• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING
CAUTION...............Failure to follow any of CAUTION may in some cases result in grave consequences.
...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction.Be sure to establish an earth connection.Never attempt.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use
and cleaning of the unit according to the Operation Manual.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the unit’s weight.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
connecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the
electrical covers or panels.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
Firmly clamp the inter-
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
• Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals.
Small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around
the unit clean.
1■English
Page 4
Accessories
Accessories supplied with the outdoor unit:
(A) Installation Manual(B) Drain plug
(C) Reducer assy
There is on the bottom packing case.
(4MXS68*, 4MKS75*)
(E) Refrigerant charge label
1
1
There is on the bottom packing case.
(D) Screw bag
(For fixing electrical wire anchor bands)
1
There is on the bottom packing case.
1
1
Precautions for Selecting the Location
1) Choose a place solid enough to bear the weight and vibration of the unit, where the operation noise will not be amplified.
2) Choose a location where the hot air discharged from the unit or the operation noise, will not cause a nuisance to the
neighbors of the user.
3) Avoid places near a bedroom and the like, so that the operation noise will cause no trouble.
4) There must be sufficient spaces for carrying the unit into and out of the site.
5) There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of flammable gas leakage in a nearby place.
Locate the unit so that the noise and the discharged hot air will not annoy the neighbors.
7) Install units, power cords and inter-unit cables at least 3 meter away from television and radio sets. This is to prevent
interference to images and sounds. (Noises may be heard even if they are more than 3 meter away depending on radio
wave conditions.)
8) In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may shorten the life of the air conditioner.
9) Since drain flows out of the outdoor unit, do not place under the unit anything which must be kept away from moisture.
NOTE:
Cannot be installed hanging from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient temperature, be sure to follow the instructions described below.
1) To prevent exposure to wind, install the outdoor unit with its suction side facing the wall.
2) Never install the outdoor unit at a site where the suction side may
be exposed directly to wind.
3) To prevent exposure to wind, it is recommended to install a baffle
plate on the air discharge side of the outdoor unit.
4) In heavy snowfall areas, select an installation site where the snow
will not affect the unit.
■English2
Construct a large canopy.
Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow.
Page 5
Indoor/Outdoor Unit
Installation Drawings
For installation of the indoor units, refer to the installation manual which was provided with the units.
(The diagram shows a wall-mounted indoor unit.)
CAUTION
1) Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work without connecting the
indoor unit in order to add another indoor unit later.
Make sure no dirt or moisture gets into either side of the embedded branch piping.
See “7 Refrigerant piping work” on page 8 for details.
2) Heat pump type: It is impossible to connect the indoor unit for one room only. Be sure to connect at least 2 rooms.
Cooling only type: It is possible to connect the indoor unit for one room only.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Allow 30cm of work
space below the
ceiling surface.
Caulk
pipe hole
gap
with putty.
If there is the danger of the unit falling
or overturning, fix the unit with
foundation bolts, or with wire or other
means.
If the location does not have good
drainage, place the unit on a level
mounting base (or a plastic pedestal).
Install the outdoor unit in a level
position. Failure to do so may result in
water leakage or accumulation.
(Foot bolt-hole centres)
58cm
Level mounting base
(available separately)
25cm from wall
Allow space for piping
and electrical servicing.
Stop valve cover
33cm
(Foot bolt-hole
centres)
Also insulate the connection on the outdoor unit.
Clamping material
Insulation tube
Tape
Service lid
Use tape or insulating material on all connections
to prevent air from getting in between the copper
piping and the insulation tube.
Be sure to do this if the outdoor unit is installed
above.
3■English
Page 6
Installation
▲▲▲■▲■
▲
■
• Install the unit horizontally.
• The unit may be installed directly on a concrete verandah or a solid place if drainage is good.
• If the vibration may possibly be transmitted to the building, use a vibration-proof rubber (field supply).
Connections (connection port)
1.
Install the indoor unit according to the table below, which shows the relationship between the class of indoor unit and the
corresponding port.
The total indoor unit class that can be connected to this unit:
Heat pump type:3MXS68∗ – Up to 11.0kW
4MXS68∗ – Up to 11.0kW
Cooling only type:4MKS75∗ – Up to 13.5kW
Por t
20 , 2520 , 25
A
20,25,3520,25,35
B
###
20,25,3520,25,35,,42
C
####
20,25,35
D
: Use a reducer to connect pipes.
