Daikin FTKE25BVM, FLKS25BVMB, FTKE25BVMA, FTKS20CVMB, FTKE35BVM Service Manual

...
SiE12-411
Service
Manual
C-Series
[Applied Models]
!Inverter Multi : Cooling Only !Inverter Multi : Heat Pump
SiE12-411
Table of Contents i
SUPER MULTI NX
C-Series
!Cooling Only Indoor Unit
FTKE25BVM FTKE25BVMA FTKS20CVMB(9) FLKS25BVMB FTKE35BVM FTKE35BVMA FTKS25CVMB(9)(8) FLKS35BVMB FTKD50BVM FTKD50BVMA FTKS35CVMB(9)(8) FLKS50BVMB FTKD60BVM FTKD60BVMA FTKS50BVMB FLKS60BVMB FTKD71BVM FTKD71BVMA FTKS60BVMB FVKS25BVMB CDKD25CVM CDKD25CVMA FTKS71BVMB FVKS35BVMB CDKD35CVM CDKD35CVMA CDKS25CVMB FVKS50BVMB CDKD50CVM CDKD50CVMA CDKS35CVMB CDKD60CVM CDKD60CVMA CDKS50CVMB
FLK25AVMA CDKS60CVMB FLK35AVMA FLK50AVMA FLK60AVMA
Outdoor Unit
2MKD58BVM 3MKD75BVMA 3MKS50BVMB(8) 3MKD58BVM 4MKD90BVMA 4MKS58BVMB(8) 3MKD75BVM 4MKS75BVMB 4MKD75BVM 4MKS90BVMB 4MKD90BVM
!Heat Pump Indoor Unit
FTXE25BVMA FTXS20CVMB(9) FLXS25BVMB FTXS25BVMA FTXE35BVMA FTXS25CVMB(9)(8) FLXS35BVMB FTXS35BVMA FTXD50BVMA FTXS35CVMB(9)(8) FLXS50BVMB FTXS50BVMA FTXD60BVMA FTXS50BVMB FLXS60BVMB FTXS60BVMA FTXD71BVMA FTXS60BVMB FVXS25BVMB FTXS71BVMA CDXD25CVMA FTXS71BVMB FVXS35BVMB CDXS25CVMA CDXD35CVMA ATXS20CVMB(9) FVXS50BVMB CDXS35CVMA CDXD50CVMA ATXS25CVMB(9) CDXS50CVMA CDXD60CVMA ATXS35CVMB(9) CDXS60CVMA FLX25AVMA ATXS50CVMB FLXS25BVMA FLX35AVMA CDXS25CVMB FLXS35BVMA FLX50AVMA CDXS35CVMB FLXS50BVMA FLX60AVMA CDXS50CVMB FLXS60BVMA
CDXS60CVMB FVXS35BVMA
FVXS50BVMA
Outdoor Unit
3MXD68BVMA 3MXS52BVMB(8) 3AMXS52BVMB 4MXS80CVMA 4MXD80BVMA 4MXS68BVMB9
4MXS80BVMB9
SiE12-411
ii Table of Contents
1. Introduction ...........................................................................................vii
1.1 Safety Cautions......................................................................................vii
Part 1 List of Functions ................................................................ 1
1. List of Functions......................................................................................2
1.1 Cooling Only Models ................................................................................2
1.2 Heat Pump Models...................................................................................8
Part 2 Specifications .................................................................. 17
1. Specifications........................................................................................18
1.1 Indoor Units - Cooling Only ....................................................................18
1.2 Outdoor Units - Cooling Only .................................................................30
1.3 Indoor Units - Heat Pump.......................................................................36
1.4 Outdoor Units - Heat Pump....................................................................51
Part 3 Printed Circuit Board Connector Wiring Diagram ........... 57
1. Printed Circuit Board Connector Wiring Diagram..................................58
1.1 Wall Mounted Type 20 / 25 / 35 Class ...................................................58
1.2 Wall Mounted Type 50 / 60 / 71 Class ...................................................61
1.3 Duct Connected Type.............................................................................63
1.4 Floor / Ceiling Suspended Dual Type.....................................................64
1.5 Floor Standing Type...............................................................................66
1.6 Outdoor Units .........................................................................................68
Part 4 Function and Control........................................................ 69
1. Main Functions......................................................................................70
1.1 Frequency Principle................................................................................70
1.2 Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing ..........72
1.3 Fan Speed Control for Indoor Units........................................................73
1.4 Programme Dry Function .......................................................................74
1.5 Automatic Operation............................................. .......... ........... .......... ...75
1.6 Night Set Mode.......................................................................................76
1.7 Intelligent Eye.........................................................................................77
1.8 Home Leave Operation ..........................................................................79
1.9 Inverter Powerful Operation ...................................................................80
1.10 Other Functions......................................................................................81
2. Function of Main Structural Parts..........................................................83
2.1 Main Structural Parts..............................................................................83
2.2 Function of Thermistor ...........................................................................84
3. Control Specification.............................................................................88
3.1 Mode Hierarchy......................................................................................88
3.2 Frequency Control..................................................................................89
3.3 Controls at Mode Changing / Start-up....................................................91
3.4 Discharge Pipe Control ..........................................................................92
3.5 Input Current Control..............................................................................92
3.6 Freeze-up Protection Control .................................................................93
3.7 Heating Peak-cut Control .......................................................................93
3.8 Fan Control.............................................................................................94
3.9 Moisture Protection Function 2...............................................................94
SiE12-411
Table of Contents iii
3.10 Defrost Control.......................................................................................95
3.11 Low Hz High Pressure Limit...................................................................95
3.12 Electronic Expansion Valve Control.......................................................96
3.13 Malfunctions.........................................................................................101
3.14 Forced Operation Mode .......................................................................102
3.15 Wiring-Error Check...............................................................................103
3.16 Additional Function...............................................................................105
Part 5 System Configuration.....................................................107
1. System Configuration..........................................................................108
1.1 Operation Instructions ..........................................................................108
2. Instruction............................................................................................109
2.1 Contents and Reference Page.............................................................109
2.2 Safety Precautions ...............................................................................110
2.3 Names of Parts.....................................................................................112
2.4 Preparation before Operation...............................................................124
2.5 AUTO · DRY · COOL · HEAT · FAN Operation....................................127
2.6 Adjusting the Air Flow Direction ...........................................................129
2.7 POWERFUL Operation ........................................................................135
2.8 OUTDOOR UNIT SILENT Operation ...................................................136
2.9 HOME LEAVE Operation .....................................................................137
2.10 INTELLIGENT EYE Operation.............................................................139
2.11 TIMER Operation .................................................................................143
2.12 Note for Multi System...........................................................................145
2.13 Care and Cleaning ...............................................................................147
2.14 Troubleshooting....................................................................................157
Part 6 Service Diagnosis...........................................................161
1. Caution for Diagnosis..........................................................................162
1.1 Troubleshooting with the Operation Lamp ...........................................162
2. Problem Symptoms and Measures.....................................................164
3. Service Check Function......................................................................165
4. Code Indication on the Remote Controller..........................................166
4.1 Error Codes and Description of Fault...................................................166
5. Troubleshooting ..................................................................................167
5.1 Indoor Units..........................................................................................167
5.2 Outdoor Units .......................................................................................168
5.3 Indoor Unit PCB Abnormality ...............................................................169
5.4 Freeze-up Protection Control or High Pressure Control.......................170
5.5 Fan Motor or Related Abnormality .......................................................172
5.6 Thermistor or Related Abnormality (Indoor Unit)..................................175
5.7 Shutter Drive Motor / Shutter Limit Switch Abnormality .......................176
