Service
Manual
SiUS121502E
2/3/4MXS-N Series
[Applied Models]
z Inverter Multi : Heat Pump
Multi-Split Type
Air Conditioners
2/3/4MXS-N Series
z Heat Pump
Indoor Unit
CTXS07LVJU FDXS09LVJU FVXS09NVJU FFQ09LVJU
FTXS09LVJU FDXS12LVJU FVXS12NVJU FFQ12LVJU
FTXS12LVJU CDXS15LVJU FVXS18NVJU FFQ15LVJU
FTXS15LVJU CDXS18LVJU FFQ18LVJU
FTXS18LVJU CDXS24LVJU
FTXS24LVJU
SiUS121502E
Outdoor Unit
2MXS18NMVJU
3MXS24NMVJU
4MXS36NMVJU
i Table of Contents
SiUS121502E
1. Safety Cautions.......................................................................................... vi
1.1 Warnings and Cautions Regarding Safety of Workers .................................vi
1.2 Warnings and Cautions Regarding Safety of Users................................... viii
2. Used Icons ................................................................................................. xi
Part 1 List of Functions ................................................................... 1
1. Functions.....................................................................................................2
Part 2 Specifications ....................................................................... 7
1. Indoor Unit...................................................................................................8
2. Outdoor Unit..............................................................................................14
Part 3 Printed Circuit Board Connector Wiring Diagram ..............17
1. Indoor Unit.................................................................................................18
1.1 CTXS07LVJU, FTXS09/12LVJU ................................................................ 18
1.2 FTXS15/18/24LVJU ................................................................................... 20
1.3 FDXS09/12LVJU, CDXS15/18/24LVJU ..................................................... 22
1.4 FVXS09/12/18NVJU................................................................................... 24
1.5 FFQ09/12/15/18LVJU ................................................................................ 26
2. Wired Remote Controller...........................................................................27
2.1 BRC1E71 ................................................................................................... 27
2.2 BRC1E72/73 .............................................................................................. 28
3. Wireless Remote Controller ......................................................................29
3.1 BRC7E830 ................................................................................................. 29
4. Outdoor Unit..............................................................................................30
Part 4 Function and Control...........................................................33
1. Function of CTXS, FTXS, CDXS, FDXS, FVXS Series ............................34
1.1 Temperature Control .................................................................................. 34
1.2 Frequency Principle.................................................................................... 34
1.3 Airflow Direction Control (CTXS, FTXS, FVXS Series) .............................. 36
1.4 Fan Speed Control for Indoor Unit ............................................................. 39
1.5 Program Dry Operation .............................................................................. 40
1.6 Automatic Operation................................................................................... 41
1.7 Thermostat Control..................................................................................... 42
1.8 NIGHT SET Mode ...................................................................................... 43
1.9 ECONO Operation ..................................................................................... 43
1.10 INTELLIGENT EYE Operation (CTXS, FTXS Series) ................................ 44
1.11 Inverter POWERFUL Operation ................................................................. 45
1.12 Clock Setting .............................................................................................. 46
1.13 WEEKLY TIMER Operation (CTXS, FTXS, FVXS series) ......................... 47
1.14 Other Functions.......................................................................................... 53
2. Function of FFQ Series.............................................................................54
2.1 Drain Pump Control .................................................................................... 54
2.2 Thermostat Sensor in Remote Controller................................................... 56
Table of Contents ii
SiUS121502E
2.3 Freeze Prevention Control ......................................................................... 58
2.4 Hot Start Control (In Heating Operation Only)............................................ 59
3. Control Specification .................................................................................60
3.1 Function of Thermistor ............................................................................... 60
3.2 Mode Hierarchy .......................................................................................... 62
3.3 Frequency Control ...................................................................................... 63
3.4 Controls at Mode Changing / Start-up........................................................ 65
3.5 Discharge Pipe Temperature Control......................................................... 66
3.6 Input Current Control .................................................................................. 67
3.7 Freeze-up Protection Control ..................................................................... 68
3.8 Heating Peak-cut Control ........................................................................... 68
3.9 Outdoor Fan Control................................................................................... 69
3.10 Liquid Compression Protection Function.................................................... 69
3.11 Defrost Control ........................................................................................... 70
3.12 Low Hz High Pressure Limit ....................................................................... 71
3.13 Electronic Expansion Valve Control ........................................................... 72
3.14 Malfunctions ............................................................................................... 77
Part 5 Remote Controller ...............................................................78
1. CTXS, FTXS Series ..................................................................................79
2. CDXS, FDXS Series .................................................................................81
3. FVXS Series..............................................................................................83
4. FFQ Series................................................................................................85
4.1 <BRC1E71> Wired Remote Controller....................................................... 85
4.2 <BRC1E72/73> Wired Remote Controller.................................................. 90
4.3 <BRC7E830> Wireless Remote Controller ................................................ 96
Part 6 Service Diagnosis................................................................ 97
1. General Problem Symptoms and Check Items .........................................99
2. Troubleshooting with LED .......................................................................100
2.1 Indoor Unit................................................................................................ 100
2.2 Outdoor Unit ............................................................................................. 101
3. Service Diagnosis ...................................................................................102
3.1 CTXS, FTXS, CDXS, FDXS, FVXS Series .............................................. 102
3.2 FFQ Series ............................................................................................... 108
4. Code Indication on Remote Controller....................................................114
4.1 CTXS, FTXS, CDXS, FDXS, FVXS Series .............................................. 114
4.2 FFQ Series ............................................................................................... 114
4.3 Outdoor Unit ............................................................................................. 115
5. Troubleshooting for CTXS, FTXS, CDXS, FDXS, FVXS Series ............. 116
5.1 Indoor Unit PCB Abnormality ................................................................... 116
5.2 Freeze-up Protection Control / Heating Peak-cut Control ........................ 118
5.3 Fan Motor or Related Abnormality ........................................................... 119
5.4 Thermistor or Related Abnormality........................................................... 123
5.5 Signal Transmission Error (Between Indoor Unit and Outdoor Unit)........ 124
5.6 Unspecified Voltage (Between Indoor Unit and Outdoor Unit) ................. 126
iii Table of Contents
SiUS121502E
6. Troubleshooting for FFQ Series..............................................................127
6.1 Indoor Unit PCB Abnormality ................................................................... 127
6.2 Drain Level Control System Abnormality.................................................. 128
6.3 Fan Motor (AC Motor) or Related Abnormality ......................................... 129
6.4 Drain System Abnormality........................................................................ 130
6.5 Thermistor or Related Abnormality........................................................... 131
6.6 Remote Controller Thermistor Abnormality .............................................. 132
6.7 Signal Transmission Error
(Between Indoor Unit and Remote Controller) ......................................... 133
6.8 Signal Transmission Error
(Between MAIN Remote Controller and SUB Remote Controller) ........... 134
6.9 Field Setting Abnormality ......................................................................... 135
7. Troubleshooting for Outdoor Unit............................................................136
7.1 Refrigerant Shortage ................................................................................ 136
7.2 Low-voltage Detection or Over-voltage Detection.................................... 138
7.3 Wiring Error Check Unexecuted ............................................................... 140
7.4 Unspecified Voltage (Between Indoor Unit and Outdoor Unit) /
Anti-icing Control in Other Rooms............................................................ 141
7.5 Anti-icing Control for Indoor Unit .............................................................. 142
7.6 Outdoor Unit PCB Abnormality................................................................. 144
7.7 OL Activation (Compressor Overload) ..................................................... 145
7.8 Compressor Lock ..................................................................................... 147
7.9 DC Fan Lock ............................................................................................ 148
7.10 Input Overcurrent Detection ..................................................................... 149
7.11 Four Way Valve Abnormality.................................................................... 150