#
: Use No. 2 and 4 reducers
: Use No. 5 and 6 reducers
: Use No. 1 and 3 reducers
Refer to “How to Use Reducers” on page 10 for information on reducer numbers and their shapes.
4MXS68∗4MKS75∗
,42
,35,35
,42
#####
,42
,50
,42
60
20,25,35,42,50,,6060,71,50
42
,42
,50
3MXS68∗
42
,35
20 , 25
####
20,25,35
####
20,25,35,,42
,42
,50
,50
Precautions on Installation
• Check the strength and level of the installation ground so that the unit will not cause any operating vibration or noise after installed.
• In accordance with the foundation drawing in fix the unit securely by means of the foundation bolts. (Prepare four sets of M8 or
M10 foundation bolts, nuts and washers each which are available on the market.)
• It is best to screw in the foundation bolts until their length are 20mm from the foundation surface.
20
■English4
Page 7
Outdoor Unit Installation
Guideline
• Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the installation guidelines below.
• For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.
Wall facing one side
More than 100More than 350
1200
or less
Side view
Walls facing two sides
More than 350
More
than 100
More than 50More than 50
Top view
Walls facing three sides
More than 100
More than 50
More than 350
Top view
Unit: mm
Selecting a Location for Installation of
the Indoor Units
• The maximum allowable length of refrigerant piping, and the maximum allowable height difference between the outdoor and
indoor units, are listed below.
(The shorter the refrigerant piping, the better the performance. Connect so that the piping is as short as possible. Shortest allow-able length per room is 3m.)
Outdoor unit capacity class
Piping to each indoor unit25m max.25m max.
Total length of piping between all units60m max.50m max.
Indoor Unit
Outdoor Unit
Level
difference:
15m max.
Level
difference:
7.5m max.
(Heat pump
unit only)
4MXS68, 4MKS753MXS68
Level
difference:
15m max.
Level
difference:
7.5m max.
(Heat pump
unit only)
Indoor Unit
Outdoor Unit
If the outdoor unit is positioned higher than the
indoor units.
If the outdoor unit is positioned otherwise.
(If lower than one or more indoor units)
5■English
Page 8
Refrigerant Piping Work
Installing outdoor unit
1.
1) When installing the outdoor unit, refer to “Precautions for Selecting the Location” and the “Indoor/Outdoor Unit Installation
Drawings”.
2) If drain work is necessary, follow the procedures below.
Drain work
2.
1) Use drain plug for drainage.
2) If the drain port is covered by a mounting base or floor surface, place
additional foot bases of at least 30mm in height under the outdoor
unit’s feet.
Bottom frame
3) In cold areas, do not use a drain hose with the outdoor unit.
(Otherwise, drain water may freeze, impairing heating performance.)
Hose (available commercially,
inner dia. 16mm)
Refrigerant piping
3.
CAUTION
1) Use the flare nut fixed to the main unit. (To prevent cracking of the flare nut by aged deterioration.)
2) To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.)
3) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage.
Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches.
Drain plug
Drain-water hole
While pressing
[Apply oil][Tighten]
Do not apply refrigeration
oil to the outer surface.
Flare nut
Do not apply refrigeration
oil to the flare nut avoid
tightening with over torque.
Flare nut tightening torque
Flare nut for φ6.4
(144-175kgf • cm)
Flare nut for φ9.5
Flare nut for φ12.7
Flare nut for φ15.9
(333-407kgf • cm)
(505-615kgf • cm)
(630-769kgf • cm)
Apply refrigeration oil to
the inner surface of the
flare.
14.2-17.2N • m
32.7-39.9N • m
49.5-60.3N • m
61.8-75.4N • m
Torque wrench
Spanner
Piping union
Flare nut
Valve cap tightening
torque
Liquid pipe
26.5-32.3N • m
(270-330kgf • cm)
Gas pipe
48.1-59.7N • m
(490-610kgf • cm)
Service port cap
tightening torque
10.8-14.7N • m
(110-150kgf • cm)
■English6
Page 9
Refrigerant Piping Work
Purging air and checking gas leakage
4.
