Daikin 5MKS100LVMA, 3MKS58LVMA, 3MXS52LVMA, 3MXS68LVMA, 4MXS80LVMA Overview

...
Multi-Split Type Air Conditioners L series With DC Inverter and Swing Compressor Cooling Only & Heat Pump [50 Hz]
The Comfort and Luxury You Deserve
All rights reserved 09/12 DN
c
Dealer
Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea, direct exposure to sea breeze should be avoided. If you need to install the outdoor unit close to the sea, contact your local distributor.
Cautions on product corrosion
Specifications, designs and other content appearing in this brochure are current as of September 2012 but subject to change without notice.
Daikin Australia
Pty Limited (ISO9001)
QEC23256 May 31, 2006
Sydney, Brisbane, Adelaide,
Melbourne, Newcastle,
Townsville, Perth, Auckland
Daikin Australia
Pty Limited (ISO14001)
CEM20437 October 27, 2006 Sydney, Brisbane, Melbourne,
Adelaide
Organization: DAIKIN INDUSTRIES, LTD. AIR CONDITIONING MANUFACTURING DIVISION
Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF COMMERCIAL AIR CONDITIONING, HEATING, COOLING, REFRIGERATING EQUIPMENT, HEATING EQUIPMENT, RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT RECLAIM VENTILATION, AIR CLEANING EQUIPMENT, COMPRESSORS AND VALVES.
Organization: DAIKIN INDUSTRIES (THAILAND) LTD.
Scope of Registration: THE DESIGN/DEVELOPMENT AND MANUFACTURE OF AIR CONDITIONERS AND THE COMPONENTS INCLUDING COMPRESSORS USED FOR THEM
All of the Daikin Group’s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.
Warning
Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion and may have resultant impacts on warranty.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
JQA-1452JMI-0107
PCRAU0644G
Contents
Air condition multiple rooms in your home with a single outdoor unit.
Air condition multiple rooms in your home with a single outdoor unit.
The Daikin Super Multi NX lets you build a highly efficient multi room air conditioning system by connecting up to five indoor units to a single outdoor unit. The series includes a wide variety of indoor units, so it is easy to select a model that blends in unobtrusively. A single compact outdoor unit allows you to make more efficient use of available space in the installation location, such as a balcony. The individual indoor units in different rooms—the living room, study, and bedrooms, for example—can be controlled independently to match your family’s lifestyle. Super Multi NX can make your home more comfortable.
Super Multi NX is the knowledgeable choice.
Concepts
Main features
Product lineup
Functions
Specifications
Options
Capacity tables
3
5
9
19
23
26
27
1
2
Concepts Concepts
Key concepts for Super Multi NX
Enjoy the comfort and luxury of your dreams.
In 1969, Daikin developed the first multi room air conditioning system in Japan that needed
just one outdoor unit. Over the ensuing 40 years, Daikin has built an enviable reputation with the constant progress of its technology. Super Multi NX requires only a single outdoor unit to maintain comfort in up to five rooms. Where outdoor unit installation space is limited, it is the ideal choice. Air conditioner settings for each room can be controlled individually to
suit the preference of each person. While optimising personal comfort,
Super Multi NX uses DC inverter technology, making it energy efficient.
5MK(X)S series
The DC motor, swing compressor and other advanced technologies make for energy-efficient operation that achieves high COPs.
The quiet operation mode helps create a more pleasant living environment. DC inverter power control provides comfortable temperature control.
The wide range of indoor unit options provides ample choice. A single compact outdoor unit reduces installation space requirements, while long maximum piping lengths provide flexibility for connections.
The individual indoor units in different rooms can be controlled independently. The priority-room setting function lets you specify a room to receive preference in air conditioning operation.
Up to 5 indoor units can be connected.
4MK(X)S series
Up to 4 indoor units can be connected.
3MK(X)S series
Up to 3 indoor units can be connected.
Connect 5 indoor units to a single outdoor unit
New
New
3
4
5 6
2
1
3
What is COP?
An air conditioner's COP (coefficient of performance) indicates how efficiently it uses energy. A high COP means high energy efficiency.