7.12 Discharge Pipe Temperature Control....................................................... 152
7.13 High Pressure Control in Cooling ............................................................. 153
7.14 Compressor Sensor System Abnormality ................................................ 154
7.15 Position Sensor Abnormality .................................................................... 156
7.16 CT or Related Abnormality ....................................................................... 158
7.17 Thermistor or Related Abnormality (Outdoor Unit) ................................... 160
7.18 Electrical Box Temperature Rise .............................................................. 162
7.19 Radiation Fin Temperature Rise .............................................................. 163
7.20 Output Overcurrent Detection .................................................................. 164
8. Check ......................................................................................................166
8.1 Thermistor Resistance Check .................................................................. 166
8.2 Indoor Fan Motor Connector Check ......................................................... 167
8.3 Hall IC Check ........................................................................................... 167
8.4 Power Supply Waveform Check............................................................... 168
8.5 Electronic Expansion Valve Check........................................................... 169
8.6 Four Way Valve Performance Check ....................................................... 170
8.7 Inverter Unit Refrigerant System Check................................................... 170
8.8 Inverter Analyzer Check ........................................................................... 171
8.9 Rotation Pulse Check on the Outdoor Unit PCB ...................................... 172
8.10 Installation Condition Check ..................................................................... 173
8.11 Discharge Pressure Check....................................................................... 173
8.12 Outdoor Fan System Check ..................................................................... 174
8.13 Main Circuit Short Check.......................................................................... 174
8.14 Capacitor Voltage Check.......................................................................... 175
Table of Contents iv
SiUS121502E
8.15 Power Module Check ............................................................................... 176
Part 7 Trial Operation and Field Settings.................................... 177
1. Pump Down Operation............................................................................178
2. Wiring Error Check Function...................................................................179
3. Trial Operation ........................................................................................181
3.1 CTXS, FTXS, CDXS, FDXS, FVXS Series .............................................. 181
3.2 FFQ Series ............................................................................................... 183
4. Field Settings ..........................................................................................185
4.1 Outdoor Unit ............................................................................................. 185
4.2 CTXS, FTXS, CDXS, FDXS, FVXS Series .............................................. 187
4.3 FFQ Series ............................................................................................... 192
5. Silicon Grease on Power Transistor / Diode Bridge................................199
Part 8 Appendix............................................................................200
1. Piping Diagrams......................................................................................201
1.1 Indoor Unit................................................................................................ 201
1.2 Outdoor Unit ............................................................................................. 204
2. Wiring Diagrams......................................................................................206
2.1 Indoor Unit................................................................................................ 206
2.2 Outdoor Unit ............................................................................................. 211
v Table of Contents
SiUS121502E Safety Cautions
1. Safety Cautions
Be sure to read the following safety cautions before conducting repair work.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment
operates normally, and explain the cautions for operating the product to the customer.
Caution Items The caution items are classified into Warning and Caution . The Warning items are
especially important since they can lead to death or serious injury if they are not followed closely.
The Caution items can also lead to serious accidents under some conditions if they are not
followed. Therefore, be sure to observe all the safety caution items described below.
Pictograms This symbol indicates the item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates the prohibited action.
The prohibited item or action is shown in the illustration or near the symbol.
This symbol indicates the action that must be taken, or the instruction.
The instruction is shown in the illustration or near the symbol.
1.1 Warnings and Cautions Regarding Safety of Workers
Warning
Do not store the equipment in a room with successive fire sources (e.g.,
naked flame, gas appliance, electric heater).
Be sure to disconnect the power cable plug from the plug socket before
disassembling the equipment for repair.
Working on the equipment that is connected to the power supply may cause an
electrical shock.
If it is necessary to supply power to the equipment to conduct the repair or
inspecting the circuits, do not touch any electrically charged sections of the
equipment.
If the refrigerant gas is discharged during the repair work, do not touch
the discharged refrigerant gas.
The refrigerant gas may cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at
the welded section, evacuate the refrigerant gas completely at a wellventilated place first.
If there is gas remaining inside the compressor, the refrigerant gas or
refrigerating machine oil discharges when the pipe is disconnected, and it may
cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area.
The refrigerant gas may generate toxic gases when it contacts flames.
Be sure to discharge the capacitor completely before conducting repair
work.
The step-up capacitor supplies high-voltage electricity to the electrical
components of the outdoor unit.
A charged capacitor may cause an electrical shock.
vi
Safety Cautions SiUS121502E
Warning
Do not start or stop the air conditioner operation by plugging or
unplugging the power cable plug.
Plugging or unplugging the power cable plug to operate the equipment may
cause an electrical shock or fire.
Be sure to wear a safety helmet, gloves, and a safety belt when working
at a high place (more than 2 m (6.5 ft)).
Insufficient safety measures may cause a fall accident.
In case of R-32 / R-410A refrigerant models, be sure to use pipes, flare
nuts and tools for the exclusive use of the R-32 / R-410A refrigerant.
The use of materials for R-22 refrigerant models may cause a serious accident
such as a damage of refrigerant cycle as well as an equipment failure.
Do not mix air or gas other than the specified refrigerant (R-32 / R-410A /
R-22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results,
causing equipment damage and injury.
Caution
Do not repair the electrical components with wet hands.
Working on the equipment with wet hands may cause an electrical shock.
Do not clean the air conditioner by splashing water.
Washing the unit with water may cause an electrical shock.
Be sure to provide the earth / grounding when repairing the equipment in
a humid or wet place, to avoid electrical shocks.
Be sure to turn off the power switch and unplug the power cable when
cleaning the equipment.
The internal fan rotates at a high speed, and may cause injury.
Be sure to conduct repair work with appropriate tools.
The use of inappropriate tools may cause injury.
vii
SiUS121502E Safety Cautions
Caution
Be sure to check that the refrigerating cycle section has cooled down
enough before conducting repair work.
Working on the unit when the refrigerating cycle section is hot may cause
burns.
Use the welder in a well-ventilated place.
Using the welder in an enclosed room may cause oxygen deficiency.
1.2 Warnings and Cautions Regarding Safety of Users
Warning
Do not store the equipment in a room with successive fire sources (e.g.,
naked flame, gas appliance, electric heater).
Be sure to use parts listed in the service parts list of the applicable model
and appropriate tools to conduct repair work. Never attempt to modify the
equipment.
The use of inappropriate parts or tools may cause an electrical shock,
excessive heat generation or fire.
If the power cable and lead wires have scratches or deteriorated, be sure
to replace them.
Damaged cable and wires may cause an electrical shock, excessive heat
generation or fire.
Do not use a joined power cable or extension cable, or share the same
power outlet with other electrical appliances, since it may cause an
electrical shock, excessive heat generation or fire.
Be sure to use an exclusive power circuit for the equipment, and follow
the local technical standards related to the electrical equipment, the
internal wiring regulations, and the instruction manual for installation
when conducting electrical work.
Insufficient power circuit capacity and improper electrical work may cause an
electrical shock or fire.
Be sure to use the specified cable for wiring between the indoor and
outdoor units.
Make the connections securely and route the cable properly so that there is no
force pulling the cable at the connection terminals.
Improper connections may cause excessive heat generation or fire.
viii
Safety Cautions SiUS121502E
Warning
When wiring between the indoor and outdoor units, make sure that the
terminal cover does not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section may cause
an electrical shock, excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cable may cause an electrical shock or fire.
Placing heavy items on the power cable, and heating or pulling the power cable
may damage the cable.
Do not mix air or gas other than the specified refrigerant (R-32 / R-410A /
R-22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results,
causing equipment damage and injury.
If the refrigerant gas leaks, be sure to locate the leaking point and repair
it before charging the refrigerant. After charging refrigerant, make sure
that there is no refrigerant leak.
If the leaking point cannot be located and the repair work must be stopped, be
sure to perform pump-down and close the service valve, to prevent the
refrigerant gas from leaking into the room. The refrigerant gas itself is
harmless, but it may generate toxic gases when it contacts flames, such as fan
and other heaters, stoves and ranges.
When relocating the equipment, make sure that the new installation site
has sufficient strength to withstand the weight of the equipment.
If the installation site does not have sufficient strength and if the installation
work is not conducted securely, the equipment may fall and cause injury.
Check to make sure that the power cable plug is not dirty or loose, then
insert the plug into a power outlet securely.