1) When piping work is completed, it is necessary to purge the air and check for gas leakage.
WARNING
1) Do not mix any substance other than the specified refrigerant (R410A) into the refrigeration cycle.
2) When refrigerant gas leaks occur, ventilate the room as soon and as much as possible.
3) R410A, as well as other refrigerants, should always be recovered and never be released directly into the environment.
4) Use a vacuum pump for R410A exclusively. Using the same vacuum pump for different refrigerants may damage the vacuum
pump or the unit.
• If using additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge
additional refrigerant.
• Use a hexagonal wrench (4mm) to operate the stop valve rod.
• All refrigerant pipe joints should be tightened with a torque wrench at the specified tightening torque.
1) Connect projection side of charging hose (which comes from gauge manifold) to gas stop valve’s service port.
2) Fully open gauge manifold’s low-pressure valve (Lo) and completely close its high-pressure valve (Hi).
(High-pressure valve subsequently requires no operation.)
3) Apply vacuum pumping. Check that the compound pressure gauge reads –0.1MPa (–76cmHg).
Evacuation for at least 1 hour is recommended.
4) Close gauge manifold’s low-pressure valve (Lo) and stop vacuum pump.
(Leave as is for 4-5 minutes and make sure the coupling meter needle does not go back.
If it does go back, this may indicate the presence of moisture or leaking from connecting parts. After inspecting all the connection and loosening then retightening the nuts, repeat steps 2-4.)
5) Remove covers from liquid stop valve and gas stop valve.
6) Turn the liquid stop valve’s rod 90 degrees counterclockwise with a hexagonal wrench to open valve.
Close it after 5 seconds, and check for gas leakage.
Using soapy water, check for gas leakage from indoor unit’s flare and outdoor unit’s flare and valve rods.
After the check is complete, wipe all soapy water off.
7) Disconnect charging hose from gas stop valve’s service port, then fully open liquid and gas stop valves.
(Do not attempt to turn valve rod beyond its stop.)
8) Tighten valve caps and service port caps for the liquid and gas stop valves with a torque wrench at the specified torques.
See “3 Refrigerant piping” on page 6 for details.
7■English
Page 10
Refilling the refrigerant
5.
Check the type of refrigerant to be used on the machine nameplate.
Precautions when adding R410A
Fill from the liquid pipe in liquid form.
It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, preventing normal operation.
1) Before filling, check whether the cylinder has a siphon attached or not. (It should have something like “liquid filling siphon
attached” displayed on it.)
Filling a cylinder with an attached siphon
Stand the cylinder upright when filling.
There is a siphon pipe inside, so the
cylinder need not be upside-down to
fill with liquid.
2) Be sure to use the R410A tools to ensure pressure and to prevent foreign objects entering.
Charging with refrigerant
6.
1) If the total length of piping for all rooms exceeds the figure listed below, additionally charge with 20g of refrigerant (R410A)
for each additional meter of piping.
Outdoor capacity class4MXS68, 3MXS68
Total length of piping for all rooms30m
For cooling only
■
• Cooling only models (4MKS75) are chargeless. There is no need to charge with refrigerant.
Filling other cylinders
Turn the cylinder upside-down
when filling.
Important information regarding the refrigerant used
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Do not vent gases into the atmosphere.
Refrigerant type:
(1)
GWP
value:1975
Please fill in with indelible ink,
1
n
the factory refrigerant charge of the product,
2
n
the additional refrigerant amount charged in the field and
1 + 2
n
the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product charging port (e.g. onto the inside of the stop valve
cover).
6
5
R410A
(1)
GWP = global warming potential
1 factory refrigerant charge of the product: see unit name plate
4
2 additional refrigerant amount charged in the field
(Refer to the above information for the quantity of refrigerant
1
replenishment.)
2
3 total refrigerant charge
4 Contains fluorinated greenhouse gases covered by the Kyoto Protocol
5 outdoor unit
3
6 refrigerant cylinder and manifold for charging
CAUTION
Even though the stop valve is fully closed, the refrigerant may slowly leak out; do not leave the flare nut removed for a long
period of time.
■English8
Page 11
Refrigerant Piping Work
Refrigerant piping work
7.
Cautions on pipe handling
1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender for
bending. (Bending radius should be 30 to 40mm or larger.)