5.8 Signal Transmission Error (between Indoor and Outdoor Units)..........177
5.9 Unspecified Voltage (between Indoor and Outdoor Units)...................178
5.10 Freeze-up Protection Control...............................................................179
5.11 OL Activation (Compressor Overload) .................................................181
5.12 Compressor Lock.................................................................................182
5.13 DC Fan Lock ........................................................................................183
5.14 Input Over Current Detection ...............................................................184
5.15 Four Way Valve Abnormality................................................................186
SiE12-411
iv Table of Contents
5.16 Discharge Pipe Temperature Control...................................................188
5.17 Position Sensor Abnormality................................................................189
5.18 CT or Related Abnormality...................................................................190
5.19 Thermistor or Related Abnormality (Outdoor Unit)...............................192
5.20 Electrical Box Temperature Rise..........................................................194
5.21 Radiation Fin Temperature Rise ..........................................................196
5.22 Output Over Current Detection.............................................................198
5.23 Insufficient Gas.....................................................................................200
5.24 Low-voltage Detection..........................................................................202
5.25 Anti-icing Function in Other Rooms / Unspecified Voltage
(between Indoor and Outdoor Units)....................................................203
6. Check..................................................................................................204
6.1 How to Check.......................................................................................204
Part 7 Removal Procedure ........................................................ 215
1. Outdoor Unit (80 / 90 Class) ...............................................................216
1.1 Removal of Outer Panels .....................................................................216
1.2 Removal of Propeller Fans...................................................................219
1.3 Removal of Electrical Box ....................................................................220
1.4 Removal of PCB...................................................................................227
1.5 Removal of Fan Motor..........................................................................230
1.6 Removal of Electronic Expansion Valve and Thermistor .....................232
1.7 Removal of Sound Insulation and Reactor...........................................233
1.8 Removal of Shunt.................................................................................235
1.9 Removal of Solenoid Valve and Four Way Valve.................................236
1.10 Removal of Compressor.......................................................................238
2. Outdoor Unit (50 / 52 / 58 / 68 / 75 Class) ..........................................240
2.1 Removal of Outer Panels .....................................................................240
2.2 Removal of Electrical BOX...................................................................241
2.3 Removal of PCB...................................................................................245
2.4 Removal of Fan Motor..........................................................................248
2.5 Removal of Sound Insulation ...............................................................249
2.6 Removal of Four Way Valve Coil, Solenoid Valve Coil,
Electronic Expansion Valve Coil and Thermistor .................................250
2.7 Removal of Four Way Valve, Solenoid Valve and Shunt .....................252
2.8 Removal of Solenoid Valve and Shunt.................................................253
2.9 Removal of Compressor.......................................................................254
Part 8 Others ............................................................................. 255
1. Others .................................................................................................256
1.1 Test Run from the Remote Controller ..................................................256
1.2 Jumper Settings ...................................................................................257
Part 9 Appendix.........................................................................259
1. Piping Diagrams..................................................................................260
1.1 Indoor Units..........................................................................................260
1.2 Outdoor Units .......................................................................................266
2. Wiring Diagrams..................................................................................273
2.1 Indoor Units..........................................................................................273
2.2 Outdoor Units .......................................................................................276
SiE12-411
Table of Contents v
Index .............................................................................................i
Drawings & Flow Charts ................................................................ v
SiE12-411
vi Table of Contents
SiE12-411 Introduction
vii
1. Introduction
1.1 Safety Cautions
Cautions and Warnings
" Be sure to read the following safety cautions before conducting repair work. " The caution items are classified into “ Warning” and “ Caution”. The “ Warning
items are especially important since they can lead to death or serious injury if they are not followed closely. The “ Caution” items can also lead to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety caution items described below.
" About the pictograms
This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates a prohibited action.
The prohibited item or action is shown inside or near the symbol.
This symbol indicates an action that must be taken, or an instruction. The instruction is shown inside or near the symbol. " After the repair work is complete, be sure to conduct a test operation to ensure that the
equipment operates normally, and explain the cautions for operating the product to the customer.
1.1.1 Caution in Repair
Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for a repair. Working on the equipment that is connected to a power supply can cause an electrical shook. If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not touch any electrically charged sections of the equipment.
If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas. The refrigerant gas can cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at the welded section, release the refrigerant gas completely at a well-ventilated place first. If there is a gas remaining inside the compressor, the refrig e ran t g as or refrigerating machine oil discharges when the pipe is disconnected, and it can cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate toxic gases when it contacts flames.
The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit. Be sure to discharge the capacitor completely before conducting repair work. A charged capacitor can cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug. Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or fire.
Introduction SiE12-411
viii
1.1.2 Cautions Regarding Products after Repair
Caution
Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock.
Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical shocks.
Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The internal fan rotates at a high speed, and cause injury.
Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor.
Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repair work. Working on the unit when the refrigerating cycle section is hot can cause burns.
Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen deficiency.
Warning
Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can cause an electrical shock, excessive heat generation or fire.
When relocating the equipment, make sure that the new installation site has sufficient strength to withstand the weight of the equipment. If the installation site does not have sufficient strength and if the installation work is not conducted securely, the equipment can fall and cause injury.
Be sure to install the product correctly by using the provided standard installation frame. Incorrect use of the installation frame and improper install ation can cause the equipment to fall, resulting in injury.
For integral units only
Be sure to install the product securely in the installation frame mounted on a window frame. If the unit is not securely mounted, it can fall and cause injury.
For integral units only
SiE12-411 Introduction
ix
1.1.3 Inspection after Repair
Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire.
Be sure to use the specified cable to connect between the indoor and outdoor units. Make the connections securely and route the cable properly so that there is no force pulling the cable at the connection terminals. Improper connections can cause excessive heat generation or fire.
When connecting the cable between the indoor and outdoor units, make sure that the terminal cover does not lift off or dismount because of the cable. If the cover is not mounted properly, the terminal connection section can cause an electrical shock, excessive heat generation or fire.
Do not damage or modify the power cable. Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the power cable, and heating or pulling the power cable can damage the cable.
Do not mix air or gas other than the specified refrigerant (R410A / R22) in the refrigerant system. If air enters the refrigerating system, an excessively high pressure results, causing equipment damage and injury.