If the plug has dust or loose connection, it may cause an electrical shock or fire.
Be sure to install the product correctly by using the provided standard
installation frame.
Incorrect use of the installation frame and improper installation may cause the
equipment to fall, resulting in injury.
Be sure to install the product securely in the installation frame mounted
on the window frame.
If the unit is not securely mounted, it may fall and cause injury.
When replacing the coin battery in the remote controller, be sure to
dispose of the old battery to prevent children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
For unitary type
only
For unitary type
only
ix
SiUS121502E Safety Cautions
Caution
Installation of a leakage breaker is necessary in some cases depending
on the conditions of the installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of
combustible gas leaks.
If the combustible gas leaks and remains around the unit, it may cause a fire.
Check to see if the parts and wires are mounted and connected properly,
and if the connections at the soldered or crimped terminals are secure.
Improper installation and connections may cause excessive heat generation,
fire or an electrical shock.
If the installation platform or frame has corroded, replace it.
Corroded installation platform or frame may cause the unit to fall, resulting in
injury.
Check the earth / grounding, and repair it if the equipment is not properly
earthed / grounded.
Improper earth / grounding may cause an electrical shock.
Be sure to measure the insulation resistance after the repair, and make
sure that the resistance is 1 MΩ or higher.
Faulty insulation may cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage may cause the water to enter the room and wet the furniture
and floor.
Do not tilt the unit when removing it.
The water inside the unit may spill and wet the furniture and floor.
Be sure to install the packing and seal on the installation frame properly.
If the packing and seal are not installed properly, water may enter the room and
wet the furniture and floor.
For unitary type
only
x
Used Icons SiUS121502E
2. Used Icons
The following icons are used to attract the attention of the reader to specific information.
Icon Type of
Information
Warning A Warning is used when there is danger of personal injury.
Warning
Caution A Caution is used when there is danger that the reader, through
Caution
Note A Note provides information that is not indispensable, but may
Note:
Reference A Reference guides the reader to other places in this binder or
Description
incorrect manipulation, may damage equipment, lose data, get
an unexpected result or has to restart (part of) a procedure.
nevertheless be valuable to the reader, such as tips and tricks.
in this manual, where he/she will find additional information on a
specific topic.
xi
SiUS121502E
Part 1
List of Functions
1. Functions.....................................................................................................2
List of Functions 1
Functions SiUS121502E
1. Functions
Category Functions
CTXS07LVJU
Basic
Function
Compressor Oval scroll compressor — — Longlife filter (option) — —
Comfortable
Airflow
Comfort
Control
Operation Automatic operation
Lifestyle
Convenience
Inverter (with inverter power control)
Operation limit for cooling (°CDB) — — Photocatalytic deodorizing filter — —
Operation limit for cooling (°FDB) — —
Operation limit for heating (°CWB) — —
Operation limit for heating (°FWB) — —
PAM control — —
Swing compressor — — Air filter (prefilter)
Rotary compressor — — Wipe-clean flat panel
Reluctance DC motor — — Washable grille — —
Power-airflow flap (horizontal blade) — — Filter cleaning indicator — —
Power-airflow dual flaps
Power-airflow diffuser — — Timer WEEKLY TIMER operation
Wide-angle louvers (vertical blades)
Auto-swing (up and down)
Auto-swing (right and left)
3-D airflow
COMFORT AIRFLOW operation
Auto fan speed
Indoor unit quiet operation
NIGHT QUIET mode (automatic) — — Flexibility Multi-split / split type compatible indoor
OUTDOOR UNIT QUIET operation
(manual)
INTELLIGENT EYE operation
Quick warming function — — Chargeless — —
Hot-start function
Automatic defrosting — — Power selection — —
Program dry function
Fan only
New POWERFUL operation
(non-inverter)
Inverter POWERFUL operation
Priority-room setting — —
COOL / HEAT mode lock — — DIII-NET compatible (adaptor) (option)
HOME LEAVE operation — — Remote
ECONO operation
Indoor unit ON/OFF button
Signal receiving sign
R/C with back light
Temperature display — —
Note:
: Available
z
zz
zz
zz
zz
zz
zz
zz
zz
zz
zz
zz
zz
zz
zz
zz
——
zz
zz
zz
zz
zz
Category Functions
FTXS09/12/15/18/24LVJU
Health &
Clean
Worry Free
(Reliability &
Durability)
Remote
Control
Controller
Air-purifying filter — —
Air-purifying filter with photocatalytic
deodorizing function
Titanium apatite photocatalytic
air-purifying filter
Good-sleep cooling operation — —
24-hour ON/OFF TIMER
NIGHT SET mode
Auto-restart (after power failure)
Self-diagnosis (R/C, LED)
Wiring error check function — —
Anti-corrosion treatment of outdoor heat
exchanger
unit
Flexible power supply correspondence — —
High ceiling application — —
Either side drain (right or left)
°F/°C changeover R/C temperature
display (factory setting: °F)
5-room centralized controller (option)
Remote control adaptor
(normal open pulse contact) (option)
Remote control adaptor
(normal open contact) (option)
Wireless
Wired (option)
CTXS07LVJU
——
zz
zz
zz
zz
zz
zz
zz
zz
——
—
zz
zz
zz
zz
zz
zz
zz
zz
— : Not available
FTXS09/12/15/18/24LVJU
z
2 List of Functions
SiUS121502E Functions
Category Functions
FDXS09/12LVJU
Basic
Function
Compressor Oval scroll compressor — — Longlife filter (option) — —
Comfortable
Airflow
Comfort
Control
Operation Automatic operation
Lifestyle
Convenience
Inverter (with inverter power control) zzHealth &
Operation limit for cooling (°CDB) — — Photocatalytic deodorizing filter — —
Operation limit for cooling (°FDB) — —
Operation limit for heating (°CWB) — —
Operation limit for heating (°FWB) — —
PAM control — —
Swing compressor — — Air filter (prefilter)
Rotary compressor — — Wipe-clean flat panel — —
Reluctance DC motor — — Washable grille — —
Power-airflow flap (horizontal blade) — — Filter cleaning indicator — —
Power-airflow dual flaps — — Good-sleep cooling operation — —