Selection of copper and heat insulation materials
When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mh°C)
Refrigerant gas pipe’s surface temperature reaches 110°C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below.
3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.
Flaring the pipe end
8.
1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing downward so that the chips do not enter the pipe.
3) Put the flare nut on the pipe.
4) Flare the pipe.
5) Check that the flaring is properly made.
I.D.: 8–10mm / Thickness: 10mm min.
I.D.: 12–15mm / Thickness: 13mm min.
I.D.: 16–20mm / Thickness: 13mm min.
Set exactly at the position shown below.
Die
A
A0-0.5mm
Be sure to
place a cap.
Rain
(Cut exactly at
right angles.) Remove burrs
Flare tool for R410A
Clutch-type
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.
Gas pipe
Gas pipe
insulation
Flaring
Clutch-type (Rigid-type)
1.0-1.5mm
Finishing tape
Conventional flare tool
Inter-unit wiring
Drain hose
Wing-nut type (Imperial-type)
1.5-2.0mm
Wall
Liquid pipe
Liquid pipe
insulation
Flare’s inner
surface must
be flaw-free.
Check
WARNING
1) Do not use mineral oil on flared part.
2) Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
3) Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
4) Do never install a drier to this R410A unit in order to guarantee its lifetime.
5) The drying material may dissolve and damage the system.
6) Incomplete flaring may cause refrigerant gas leakage.
The pipe end must
be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.
9■English
Page 12
How to Use Reducers
No.1
φ15.9
→ φ12.7
Gasket (1)Gasket (2)Reduce and gasket
Use the reducers supplied with the unit as described below.
1) Connecting a pipe of φ12.7 to a gas pipe connection port for φ15.9:
2) Connecting a pipe of φ9.5 to a gas pipe connection port for φ15.9:
No.2
φ12.7
→ φ9.5
No.3
φ15.9
→ φ12.7
No. 1
Be sure to attach
the gasket.
Connection port
of outdoor unit
No.4
φ12.7
→ φ9.5
No.5
φ15.9
→ φ9.5
No. 3
No.6
φ15.9
→ φ9.5
Inter-unit piping
Flare nut (for φ15.9)
No. 6
Be sure to attach
the gasket.
3) Connecting a pipe of φ9.5 to a gas pipe connection port for φ12.7:
No. 2
Be sure to attach
the gasket.
• When using the reducer packing shown above, be careful not to overtighten the nut, or the smaller pipe may be damaged. (about 2/3 - 1
the normal torque)
• Apply a coat of refrigeration oil to the threaded connection port of the
outdoor unit where the flare nut comes in.
• Use an appropriate wrench to avoid damaging the connection thread
by overtightening the flare nut.
No. 5
No. 4
Flare nut (for φ9.5)
Flare nut (for φ12.7)
Flare nut tightening torque
Flare nut for φ9.5
Flare nut for φ12.7
Flare nut for φ15.9
32.7–39.9N·m
(333–407kgf·cm)
49.5–60.3N·m
(505–615kgf·cm)
61.8–75.4N·m
(630–769kgf·cm)
■English10
Page 13
Pump Down Operation
In order to protect the environment, be sure to pump down when relocating or disposing of the unit.
1) Remove the valve caps from liquid stop valve and gas stop
valve.
2) Carry out forced cooling operation.
3) After five to ten minutes, close the liquid stop valve with a
hexagonal wrench.
4) After two to three minutes, close the gas stop valve and stop
forced cooling operation.
Forced operation
1.
1) Turn the Operation Mode switch (SW2) to “COOL”. (Heat pump only)
2) Press the Forced Operation switch (SW1) to begin forced cooling. Press the Forced Operation switch (SW1) again to stop
forced cooling.
Gas stop valve
Liquid stop valve
Service PC-board
Close
Hexagonal
wrench
Valve caps
Operation Mode
switch (SW2)
Forced Operation
switch (SW1)
11■English
Page 14
Wiring
WARNING
1) Do not use tapped wires, stranded wires, extensioncords, or starburst connections, as they may cause overheating, electrical shock, or
fire.
2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the
terminal block.) Doing so may cause electric shock or fire.
3) Be sure to install an earth leakage breaker. (One that can handle higher harmonics.)