If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After charging refrigerant, make sure that there is no refrigerant leak. If the leak cannot be located and the repair work mu st be stopped, be sure to perform pump-down and close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas itself is harmless, but it can generate toxic gases when it contacts flames, such as fan and other heaters, stoves and ranges.
When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent children from swallowing it. If a child swallows the coin battery, see a doctor immediately.
Warning
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks. If a combustible gas leaks and remains around the unit, it can cause a fire.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not installed properly, water can enter the room and wet the furniture and floor.
For integral units only
Warning
Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet all the way. If the plug has dust or loose connection, it can cause an electrical shock or fire.
If the power cable and lead wires have scratches or deteriorated, be sure to replace them. Damaged cable and wires can cause an electrical shock, excessive heat generation or fire.
Introduction SiE12-411
x
1.1.4 Using Icons
Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in the table below:
1.1.5 Using Icons List
Do not use a joined power cable or extension cable, or share the same power outlet with other electrical appliances, since it can cause an electrical shock, excessive heat generation or fire.
Warning
Caution
Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections can cause excessive heat generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can cause the unit to fall, resulting in injury.
Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can cause an electrical shock.
Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 Mohm or higher. Faulty insulation can cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair. Faulty drainage can cause the water to enter the room and wet the furniture and floor.
Icon Type of
Information
Description
Note:
Note A “note” provides information that is not indispensable, but may
nevertheless be valuable to the reader, such as tips and tricks.
Caution
Caution A “caution” is used when there is danger that the reader, through
incorrect manipulation, may damage equipment, loose data, get an unexpected result or has to restart (part of) a procedure.
Warning
Warning A “warning” is used when there is danger of personal injury.
Reference A “reference” guides the reader to other places in this binder or
in this manual, where he/she will find additional information on a specific topic.
SiE12-411
List of Functions 1
Part 1
List of Functions
1. List of Functions......................................................................................2
1.1 Cooling Only Models ................................................................................2
1.2 Heat Pump Models...................................................................................8
List of Functions SiE12-411
2 List of Functions
1. List of Functions
1.1 Cooling Only Models
1.1.1 R22 Series
Category Functions
FTKE25/35BVM
FTKD50-71BVM
CDKD25-60CVM
Category Functions
FTKE25/35BVM
FTKD50-71BVM
CDKD25-60CVM
Basic Function
Inverter (with Inverter Power Control)
###
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
# ——
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter # —— Operation Limit for Heating (°CWB)
———
Air Purifying Filter with Photocatalytic Deodorizing Function
#
PAM Control — — — Longlife Filter — — —
Compressor Oval Scroll Compressor — — — Ultra-Longlife Filter (Option) — — —
Swing Compressor — — — Mould Proof Air Filter ##— Rotary Compressor — — — Wipe-clean Flat Panel ##— Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps ##— Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — — Timer 24-Hour On/Off Timer ### Wide-Angle Louvers # Night Set Mode ### Vertical Auto-Swing (Up and Down) ##— Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ###
Horizontal Auto-Swing (Right and Left)
#
Self-Diagnosis (Digital, LED) Display #
H#H#H
3-D Airflow # Wiring-Error Check — — — 3-Step Airflow (H/P Only)
———
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Comfort Control
Auto Fan Speed
###
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ### Flexible Voltage Correspondence ### Night Quiet Mode (Automatic) — — — High Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
———
Chargeless
———
Intelligent Eye ##— Power-Selection — — — Quick Warming Function
———
Remote Control
5-Rooms Centralized Controller (Option)
###
Hot-Start Function
———
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
###
Automatic Defrosting
———
Remote Control Adaptor (Normal Open Contact)(Option)
###
Operation Automatic Operation — — — Dlll-NET Compatible (Adaptor)(Option) ###
Programme Dry Function ###Remote
Controller
Wireless ###
Fan Only ### Wired — — —
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation ### Priority-Room Setting — — — Cooling / Heating Mode Lock — — — Home Leave Operation ### Indoor Unit On/Off Switch ### Signal Reception Indicator ### Temperature Display — — — Another Room Operation — — —
Note: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 3
Category Functions
FLK25-60AVMA
2MKD58BVM
3MKD58·75BVM
4MKD75·90BVM
Category Functions
FLK25-60AVMA
2MKD58BVM
3MKD58·75BVM
4MKD75·90BVM
Basic Function
Inverter (with Inverter Power Control)
##
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
#
Operation Limit for Cooling (°CDB)
—10~
46
Photocatalytic Deodorizing Filter
#
Operation Limit for Heating (°CWB)
——
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control # Longlife Filter
Compressor Oval Scroll Compressor Ultra-Longlife Filter (Option)
Swing Compressor # Mould Proof Air Filter # Rotary Compressor Wipe-clean Flat Panel — Reluctance DC Motor # Washable Grille
Comfortable Airflow
Power-Airflow Flap Filter Cleaning Indicator — Power-Airflow Dual Flaps Good-Sleep Cooling Operation — Power-Airflow Diffuser Timer 24-Hour On/Off Timer # Wide-Angle Louvers Night Set Mode # Vertical Auto-Swing (Up and Down) # Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) #
Horizontal Auto-Swing (Right and Left) Self-Diagnosis (Digital, LED) Display #
H #
3-D Airflow Wiring-Error Check # 3-Step Airflow (H/P Only)
——
Anticorrosion Treatment of Outdoor Heat Exchanger
#
Comfort Control
Auto Fan Speed
#
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
#
Indoor Unit Silent Operation # Flexible Voltage Correspondence ## Night Quiet Mode (Automatic) # High Ceiling Application — Outdoor Unit Silent Operation