Power-airflow diffuser — — Timer WEEKLY TIMER operation — —
Wide-angle louvers (vertical blades) — — 24-hour ON/OFF TIMER
Auto-swing (up and down) — — NIGHT SET mode
Auto-swing (right and left) — — Worry Free
3-D airflow — — Self-diagnosis (R/C, LED)
COMFORT AIRFLOW operation — — Wiring error check function — —
Auto fan speed
Indoor unit quiet operation
NIGHT QUIET mode (automatic) — — Flexibility Multi-split / split type compatible indoor
OUTDOOR UNIT QUIET operation
(manual)
INTELLIGENT EYE operation — — High ceiling application — —
Quick warming function — — Chargeless — —
Hot-start function
Automatic defrosting — — Power selection — —
Program dry function
Fan only
New POWERFUL operation
(non-inverter)
Inverter POWERFUL operation
Priority-room setting — —
COOL / HEAT mode lock — — DIII-NET compatible (adaptor) (option)
HOME LEAVE operation — — Remote
ECONO operation
Indoor unit ON/OFF button
Signal receiving sign
R/C with back light
Temperature display — —
Note:
: Available
z
zz
zz
zz
zz
zz
zz
zz
——
zz
zz
zz
zz
zz
Category Functions
CDXS15/18/24LVJU
Clean
(Reliability &
Durability)
Remote
Control
Controller
Air-purifying filter — —
Air-purifying filter with photocatalytic
deodorizing function
Titanium apatite photocatalytic
air-purifying filter
Auto-restart (after power failure)
Anti-corrosion treatment of outdoor heat
exchanger
unit
Flexible power supply correspondence — —
Either side drain (right or left) — —
°F/°C changeover R/C temperature
display (factory setting: °F)
5-room centralized controller (option)
Remote control adaptor
(normal open pulse contact) (option)
Remote control adaptor
(normal open contact) (option)
Wireless (option)
Wired (option)
FDXS09/12LVJU
——
——
zz
zz
zz
zz
zz
——
—
z
zz
zz
zz
zz
zz
zz
zz
— : Not available
CDXS15/18/24LVJU
List of Functions 3
Functions SiUS121502E
Category Functions
Basic
Function
Compressor Oval scroll compressor — Longlife filter (option) —
Comfortable
Airflow
Comfort
Control
Operation Automatic operation
Lifestyle
Convenience
Inverter (with inverter power control) z Health &
Operation limit for cooling (°CDB) — Photocatalytic deodorizing filter —
Operation limit for cooling (°FDB) —
Operation limit for heating (°CWB) —
Operation limit for heating (°FWB) —
PAM control —
Swing compressor — Air filter (prefilter)
Rotary compressor — Wipe-clean flat panel
Reluctance DC motor — Washable grille —
Power-airflow flap (horizontal blade) — Filter cleaning indicator —
Power-airflow dual flaps — Good-sleep cooling operation —
Power-airflow diffuser — Timer WEEKLY TIMER operation
Wide-angle louvers (vertical blades)
Auto-swing (up and down)
Auto-swing (right and left) — Worry Free
3-D airflow — Self-diagnosis (R/C, LED)
COMFORT AIRFLOW operation — Wiring error check function —
Auto fan speed
Indoor unit quiet operation
NIGHT QUIET mode (automatic) — Flexibility Multi-split / split type compatible indoor unit —
OUTDOOR UNIT QUIET operation (manual)
INTELLIGENT EYE operation — High ceiling application —
Quick warming function — Chargeless —
Hot-start function
Automatic defrosting — Power selection —
Program dry function
Fan only
New POWERFUL operation
(non-inverter)
Inverter POWERFUL operation
Priority-room setting —
COOL / HEAT mode lock — DIII-NET compatible (adaptor) (option)
HOME LEAVE operation — Remote
ECONO operation
Indoor unit ON/OFF button
Signal receiving sign
R/C with back light
Temperature display —
Note:
: Available
z
Category Functions
FVXS09/12/18NVJU
Air-purifying filter —
Air-purifying filter with photocatalytic
deodorizing function
Titanium apatite photocatalytic
air-purifying filter
24-hour ON/OFF TIMER
NIGHT SET mode
Auto-restart (after power failure)
Anti-corrosion treatment of outdoor heat
exchanger
Flexible power supply correspondence —
Either side drain (right or left) —
°F/°C changeover R/C temperature display
(factory setting: °F)
5-room centralized controller (option)
Remote control adaptor
(normal open pulse contact) (option)
Remote control adaptor
(normal open contact) (option)
Wireless
Wired (option) —
z
z
z
z
z
z
z
z
z
—
z
z
z
z
z
Clean
(Reliability &
Durability)
Remote
Control
Controller
—
—
— : Not available
FVXS09/12/18NVJU
z
z
z
z
z
z
z
z
z
z
z
z
z
z
4 List of Functions
SiUS121502E Functions
Category Functions
Basic
Function
Compressor Oval scroll compressor — Longlife filter (option)
Comfortable
Airflow
Comfort
Control
Operation Automatic operation
Lifestyle
Convenience
Inverter (with inverter power control)
Operation limit for cooling (°CDB) — Photocatalytic deodorizing filter —
Operation limit for cooling (°FDB) —
Operation limit for heating (°CWB) —
Operation limit for heating (°FWB) —
PAM control —
Swing compressor — Air filter (prefilter) —
Rotary compressor — Wipe-clean flat panel —
Reluctance DC motor — Washable grille
Power-airflow flap (horizontal blade) — Filter cleaning indicator
Power-airflow dual flaps — Good-sleep cooling operation —
Power-airflow diffuser — Timer WEEKLY TIMER operation
Wide-angle louvers (vertical blades) — 24-hour ON/OFF TIMER —
Auto-swing (up and down)
Auto-swing (right and left) — NIGHT SET mode —
3-D airflow — Worry Free
COMFORT AIRFLOW operation — Self-diagnosis (R/C, LED)
Auto fan speed — Wiring error check function —
Indoor unit quiet operation —
NIGHT QUIET mode (automatic) —
OUTDOOR UNIT QUIET operation (manual) — Flexibility Multi-split / split type compatible indoor unit —
INTELLIGENT EYE operation — Flexible power supply correspondence —
Quick warming function — High ceiling application —
Hot-start function
Automatic defrosting — Either side drain (right or left) —
Program dry function
Fan only
New POWERFUL operation
(non-inverter)
Inverter POWERFUL operation —
Priority-room setting —
COOL / HEAT mode lock —
HOME LEAVE operation — DIII-NET compatible (adaptor) (option)
ECONO operation — Remote
Indoor unit ON/OFF button
Signal receiving sign
R/C with back light
Temperature display —
Note:
: Available
z
z
z
z
— : Not available
Category Functions
FFQ09/12/15/18LVJU
Health &
z
Clean
z
(Reliability &
Durability)
z
z
z
z
Remote
—
Control
Controller
1 Wired (option)
1
2
Air-purifying filter —
Air-purifying filter with photocatalytic
deodorizing function
Titanium apatite photocatalytic
air-purifying filter
72-hour ON/OFF TIMER
Auto-restart (after power failure)
Anti-corrosion treatment of outdoor heat
exchanger
