Daikin 2MXM68N2V1B, 3MXM40N2V1B9, 3MXM40N2V1B8, 3MXM40N2V1B7, 3MXM52N2V1B9 Installer reference guide [hu]

...
Szerelői referencia-útmutató
R32 Split sorozat
2MXM68N2V1B
3MXM40N2V1B9 3MXM40N2V1B8 3MXM40N2V1B7 3MXM52N2V1B9 3MXM52N2V1B8 3MXM52N2V1B7 3MXM68N2V1B9 3AMXM52N2V1B9 3AMXF52A2V1B9
3MXF52A2V1B9 3MXF68A2V1B9
4MXM68N2V1B9 4MXM80N2V1B9 5MXM90N2V1B9

Tartalomjegyzék

Tartalomjegyzék
1 A dokumentum bemutatása 4
1.1 A dokumentum bemutatása........................................................................................................................................... 4
2 Általános biztonsági óvintézkedések 5
2.1 A dokumentum bemutatása........................................................................................................................................... 5
2.1.1 A figyelmeztetések és szimbólumok jelentése .............................................................................................. 5
2.2 A szerelőnek.................................................................................................................................................................... 6
2.2.1 Általános ......................................................................................................................................................... 6
2.2.2 Felszerelés helye............................................................................................................................................. 7
2.2.3 Hűtőközeg — R410A vagy R32 esetében....................................................................................................... 10
2.2.4 Elektromos ...................................................................................................................................................... 12
3 A szerelőknek szóló biztonsági utasítások 15
4 A doboz bemutatása 20
4.1 Áttekintés: A doboz bemutatása .................................................................................................................................... 20
4.2 Kültéri egység.................................................................................................................................................................. 20
4.2.1 A kültéri egység kicsomagolása ...................................................................................................................... 20
4.2.2 Tartozékok eltávolítása a kültéri egységből ................................................................................................... 21
5 Az egység bemutatása 23
5.1 Áttekintés: Az egység bemutatása ................................................................................................................................. 23
5.2 Azonosítás ....................................................................................................................................................................... 23
5.2.1 Azonosítási címke: Kültéri egység .................................................................................................................. 24
6 Az egység felszerelése 25
6.1 A berendezés helyének előkészítése.............................................................................................................................. 25
6.1.1 A kültéri egység felszerelési helyére vonatkozó követelmények .................................................................. 26
6.1.2 A kültéri egység felszerelési helyére vonatkozó további követelmények hideg éghajlat esetén ................. 28
6.2 Az egység felnyitása ........................................................................................................................................................ 29
6.2.1 Az egység felnyitásáról ................................................................................................................................... 29
6.2.2 A kültéri egység felnyitása.............................................................................................................................. 29
6.3 A kültéri egység felszerelése........................................................................................................................................... 29
6.3.1 A kültéri egység felszereléséről...................................................................................................................... 29
6.3.2 Óvintézkedések a kültéri egység felszerelésénél........................................................................................... 30
6.3.3 Az üzembe helyezés szerkezetének létrehozása ........................................................................................... 30
6.3.4 A kültéri egység felszerelése .......................................................................................................................... 31
6.3.5 A kondenzvíz-elvezetés biztosításához .......................................................................................................... 31
6.3.6 A kültéri egység ledőlésének megakadályozása ............................................................................................ 32
7 A csövek felszerelése 33
7.1 A hűtőközegcsövek előkészítése .................................................................................................................................... 33
7.1.1 A hűtőközegcsövekre vonatkozó követelmények.......................................................................................... 33
7.1.2 A hűtőközegcsövek szigetelése ...................................................................................................................... 34
7.1.3 Hűtőközegcső hossza és szintkülönbsége...................................................................................................... 35
7.2 A hűtőközegcsövek csatlakoztatása ............................................................................................................................... 36
7.2.1 A hűtőközegcsövek csatlakoztatása ............................................................................................................... 36
7.2.2 A hűtőközegcsövek összekötésével kapcsolatos biztonsági előírások .......................................................... 36
7.2.3 Útmutató a hűtőközegcsövek összekötéséhez.............................................................................................. 38
7.2.4 Csőhajlítási útmutató ..................................................................................................................................... 38
7.2.5 A csővég tokozása........................................................................................................................................... 38
7.2.6 Csatlakozás a kültéri és a beltéri egységek között, szűkítő elemmel ............................................................ 39
7.2.7 Elzárószelep és szervizcsatlakozó használata ................................................................................................ 42
7.2.8 A hűtőközegcsövek csatlakoztatása a kültéri egységhez............................................................................... 43
7.3 A hűtőközegcsövek ellenőrzése...................................................................................................................................... 44
7.3.1 A hűtőközegcsövek ellenőrzése ..................................................................................................................... 44
7.3.2 A hűtőközegcsövek ellenőrzésévek kapcsolatos biztonsági előírások .......................................................... 44
7.3.3 A szivárgás ellenőrzése ................................................................................................................................... 45
7.3.4 Vákuumszivattyús szárítás végrehajtása ........................................................................................................ 45
2
8 Hűtőközeg feltöltése 47
8.1 Hűtőközeg feltöltése....................................................................................................................................................... 47
8.2 A hűtőközegről................................................................................................................................................................ 48
8.3 A hűtőközeg feltöltésével kapcsolatos biztonsági előírások.......................................................................................... 49