(Manual)
#
Chargeless
#
Intelligent Eye Power-Selection — Quick Warming Function
——
Remote Control
5-Rooms Centralized Controller (Option)
#
Hot-Start Function
——
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
#
Automatic Defrosting
——
Remote Control Adaptor (Normal Open Contact)(Option)
#
Operation Automatic Operation Dlll-NET Compatible (Adaptor)(Option) #
Programme Dry Function # Remote
Controller
Wireless #
Fan Only # —Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Inverter Powerful Operation # Priority-Room Setting # Cooling / Heating Mode Lock — Home Leave Operation # Indoor Unit On/Off Switch # Signal Reception Indicator # Temperature Display — Another Room Operation
Note: # : Holding Functions
— : No Functions
H
: Digital Only
List of Functions SiE12-411
4 List of Functions
Category Functions
FTKE25/35BVMA
FTKD50-71BVMA
CDKD25-60CVMA
Category Functions
FTKE25/35BVMA
FTKD50-71BVMA
CDKD25-60CVMA
Basic Function
Inverter (with Inverter Power Control)
###
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
# ——
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter # —— Operation Limit for Heating (°CWB)
———
Air Purifying Filter with Photocatalytic Deodorizing Function
#
PAM Control — — — Longlife Filter — — —
Compressor Oval Scroll Compressor — — — Ultra-Longlife Filter (Option) — — —
Swing Compressor — — — Mould Proof Air Filter ##— Rotary Compressor — — — Wipe-clean Flat Panel ##— Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps ##— Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — — Timer 24-Hour On/Off Timer ### Wide-Angle Louvers # Night Set Mode ### Vertical Auto-Swing (Up and Down) ##— Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ###
Horizontal Auto-Swing (Right and Left)
#
Self-Diagnosis (Digital, LED) Display #
H#H#H
3-D Airflow # Wiring-Error Check — — — 3-Step Airflow (H/P Only)
———
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Comfort Control
Auto Fan Speed
###
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ### Flexible Voltage Correspondence ### Night Quiet Mode (Automatic) — — — High Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
———
Chargeless
———
Intelligent Eye ##— Power-Selection — — — Quick Warming Function
———
Remote Control
5-Rooms Centralized Controller (Option)
###
Hot-Start Function
———
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
###
Automatic Defrosting
———
Remote Control Adaptor (Normal Open Contact)(Option)
###
Operation Automatic Operation — — — Dlll-NET Compatible (Adaptor)(Option) ###
Programme Dry Function ###Remote
Controller
Wireless ###
Fan Only ### Wired — — —
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation ### Priority-Room Setting — — — Cooling / Heating Mode Lock — — — Home Leave Operation ### Indoor Unit On/Off Switch ### Signal Reception Indicator ### Temperature Display — — — Another Room Operation — — —
Note: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 5
Category Functions
3MKD75BVMA
4MKD90BVMA
Category Functions
3MKD75BVMA
4MKD90BVMA
Basic Function
Inverter (with Inverter Power Control)
#
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
Operation Limit for Cooling (°CDB) 10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
PAM Control # Longlife Filter
Compressor Oval Scroll Compressor Ultra-Longlife Filter (Option)
Swing Compressor # Mould Proof Air Filter — Rotary Compressor Wipe-clean Flat Panel — Reluctance DC Motor # Washable Grille
Comfortable Airflow
Power-Airflow Flap Filter Cleaning Indicator — Power-Airflow Dual Flaps Good-Sleep Cooling Operation — Power-Airflow Diffuser Timer 24-Hour On/Off Timer — Wide-Angle Louvers Night Set Mode — Vertical Auto-Swing (Up and Down) Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) — Horizontal Auto-Swing (Right and Left) Self-Diagnosis (Digital, LED) Display # 3-D Airflow Wiring-Error Check # 3-Step Airflow (H/P Only)
Anticorrosion Treatment of Outdoor Heat
Exchanger
#
Comfort Control
Auto Fan Speed Flexibility Multi-Split / Split Type Compatible Indoor Unit — Indoor Unit Silent Operation Flexible Voltage Correspondence # Night Quiet Mode (Automatic) # High Ceiling Application — Outdoor Unit Silent Operation (Manual) # Chargeless # Intelligent Eye Power-Selection — Quick Warming Function Remote
Control
5-Rooms Centralized Controller (Option) — Hot-Start Function
Remote Control Adaptor
(Normal Open-Pulse Contact)(Option)
Automatic Defrosting
Remote Control Adaptor
(Normal Open Contact)(Option)
Operation Automatic Operation Dlll-NET Compatible (Adaptor)(Option)
Programme Dry Function Remote
Controller
Wireless — Fan Only Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation — Priority-Room Setting # Cooling / Heating Mode Lock — Home Leave Operation — Indoor Unit On/Off Switch — Signal Reception Indicator — Temperature Display — Another Room Operation
Note: # : Holding Functions
— : No Functions
H
: Digital Only
List of Functions SiE12-411
6 List of Functions
1.1.2 R410A Series
Category Functions
FTKS20-35CVMB(9)(8)
FTKS50-71BVMB
CDKS25-60CVMB
Category Functions
FTKS20-35CVMB(9)(8)
FTKS50-71BVMB
CDKS25-60CVMB
Basic Function
Inverter (with Inverter Power Control)
###
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
———
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter — — — Operation Limit for Heating (°CWB)
———
Air Purifying Filter with Photocatalytic Deodorizing Function
##
PAM Control — — — Longlife Filter — — —
Compressor Oval Scroll Compressor — — — Ultra-Longlife Filter (Option) — — —
Swing Compressor — — — Mould Proof Air Filter ### Rotary Compressor — — — Wipe-clean Flat Panel ##— Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps ## Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — — Timer 24-Hour On/Off Timer ### Wide-Angle Louvers ## Night Set Mode ### Vertical Auto-Swing (Up and Down) ##— Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ###
Horizontal Auto-Swing (Right and Left)
#
Self-Diagnosis (Digital, LED) Display #
H#H#H
3-D Airflow # Wiring-Error Check — — — 3-Step Airflow (H/P Only)
———
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Comfort Control
Auto Fan Speed
###
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ### Flexible Voltage Correspondence ### Night Quiet Mode (Automatic) — — — High Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
———
Chargeless
———
Intelligent Eye ##— Power-Selection — — — Quick Warming Function
———
Remote Control
5-Rooms Centralized Controller (Option)
###
Hot-Start Function
———
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
###
Automatic Defrosting
———
Remote Control Adaptor (Normal Open Contact)(Option)