Chargeless —
Power selection —
°F/°C changeover R/C temperature display
(factory setting: °F)
5-room centralized controller (option) —
Remote control adaptor
(normal open pulse contact) (option)
Remote control adaptor
(normal open contact) (option)
Wireless (option)
1: With wireless remote controller
2: With wired remote controller
z
z
z
FFQ09/12/15/18LVJU
—
—
z
z
z
2
1
z
z
—
2
—
—
z
z
z
List of Functions 5
Functions SiUS121502E
Category Functions
2MXS18NMVJU
Basic Function Inverter (with inverter power control)
Operation limit for cooling (°CDB)
Operation limit for cooling (°FDB)
Operation limit for heating (°CWB)
Operation limit for heating (°FWB)
PAM control
Compressor Oval scroll compressor — — Washable grille — —
Swing compressor
Rotary compressor — — Good-sleep cooling operation — —
Reluctance DC motor
Comfortable
Airflow
Comfort
Control
Operation Automatic operation — — Remote
Lifestyle
Convenience
Power-airflow flap (horizontal blade) — — 24-hour ON/OFF timer — —
Power-airflow dual flaps — — NIGHT SET mode — —
Power-airflow diffuser — — Worry Free
Wide-angle louvers (vertical blades) — — Self-diagnosis (R/C, LED)
Auto-swing (up and down) — — Wiring error check function
Auto-swing (right and left) — —
3-D airflow — —
COMFORT AIRFLOW operation — — Flexibility
Auto fan speed — —
Indoor unit quiet operation — — Flexible power supply correspondence — —
NIGHT QUIET mode (automatic)
OUTDOOR UNIT QUIET operation
(manual)
INTELLIGENT EYE operation — — Either side drain (right or left) — —
Quick warming function
Hot-start function — —
Automatic defrosting
Program dry function — —
Fan only — —
New POWERFUL operation
(non-inverter)
Inverter POWERFUL operation — — DIII-NET compatible (adaptor) (option) — —
Priority-room setting
COOL / HEAT mode lock
HOME LEAVE operation — —
ECONO operation — —
Indoor unit ON/OFF button — —
Signal receiving sign — —
R/C with back light — —
Temperature display — —
Note:
: Available
z
zz
–10
–10
~ 46
~ 46
14 ~
14 ~
114.8
114.8
–15 ~
–15 ~
15.5
15.5
5 ~
5 ~
59.9
59.9
zz
zz
zz
zz
zz
zz
zz
——
zz
zz
Category Functions
3MXS24NMVJU
4MXS36NMVJU
Health &
Clean
Timer WEEKLY TIMER operation — —
(Reliability &
Durability)
Control
Remote
Controller
Air-purifying filter — —
Photocatalytic deodorizing filter — —
Air-purifying filter with photocatalytic
deodorizing function
Titanium apatite photocatalytic
air-purifying filter
Longlife filter (option) — —
Air filter (prefilter) — —
Wipe-clean flat panel — —
Filter cleaning indicator — —
Auto-restart (after power failure) — —
Anti-corrosion treatment of outdoor heat
exchanger
Multi-split / split type compatible indoor
unit
High ceiling application — —
Chargeless
Power selection — —
°F/°C changeover R/C temperature
display (factory setting: °F)
5-room centralized controller (option) — —
Remote control adaptor
(normal open pulse contact) (option)
Remote control adaptor
(normal open contact) (option)
Wireless — —
Wired (option) — —
2MXS18NMVJU
——
——
zz
zz
zz
——
98.4
131.6
ft
(30 m)
(40 m)
——
——
——
— : Not available
3MXS24NMVJU
ft
4MXS36NMVJU
6 List of Functions
SiUS121502E
Part 2
Specifications
1. Indoor Unit...................................................................................................8
2. Outdoor Unit..............................................................................................14
Specifications 7
Indoor Unit SiUS121502E
1. Indoor Unit
60 Hz, 208 - 230 V
Model
Rated Capacity 7 kBtu/h Class
Front Panel Color Whit e
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A 0.09 - 0.08 0.11 - 0.10
Power Consumption (Rated) W 18 - 18 21 - 21
Power Factor (Rated) % 96.2 - 97.8 91.8 - 91.3
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-5/8 × 31-1/2 × 8-7/16 (295 × 800 × 215)
Packaged Dimensions (H × W × D) in. (mm) 10-13/16 × 34-1/4 × 14-7/16 (274 × 870 × 366)
Weight (Mass) Lbs (kg) 20 (9)
Gross Weight (Gross Mass) Lbs (kg) 29 (13)
Sound Pressure
Level
Sound Power Level dB 54 54
Heat Insulation Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D075490
H
M 261 (7.4) 290 (8.2)
L 194 (5.5) 233 (6.6)
SL 145 (4.1) 219 (6.2)
Type Cross Flow Fan
Motor Output W 23
Speed Steps 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 38 / 32 / 25 / 22 38 / 33 / 28 / 25
Liquid in. (mm) φ
Gas i n. ( mm) φ 3/8 (φ 9.5)
Drain in. (mm) φ 5/8 (φ 16.0)
cfm
(m³/min)
Cooling Heating
332 (9.4) 350 (9.9)
CTXS07LVJU
1/4 (φ 6.4)
Model
Rated Capacity 9 kBtu/h Class 12 kBtu/h Class
Front Panel Color White White
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.09 - 0.08 0.11 - 0.10 0.13 - 0.12 0.14 - 0.13
Power Consumption (Rated) W 18 - 18 21 - 21 26 - 26 28 - 28
Power Factor (Rated) % 96.2 - 97.8 91.8 - 91.3 96.2 - 94.2 96.2 - 93.6
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-5/8 × 31-1/2 × 8-7/16 (295 × 800 × 215) 11-5/8 × 31-1/2 × 8-7/16 (295 × 800 × 215)
Packaged Dimensions (H × W × D) in. (mm) 10-13/16 × 34-1/4 × 14-7/16 (274 × 870 × 366) 10-13/16 × 34-1/4 × 14-7/16 (274 × 870 × 366)
Weight (Mass) Lbs (kg) 20 (9) 22 (10)
Gross Weight (Gross Mass) Lbs (kg) 29 (13) 31 (14)
Sound Pressure
Level
Sound Power Level dB 57 58 61 61
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D075491 3D075492
H
M 279 (7.9) 321 (9.1) 307 (8.7) 335 (9.5)
L 194 (5.5) 233 (6.6) 205 (5.8) 240 (6.8)
SL 145 (4.1) 219 (6.2) 155 (4.4) 212 (6.0)
Type Cross Flow Fan Cross Flow Fan
Motor Output W 23 23
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 41 / 33 / 25 / 22 42 / 35 / 28 / 25 45 / 37 / 29 / 23 45 / 39 / 29 / 26
Liquid in. (mm) φ 1/4 (φ 6.4) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 3/8 (φ 9.5) φ 3/8 (φ 9.5)
Drain in. (mm) φ 5/8 (φ 16.0) φ 5/8 (φ 16.0)
cfm
(m³/min)
Cooling Heating Cooling Heating
381 (10.8) 420 (11.9) 403 (11.4) 438 (12.4)
FTXS09LVJU FTXS12LVJU
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
8 Specifications
SiUS121502E Indoor Unit
60 Hz, 208 - 230 V
Model
Rated Capacity 15 kBtu/h Class 18 kBtu/h Class
Front Panel Color White White
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.31 - 0.29 0.31 - 0.29 0.32 - 0.30 0.32 - 0.30
Power Consumption (Rated) W 38 - 38 38 - 38 38 - 38 38 - 38
Power Factor (Rated) % 58.9 - 57.0 58.9 - 57.0 57.1 - 55.1 57.1 - 55.1
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 13-3/8 × 41-5/16 × 9-3/4 (340 × 1,050 × 248) 13-3/8 × 41-5/16 × 9-3/4 (340 × 1,050 × 248)