COP =
Capacity (W)
Power consumption (W)
Main features Main features
ntelligent technologies
High energy efficiency through advanced
technologies delivers high COP.
deal environment
Convenient features to create your
ideal environment
* During rated capacity operation of 5 indoor units (2.0 + 2.0 + 2.0 + 2.0 + 2.0 kW class).
High energy efficiency
COP
4.583.65
Cooling operation Heating operation
5MXS100LVMA
Pulse Amplitude Modulation (PAM) control reduces energy loss by controlling the amount of switching on/off of the converter.
50
0 30 60 90 120
60
70
80
90
Small load Large load Low capacity High capacity
Reluctance DC Motor
Conventional
DC motor
More than 20%
AC motor
Rotational speed (rps)
Motor efficiency (%)
Loss
Loss
Power supply
POWER
Power factor
Converter efficiency
Inverter efficiency
Swing compressor
Reluctance DC motor
PAM control
Daikin energy-efficient technologies
The swing compressor can reduce operational vibration and sound because its piston moves smoothly inside the compressor.
Swing bush
Integral piston of blade and roller
Refrigerant gas
Reluctance DC motor
Swing compressor
Thanks to its smooth rotation, the swing compressor decreases friction and vibration. It also prevents the leakage of refrigerant gas during compression. These advantages provide quiet and efficient operation.
The use of a Reluctance DC motor with neodymium magnets
*1
for our compressors has improved motor efficiency by more than 20% compared to AC motors. The high torque
*2
and stronger magnetic force produced is beneficial particularly at low load conditions.
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite
magnet.
*2. The torque created by the change in power between the iron and magnet parts.
Note: Data are based on studies conducted under
controlled conditions at a Daikin laboratory.
Neodymium magnets are used in the pink-coloured area.
1
2
3
Indoor unit
During cooling operation
Set temp.
Temp.
Time
Starts
Too cool
Not cool
Non-inverter air conditioners can only perform simple on/off operation. They start operation when the temperature rises and stop when the room reaches the set temperature and then switch to low-capacity operation. As a result, inverter air conditioners are more energy efficient and comfortable than non-inverter air conditioners.
Non-inverter type
DC inverter type
* This diagram is a representation for illustrative purposes only.
Quiet operation
Comfortable temperature control
Wide operation range
Outdoor unit
Rustling of leaves
Quiet library
Midnight in the suburbs Quiet office
22 dB (A) is so quiet you can even hear whispers
50403020
(dB(A))
22 dB (A)
Heat pump type 4MXS80
With Super Multi NX, cooling operation is possible even during lower outdoor temperatures.
Note: This information is for heat pump type.
Super Multi NX achieves a quiet sound level of 43 dB (A) during Outdoor Unit Quiet Operation or Night Quiet Mode of the 3MXS52 during cooling operation.
Note: Capacity may decrease when quiet functions are selected.
Super Multi NX offers the quiet sound level of 22 dB (A) during Indoor Unit Quiet Operation of the FTXS20/25 during cooling operation.
Note: Capacity may decrease when quiet functions are selected.
-10
0
10
20
30
40
50
-20
-10
0
10
20
15.5°C WB
Heating
46°C DB
Cooling
-10°C DB
–15°C WB
Outdoor temperature (°C DB)
Outdoor temperature (°C WB)
7
8
Only 240 mm is required above the ceiling for installation.
The ample maximum piping length of 80 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space.
Max. piping length
Total
For one room
25 m
3MKS58
3MXS52
50 m
3MKS68
3MXS68
60 m
4MKS80
4MXS80
70 m
5MKS100
5MXS100
80 m
30 m
The stylish panel design of the wall­mounted type provides an excellent match for interiors.
Model name
Stylish indoor units for elegant interiors
Compact outdoor units for a less obtrusive exterior look
Long piping lengths for installation flexibility
The system requires only a single outdoor unit. The compact design provides installation flexibility and takes up less space, for a less obtrusive exterior look.
The compact and simple design blends in with the type of room.
Room C
Room B
Room A
Priority room
Living room
Power Up!