8.4 A további hűtőközeg mennyiségének meghatározása .................................................................................................. 49
8.5 A teljes újratöltéshez szükséges mennyiség meghatározása......................................................................................... 49
8.6 A hűtőközeg-utántöltése ................................................................................................................................................ 50
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
Tartalomjegyzék
8.7 A fluorozott üvegházhatású gázokra figyelmeztető címke rögzítése ............................................................................ 50
9 Elektromos felszerelés 51
9.1 Az elektromos huzalozás csatlakoztatásának bemutatása ............................................................................................ 51
9.1.1 Óvintézkedések az elektromos huzalozás csatlakoztatásakor ...................................................................... 51
9.1.2 Irányelvek az elektromos huzalozás csatlakoztatásához ............................................................................... 53
9.1.3 A szabványos huzalozási összetevők műszaki jellemzői ................................................................................ 54
9.2 Elektromos huzalok csatlakoztatása a kültéri egységhez............................................................................................... 55
10 A kültéri egység felszerelésének befejezése 57
10.1 A kültéri egység felszerelésének befejezése .................................................................................................................. 57
10.2 A kültéri egység lezárása................................................................................................................................................. 57
11 Beállítás 58
11.1 A készenléti energiatakarékos funkció ismertetése....................................................................................................... 58
11.1.1 A készenléti energiatakarékos funkció bekapcsolása .................................................................................... 58
11.2 Az elsődleges helyiség funkció........................................................................................................................................ 59
11.2.1 Az elsődleges helyiség funkció beállítása....................................................................................................... 59
11.3 Az "éjszakai csendes" üzemmódról ................................................................................................................................ 59
11.3.1 Az éjszakai csendes üzemmód bekapcsolása................................................................................................. 60
11.4 Fűtés mód zárolása ......................................................................................................................................................... 60
11.4.1 Fűtés mód zárolása bekapcsolása .................................................................................................................. 60
11.5 Hűtés mód zárolása ........................................................................................................................................................ 60
11.5.1 Hűtés mód zárolása bekapcsolása ................................................................................................................. 60
12 Beüzemelés 62
12.1 Áttekintés: Beüzemelés .................................................................................................................................................. 62
12.2 Biztonsági előírások a beüzemeléskor............................................................................................................................ 62
12.3 Beüzemelés előtti ellenőrzőlista..................................................................................................................................... 63
12.4 Beüzemelés közbeni ellenőrzőlista................................................................................................................................. 63
12.5 Próbaüzem és teszt......................................................................................................................................................... 63
12.5.1 A huzalozás hibaellenőrzésének ismertetése ................................................................................................ 64
12.5.2 Próbaüzem végrehajtása ................................................................................................................................ 65
12.6 A kültéri egység beindítása............................................................................................................................................. 66
13 Átadás a felhasználónak 67
14 Karbantartás és szerelés 68
14.1 Áttekintés: karbantartás és szerelés............................................................................................................................... 68
14.2 Biztonsági óvintézkedések a karbantartásra vonatkozóan ............................................................................................ 68
14.3 A kültéri egység éves karbantartásának ellenőrzőlistája ............................................................................................... 68
14.4 A kompresszorról ............................................................................................................................................................ 69
15 Hibaelhárítás 70
15.1 Áttekintés: Hibaelhárítás ................................................................................................................................................ 70
15.2 Biztonsági előírások hibaelhárítás esetén ...................................................................................................................... 70
15.3 Problémák megoldása tünetek alapján.......................................................................................................................... 70
15.3.1 Jelenség: A beltéri egységek leesnek, rezonálnak vagy zajt okoznak............................................................ 70
15.3.2 Jelenség: Az egység NEM fűt vagy hűt kielégítően ........................................................................................ 71
15.3.3 Jelenség: Vízszivárgás ..................................................................................................................................... 71
15.3.4 Jelenség: Elektromos zárlat ............................................................................................................................ 71
15.3.5 Jelenség: Az elsődleges helyiség beállítás funkció NEM működik................................................................. 71
15.3.6 Jelenség: Az egység NEM működik megfelelően vagy égéses meghibásodás történt ................................. 71
15.4 Hibaelhárítás a hibajelző LED lámpák alapján................................................................................................................ 72
15.4.1 Hibadiagnosztika a kültéri egység PCB paneljén található LED használatával .............................................. 72
16 Hulladékkezelés 74
16.1 Áttekintés: Hulladékba helyezés..................................................................................................................................... 74
16.2 Leszivattyúzás.................................................................................................................................................................. 74
16.3 A kényszerített hűtés indítása és leállítása..................................................................................................................... 75
17 Műszaki adatok 77
17.1 Huzalozási rajz................................................................................................................................................................. 77
17.1.1 Egyesített huzalozási rajz jelmagyarázata ...................................................................................................... 77
17.2 Csövek rajza: Kültéri egység............................................................................................................................................ 79
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
18 Szószedet 84
3
1 | A dokumentum bemutatása