Packaged Dimensions (H × W × D) in. (mm) 13 × 45-11/16 × 16-7/8 (331 × 1,160 × 429) 13 × 45-11/16 × 16-7/8 (331 × 1,160 × 429)
Weight (Mass) Lbs (kg) 31 (14) 31 (14)
Gross Weight (Gross Mass) Lbs (kg) 44 (20) 44 (20)
Sound Pressure
Level
Sound Power Level dB 61 59 62 61
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D075043 3D075044
H
M 477 (13.5) 505 (14.3) 484 (13.7) 526 (14.9)
L 385 (10.9) 417 (11.8) 385 (10.9) 431 (12.2)
SL 360 (10.2) 371 (10.5) 360 (10.2) 399 (11.3)
Type Cross Flow Fan Cross Flow Fan
Motor Output W 48 48
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 45 / 40 / 35 / 32 43 / 38 / 33 / 30 46 / 41 / 36 / 33 45 / 40 / 35 / 32
Liquid in. (mm) φ 1/4 (φ 6.4) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 1/2 (φ 12.7) φ 1/2 (φ 12.7)
Drain in. (mm) φ 5/8 (φ 16.0) φ 5/8 (φ 16.0)
cfm
(m³/min)
Cooling Heating Cooling Heating
568 (16.1) 593 (16.8) 583 (16.5) 625 (17.7)
FTXS15LVJU FTXS18LVJU
Model
Rated Capacity 24 kBtu/h Class
Front Panel Color Whit e
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A 0.57 - 0.51 0.57 - 0.51
Power Consumption (Rated) W 69 - 68 69 - 68
Power Factor (Rated) % 58.2 - 58.0 58.2 - 58.0
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 13-3/8 × 41-5/16 × 9-3/4 (340 × 1,050 × 248)
Packaged Dimensions (H × W × D) in. (mm) 13 × 45-11/16 × 16-7/8 (331 × 1,160 × 429)
Weight (Mass) Lbs (kg) 31 (14)
Gross Weight (Gross Mass) Lbs (kg) 46 (21)
Sound Pressure
Level
Sound Power Level dB 67 64
Heat Insulation Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D075045
H
M 494 (14.0) 572 (16.2)
L 350 (9.9) 445 (12.6)
SL 328 (9.3) 403 (11.4)
Type Cross Flow Fan
Motor Output W 48
Speed Steps 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 51 / 44 / 37 / 34 48 / 42 / 37 / 34
Liquid in. (mm) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 5/8 (φ 15.9)
Drain in. (mm) φ 5/8 (φ 16.0)
cfm
(m³/min)
Cooling Heating
643 (18.2) 699 (19.8)
FTXS24LVJU
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications 9
Indoor Unit SiUS121502E
60 Hz, 208 - 230 V
Model
Rated Capacity 9 kBtu/h Class 12 kBtu/h Class
External Static Pressure inAq (Pa) 0.12 (30) 0.12 (30)
Airflow Rate
Fan
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.58 - 0.52 0.58 - 0.52 0.58 - 0.52 0.58 - 0.52
Power Consumption (Rated) W 72 - 72 72 - 72 72 - 72 72 - 72
Power Factor (Rated) % 59.7 - 60.2 59.7 - 60.2 59.7 - 60.2 59.7 - 60.2
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 7-7/8 × 27-9/16 × 24-7/16 (200 × 700 × 620) 7-7/8 × 27-9/16 × 24-7/16 (200 × 700 × 620)
Packaged Dimensions (H × W × D) in. (mm) 10-13/16 × 36-5/16 × 30-1/4 (274 × 923 × 768) 10-13/16 × 36-5/16 × 30-1/4 (274 × 923 × 768)
Weight (Mass) Lbs (kg) 47 (21) 47 (21)
Gross Weight (Gross Mass) Lbs (kg) 64 (29) 64 (29)
Sound Pressure
Level
Sound Power Level dB 51 51 51 51
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D075493 3D075494
H
M 280 (7.9) 280 (7.9) 280 (7.9) 280 (7.9)
L 260 (7.4) 260 (7.4) 260 (7.4) 260 (7.4)
SL 235 (6.7) 235 (6.7) 235 (6.7) 235 (6.7)
Type Sirocco Fan Sirocco Fan
Motor Output W 62 62
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
H / M / L dB(A) 35 / 33 / 31 35 / 33 / 31 35 / 33 / 31 35 / 33 / 31
Liquid in. (mm) φ 1/4 (φ 6.4) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 3/8 (φ 9.5) φ 3/8 (φ 9.5)
Drain in. (mm) φ 25/32 (φ 20) φ 25/32 (φ 20)
cfm
(m³/min)
Cooling Heating Cooling Heating
305 (8.6) 305 (8.6) 305 (8.6) 305 (8.6)
FDXS09LVJU FDXS12LVJU
Model
Rated Capacity 15 kBtu/h Class 18 kBtu/h Class
External Static Pressure inAq (Pa) 0.16 (40) 0.16 (40)
Airflow Rate
Fan
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A 0.79 0.79 0.79 0.79
Power Consumption (Rated) W 172 172 172 172
Power Factor (Rated) % 94.4 94.4 94.4 94.4
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 7-7/8 × 35-7/16 × 24-7/16 (200 × 900 × 620) 7-7/8 × 35-7/16 × 24-7/16 (200 × 900 × 620)
Packaged Dimensions (H × W × D) in. (mm) 10-1/2 × 43-9/16 × 29-9/16 (266 × 1,106 × 751) 10-1/2 × 43-9/16 × 29-9/16 (266 × 1,106 × 751)
Weight (Mass) Lbs (kg) 60 (27) 60 (27)
Gross Weight (Gross Mass) Lbs (kg) 75 (34) 75 (34)
Sound Pressure
Level
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. C: 3D075721 C: 3D075722
H
M 388 (11.0) 388 (11.0) 388 (11.0) 388 (11.0)
L 353 (10.0) 353 (10.0) 353 (10.0) 353 (10.0)
SL 297 (8.4) 297 (8.4) 297 (8.4) 297 (8.4)
Type Sirocco Fan Sirocco Fan
Motor Output W 130 130
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 37 / 35 / 33 / 31 37 / 35 / 33 / 31 37 / 35 / 33 / 31 37 / 35 / 33 / 31
Liquid in. (mm) φ 1/4 (φ 6.4) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 1/2 (φ 12.7) φ 1/2 (φ 12.7)
Drain in. (mm) VP20 (O.D. φ 1-1/32 (φ 26), I.D. φ 25/32 (φ 20)) VP20 (O.D. φ 1-1/32 (φ 26), I.D. φ 25/32 (φ 20))
cfm
(m³/min)
Cooling Heating Cooling Heating
424 (12.0) 424 (12.0) 424 (12.0) 424 (12.0)
CDXS15LVJU CDXS18LVJU
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
10 Specifications
SiUS121502E Indoor Unit
60 Hz, 208 - 230 V
Model
Rated Capacity 24 kBtu/h Class
External Static Pressure inAq (Pa) 0.16 (40)
Airflow Rate
Fan
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A 0.79 0.79
Power Consumption (Rated) W 160 160
Power Factor (Rated) % 90.3 92.8
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 7-7/8 × 43-5/16 × 24-7/16 (200 × 1,100 × 620)
Packaged Dimensions (H × W × D) in. (mm) 10-1/2 × 52-1/16 × 30-1/4 (266 × 1,323 × 768)
Weight (Mass) Lbs (kg) 66 (30)
Gross Weight (Gross Mass) Lbs (kg) 84 (38)
Sound Pressure
Level
Heat Insulation Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D080590
H
M 523 (14.8) 523 (14.8)
L 477 (13.5) 477 (13.5)
SL 395 (11.2) 395 (11.2)
Type Sirocco Fan
Motor Output W 130
Speed Steps 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 38 / 36 / 34 / 32 38 / 36 / 34 / 32
Liquid in. (mm) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 5/8 (φ 15.9)
Drain in. (mm) VP20 (O.D. φ 1-1/32 (φ 26), I.D. φ 25/32 (φ 20))
cfm
(m³/min)
Cooling Heating
565 (16.0) 565 (16.0)
CDXS24LVJU
Model
Rated Capacity 9 kBtu/h Class 12 kBtu/h Class
Front Panel Color White White
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof Removable, Washable, Mildew Proof
Running Current (Rated) A — — — —
Power Consumption (Rated) W — — — —
Power Factor (Rated) % — — — —
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 23-5/8 × 27-9/16 × 8-1/4 (600 × 700 × 210) 23-5/8 × 27-9/16 × 8-1/4 (600 × 700 × 210)
