Temperatur. Fahren Sie mit der nächsten Temperatur fort. Bestätigen Sie die Änderungen und fahren Sie fort.
Weitere Informationen
Nähere Informationen finden Sie auch unter: ▪ "4.4Ein-/Ausschalten des Betriebs"[431]"4.6Regelung der Raumheizung/-kühlung"[432]"4.8Programmbildschirm: Beispiel"[434]"4.9Witterungsgeführte Kurve"[436] ▪ Referenzhandbuch für den Benutzer
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Betriebsanleitung
23
2 Kurzanleitung
Betrieb
Speicher
Aus
Ein
Raumheizung/-kühlung
C.3
Speicher
5
+
50°C
5
a b
Speicher

2.3 Brauchwasser

So schalten Sie den Speicherheizungsbetrieb EIN oder AUS
HINWEIS Desinfektionsmodus. Auch wenn Sie den Heizbetrieb
ausschalten ([C.3]: Betrieb > Speicher), bleibt der Desinfektionsmodus. aktiv. Wenn Sie aber die Desinfektion während der Ausführung ausschalten, kommt es zu einem AH-Fehler.
1 Gehen Sie zu [C.3]: Betrieb > Speicher.
2 Setzen Sie den Betrieb auf Ein oder Aus.
So ändern Sie den Speichertemperatur-Sollwert
Im Modus Nur Warmhalten können Sie den Speichertemperatur­Sollwert-Bildschirm verwenden, um die Brauchwassertemperatur abzulesen und anzupassen.
1 Gehen Sie zu [5]: Speicher.
2 Passen Sie die Brauchwassertemperatur an.
a Ist-Brauchwassertemperatur b Soll-Brauchwassertemperatur
In anderen Modi können Sie den Sollwert-Bildschirm nur anzeigen, ihn aber nicht ändern. Stattdessen können Sie die Einstellungen für
Komfort-Sollwert [5.2], Eco-Sollwert [5.3] und Warmhalte­Sollwert [5.4] anpassen.
Weitere Informationen
Nähere Informationen finden Sie auch unter: ▪ "4.4Ein-/Ausschalten des Betriebs"[431]"4.7Brauchwasserregelung"[433]"4.8Programmbildschirm: Beispiel"[434] ▪ Referenzhandbuch für den Benutzer
Betriebsanleitung
24
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10