###
Operation Automatic Operation — — — Dlll-NET Compatible (Adaptor)(Option) ###
Programme Dry Function ###Remote
Controller
Wireless ###
Fan Only ### Wired — — —
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation ### Priority-Room Setting — — — Cooling / Heating Mode Lock — — — Home Leave Operation ### Indoor Unit On/Off Switch ### Signal Reception Indicator ### Temperature Display — — — Another Room Operation — — —
Note: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 7
Category Functions
FLKS25-60BVMB
FVKS25-50BVMB
3MKS50BVMB(8)
4MKS58BVMB(8)
4MKS75·90BVMB
Category Functions
FLKS25-60BVMB
FVKS25-50BVMB
3MKS50BVMB(8)
4MKS58BVMB(8)
4MKS75·90BVMB
Basic Function
Inverter (with Inverter Power Control)
## #
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
##
Operation Limit for Cooling (°CDB)
——
–10
~
46
Photocatalytic Deodorizing Filter
##
Operation Limit for Heating (°CWB)
—— —
Air Purifying Filter with Photocatalytic Deodorizing Function
—— —
PAM Control — — # Longlife Filter — —
Compressor Oval Scroll Compressor — — Ultra-Longlife Filter (Option) — —
Swing Compressor — — # Mould Proof Air Filter ## — Rotary Compressor — — Wipe-clean Flat Panel — — — Reluctance DC Motor — — # Washable Grille #
Comfortable Airflow
Power-Airflow Flap — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps — — Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — Timer 24-Hour On/Off Timer ## — Wide-Angle Louvers # Night Set Mode ## — Vertical Auto-Swing (Up and Down) ## Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ## —
Horizontal Auto-Swing (Right and Left)
—— —
Self-Diagnosis (Digital, LED) Display #
H#H
#
3-D Airflow — — Wiring-Error Check — — # 3-Step Airflow (H/P Only)
—— —
Anticorrosion Treatment of Outdoor Heat Exchanger
—— #
Comfort Control
Auto Fan Speed
##
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ## — Flexible Voltage Correspondence ## # Night Quiet Mode (Automatic) — — # H igh Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
—— #
Chargeless
—— #
Intelligent Eye — — Power-Selection — — — Quick Warming Function
—— —
Remote Control
5-Rooms Centralized Controller (Option)
##
Hot-Start Function
—— —
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
##
Automatic Defrosting
—— —
Remote Control Adaptor (Normal Open Contact)(Option)
##
Operation Automatic Operation — — Dlll-NET Compatible (Adaptor)(Option) ## —
Programme Dry Function ## — Remote
Controller
Wireless ##
Fan Only ## —Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
—— —
Inverter Powerful Operation ## — Priority-Room Setting — — # Cooling / Heating Mode Lock — — — Home Leave Operation ## — Indoor Unit On/Off Switch ## — Signal Reception Indicator ## — Temperature Display — — — Another Room Operation — —
Note: # : Holding Functions
— : No Functions
H
: Digital Only
List of Functions SiE12-411
8 List of Functions
1.2 Heat Pump Models
1.2.1 R22 Series
Category Functions
FTXE25/35BVMA
FTXD50-71BVMA
CDXD25-60CVMA
Category Functions
FTXE25/35BVMA
FTXD50-71BVMA
CDXD25-60CVMA
Basic Function
Inverter (with Inverter Power Control)
###
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
# ——
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter # —— Operation Limit for Heating (°CWB)
———
Air Purifying Filter with Photocatalytic Deodorizing Function
#
PAM Control — — — Longlife Filter — — —
Compressor Oval Scroll Compressor — — — Ultra-Longlife Filter (Option) — — —
Swing Compressor — — — Mould Proof Air Filter ##— Rotary Compressor — — — Wipe-clean Flat Panel ##— Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps ## Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — — Timer 24-Hour On/Off Timer ### Wide-Angle Louvers ## Night Set Mode ### Vertical Auto-Swing (Up and Down) ##— Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ###
Horizontal Auto-Swing (Right and Left)
#
Self-Diagnosis (Digital, LED) Display #
H#H#H
3-D Airflow # Wiring-Error Check — — — 3-Step Airflow (H/P Only)
———
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Comfort Control
Auto Fan Speed
###
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ### Flexible Voltage Correspondence ### Night Quiet Mode (Automatic) — — — High Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
———
Chargeless
———
Intelligent Eye ##— Power-Selection — — — Quick Warming Function
———
Remote Control
5-Rooms Centralized Controller (Option)
###
Hot-Start Function
###
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
###
Automatic Defrosting
———
Remote Control Adaptor (Normal Open Contact)(Option)
###
Operation Automatic Operation ### Dlll-NET Compatible (Adaptor)(Option) ###
Programme Dry Function ###Remote
Controller
Wireless ###
Fan Only ### Wired — — —
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation ### Priority-Room Setting — — — Cooling / Heating Mode Lock — — — Home Leave Operation ### Indoor Unit On/Off Switch ### Signal Reception Indicator ### Temperature Display — — — Another Room Operation — — —
Notes: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 9
Category Functions
FLX25-60AVMA
3MXD68BVMA
4MXD80BVMA
Category Functions
FLX25-60AVMA
3MXD68BVMA
4MXD80BVMA
Basic Function
Inverter (with Inverter Power Control)
##
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
#
Operation Limit for Cooling (°CDB)
–10
~
46
Photocatalytic Deodorizing Filter
#
Operation Limit for Heating (°CWB)
–15
~
15.5
Air Purifying Filter with Photocatalytic Deodorizing Function
PAM Control # Longlife Filter
Compressor Oval Scroll Compressor Ultra-Longlife Filter (Option)
Swing Compressor # Mould Proof Air Filter # Rotary Compressor Wipe-clean Flat Panel — Reluctance DC Motor # Washable Grille
Comfortable Airflow
Power-Airflow Flap Filter Cleaning Indicator — Power-Airflow Dual Flaps Good-Sleep Cooling Operation — Power-Airflow Diffuser Timer 24-Hour On/Off Timer # Wide-Angle Louvers Night Set Mode # Vertical Auto-Swing (Up and Down) # Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) #
Horizontal Auto-Swing (Right and Left)
——
Self-Diagnosis (Digital, LED) Display #
H1
#
3-D Airflow Wiring-Error Check # 3-Step Airflow (H/P Only)
——
Anticorrosion Treatment of Outdoor Heat Exchanger
#
Comfort Control
Auto Fan Speed
#
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
#
Indoor Unit Silent Operation # Flexible Voltage Correspondence ## Night Quiet Mode (Automatic) # High Ceiling Application — Outdoor Unit Silent Operation
(Manual)
#
Chargeless
H
2
Intelligent Eye Power-Selection — Quick Warming Function
#
Remote Control
5-Rooms Centralized Controller (Option)
#
Hot-Start Function
#
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
#
Automatic Defrosting
#
Remote Control Adaptor (Normal Open Contact)(Option)