Packaged Dimensions (H × W × D) in. (mm) 27-3/8 × 30-15/16 × 11 (695 × 786 × 279) 27-3/8 × 30-15/16 × 11 (695 × 786 × 279)
Weight (Mass) Lbs (kg) 31 (14) 31 (14)
Gross Weight (Gross Mass) Lbs (kg) 40 (18) 40 (18)
Sound Pressure
Level
Sound Power Level dB — — — —
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D094867 3D094868
H
M 230 (6.5) 244 (6.9) 237 (6.7) 258 (7.3)
L 169 (4.8) 177 (5.0) 173 (4.9) 184 (5.2)
SL 145 (4.1) 155 (4.4) 159 (4.5) 166 (4.7)
Type Turbo Fan Turbo Fan
Motor Output W 12.3 13.4
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 38 / 32 / 26 / 23 38 / 32 / 26 / 23 39 / 33 / 27 / 24 39 / 33 / 27 / 24
Liquid in. (mm) φ 1/4 (φ 6.4) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 3/8 (φ 9.5) φ 3/8 (φ 9.5)
Drain in. (mm) φ 13/16 (φ 20.0) φ 13/16 (φ 20.0)
cfm
(m³/min)
Cooling Heating Cooling Heating
290 (8.2) 311 (8.8) 300 (8.5) 332 (9.4)
FVXS09NVJU FVXS12NVJU
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications 11
Indoor Unit SiUS121502E
60 Hz, 208 - 230 V
Model
Rated Capacity 18 kBtu/h Class
Front Panel Color Whit e
Airflow Rate
Fan
Air Direction Control Right, Left, Horizontal, Downward
Air Filter Removable, Washable, Mildew Proof
Running Current (Rated) A — —
Power Consumption (Rated) W — —
Power Factor (Rated) % — —
Temperature Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 23-5/8 × 27-9/16 × 8-1/4 (600 × 700 × 210)
Packaged Dimensions (H × W × D) in. (mm) 27-3/8 × 30-15/16 × 11 (695 × 786 × 279)
Weight (Mass) Lbs (kg) 31 (14)
Gross Weight (Gross Mass) Lbs (kg) 40 (18)
Sound Pressure
Level
Sound Power Level dB — —
Heat Insulation Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D094866
H
M 325 (9.2) 357 (10.1)
L 275 (7.8) 300 (8.5)
SL 233 (6.6) 251 (7.1)
Type Turbo Fan
Motor Output W 23.3
Speed Steps 5 Steps, Quiet, Auto
H / M / L / SL dB(A) 44 / 40 / 36 / 32 45 / 40 / 36 / 32
Liquid in. (mm) φ 1/4 (φ 6.4)
Gas i n. ( mm) φ 1/2 (φ 12.7)
Drain in. (mm) φ 13/16 (φ 20.0)
cfm
(m³/min)
Cooling Heating
378 (10.7) 417 (11.8)
FVXS18NVJU
Model
Rated Capacity 9 kBtu/h Class 12 kBtu/h Class
Decoration Panel
Airflow Rate
Fan
Air Direction Control Horizontal, Downward Horizontal, Downward
Running Current (Rated) A 0.44 0.38 0.47 0.42
Power Consumption (Rated) W 87 76 98 89
Power Factor % 85.8 87.0 91.3 91.8
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-1/4 × 22-5/8 × 22-5/8 (285 × 575 × 575) 11-1/4 × 22-5/8 × 22-5/8 (285 × 575 × 575)
Packaged Dimensions (H × W × D) in. (mm) 14-9/16 × 27-1/16 × 26-9/16 (370 × 687 × 674) 14-9/16 × 27-1/16 × 26-9/16 (370 × 687 × 674)
Weight (Mass) Lbs (kg) 38.6 (17.5) 38.6 (17.5)
Gross Weight (Gross Mass) Lbs (kg) 46 (21) 46 (21)
Sound Pressure
Level
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D080626A 3D080627A
Model BYFQ60B3W1 BYFQ60B3W1
Color White White
Dimensions (H × W × D) 2-5/32 × 27-9/16 × 27-9/16 (55 × 700 × 700) 2-5/32 × 27-9/16 × 27-9/16 (55 × 700 × 700)
Weight (Mass) Lbs (kg) 6 (2.7) 6 (2.7)
H
L 230 (6.5) 230 (6.5) 230 (6.5) 230 (6.5)
Type Turbo Fan Turbo Fan
Motor Output W 55 55
Speed Steps 2 Steps 2 Steps
H / L dB(A) 36.0 / 29.5 36.0 / 29.5 38.5 / 29.0 38.5 / 29.0
Liquid in. (mm)
Gas i n. ( mm)
Drain in. (mm) VP20 (O.D.
cfm
(m³/min)
Cooling Heating Cooling Heating
318 (9.0) 318 (9.0) 353 (10.0) 353 (10.0)
FFQ09LVJU FFQ12LVJU
(φ
(φ
6.4
9.5)
(
φ
26) / I.D.
)
φ
20) VP20 (O.D.
(φ
25/32
φ
1-1/32
φ
1-1/32
φ
φ
1/4
3/8
φ
φ
1/4
3/8
(
(
φ
9.5)
(
φ
26) / I.D.
φ
6.4
)
(
φ
φ
25/32
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
20)
12 Specifications
SiUS121502E Indoor Unit
60 Hz, 208 - 230 V
Model
Rated Capacity 15 kBtu/h Class 18 kBtu/h Class
Decoration Panel
Airflow Rate
Fan
Air Direction Control Horizontal, Downward Horizontal, Downward
Running Current (Rated) A 0.57 0.52 0.71 0.65
Power Consumption (Rated) W 112 103 140 130
Power Factor % 86.1 86.0 85.5 86.2
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) in. (mm) 11-1/4 × 22-5/8 × 22-5/8 (285 × 575 × 575) 11-1/4 × 22-5/8 × 22-5/8 (285 × 575 × 575)
Packaged Dimensions (H × W × D) in. (mm) 14-9/16 × 27-1/16 × 26-9/16 (370 × 687 × 674) 14-9/16 × 27-1/16 × 26-9/16 (370 × 687 × 674)
Weight (Mass) Lbs (kg) 38.6 (17.5) 38.6 (17.5)
Gross Weight (Gross Mass) Lbs (kg) 46 (21) 46 (21)
Sound Pressure
Level
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connections
Drawing No. 3D080628A 3D080629A
Model BYFQ60B3W1 BYFQ60B3W1
Color White White
Dimensions (H × W × D) 2-5/32 × 27-9/16 × 27-9/16 (55 × 700 × 700) 2-5/32 × 27-9/16 × 27-9/16 (55 × 700 × 700)
Weight (Mass) Lbs (kg) 6 (2.7) 6 (2.7)
H
L 283 (8.0) 283 (8.0) 353 (10.0) 353 (10.0)
Type Turbo Fan Turbo Fan
Motor Output W 55 55
Speed Steps 2 Steps 2 Steps
H / L dB(A) 42.5 / 31.5 42.5 / 31.5 46.0 / 37.5 46.0 / 37.5
Liquid in. (mm)
Gas i n. ( mm)
Drain in. (mm) VP20 (O.D.
cfm
(m³/min)
Cooling Heating Cooling Heating
424 (12.0) 424 (12.0) 530 (15.0) 530 (15.0)
FFQ15LVJU FFQ18LVJU
(φ
(
(φ
6.4
12.7)
φ
26) / I.D.
)
φ
20) VP20 (O.D.
(φ
25/32
φ
1-1/32
φ
1-1/32
φ
1/4
φ
1/2
φ
φ
1/4
1/2
(
(
φ
(
φ
)
φ
6.4
12.7)
26) / I.D.
φ
25/32
20)
(
φ
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications 13
Outdoor Unit SiUS121502E
2. Outdoor Unit
60 Hz, 208 - 230 V
Model
COP
EER
SEER / HSPF 14.0
Casing Color Ivory White
Compressor
Refrigerant Oil
Refrigerant
Airflow Rate
Fan
Starting Current A 14.0
Dimension (H × W × D) in. (mm) 28-15/16 × 34-1/4 × 12-5/8 (735 × 870 × 320)
Packaged Dimension (H × W × D) in. (mm) 31-7/8 × 41-9/16 × 17-1/2 (810 × 1,056 × 444)
Weight (Mass) Lbs (kg) 123 (56)
Gross Weight (Gross Mass) Lbs (kg) 141 (64)
Sound Pressure Level dB(A) 50 51
Piping
Connections
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connections 3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length ft (m)
Amount of Additional Charge of
Refrigerant
Max. Installation Height Difference ft (m)
Drawing No. 3D093257
Type Hermetically Sealed Swing Type
Model 2YC36PXD
Motor Output W 1,100
Model FVC50K
Charge oz (L) 21.5 (0.61)
Type R-410A
Charge Lbs (kg) 3.86 (1.75)
H
M 2,150 2,179
L 1,953 1,119
H
M 60.9 61.7
L 55.3 31.7
Type Propeller
Motor Output W 56
Running Current A H: 0.29 / M: 0.29 / L: 0.25 H: 0.29 / M: 0.29 / L: 0.05
Power Consumption W H: 65 / M: 65 / L: 58 H: 66 / M: 66 / L: 12
Liquid in. (mm) φ 1/4 × 2 (φ 6.4 × 2)
Gas in. (mm) φ 3/8 × 1, φ 1/2 × 1 (φ 9.5 × 2, φ 12.7 × 1)
Drain in. (mm) φ 11/16 (φ 18.0)
Notes:
1.Max.: for the combination of CTXS, FTXS series indoor units
2. The data are based on the conditions shown in the table below.
W/W — 4.1
Btu/h·W 9.5 ~ 12.5 —
cfm
m³/min
oz/ft
(g/m)
Min.: for the combination of CDXS, FDXS series indoor units
Cooling
Heating
Piping Length 25 ft (7.5 m)
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
Cooling Heating
18.9 8.2 ~ 10.7
~
2,150 2,179
60.9 61.7
49-1/4 (15) (between Indoor Unit and Outdoor Unit)
2MXS18NMVJU
164 (50) (for Total of Each Room)
82 (25) (for One Room)
0.21 (20) (98-3/8 ft (30 m) or more)
24-5/8 (7.5) (between Indoor Units)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
14 Specifications
SiUS121502E Outdoor Unit
60 Hz, 208 - 230 V
Model
COP
EER
SEER / HSPF 14.0
Casing Color Ivory White
Compressor
Refrigerant Oil
Refrigerant
Airflow Rate
Fan
Starting Current A 15.5
Dimension (H × W × D) in. (mm) 28-15/16 × 34-1/4 × 12-5/8 (735 × 870 × 320)
Packaged Dimension (H × W × D) in. (mm) 31-7/8 × 41-9/16 × 17-1/2 (810 × 1,056 × 444)
Weight (Mass) Lbs (kg) 137 (62)
Gross Weight (Gross Mass) Lbs (kg) 154 (70)
Sound Pressure Level dB(A) 52 54
Piping
Connections
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connections 3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length ft (m)
Amount of Additional Charge of
Refrigerant
Max. Installation Height Difference ft (m)
Drawing No. 3D093259
Type Hermetically Sealed Swing Type
Model 2YC63AAXD
Motor Output W 1,920
Model FVC50K
Charge oz (L) 29.8 (0.85)
Type R-410A
Charge Lbs (kg) 6.17 (2.8)
H
M 2,094 1,981
L 1,981 1,119
H
M 59.3 56.1
L 56.1 31.7
Type Propeller
Motor Output W 51
Running Current A H: 0.28 / M: 0.28 / L: 0.26 H: 0.28 / M: 0.26 / L: 0.05
Power Consumption W H: 63 / M: 63 / L: 59 H: 63 / M: 59 / L: 12
Liquid in. (mm) φ 1/4 × 3 (φ 6.4 × 3)
Gas in. (mm) φ 3/8 × 1, φ 1/2 × 2 (φ 9.5 × 1, φ 12.7 × 2)
Drain in. (mm) φ 11/16 (φ 17.5)
Notes:
1.Max.: for the combination of CTXS, FTXS series indoor units
2. The data are based on the conditions shown in the table below.
W/W — 3.2 ~ 4.6
Btu/h·W 9.7 ~ 12.7 —
cfm
m³/min
oz/ft
(g/m)
Min.: for the combination of CDXS, FDXS series indoor units
Cooling
Heating
Piping Length 25 ft (7.5 m)
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
Cooling Heating
17.9 8.2 ~ 12.5
~
2,094 2,094
59.3 59.3
49-1/4 (15) (between Indoor Unit and Outdoor Unit)
3MXS24NMVJU
230 (70) (for Total of Each Room)
82 (25) (for One Room)
0.21 (20) (131-5/8 ft (40 m) or more)
24-5/8 (7.5) (between Indoor Units)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Specifications 15
Outdoor Unit SiUS121502E
60 Hz, 208 - 230 V
Model
COP
EER
SEER / HSPF 14.0
Casing Color Ivory White
Compressor
Refrigerant Oil
Refrigerant
Airflow Rate
Fan
Starting Current A 17.5
Dimension (H × W × D) in. (mm) 28-15/16 × 34-1/4 × 12-5/8 (735 × 870 × 320)
Packaged Dimension (H × W × D) in. (mm) 31-7/8 × 41-9/16 × 17-1/2 (810 × 1,056 × 444)
Weight (Mass) Lbs (kg) 139 (63)
Gross Weight (Gross Mass) Lbs (kg) 157 (71)
Sound Pressure Level dB(A) 54 56
Piping
Connections
Heat Insulation Both Liquid and Gas Pipes
No. of Wiring Connections 3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length ft (m)
Amount of Additional Charge of
Refrigerant
Max. Installation Height Difference ft (m)
Drawing No. 3D093260
Type Hermetically Sealed Swing Type
Model 2YC63AAXD
Motor Output W 1,920
Model FVC50K
Charge oz (L) 29.8 (0.85)
Type R-410A
Charge Lbs (kg) 6.17 (2.8)
H
M 2,440 2,210
L 1,727 1,119
H
M 69.1 62.6
L 59.3 31.7
Type Propeller
Motor Output W 75
Running Current A H: 0.52 / M: 0.40 / L: 0.27 H: 0.38 / M: 0.32 / L: 0.06
Power Consumption W H: 116 / M: 90 / L: 61 H: 85 / M: 72 / L: 14
Liquid in. (mm) φ 1/4 × 4 (φ 6.4 × 4)
Gas in. (mm) φ 3/8 × 1, φ 1/2 × 2, φ 5/8 × 1 (φ 9.5 × 1, φ 12.7 × 2, φ 15.9 × 1)
Drain in. (mm) φ 11/16 (φ 17.5)
Notes:
1.Max.: for the combination of CTXS, FTXS series indoor units
2. The data are based on the conditions shown in the table below.
W/W — 3.5 ~ 4.5
Btu/h·W 7.9 ~ 9.2 —
cfm
m³/min
oz/ft
(g/m)
Min.: for the combination of CDXS, FDXS series indoor units
Cooling
Heating
Piping Length 25 ft (7.5 m)
Indoor ; 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
Outdoor ; 95°FDB (35°CDB) / 75°FWB (24°CWB)
Indoor ; 70°FDB (21°CDB) / 60°FWB (15.6°CWB)
Outdoor ; 47°FDB (8.3°CDB) / 43°FWB (6°CWB)
Cooling Heating
17.7 8.2 ~ 12.2
~
2,613 2,351
74.0 66.6
49-1/4 (15) (between Indoor Unit and Outdoor Unit)
4MXS36NMVJU
230 (70) (for Total of Each Room)
82 (25) (for One Room)
0.21 (20) (131-5/8 ft (40 m) or more)
24-5/8 (7.5) (between Indoor Units)
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
16 Specifications
SiUS121502E
Part 3
Printed Circuit Board
Connector Wiring Diagram
1. Indoor Unit.................................................................................................18
1.1 CTXS07LVJU, FTXS09/12LVJU ................................................................ 18
1.2 FTXS15/18/24LVJU ................................................................................... 20
1.3 FDXS09/12LVJU, CDXS15/18/24LVJU ..................................................... 22
1.4 FVXS09/12/18NVJU................................................................................... 24
1.5 FFQ09/12/15/18LVJU ................................................................................ 26
2. Wired Remote Controller...........................................................................27
2.1 BRC1E71 ................................................................................................... 27
2.2 BRC1E72/73 .............................................................................................. 28
3. Wireless Remote Controller ......................................................................29
3.1 BRC7E830 ................................................................................................. 29
4. Outdoor Unit..............................................................................................30
Printed Circuit Board Connector Wiring Diagram 17
Indoor Unit SiUS121502E
1. Indoor Unit
1.1 CTXS07LVJU, FTXS09/12LVJU
Control PCB
(PCB1)
1) S1 Connector for DC fan motor
2) S21 Connector for centralized control (HA)
3) S25 Connector for INTELLIGENT EYE sensor PCB
4) S32 Indoor heat exchanger thermistor
5) S41 Connector for swing motors
6) S46 Connector for display PCB
7) S47 Connector for signal receiver PCB
8) H1, H2, H3, FG Connector for terminal board
9) JA Address setting jumper
∗ Refer to page 189 for detail.
10)JB Fan speed setting when compressor stops for thermostat OFF
∗ Refer to page 191 for detail.
11)JC Power failure recovery function (auto-restart)
∗ Refer to page 191 for detail.
12)LED A LED for service monitor (green)
13)FU1 (F1U), FU2 Fuse (3.15 A, 250 V)
14)V1 Varistor
S1 S41
S46
S25
S47
JC
JA
S32
LED A
FU2
JB
S21
FG
FU1
Caution Replace the PCB if you accidentally cut the jumpers other than JA, JB, and JC.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
H1 H2 H3
V1
2P206687-4
Note: The symbols in the parenthesis are the names on the appropriate wiring diagram.
18 Printed Circuit Board Connector Wiring Diagram