3 Allgemeine Informationen

4
Raumheizung/-kühlung
Betriebsbereich
4.3
3 Allgemeine Informationen

3.1 Informationen zu diesem Dokument

Vielen Dank, dass Sie sich für den Kauf dieses Produkts entschieden haben. Zu beachten:
▪ Lesen Sie die Dokumentation aufmerksam durch, bevor Sie die
Benutzerschnittstelle verwenden, um die bestmögliche Leistung zu gewährleisten.
▪ Bitten Sie den Monteur, Sie über die Einstellungen zu informieren,
die er für die Konfiguration Ihres Systems verwendet hat. Überprüfen Sie, ob er die Tabellen mit den Monteureinstellungen ausgefüllt hat. Falls nicht, bitten Sie ihn, diese Tabellen auszufüllen.
▪ Bewahren Sie die Dokumentation zu Referenzzwecken sorgfältig
auf.
Zielgruppe
Endbenutzer
Dokumentationssatz
Dieses Dokument ist Teil eines Dokumentationssatzes. Der vollständige Satz besteht aus:
Allgemeine Sicherheitsvorkehrungen:
▪ Sicherheitsanweisungen, die Sie vor der Installation lesen
müssen
▪ Format: Papier (im Lieferumfang des Innengeräts enthalten)
Betriebsanleitung:
▪ Kurzanleitung mit Hinweisen zur grundlegenden Nutzung ▪ Format: Papier (im Lieferumfang des Innengeräts enthalten)
Referenzhandbuch für den Benutzer:
▪ Detaillierte schrittweise Anleitungen und
Hintergrundinformationen für die grundlegende und erweiterte Nutzung
▪ Format: Digitale Dateien unter http://www.daikineurope.com/
support-and-manuals/product-information/
Installationsanleitung – Außengerät:
▪ Installationsanleitung ▪ Format: Papier (im Lieferumfang des Außengeräts enthalten)
Installationsanleitung – Innengerät:
▪ Installationsanleitung ▪ Format: Papier (im Lieferumfang des Innengeräts enthalten)
Referenzhandbuch für den Monteur:
▪ Vorbereitung der Installation, bewährte Verfahren,
Referenzdaten…
▪ Format: Digitale Dateien unter http://www.daikineurope.com/
support-and-manuals/product-information/
Ergänzungshandbuch für optionale Ausstattung:
▪ Weitere Informationen bezüglich der Installation von optionalen
Ausstattungen
▪ Format: Papier (im Lieferumfang des Innengeräts enthalten) +
Digitale Dateien unter http://www.daikineurope.com/support-
and-manuals/product-information/
Neueste Ausgaben der mitgelieferten Dokumentation gibt es gegebenenfalls auf der regionalen Daikin-Webseite oder bei Ihrem Installateur.
Die Original-Dokumentation ist auf Englisch verfasst. Bei der Dokumentation in anderen Sprachen handelt es sich um Übersetzungen des Originals.
Daikin Residential Controller-App
Wenn dies vom Monteur eingerichtet wurde, können Sie über die App Daikin Residential Controller den Status Ihres Systems steuern und überwachen. Weitere Informationen finden Sie unter:
http://www.onlinecontroller.daikineurope.com/
Brotkrumen
Brotkrumen (Beispiel: [4.3]) helfen Ihnen dabei zu ermitteln, wo Sie sich gerade in der Menüstruktur der Bedieneinheit befinden.
1 So aktivieren Sie die Brotkrumen: Drücken Sie im
Startbildschirm oder Hauptmenübildschirm die Hilfe­Taste. Die Brotkrumen werden oben links im Bildschirm angezeigt.
2 So deaktivieren Sie die Brotkrumen: Drücken Sie
erneut die Hilfe-Taste.
In diesem Dokument sind diese Brotkrumen ebenfalls erwähnt.
Beispiel:
1 Gehen Sie zu [4.3]: Raumheizung/-kühlung >
Betriebsbereich.
Das bedeutet:
1 Drehen Sie ausgehend vom Startbildschirm den
linken Regler und rufen Sie Raumheizung/-kühlung auf.
2 Drücken Sie den linken Regler, um das Untermenü
aufzurufen.
3 Drehen Sie den linken Regler, um
Betriebsbereich aufzurufen.
4 Drücken Sie den linken Regler, um das Untermenü
aufzurufen.

3.2 Über das System

Abhängig vom Systemlayout kann das System: ▪ einen Raum erwärmen ▪ einen Raum abkühlen (wenn eine Wärmepumpe zum Heizen/
Kühlen installiert ist)
▪ Brauchwasser erzeugen (wenn ein Brauchwasserspeicher
installiert ist)
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Betriebsanleitung
25

4 Betrieb

g
A
db
a
f
e
c
BC
b
c
a
a
b c
INFORMATION
Der Kühlbetrieb ist nur im folgenden Fall zutreffend:
▪ Modelle für Heiz- und Kühlbetrieb ▪ Nur-Heizen-Modelle + Umwandlungssatz
3.2.1 Komponenten in einem typischen Systemlayout
A Hauptzone. Beispiel: Wohnzimmer. B Zusätzliche Zone. Beispiel: Schlafzimmer. C Nutzfläche. Beispiel: Garage.
a Wärmepumpe des Außengeräts
b Wärmepumpe des Innengeräts
c Brauchwasserspeicher (BW-Speicher)
d Bedieneinheit am Innengerät
e Spezielle Komfort-Benutzerschnittstelle (BRC1HHDA wird als
Raumthermostat verwendet)
f Unterbodenheizung
g Radiatoren, Wärmepumpen-KonvektorenoderVentilator-
Konvektoren
INFORMATION
Innengerät und Brauchwasserspeicher (falls installiert) können abhängig vom Innengerätetyp getrennt oder integriert werden.
4 Betrieb
INFORMATION
Der Kühlbetrieb ist nur im folgenden Fall zutreffend:
▪ Modelle für Heiz- und Kühlbetrieb ▪ Nur-Heizen-Modelle + Umwandlungssatz