#
Operation Automatic Operation # Dlll-NET Compatible (Adaptor)(Option) #
Programme Dry Function # Remote
Controller
Wireless #
Fan Only # —Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Inverter Powerful Operation # Priority-Room Setting # Cooling / Heating Mode Lock # Home Leave Operation # Indoor Unit On/Off Switch # Signal Reception Indicator # Temperature Display — Another Room Operation
Notes: # : Holding Functions
— : No Functions
H1 : Digital Only H2 : 68 class ; 30m / 80 class ; 40m
List of Functions SiE12-411
10 List of Functions
1.2.2 R410A Series
Category Functions
FTXS20-35CVMB(9)(8)
FTXS50-71BVMB
CDXS25-60CVMB
Category Functions
FTXS20-35CVMB(9)(8)
FTXS50-71BVMB
CDXS25-60CVMB
Basic Function
Inverter (with Inverter Power Control)
###
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
———
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter — — — Operation Limit for Heating (°CWB)
———
Air Purifying Filter with Photocatalytic Deodorizing Function
##
PAM Control — — — Longlife Filter — — —
Compressor Oval Scroll Compressor — — — Ultra-Longlife Filter (Option) — — —
Swing Compressor — — — Mould Proof Air Filter ### Rotary Compressor — — — Wipe-clean Flat Panel ##— Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps ## Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — — Timer 24-Hour On/Off Timer ### Wide-Angle Louvers ## Night Set Mode ### Vertical Auto-Swing (Up and Down) ##— Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ###
Horizontal Auto-Swing (Right and Left)
#
Self-Diagnosis (Digital, LED) Display #
H#H#H
3-D Airflow # Wiring-Error Check — — — 3-Step Airflow (H/P Only)
———
Anticorrosion Treatment of Outdoor Heat Exchanger
———
Comfort Control
Auto Fan Speed
###
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ### Flexible Voltage Correspondence ### Night Quiet Mode (Automatic) — — — High Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
———
Chargeless
———
Intelligent Eye ##— Power-Selection — — — Quick Warming Function
———
Remote Control
5-Rooms Centralized Controller (Option)
###
Hot-Start Function
###
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
###
Automatic Defrosting
———
Remote Control Adaptor (Normal Open Contact)(Option)
###
Operation Automatic Operation ### Dlll-NET Compatible (Adaptor)(Option) ###
Programme Dry Function ###Remote
Controller
Wireless ###
Fan Only ### Wired — — —
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation ### Priority-Room Setting — — — Cooling / Heating Mode Lock — — — Home Leave Operation ### Indoor Unit On/Off Switch ### Signal Reception Indicator ### Temperature Display — — — Another Room Operation — — —
Notes: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 11
Category Functions
FLXS25-60BVMB
FVXS25-50BVMB
3MXS52BVMB(8)
4MXS68BVMB9
4MXS80BVMB9
Category Functions
FLXS25-60BVMB
FVXS25-50BVMB
3MXS52BVMB(8)
4MXS68BVMB9
4MXS80BVMB9
Basic Function
Inverter (with Inverter Power Control) ## #
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
##
Operation Limit for Cooling (°CDB) — —
–10
~
46
Photocatalytic Deodorizing Filter
##
Operation Limit for Heating (°CWB) — —
–15
~
15.5
Air Purifying Filter with Photocatalytic Deodorizing Function
—— —
PAM Control — — # Longlife Filter
Compressor Oval Scroll Compressor — — Ultra-Longlife Filter (Option)
Swing Compressor — — # Mould Proof Air Filter ## — Rotary Compressor — — Wipe-clean Flat Panel — Reluctance DC Motor — — # Washable Grille #
Comfortable Airflow
Power-Airflow Flap — — Filter Cleaning Indicator — Power-Airflow Dual Flaps — — Good-Sleep Cooling Operation — Power-Airflow Diffuser — — Timer 24-Hour On/Off Timer ## — Wide-Angle Louvers # Night Set Mode ## — Vertical Auto-Swing (Up and
Down)
##
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure)
##
Horizontal Auto-Swing (Right and Left)
—— —
Self-Diagnosis (Digital, LED) Display
#H1#
H1
#
3-D Airflow — — Wiring-Error Check # 3-Step Airflow (H/P Only)
#
Anticorrosion Treatment of Outdoor Heat Exchanger
—— #
Comfort Control
Auto Fan Speed
##
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ## Flexible Voltage Correspondence ## # Night Quiet Mode (Automatic) — —
# High Ceiling Application
Outdoor Unit Silent Operation (Manual)
—— #
Chargeless
——
H
2
Intelligent Eye — — Power-Selection — Quick Warming Function
—— #
Remote Control
5-Rooms Centralized Controller (Option)
##
Hot-Start Function
##
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
##
Automatic Defrosting
—— #
Remote Control Adaptor (Normal Open Contact)(Option)
##
Operation Automatic Operation
##
Dlll-NET Compatible (Adaptor)(Option)
##
Programme Dry Function ## — Remote
Controller
Wireless ##
Fan Only ## —Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
—— —
Inverter Powerful Operation ## — Priority-Room Setting — — # Cooling / Heating Mode Lock — — # Home Leave Operation ## — Indoor Unit On/Off Switch ## — Signal Reception Indicator ## — Temperature Display — — — Another Room Operation — —
Notes: # : Holding Functions
— : No Functions
H1 : Digital Only H2 : 52, 68 class ; 30m / 80 class ; 40m
List of Functions SiE12-411
12 List of Functions
Category Functions
ATXS20·25·35CVMB(9)
Category Functions
ATXS20·25·35CVMB(9)
Basic Function
Inverter (with Inverter Power Control)
#
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
Operation Limit for Cooling (°CDB) Photocatalytic Deodorizing Filter — Operation Limit for Heating (°CWB)
Air Purifying Filter with Photocatalytic Deodorizing Function
#
PAM Control Longlife Filter
Compressor Oval Scroll Compressor Ultra-Longlife Filter (Option)
Swing Compressor Mould Proof Air Filter # Rotary Compressor Wipe-clean Flat Panel — Reluctance DC Motor Washable Grille #
Comfortable Airflow
Power Airflow Flap Filter Cleaning Indicator — Power-Airflow Dual Flaps # Good-Sleep Cooling Operation — Power-Airflow Diffuser Timer 24-Hour On/Off Timer # Wide-Angle Louvers # Night Set Mode # Vertical Auto-Swing (Up and Down) # Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) #
Horizontal Auto-Swing (Right and Left) Self-Diagnosis (Digital, LED) Display
#
H
3-D Airflow — 3-Step Airflow (H/P Only) Wiring-Error Check
Comfort Control
Auto Fan Speed
#
Anticorrosion Treatment of Outdoor Heat Exchanger
Indoor Unit Silent Operation # Flexibility Multi-Split / Split Type Compatible Indoor Unit # Night Quiet Mode (Automatic) Flexible Voltage Correspondence # Outdoor Unit Silent Operation (Manual) High Ceiling Application — Intelligent Eye # Chargeless — Quick Warming Function Power Selection — Hot-Start Function # Remote
Control
5-Rooms Centralized Controller (Option) #
Automatic Defrosting