Priority room
Living room
Room A
Room B
Room C
Priority setting with Inverter Powerful Operation
Priority setting with Outdoor Unit Quiet Operation
When Inverter Powerful Operation is selected in the priority room, the indoor unit capacity in the priority room is increased by shifting capacity from units in other rooms. After 20 minutes, all units automatically return to their original settings.
Note: Capacity in other rooms may decrease slightly.
Priority-Room Setting also allows Outdoor Unit Quiet Operation to be selected by one command* from the priority room. * If Priority-Room Setting has not been set, the Outdoor Unit Quiet Operation button must be pushed on the wireless remote controller of all indoor units operating at that time.
Convenient remote controllers
Preferential air conditioning
Priority setting with operation mode
The operation mode (cooling/heating) of the indoor unit in the priority room is given preference. When the operation modes of the units in other rooms are different from the unit in the priority room, the units in the other rooms wait on standby.
Note: Operation mode can not be changed from other rooms.
5-room centralised controller
(option)
Central remote controller
(option)
Unified on/off controller
(option)
Wired remote controller
(option)
Wireless remote controller
Initial setting required during installation
Priority-Room Setting delivers priority capacity to a prioritised room when using multi-split air conditioners. After a priority room is selected, it receives preferential air-conditioning plus priority control over the 3 functions below.
1
2
3
A variety of convenient controller systems permit individual control of settings such as temperature, airflow volume, and operation duration.
Wide range of choices to match your interior
Individual control for each room to match your family’s lifestyle
Main features Main features
nterior & exterior flexibility
ndividual control
9
10
Outdoor unit
Indoor unit
Connectable to up to 3 indoor units
Wall-mounted type
Connectable to up to 4 indoor units
7.1 kW6.0 kW5.0 kW3.5 kW2.5 kW
Cooling only
Heat pump
FTKS35KVMA
FTXS35KVMA
FTKS25KVMA
FTXS25KVMA
FTKS20KVMA
FTXS20KVMA
Cooling only
Heat pump
FTKS71KAVMA
FTXS71KAVMA
FTKS60KAVMA
FTXS60KAVMA
FTKS50KAVMA
FTXS50KAVMA
Model name
Model
Capacity class
3MKS58LVMA
3MXS52LVMA
3MKS68LVMA
3MXS68LVMA
Cooling only
Heat pump
4MKS80LVMA
4MXS80LVMA
5.8 kW
Max. piping length
50 m
Max. height difference
15 m
5.2 kW
6.8 kW
6.8 kW
8.0 kW
8.0 kW
50 m
60 m
60 m
70 m
70 m
15 m
15 m
15 m
15 m
15 m
Cooling only
Heat pump
CDKS35EAVMA
CDXS35EAVMA
CDKS25EAVMA
CDXS25EAVMA
Cooling only
Heat pump
CDKS60CVMA
FDXS60CVMA
CDKS50CVMA
FDXS50CVMA
CDKS35CVMA
FDXS35CVMA
CDKS25CVMA
FDXS25CVMA
Heat pump
FVXS50KV1AFVXS35KV1AFVXS25KV1A
Heat pump
FLXS60GVMAFLXS50GVMAFLXS35GVMAFLXS25BVMA
Cooling only
Heat pump
FFQ60BV1B
FFQ60BV1B
FFQ50BV1B
FFQ50BV1B
FFQ35BV1B
FFQ35BV1B
FFQ25BV1B
FFQ25BV1B
Cooling only
Heat pump
Duct-connected type
Floor-standing type
Floor/ceiling-suspended dual type
Compact multi flow ceiling-mounted cassette type
700 mm width
900/1,100 mm width
Cooling only
Possible combinations for indoor and outdoor units
Heat pump
Model
Capacity class
Model
Capacity class
Connectable to up to 5 indoor units
2.0 kW
7.1 kW6.0 kW
5.0 kW
3.5 kW2.5 kW2.0 kW
3MKS58L 3MKS68L 4MKS80L
3MXS52L 3MXS68L 4MXS80L
Option
5MKS100L
5MXS100L
Cooling only
Heat pump
5MKS100LVMA
5MXS100LVMA
10.0 kW
10.0 kW
80 m
80 m
15 m
15 m
An attractive match for large rooms with refined interiors is provided by the stylish panel design.