4.1 Bedieneinheit: Überblick

Die Bedieneinheit hat die folgenden Komponenten:
a Statusanzeige
b LCD-Bildschirm
c Regler und Tasten
a Statusanzeige
b LCD-Bildschirm
c Regler und Tasten
Statusanzeige
Die LEDs der Statusanzeige leuchten oder blinken und zeigen so den Betriebsmodus des Geräts.
LED Modus Beschreibung
Blinkt blau Standby Das Gerät ist nicht in Betrieb. Leuchtet blau Betrieb Das Gerät ist in Betrieb. Blinkt rot Fehler Es ist ein Fehler aufgetreten.
Weitere Einzelheiten dazu siehe
"7.1Zum Anzeigen von Hilfeinformationen im Falle einer Fehlfunktion"[440].
Betriebsanleitung
26
LCD-Bildschirm
Der LCD-Bildschirm verfügt über eine Ruhemodusfunktion. Nach 15Minuten ohne Interaktion mit dem Raumbedienmodul verdunkelt sich der Bildschirm. Durch das Betätigen einer Taste oder das Drehen eines Reglers wird der Bildschirm reaktiviert.
Regler und Tasten
Sie verwenden die Regler und Tasten: ▪ Zur Navigation durch die Bildschirme, Menüs und Einstellungen
des LCD-Bildschirms
▪ Zum Festlegen von Werten
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
a b c d e
Posten Beschreibung
a Linker
Regler
b Zurück-
Taste
c Startbildsch
irm-Taste
d Hilfe-Taste : Drücken, um einen Hilfetext in Bezug auf die
e Rechter
Regler
Das LCD zeigt einen Bogen auf der linken Seite des Displays, wenn Sie den linken Regler verwenden können.
: Drehen und dann den linken Regler
drücken. Durch die Menüstruktur navigieren.
: Linken Regler drehen. Menüelement
auswählen.
: Linken Regler drücken. Auswahl
bestätigen oder ein Untermenü aufrufen.
: Drücken, um 1 Schritt in der Menüstruktur
zurückzugehen.
: Drücken, um zum Startbildschirm
zurückzukehren.
aktuelle Seite anzuzeigen (wenn verfügbar). Das LCD zeigt einen Bogen auf der rechten Seite
des Displays, wenn Sie den rechten Regler verwenden können.
: Drehen und dann den rechten Regler
drücken. Einen Wert oder eine Einstellung ändern, die auf der rechten Seite des Bildschirms angezeigt werden.
: Rechten Regler drehen. Durch die
möglichen Werte und Einstellungen navigieren.
: Rechten Regler drücken. Auswahl
bestätigen und zum nächsten Menüelement wechseln.
4 Betrieb
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Betriebsanleitung
27
4 Betrieb
[1]
Raum
Abweichung Raumfühler
Sollwertgrenzen
Frostschutz
Kühlprogramm
Heizprogramm
Zeitprogramm
[2]
Hauptzone Zeitprogramm
Heizprogramm
Sollwertmodus
Kühlprogramm
Witterungsgeführte Heizkurve Witterungsgeführte Kühlkurve Typ witterungsgeführte Kurve
[3]
Zusatzzone Zeitprogramm
Heizprogramm
Sollwertmodus
Kühlprogramm
Witterungsgeführte Heizkurve Witterungsgeführte Kühlkurve Typ witterungsgeführte Kurve
[4]
Raumheizung/-kühlung
Betriebsart Betriebsart Programm
[7]
Benutzereinstellungen Sprache
Zeit/Datum Ferien Leise Strompreis Gaspreis
[8]
Information Energiedaten
Fehlerübersicht Händlerinformation Sensoren Aktoren Betriebsarten Info Verbindungsstatus Betriebsstunden
[B]
Benutzerprofil
[C]
Betrieb
Raum Raumheizung/-kühlung Speicher
[1.4]
Frostschutz
Aktivierung Raumtemperatur-Sollwert
[1.5]
Sollwertgrenzen Heizen Minimum
Heizen Maximum Kühlen Minimum Kühlen Maximum
[7.2]
Zeit/Datum
Stunden Minuten Jahr Monat Tag Sommerzeit Format
[7.3]
Ferien
Aktivierung Von Bis
[7.4]
Leise
Aktivierung Zeitprogramm Stufe
[7.5]
Strompreis
Hoch Mittel Niedrig Zeitprogramm
[8.1]
Energiedaten
Stromzufuhr Erzeugte Wärme
(**)
(**)
[5]
Speicher
Hochleistungsbetrieb Komfort-Sollwert Eco-Sollwert Warmhalte-Sollwert Zeitprogramm Witterungsgeführte Kurve Typ witterungsgeführte Kurve
(*) (*)
(*)
(*)
(*)
(*)
(*)
(*)
[D]
Drahtlos-Gateway
Modus WPS Neu starten Geräteinformationen
(***)