Remote Control Adaptor (Normal Open-Pulse Contact) (Option)
#
Operation Automatic Operation
#
Remote Control Adaptor (Normal Open Contact) (Option)
#
Programme Dry Function # Dlll-NET Compatible (Adaptor) (Option) # Fan Only # Remote
Controller
Wireless #
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Wired
Inverter Powerful Operation # Priority-Room Setting — Cooling / Heating Mode Lock — Home Leave Operation # Indoor Unit On/Off Switch # Signal Reception Indicator # Temperature Display — Another Room Operation
Notes: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 13
Category Functions
ATXS50CVMB
3AMXS52BVMB
Category Functions
ATXS50CVMB
3AMXS52BVMB
Basic Function
Inverter (with Inverter Power Control) ##
Health & Clean
Air Purifying Filter with Bacteriostatic, Virustatic Functions
——
Operation Limit for Cooling (°CDB)
— –10~
46
Operation Limit for Heating (°CWB)
–15~
15.5
Photocatalytic Deodorizing Filter
PAM Control #
Air Purifying Filter with Photocatalytic Deodorizing Function
#
Compressor
Oval Scroll Compressor Longlife Filter — Swing Compressor # Ultra-Longlife Filter (Option) — Rotary Compressor Mold Proof Air Filter # Reluctance DC Motor # Wipe-clean Flat Panel
Comfortable Airflow
Power-Airflow Flap Washable Grille # Power-Airflow Dual Flaps # Filter Cleaning Indicator — Power-Airflow Diffuser Good-Sleep Cooling Operation — Wide-Angle Louvers #
Timer
24-Hour On/Off Timer # Vertical Auto-Swing (Up and Down) # Night Set Mode # Horizontal Auto-Swing (Right and Left) #
Worry Free “Reliability & Durability”
Auto-Restart (after Power Failure) # 3-D Airflow # Self-Diagnosis (Digital, LED) Display ## 3-Step Airflow (H/P Only) Wiring Error Check #
Comfort Control
Auto Fan Speed #
Anticorrosion Treatment of Outdoor
Heat Exchanger
#
Indoor Unit Silent Operation # Night Quiet Mode (Automatic) #
Flexibility
Multi-Split / Split Type Compatible
Indoor Unit
#
Outdoor Unit Silent Operation (Manual) — # Intelligent Eye # Flexible Voltage Correspondence ## Quick Warming Function # H igh Ceiling Application — Hot-Start Function # Chargeless 30m Automatic Defrosting # Power Selection
Operation
Automatic Operation #
Remote Control
5-Rooms Centralized Controller
(Option)
#
Programme Dry Function #
Remote Control Adaptor
(Normal Open-Pulse Contact)(Option)
#
Fan Only #
Lifestyle Convenience
New Powerful Operation (Non-Inverter) —
Remote Control Adaptor
(Normal Open Contact)(Option)
#
Inverter Powerful Operation # Priority-Room Setting # DIII-NET Compatible (Adaptor)(Option) # Cooling / Heating Mode Lock #
Remote Controller
Wireless # Home Leave Operation # —Wired Indoor Unit On/Off Switch # Signal Reception Indicator # Temperature Display — Another Room Operation
Note: # : Holding Functions
— : No Functions
List of Functions SiE12-411
14 List of Functions
Category Functions
FTXS25/35BVMA
FTXS50-71BVMA
CDXS25-60CVMA
Category Functions
FTXS25/35BVMA
FTXS50-71BVMA
CDXS25-60CVMA
Basic Function
Inverter (with Inverter Power Control)
###
Health & Clean
Air Purifying Filter with Bacteriostatic &
Virustatic Functions
# ——
Operation Limit for Cooling (°CDB) — — — Photocatalytic Deodorizing Filter # —— Operation Limit for Heating (°CWB)
———
Air Purifying Filter with Photocatalytic
Deodorizing Function
#
PAM Control — — — Longlife Filter — — —
Compressor Oval Scroll Compressor — — — Ultra-Longlife Filter (Option) — — —
Swing Compressor — — — Mould Proof Air Filter ### Rotary Compressor — — — Wipe-clean Flat Panel ##— Reluctance DC Motor — — — Washable Grille — — —
Comfortable Airflow
Power-Airflow Flap — — — Filter Cleaning Indicator — — — Power-Airflow Dual Flaps ## Good-Sleep Cooling Operation — — — Power-Airflow Diffuser — — — Timer 24-Hour On/Off Timer ### Wide-Angle Louvers ## Night Set Mode ### Vertical Auto-Swing (Up and Down) ##— Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ### Horizontal Auto-Swing (Right and Left)
#
Self-Diagnosis (Digital, LED) Display #
H#H#H
3-D Airflow # Wiring-Error Check — — — 3-Step Airflow (H/P Only)
———
Anticorrosion Treatment of Outdoor
Heat Exchanger
———
Comfort Control
Auto Fan Speed
###
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
##
Indoor Unit Silent Operation ### Flexible Voltage Correspondence ### Night Quiet Mode (Automatic) — — — High Ceiling Application — — — Outdoor Unit Silent Operation
(Manual)
———
Chargeless
———
Intelligent Eye ##— Power-Selection — — — Quick Warming Function
———
Remote Control
5-Rooms Centralized Controller
(Option)
###
Hot-Start Function
###
Remote Control Adaptor
(Normal Open-Pulse Contact)(Option)
###
Automatic Defrosting
———
Remote Control Adaptor
(Normal Open Contact)(Option)
###
Operation Automatic Operation ### Dlll-NET Compatible (Adaptor)(Option) ###
Programme Dry Function ###Remote
Controller
Wireless ### Fan Only ### Wired — — —
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
———
Inverter Powerful Operation ### Priority-Room Setting — — — Cooling / Heating Mode Lock — — — Home Leave Operation ### Indoor Unit On/Off Switch ### Signal Reception Indicator ### Temperature Display — — — Another Room Operation — — —
Notes: # : Holding Functions
— : No Functions
H
: Digital Only
SiE12-411 List of Functions
List of Functions 15
Category Functions
FLXS25-60BVMA
FVXS35/50BVMA
Category Functions
FLXS25-60BVMA
FVXS35/50BVMA
Basic Function
Inverter (with Inverter Power Control)
##
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
##
Operation Limit for Cooling (°CDB) — — Photocatalytic Deodorizing Filter ## Operation Limit for Heating (°CWB)
——
Air Purifying Filter with Photocatalytic Deodorizing Function
——
PAM Control — — Longlife Filter
Compressor Oval Scroll Compressor — — Ultra-Longlife Filter (Option)
Swing Compressor — — Mould Proof Air Filter ## Rotary Compressor — — Wipe-clean Flat Panel — Reluctance DC Motor — — Washable Grille #
Comfortable Airflow
Power-Airflow Flap — — Filter Cleaning Indicator — Power-Airflow Dual Flaps — — Good-Sleep Cooling Operation — Power-Airflow Diffuser — — Timer 24-Hour On/Off Timer ## Wide-Angle Louvers # Night Set Mode ## Vertical Auto-Swing (Up and Down) ##Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) ##
Horizontal Auto-Swing (Right and Left)
——
Self-Diagnosis (Digital, LED) Display #
H1#H1 3-D Airflow — — Wiring-Error Check — 3-Step Airflow (H/P Only)
#
Anticorrosion Treatment of Outdoor Heat Exchanger
——
Comfort Control
Auto Fan Speed
##
Flexibility Multi-Split / Split Type Compatible Indoor
Unit
#
Indoor Unit Silent Operation ## Flexible Voltage Correspondence ## Night Quiet Mode (Automatic) — — High Ceiling Application — Outdoor Unit Silent Operation (Manual) — — Chargeless — Intelligent Eye — — Power-Selection — Quick Warming Function — — Remote