Wall-mounted type
Fits in shallow ceiling recesses only 240 mm deep thanks to the new slim and compact design.
Duct-connected type
Unobtrusive and convenient with a floor­standing compact design.
Floor-standing type
Chose either ceiling-suspended or floor-level installation for this attractive model with a beautiful, rounded design.
Floor/ceiling-suspended dual type
Compact multi flow ceiling­mounted cassette type
The compact and flexible design is suited to commercial spaces such as offices.
Product lineup Product lineup
A wide range of models to choose from that deliver comfort and convenience An array of indoor unit models with innovative and attractive designs make
it easy to find the ideal match for each room in your home.
New
New
11
12
Titanium Apatite Photocatalytic Air-purifying Filter
Air filter
Catches dust
Wall-Mounted Type
6.0 kW class
FTKS60KAVMA
FTXS60KAVMA
5.0 kW class
FTKS50KAVMA
FTXS50KAVMA
7.1 kW class
FTKS71KAVMA
FTXS71KAVMA
Cooling only
Heat pump
2.5 kW class
FTKS25KVMA
FTXS25KVMA
2.0 kW class
FTKS20KVMA
FTXS20KVMA
3.5 kW class
FTKS35KVMA
FTXS35KVMA
Cooling only
Heat pump
Flat panel can be cleaned with just a single pass of a cloth across its smooth surface.
Indoor unit lineup Indoor unit lineup
Vertical and horizontal airflow is controlled by Power-Airflow Dual Flaps and Wide­Angle Louvers working in tandem, realising even distribution of air.
Uses a Titanium Apatite Photocatalytic Air-Purifying Filter. Titanium apatite is a photocatalytic material with high adsorption power. It effectively adsorbs and removes bacteria.
These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal Test Testing method: dropping method Result certificate: No. 012553-1 and 012553-2 Testing organisation: Japan Spinners Inspecting Foundation
Evenly distributed air
3-D airflow
Comfort airflow mode
Clean air
Easy cleaning
Wall-mounted type indoor units achieve quiet sound level of 22 dB (A) during Indoor Unit Quiet Operation.
During cooling operation
Quiet operation
Intelligent eye
Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it
adjusts the temperature by ± 2˚C for energy efficiency.
Econo mode
Econo Mode is a function that reduces the maximum running current and the maximum power consumption of the outdoor unit to the rated values.
This mode is useful for preventing circuit breakers from being overloaded by the use of multiple air conditioners and other electrical devices. The function is easily activated from the remote controller by pushing the ECONO button.
• This diagram is a representation for illustrative purposes only.
Maximum capacity decreases during Econo Mode, requiring more time to reach the set temperature.
Running current and power consumption
From start-up until set temperature is reached
Maximum
Rated
Maximum during normal operation
Time
Normal operation
Econo Mode
Maximum during Econo Mode
Option
During cooling the Power-Airflow Dual Flaps flatten out to deliver air to the farthest corners of the room.
During heating the near-vertical flaps direct air to the floor to quickly warm the room.
*
* Heat pump only
3-D Airflow combines Vertical and Horizontal Auto­Swing to circulate air to every part of a room for uniform cooling/heating of even large spaces.
Comfort Airflow Mode prevents uncomfortable drafts from blowing directly on to your body. With this
function, when you press the COMFORT button during cooling operation, the flap moves upward to prevent direct cold drafts. During heating operation, it also moves downward to prevent direct drafts and deliver warm air to the floor.
Cooling operation Heating operation
When you are in the room.
When you go out.
A luminescent material is used for the buttons on the surface.
The LCD panel with backlight
Weekly Timer
operation button
The remote controller with a backlit liquid crystal display and luminescent control buttons also
features a built-in Weekly Timer that can be programmed to suit your lifestyle, with up to four actions per day for each day of the week. This controller not only allows you to programme on and off times, but also the desired temperature during those times. Furthermore, the ‘copy’ function enables any daily programme to be replicated on any other day or days as required.
Weekly timer
*
* Heat pump only
* Capacity may be affected.
FTXS25FTXS20 FTXS35
42/26/23 dB(A)
(H/L/SL)
38/25/22 dB(A)
Option
Loading...
+ 15 hidden pages