4.2 Menüstruktur: Übersicht über die Benutzereinstellungen

Betriebsanleitung
28
INFORMATION
Abhängig von den gewählten Monteureinstellungen und dem Gerätetyp sind die Einstellungen sichtbar/ ausgeblendet.
Sollwert-Bildschirm
(*) Gilt nur für Modelle für Heiz- und Kühlbetrieb oder Nur-Heizen-Modelle + Umwandlungssatz
(**) Nur für den Monteur zugänglich
(***) Nur zutreffend, wenn der WLAN-Adapter installiert wurde
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10
4 Betrieb
+
a
OR
b
c
c2
c4
c1
c3
6
1.6
bar
26 Feb 2019
22:19
55
21
35
j
e2
l
k1
k2 k3
45
d
e1
g3
g2
h1
g1
f
i2 i3 i4 h2i1
a2a1e3 b c
55
6
21
35

4.3 Mögliche Bildschirme: Überblick

Dies sind die gängigsten Bildschirme:
a Startbildschirm b Hauptmenübildschirm c Bildschirme der unteren Ebene:
c1: Sollwert-Bildschirm c2: Detaillierter Bildschirm mit Werten c3: Detaillierter Bildschirm mit der witterungsgeführten
Kurve
c4: Bildschirm mit Programm
4.3.1 Startbildschirm
Drücken Sie die Taste , um zum Startbildschirm zurückzukehren. Sie sehen einen Überblick der Gerätekonfiguration, den Raum und die Sollwert-Temperaturen. Nur Symbole, die für Ihre Konfiguration gelten, sind auf dem Startbildschirm sichtbar.
Posten Beschreibung
a Brauchwasser
a1 Brauchwasser
a2
Gemessene Speichertemperatur
(a)
b Desinfektion/Leistungsstark
Desinfektionsmodus aktiv
Hochleistungs-Betriebsart aktiv
c Notfall
Wärmepumpen-Ausfall und System läuft im Notbetrieb-Modus oder die Wärmepumpe wird erzwungenermaßen ausgeschaltet.
d Aktuelles Datum und Uhrzeit
e Smart Energy
e1 Smart Energy ist über Solarpanele oder Smart Grid
verfügbar.
e2 Smart Energy wird derzeit für die Raumheizung
verwendet.
e3 Smart Energy wird derzeit für Brauchwasser
verwendet.
f Betriebsmodus
Kühlen
Heizen
g Außen / geräuscharmer Betrieb
g1
Gemessene Außentemperatur
(a)
g2 Geräuscharmer Betrieb aktiv
g3 Außengerät
h Innengerät/Brauchwasserspeicher
h1 Innengerät für Aufstellung auf dem Boden mit
integriertem Speicher
Wandmontiertes Innengerät
Wandmontiertes Innengerät mit separatem Speicher
h2 Wasserdruck
i Hauptzone
i1 Installierter Raumthermostattyp:
Der Gerätebetrieb wird basierend auf der von der speziellen Komfort-Benutzerschnittstelle (BRC1HHDA, verwendet als Raumthermostat) bestimmten Umgebungstemperatur bestimmt.
Der Gerätebetrieb wird durch den externen Raumthermostat (kabelgebunden oder drahtlos) gesteuert.
Kein Raumthermostat installiert oder eingestellt.
Mögliche Aktionen in diesem Bildschirm
Durchlaufen Sie die Liste des Hauptmenüs. Gehen Sie zum Hauptmenübildschirm.
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W Daikin Altherma 3 H HT F+W 4P586455-1C – 2020.10
Aktivieren/deaktivieren Sie Brotkrumen.
i2 Installierter Heizverteilsystem-Typ:
i3
i4
Der Betrieb des Geräts wird abhängig von der Vorlauftemperatur und unabhängig von der aktuellen Raumtemperatur und/oder vom Heizbedarf im Raum geregelt.
Fußbodenheizung
Ventilator-Konvektor
Heizkörper
Gemessene Raumtemperatur
Vorlauftemperatur-Sollwert
(a)
(a)
Betriebsanleitung
29
4 Betrieb
45
a
2
Hauptzone
Zusatzzone
Raum
Fehler
Raumheizung/-kühlung
+
21°C
1
Raum
+
35°C
2
Hauptzone
+
45°C
3
Zusatzzone
+
50°C
5
Speicher
Posten Beschreibung
j Urlaubsmodus
Urlaubsmodus aktiv
k Zusatzzone
k1 Installierter Raumthermostattyp:
Der Gerätebetrieb wird durch den externen Raumthermostat (kabelgebunden oder drahtlos) gesteuert.
Kein Raumthermostat installiert oder eingestellt.
Der Betrieb des Geräts wird abhängig von der Vorlauftemperatur und unabhängig von der aktuellen Raumtemperatur und/oder vom Heizbedarf im Raum geregelt.
k2 Installierter Heizverteilsystem-Typ:
Fußbodenheizung
Ventilator-Konvektor
Heizkörper
k3
l Fehler
(a)
Vorlauftemperatur-Sollwert
Es ist ein Fehler aufgetreten. Weitere Einzelheiten dazu siehe "7.1Zum
Anzeigen von Hilfeinformationen im Falle einer Fehlfunktion"[440].
Wenn der entsprechende Betrieb (z.B. die Raumheizung) nicht aktiv ist, ist der Kreis ausgegraut.
(a)
4.3.2 Hauptmenübildschirm
Beginnen Sie auf dem Startbildschirm und drücken ( ) oder drehen Sie ( ) den linken Regler, um den Hauptmenübildschirm zu öffnen. Über das Hauptmenü können Sie auf die verschiedenen Sollwertbildschirme und Untermenüs zugreifen.
Untermenü Beschreibung
[2]
Hauptzone
[3]
Zusatzzone
[4]
Raumheizung/-
kühlung
[5]
Speicher
[7]
Benutzereinstellun gen
[8]
Information
[9]
Monteureinstellung en
[A]
Inbetriebnahme
[B]
Benutzerprofil
[C]
Betrieb
[D]
Drahtlos-
Gateway
Zeigt das zutreffende Symbol für Ihren Hauptzonen-Emittertyp an.
Legen Sie die Vorlauftemperatur für die Hauptzone fest.
Einschränkung: Wird nur angezeigt, wenn es zwei Vorlauftemperaturzonen gibt. Zeigt das zutreffende Symbol für Ihren Zusatzzonen-Emittertyp an.
Legen Sie die Vorlauftemperatur für die Zusatzzone fest (falls vorhanden).
Zeigt das zutreffende Symbol Ihres Geräts an.
Versetzen Sie das Gerät in den Heizen-Modus oder den Kühlen­Modus. Sie können den Modus bei Nur-Heizen-Modellen nicht ändern.
Legen Sie die Brauchwasserspeicher­Temperatur fest.
Bietet Zugriff auf die Benutzereinstellungen, wie den Urlaubsmodus und den geräuscharmen Betrieb.
Zeigt Daten und Informationen zum Innengerät an.
Einschränkung: Nur für den Monteur. Bietet Zugriff auf die erweiterten
Einstellungen. Einschränkung: Nur für den Monteur.
Führt Tests und die Wartung durch. Ändern Sie das aktive Benutzerprofil.
Schalten Sie die Heizen-/Kühlen­Funktionalität und die Brauchwasserproduktion ein oder aus.
Einschränkung: Wird nur angezeigt, wenn ein WLAN installiert ist.
Enthält Einstellungen, die erforderlich sind, wenn die Daikin Residential Controller-App konfiguriert wird.
Mögliche Aktionen in diesem Bildschirm
Untermenü Beschreibung
[0]
oder Fehler
[1]
Raum
Betriebsanleitung
30
a Ausgewähltes Untermenü
Durchlaufen Sie die Liste. Rufen Sie das Untermenü auf. Aktivieren/deaktivieren Sie Brotkrumen.
Einschränkung: Wird nur angezeigt, wenn es zu einem Fehler kommt.
Weitere Einzelheiten dazu siehe
"7.1Zum Anzeigen von Hilfeinformationen im Falle einer Fehlfunktion"[440].
Einschränkung: Wird nur angezeigt, wenn eine spezielle Komfort­Benutzerschnittstelle (BRC1HHDA, verwendet als Raumthermostat) das Innengerät steuert.
Legen Sie die Raumtemperatur fest.
4.3.3 Sollwert-Bildschirm
Der Sollwert-Bildschirm wird für Bildschirme angezeigt, die Systemkomponenten beschreiben, die einen Sollwert benötigen.
Beispiele
[1] Raumtemperatur-Bildschirm
[3] Zusatzzone-Bildschirm
ETVH/X16S18+23DA6V+9W(G) + ETBH/X16DF6V+9W
[2] Hauptzone-Bildschirm
[5] Speichertemperatur­Bildschirm
Daikin Altherma 3 H HT F+W
4P586455-1C – 2020.10