Table of contents
Table of contents
1 About this document 2
2 Specific installer safety instructions 2
3 About the adapter 3
3.1 Components .............................................................................. 3
3.2 Basic parameters ...................................................................... 3
3.3 Compatibility.............................................................................. 3
4 About the box 3
4.1 To unpack the adapter .............................................................. 3
5 Installation 3
5.1 Precautions when installing the adapter.................................... 3
5.2 Preparing the installation site .................................................... 3
5.2.1 Installation site requirements ...................................... 3
5.3 Connecting the electrical wiring................................................. 3
5.3.1 Overview of electrical connections.............................. 4
5.3.2 To connect the adapter with the unit........................... 4
5.4 Closing the adapter ................................................................... 4
5.4.1 To close the adapter ................................................... 4
5.5 Mounting the adapter ................................................................ 4
5.5.1 To mount the adapter.................................................. 4
6 Starting up the system 5
7 Configuration 5
7.1 To install the Daikin Residential Controller application ............. 5
7.2 To configure the adapter ........................................................... 5
8 Hand-over to the user 5
INFORMATION
For details on specifications, setting methods, FAQ,
troubleshooting tips and the latest version of this manual,
visit http://www.onlinecontroller.daikineurope.com/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
The original documentation is written in English. All other languages
are translations.
2 Specific installer safety
instructions
Always observe the following safety instructions and regulations.
Installation (see "5Installation"[43])
DANGER: RISK OF ELECTROCUTION
▪ Turn off the power supply before installing the adapter.
▪ Do NOT handle the adapter with wet hands.
▪ Do NOT let the adapter get wet.
▪ Do NOT disassemble, modify or repair the adapter.
▪ Grip the connector when disconnecting the connection
cable.
▪ Turn off the power supply in case the adapter gets
damaged.
1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the indoor unit)
▪ Installation manual:
▪ Installation instructions
▪ Format: Paper (supplied in the kit)
▪ Installer reference guide:
▪ Installation instructions, configuration, application guidelines,…
▪ Format: Digital files on http://www.daikineurope.com/support-
and-manuals/product-information/
▪ Declaration of conformity:
INFORMATION: Declaration of conformity
Hereby, Daikin Industries Czech Republic s.r.o. declares
that the radio equipment type BRP069C41 is in compliance
with the Directive 2014/53/EU. The original declaration of
conformity is available from http://www.daikineurope.com/
support-and-manuals/product-information/.
DANGER: RISK OF ELECTROCUTION
Do NOT turn on the power supply before you have
connected the electrical wiring, closed the adapter, and
mounted it to the indoor unit.
Hand over to the user (see "8Hand-over to the user"[45])
DANGER
▪ Do not disassemble, modify, or repair the adapter. This
can cause fire, electric shock, or injury.
▪ Do not allow the adapter to get wet or use it when
bathing or doing similar activities with water. This can
cause electric shock or fire.
▪ Do not use the adapter near medical equipment, or
persons using cardiac pacemakers or defibrillators.
This can cause life-threatening electromagnetic
interference.
▪ Do not use the adapter near auto-control equipment
such as automatic doors or fire alarm equipment. This
can cause accidents due to erroneous equipment
behaviour.
▪ In case of abnormal odour or sound, overheating, or
smoke coming out of the adapter, immediately
disconnect the indoor unit from its power supply.
Otherwise, this can lead to fire or malfunction. If this
happens, consult your dealer.
▪ In case you drop or damage the adapter, disconnect
the indoor unit from its power supply. Otherwise, this
can lead to fire or malfunction. If this happens, consult
your dealer.
Installation manual
2
Wireless LAN connecting adapter
BRP069C51
4P567679-2C – 2020.05
3 About the adapter
Wireless LAN adapter to connect the heat pump system to the
Daikin Cloud via the internet, allowing for control of the heat pump
system with the Daikin Residential Controller app.
3.1 Components
a RUN lamp (orange). Lights when connecting to a router
(wireless LAN access point).
b AP lamp
c SETUP button. Use when connecting to a router
(wireless LAN access point).
d MODE button
e POWER button. Turns the WLAN adapter ON/OFF when
pressed.
3 About the adapter
a Adapter
b Screws (M3×8) for the adapter
c Adapter holder with double face tape
d Mounting screws for the holder (M3×16)
e Cable tie mounting
f Cable tie
g Connection cable
h Serial number sticker (SSID, KEY, MAC)
i Installation manual
3.2 Basic parameters
Parameter Value
Frequency range 2400MHz~2483.5MHz
Radio protocol IEEE 802.11b/g/n
Radio frequency channel 13ch
Output power 13dBm
Effective radiated power 15dBm (11b) / 14dBm (11g) /
14dBm (11n)
Power supply DC 14 V / 100 mA
3.3 Compatibility
Make sure the indoor unit is compatible for use with the adapter. For
the latest details about installation of the adapter and applicable
units, visit http://www.onlinecontroller.daikineurope.com/.
4 About the box
4.1 To unpack the adapter
1 Open the box.
2 Take out the adapter.
3 Separate the accessories.
5 Installation
5.1 Precautions when installing the
adapter
DANGER: RISK OF ELECTROCUTION
▪ Turn off the power supply before installing the adapter.
▪ Do NOT handle the adapter with wet hands.
▪ Do NOT let the adapter get wet.
▪ Do NOT disassemble, modify or repair the adapter.
▪ Grip the connector when disconnecting the connection
cable.
▪ Turn off the power supply in case the adapter gets
damaged.
5.2 Preparing the installation site
5.2.1 Installation site requirements
The adapter is designed to be mounted to the indoor unit, in dry,
indoor locations only.
5.3 Connecting the electrical wiring
DANGER: RISK OF ELECTROCUTION
Do NOT turn on the power supply before you have
connected the electrical wiring, closed the adapter, and
mounted it to the indoor unit.
BRP069C51
Wireless LAN connecting adapter
4P567679-2C – 2020.05
Installation manual
3