(This unit uses an inverter, which means that it must be used an earth leakage breaker capable handling harmonics in order to
prevent malfunctioning of the earth leakage breaker itself.)
4) Use an all-pole disconnection type breaker with at least 3 mm between the contact point gaps.
• Do not turn ON the safety breaker until all work is completed.
1) Strip the insulation from the wire (20mm).
2) Connect the connection wires between the
indoor and outdoor units so that the terminal numbers match. Tighten the terminal screws
securely. We recommend a flathead screwdriver be used to tighten the screws. The
screws are packed with the terminal board.
Indoor unit
Room A
Room
Room
RoomCRoom
B
A
D
To room D
To room C
H05RN
To room B
Outdoor unit
Be sure to use the dedicated circuits.
Safety breaker
If the length of a connection wire is
10m or more, use φ2.0mm wire.
Earth leakage
circuit breaker
50Hz
220-240V
CAUTION
When connecting the connection wires to the
terminal board using a single core wire, be sure
to perform curling.
Problems with the work may cause heat and fires.
• Ground terminal installation
Use the following method when installing the round
crimp-style terminal.
Screw
Round crimpstyle terminal
Flat washer
GoodWrong
Screw
Flat washer
Round crimpstyle terminal
Shape the wires so that
there is no lifting of the
service hatch or other
structural parts.
Secure the branch wiring firmly using the 4 included screws, as shown in the figure.
Secure firmly, making sure no outside pressure is
exerted on the terminals.
LN
Use the specified wires and
connect them securely.
3) Pull the wire and make sure that it does not disconnect. Then fix the wire in place with a wire stop.
Earth
■
This air conditioner must be earthed.
For earthing, follow the applicable local standard for electrical installations.
■English12
Page 15
Priority Room Setting
• To use priority room setting, initial settings must be made when the unit is installed. Explain the priority room setting, as described
below, to the customer, and confirm whether or not the customer wants to use priority room setting.
Setting it in the guest and living rooms is convenient.
About the priority room setting function
1.
The indoor unit for which priority room setting is applied takes priority in the
following cases.
1-1.
Operation mode priority
The operation mode of the indoor unit which is set for priority room setting
takes priority. If the set indoor unit is operating, all other indoor units do not
operate and enter standby mode, according to the operation mode of the set
indoor unit.
1-2.
Priority during high-power operation
If the indoor unit which is set for priority room setting is operating at high
power, the capabilities of other indoor units will be somewhat reduced.
Power supply gives priority to the indoor unit which is set for priority room
setting.
1-3.
Quiet operation priority
Setting the indoor unit to quiet operation will make the outdoor unit
run quietly.
Service PC-board
Priority Room
Setting switch (SW4)
Setting procedure
Slide the switch to the ON side for the switch that corresponds to the piping connected to the indoor unit to be set. (In the figure below, it is room A.)
Once the settings are complete, reset the power.
Be sure to only set one room
13■English
Page 16
Night Quiet Mode Setting
• If night quiet mode is to be used, initial settings must be made when the unit is
installed.
Explain night quiet mode, as described below, to the customer, and confirm
whether or not the customer wants to use
night quiet mode.
About night quiet mode
The night quiet mode function reduces operating noise of the outdoor unit at nighttime. This function is useful if the customer is worried about the effects of the operating noise on the neighbors.
However, if night quiet mode is running, cooling/heating capacity will be saved.
Setting procedure
Remove the SW5 jumper switch.
Once the settings are complete, reset the power.
NOTE:
Install the removed jumper switch as described below. This switch will be needed
to later disable this setting.
Service PC-board
Night Quiet Mode
setting switch (SW5)
Jumper switchAfter removing
COOL/ HEAT Mode Lock <S15>
(Heat Pump Units Only)
• Use the S15 connector to set the unit to only cool or heat.
Setting to only heat (H): short-circuit pins 1 and 3 of the connector <S15>
Setting to only cool (C): short-circuit pins 3 and 5 of the connector <S15>
The following specifications apply to the connector housing and pins.
JST productsHousing:VHR-5N
Pin:SVH-21T-1,1
Note that forced operation is also possible in COOL/HEAT mode.
HEAT mode (H)
1 3 5
Arrow view
COOL mode (C)
5#
5
5
5
PCB
5
5 !
