Daikin BRP069C51 Installation manuals

Installation manual
Wireless LAN connecting adapter
BRP069C51
Installation manual
Wireless LAN connecting adapter
English

Table of contents

Table of contents

1 About this document 2

2 Specific installer safety instructions 2

3 About the adapter 3
3.1 Components .............................................................................. 3
3.2 Basic parameters ...................................................................... 3
3.3 Compatibility.............................................................................. 3
4 About the box 3
4.1 To unpack the adapter .............................................................. 3
5 Installation 3
5.1 Precautions when installing the adapter.................................... 3
5.2 Preparing the installation site .................................................... 3
5.2.1 Installation site requirements ...................................... 3
5.3 Connecting the electrical wiring................................................. 3
5.3.1 Overview of electrical connections.............................. 4
5.3.2 To connect the adapter with the unit........................... 4
5.4 Closing the adapter ................................................................... 4
5.4.1 To close the adapter ................................................... 4
5.5 Mounting the adapter ................................................................ 4
5.5.1 To mount the adapter.................................................. 4
6 Starting up the system 5
7 Configuration 5
7.1 To install the Daikin Residential Controller application ............. 5
7.2 To configure the adapter ........................................................... 5
8 Hand-over to the user 5
INFORMATION
For details on specifications, setting methods, FAQ, troubleshooting tips and the latest version of this manual, visit http://www.onlinecontroller.daikineurope.com/
Latest revisions of the supplied documentation may be available on the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages are translations.
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Installation (see "5Installation"[43])
DANGER: RISK OF ELECTROCUTION
▪ Turn off the power supply before installing the adapter.
▪ Do NOT handle the adapter with wet hands.
▪ Do NOT let the adapter get wet.
▪ Do NOT disassemble, modify or repair the adapter.
▪ Grip the connector when disconnecting the connection
cable.
▪ Turn off the power supply in case the adapter gets
damaged.
1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set consists of:
General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the indoor unit)
Installation manual:
▪ Installation instructions
▪ Format: Paper (supplied in the kit)
Installer reference guide:
▪ Installation instructions, configuration, application guidelines,…
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
Declaration of conformity:
INFORMATION: Declaration of conformity
Hereby, Daikin Industries Czech Republic s.r.o. declares that the radio equipment type BRP069C41 is in compliance with the Directive 2014/53/EU. The original declaration of conformity is available from http://www.daikineurope.com/
support-and-manuals/product-information/.
DANGER: RISK OF ELECTROCUTION
Do NOT turn on the power supply before you have connected the electrical wiring, closed the adapter, and mounted it to the indoor unit.
Hand over to the user (see "8Hand-over to the user"[45])
DANGER
▪ Do not disassemble, modify, or repair the adapter. This
can cause fire, electric shock, or injury.
▪ Do not allow the adapter to get wet or use it when
bathing or doing similar activities with water. This can cause electric shock or fire.
▪ Do not use the adapter near medical equipment, or
persons using cardiac pacemakers or defibrillators. This can cause life-threatening electromagnetic interference.
▪ Do not use the adapter near auto-control equipment
such as automatic doors or fire alarm equipment. This can cause accidents due to erroneous equipment behaviour.
▪ In case of abnormal odour or sound, overheating, or
smoke coming out of the adapter, immediately disconnect the indoor unit from its power supply. Otherwise, this can lead to fire or malfunction. If this happens, consult your dealer.
▪ In case you drop or damage the adapter, disconnect
the indoor unit from its power supply. Otherwise, this can lead to fire or malfunction. If this happens, consult your dealer.
Installation manual
Wireless LAN connecting adapter
BRP069C51
4P567679-2C – 2020.05
3 About the adapter
ca db
h
e f g
i
Wireless LAN adapter to connect the heat pump system to the Daikin Cloud via the internet, allowing for control of the heat pump system with the Daikin Residential Controller app.

3.1 Components

a RUN lamp (orange). Lights when connecting to a router
(wireless LAN access point).
b AP lamp c SETUP button. Use when connecting to a router
(wireless LAN access point).
d MODE button e POWER button. Turns the WLAN adapter ON/OFF when
pressed.

3 About the adapter

a Adapter b Screws (M3×8) for the adapter c Adapter holder with double face tape d Mounting screws for the holder (M3×16) e Cable tie mounting
f Cable tie g Connection cable h Serial number sticker (SSID, KEY, MAC)
i Installation manual

3.2 Basic parameters

Parameter Value
Frequency range 2400MHz~2483.5MHz
Radio protocol IEEE 802.11b/g/n
Radio frequency channel 13ch
Output power 13dBm
Effective radiated power 15dBm (11b) / 14dBm (11g) /
14dBm (11n)
Power supply DC 14 V / 100 mA

3.3 Compatibility

Make sure the indoor unit is compatible for use with the adapter. For the latest details about installation of the adapter and applicable units, visit http://www.onlinecontroller.daikineurope.com/.

4 About the box

4.1 To unpack the adapter

1 Open the box.
2 Take out the adapter.
3 Separate the accessories.

5 Installation

5.1 Precautions when installing the adapter

DANGER: RISK OF ELECTROCUTION
▪ Turn off the power supply before installing the adapter.
▪ Do NOT handle the adapter with wet hands.
▪ Do NOT let the adapter get wet.
▪ Do NOT disassemble, modify or repair the adapter.
▪ Grip the connector when disconnecting the connection
cable.
▪ Turn off the power supply in case the adapter gets
damaged.

5.2 Preparing the installation site

5.2.1 Installation site requirements

The adapter is designed to be mounted to the indoor unit, in dry, indoor locations only.

5.3 Connecting the electrical wiring

DANGER: RISK OF ELECTROCUTION
Do NOT turn on the power supply before you have connected the electrical wiring, closed the adapter, and mounted it to the indoor unit.
BRP069C51 Wireless LAN connecting adapter 4P567679-2C – 2020.05