Control
5-Rooms Centralized Controller (Option) ##
Hot-Start Function
##
Remote Control Adaptor (Normal Open-Pulse Contact)(Option)
##
Automatic Defrosting
——
Remote Control Adaptor (Normal Open Contact)(Option)
##
Operation Automatic Operation ## Dlll-NET Compatible (Adaptor)(Option) ##
Programme Dry Function ##Remote
Controller
Wireless ##
Fan Only ## Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
——
Inverter Powerful Operation ## Priority-Room Setting — — Cooling / Heating Mode Lock — — Home Leave Operation ## Indoor Unit On/Off Switch ## Signal Reception Indicator ## Temperature Display — — Another Room Operation — —
Notes: # : Holding Functions
— : No Functions
H1 : Digital Only
List of Functions SiE12-411
16 List of Functions
Category Functions
4MXS80CVMA
Category Functions
4MXS80CVMA
Basic Function
Inverter (with Inverter Power Control)
#
Health & Clean
Air Purifying Filter with Bacteriostatic & Virustatic Functions
Operation Limit for Cooling (°CDB) –10
~
46
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°CWB) –15
~
15.5
Air Purifying Filter with Photocatalytic Deodorizing Function
PAM Control # Longlife Filter
Compressor Oval Scroll Compressor Ultra-Longlife Filter (Option)
Swing Compressor # Mould Proof Air Filter — Rotary Compressor Wipe-clean Flat Panel — Reluctance DC Motor # Washable Grille
Comfortable Airflow
Power-Airflow Flap Filter Cleaning Indicator — Power-Airflow Dual Flaps Good-Sleep Cooling Operation — Power-Airflow Diffuser — Timer 24-Hour On/Off Timer — Wide-Angle Louvers Night Set Mode — Vertical Auto-Swing (Up and Down) — Worry Free
“Reliability & Durability”
Auto-Restart (after Power Failure) — Horizontal Auto-Swing (Right and Left) Self-Diagnosis (Digital, LED) Display # 3-D Airflow Wiring-Error Check # 3-Step Airflow (H/P Only)
Anticorrosion Treatment of Outdoor Heat
Exchanger
#
Comfort Control
Auto Fan Speed — Flexibility Multi-Split / Split Type Compatible Indoor Unit — Indoor Unit Silent Operation Flexible Voltage Correspondence # Night Quiet Mode (Automatic) # High Ceiling Application — Outdoor Unit Silent Operation (Manual) # Chargeless 40m Intelligent Eye Power-Selection — Quick Warming Function # Remote
Control
5-Rooms Centralized Controller (Option) — Hot-Start Function
Remote Control Adaptor
(Normal Open-Pulse Contact)(Option)
Automatic Defrosting
#
Remote Control Adaptor
(Normal Open Contact)(Option)
Operation Automatic Operation Dlll-NET Compatible (Adaptor)(Option)
Programme Dry Function — Remote
Controller
Wireless — Fan Only Wired
Lifestyle Convenience
New Powerful Operation (Non-Inverter)
Inverter Powerful Operation — Priority-Room Setting # Cooling / Heating Mode Lock # Home Leave Operation — Indoor Unit On/Off Switch — Signal Reception Indicator — Temperature Display — Another Room Operation
Notes: # : Holding Functions
— : No Functions
SiE12-411
Specifications 17
Part 2
Specifications
1. Specifications........................................................................................18
1.1 Indoor Units - Cooling Only ....................................................................18
1.2 Outdoor Units - Cooling Only .................................................................30
1.3 Indoor Units - Heat Pump.......................................................................36
1.4 Outdoor Units - Heat Pump....................................................................51
Specifications SiE12-411
18 Specifications
1. Specifications
1.1 Indoor Units - Cooling Only
Wall Mounted Type
50Hz 220-230-240V / 60Hz 220-230V
Model FTKE25BVM FTKE35BVM
Rated Capacity 2.5kW Class 3.5kW Class Front Panel Color White White
Air Flow Rates
m³/min
(cfm)
H 7.8 (275) 7.7 (272)
M 6.4 (226) 6.3 (222)
L 5.0 (177) 4.9 (173)
SL 4.3 (152) 4.4 (155)
Fan
Type Cross Flow Fan Cross Flow Fan Motor Output W 18 18
Speed Steps 5 Steps, Silent and Auto 5 Steps, Silent and Auto Air Direction Control Right, Left, Horizontal and Downward Right, Left, Horizontal and Downward Air Filter Removable-Washable-Mildew Proof Removable-Washable-Mildew Proof Running Current (Rated) A 0.17-0.18-0.18/0.21-0.21 0.17-0.18-0.18/0.21-0.21 Power Consumption (Rated) W 37-40-43/45-48 37-40-43/45-48 Power Factor % 98.9-96.6-99.5/97.4-99.4 98.9-96.6-99.5/97.4-99.4 Temperature Control Microcomputer Control Microcomputer Control Dimensions (H×W×D) mm 273×784×195 273×784×195 Packaged Dimensions (W×D×H) mm 834×325×258 834×325×258 Weight kg 7.5 7.5 Gross Weight kg 11 11 Operation
Sound
H/M/L/SL dBA 37/34/30/27 38/35/32/29 Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ 9.5 φ12.7
Drain mm
φ18.0 φ18.0
Drawing No. 3D040693 3D040694
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Model FTKD50BVM FTKD60BVM
Rated Capacity 5.0kW Class 6.0kW Class Front Panel Color White White
Air Flow Rates
m³/min
(cfm)
H 16.8 (593) 17.5 (618)
M 14.0 (494) 14.6 (515)
L 11.8 (417) 12.2 (431)
SL 10.4 (367) 10.8 (381)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 43 43
Speed Steps 5 Steps, Silent and Auto 5 Steps, Silent and Auto Air Direction Control Right, Left, Horizontal and Downward Right, Left, Horizontal and Downward Air Filter Removable-Washable-Mildew Proof Removable-Washable-Mildew Proof Running Current (Rated) A 0.19-0.18-0.17/0.19-0.18 0.21-0.20-0.19/0.21-0.20 Power Consumption (Rated) W 40 45 Power Factor % 95.7-96.6-98.0/95.7-96.6 97.4-97.8-98.7/97.4-97.8 Temperature Control Microcomputer Control Microcomputer Control Dimensions (H×W×D) mm 290× 1,050×238 290×1,050×238 Packaged Dimensions (W×D×H) mm 1,147×366×337 1,147×366×337 Weight kg 12 12 Gross Weight kg 17 17 Operation
Sound
H/M/L/SL dBA 44/40/35/32 45/41/36/33 Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ12.7 φ15.9
Drain mm
φ18.0 φ18.0
Drawing No. 3D040814 3D040815
SiE12-411 Specifications
Specifications 19
50Hz 220-230-240V / 60Hz 220-230V
Model FTKD71BVM
Rated Capacity 7.1kW Class Front Panel Color White
Air Flow Rates
m³/min
(cfm)
H 18.0 (635)
M 15.1 (533)
L 12.7 (448)
SL 11.3 (399)
Fan
Type Cross Flow Fan
Motor Output W 43
Speed Steps 5 Steps, Silent and Auto Air Direction Control Right, Left, Horizontal and Downward Air Filter Removable-Washable-Mildew Proof Running Current (Rated) A 0.23-0.22-0.21/0.23-0.22 Power Consumption (Rated) W 50 Power Factor % 98.8-98.8-99.2/98.8-98.8 Temperature Control Microcomputer Control Dimensions (H×W×D) mm 290×1,050×238 Packaged Dimensions (W×D×H) mm 1,147×366×337 Weight kg 12 Gross Weight kg 17 Operation
Sound
H/M/L/SL dBA 46/42/37/34 Heat Insulation Both Liquid and Gas Pipes
Piping Connection
Liquid mm
φ
9.5
Gas mm
φ15.9
Drain mm
φ18.0
Drawing No. 3D040816
Conversion Formulae