■English14
Page 17
Test Run and Final Check
• Before starting the test run, measure the voltage at the primary side of the safety breaker. Check that it is 220-240V.
• Check that all liquid and gas stop valves are fully open.
• Check that piping and wiring all match. The wiring error check can be conveniently used for underground wiring and other wiring
that cannot be directly checked.
Wiring error check
1.
• This product is capable of automatic correction of wiring error.
• Press the “wiring error check switch” on the outdoor unit service monitor
print board. However, the wiring error check switch will not function for
one minute after the safety breaker is turned on, or depending on the
outside air conditions (See NOTE 2.). Approximately 10–15 minutes
after the switch is pressed, the errors in the connection wiring will be
corrected.
The service monitor LEDs indicate whether or not correction is
possible, as shown in the table below. For details about how to read the
LED display, refer to the service guide.
If self-correction is not possible, check the indoor unit wiring and piping
in the usual manner.
LED
1234
Message
All FlashingAutomatic correction impossible
Status
Flashing One after another
(One or more of LEDs 1 to 4 are ON)
Automatic correction completed
Abnormal stop [NOTE. 4]
Wiring correct example
Service PC-board
Wiring error
check switch
(SW3)
Terminal block
∗ The figure at left shows branch wiring.
From Room C
to the “kitchen”
From Room B
to the “living room”
LED lighting sequence after a wiring correction.
Order of LED flashing: 2 ➝ 1 ➝ 3 ➝ 4
From Room D
to the “children’s room”
Wiring error check
From Room A
to the “bedroom”
NOTE:
1) For two rooms, LED 3 and 4 are not displayed, and for three rooms, LED 4 is not displayed.
2) If the outside air temperature is 5°C or less , the wiring error check function will not operate.
3) After wiring error check operation is completed, LED indication will continue until ordinary operation starts.
This is normal.
4) Follow the product diagnosis procedures. (Check the nameplate on the underside of the stop valve.)
15■English
Page 18
Test run and final check
2.
1) To test cooling, set for the lowest temperature. To test heating, set for the highest temperature. (Depending on the room
temperature, only heating or cooling (but not both) may be possible.)
2) After the unit is stopped, it will not start again (heating or cooling) for approximately 3 minutes.
3) During the test run, first check the operation of each unit individually. Then also check the simultaneous operation of
all indoor units.
Check both heating and cooling operation.
4) After running the unit for approximately 20 minutes, measure the temperatures at the indoor unit inlet and outlet. If the
measurements are above the values shown in the table below, then they are normal.
CoolingHeating
Temperature difference
between inlet and outlet
5) During cooling operation, frost may form on the gas stop valve or other parts. This is normal.
6) Operate the indoor units in accordance with the included operation manual. Check that they operate normally.
Items to check
3.
Check itemConsequences of troubleCheck
Are the indoor units installed securely?Falling, vibration, noise
Has an inspection been made to check for gas leakage?No cooling, no heating
Has complete thermal insulation been done (gas pipes, liquid
pipes, indoor portions of the drain hose extension)?
Is the drainage secure?Water leakage
Are the ground wire connections secure?Danger in the event of a ground fault
Are the electric wires connected correctly?No cooling, no heating
Is the wiring in accordance with the specifications?Operation failure, burning
Are the inlets/outlets of the indoor and outdoor units free of any
obstructions? Are the stop valves open?
Do the marks match (room A, room B) on the wiring and piping
for each indoor unit?
Is the priority room setting set for 2 or more rooms?
Approx. 8°CApprox. 20°C
(When running in one room)
Water leakage
No cooling, no heating
No cooling, no heating
The priority room setting will not function.
ATTENTION
■
1) Have the customer actually operate the unit while looking at the manual included with the indoor unit. Instruct the customer
how to operate the unit correctly (particularly cleaning of the air filters, operation procedures, and temperature adjustment).
2) Even when the air conditioner is not operating, it consumes some electric power. If the customer is not going to use the unit
soon after it is installed, turn OFF the breaker to avoid wasting electricity.
3) If additional refrigerant has been charged because of long piping, list the amount added on the nameplate on the reverse side
of the stop valve cover.
■English16
Page 19
Two-dimensional bar code is a code
for manufacturing.
3P192068-1D M06B150C
(0710) HT
Loading...