1 A dokumentum bemutatása

1.1 A dokumentum bemutatása

Célközönség
Képesített szerelők
INFORMÁCIÓ
A készülék tapasztalt vagy képzett felhasználók általi áruházi, könnyűipari vagy mezőgazdasági, illetve nem szakemberek általi kereskedelmi és háztartási használatra lett tervezve.
FIGYELEM
Ügyeljen rá, hogy a beszerelés, a szervizelés, a karbantartás, a javítás és a felhasznált anyagok megfeleljenek a Daikin utasításainak és a jogszabályi előírásoknak, és a munkát kizárólag szakember végezze el. Európában, valamint az IEC szabványokat használó területeken az EN/IEC 60335-2-40 a vonatkozó szabvány.
INFORMÁCIÓ
Ez a dokumentum csak a kültéri egység felszerelésével kapcsolatos információkat tartalmazza. A beltéri egység beszereléséhez (a beltéri egység felszerelése, hűtőközegcső csatlakoztatása a beltéri egységhez, elektromos hozalozás bekötése a beltéri egységre…) lásd a beltéri egység szerelési útutatóját.
Dokumentációkészlet
Ez a dokumentum egy dokumentációkészlet része. A teljes dokumentációkészlet a következőkből áll:
Általános biztonsági előírások:
- Biztonsági utasítások, melyeket üzembe helyezés előtt el KELL olvasni
- Formátum: Papír (a kültéri egység dobozában)
Kültéri egység szerelési kézikönyve:
- Szerelési utasítások
- Formátum: Papír (a kültéri egység dobozában)
Szerelői referencia-útmutató:
- Üzembe helyezés előkészítése, referencia adatok…
- Formátum: Digitális formában is elérhető: http://www.daikineurope.com/
support-and-manuals/product-information/
4
A mellékelt dokumentáció legújabb verzióját a regionális Daikin webhelyen vagy forgalmazójától szerezheti be.
Az eredeti dokumentum angol nyelven íródott. A más nyelvű kiadások ennek fordításai.
Műszaki technikai adatok
A műszaki adatok legújabb verziójának kiegészítését a regionális Daikin
webhelyen (nyilvánosan hozzáférhető) szerezheti be.
A műszaki adatok legújabb verziójának teljes dokumentációját a Daikin Business
Portal (jelszó szükséges) szerezheti be.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
2 | Általános biztonsági óvintézkedések

2 Általános biztonsági óvintézkedések

2.1 A dokumentum bemutatása

Az eredeti dokumentum angol nyelven íródott. A más nyelvű kiadások ennek
fordításai.
A dokumentumban leírt óvintézkedések mindegyike nagyon fontos témákat fed
le, ezért pontosan kövesse azokat.
A rendszer üzembe helyezését és a szerelési kézikönyvben, valamint a
beszereléshez adott referencia útmutatóban leírt összes tevékenységet CSAK az erre jogosult szakember végezheti el.

2.1.1 A figyelmeztetések és szimbólumok jelentése

VESZÉLY
Súlyos vagy halálos sérülést okozó helyzet.
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Áramütés veszélye.
VESZÉLY: ÉGÉS/FORRÁZÁS VESZÉLYE
Olyan helyzetet jelez, ahol a rendkívül magas hőmérséklet miatt fennáll az égés/ forrázás veszélye.
VESZÉLY: ROBBANÁSVESZÉLY
Robbanás veszélye.
FIGYELEM
Súlyos vagy halálos sérülés veszélye.
FIGYELMEZTETÉS: TŰZVESZÉLYES ANYAG
VIGYÁZAT
Enyhe vagy közepesen súlyos sérülés veszélye.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
MEGJEGYZÉS
Berendezések vagy vagyontárgyak sérülésének veszélye.
INFORMÁCIÓ
Hasznos tipp vagy további információ.
Az egységen használt jelölések:
5
2 | Általános biztonsági óvintézkedések
Jelölés Magyarázat
A dokumentumban használt jelölések:
Jelölés Magyarázat
Beszerelés előtt olvassa el a szerelési és üzemeltetési kézikönyvet, illetve tekintse meg a huzalozási útmutató ábrát.
Karbantartás elvégzése és szervizelés előtt olvassa el a szerelési kézikönyvet.
További információkat az "Referencia útmutató a beszereléshez és a használathoz" kiadványban talál.
Az egység forgó alkatrészeket tartalmaz. Legyen óvatos az egység szervizelése vagy ellenőrzése közben.
Az ábra címét vagy a rá mutató hivatkozást jelzi. Példa: " 1–3 ábra címe" az "1. fejezet 3. ábráját" jelenti.
A táblázat címét vagy a rá mutató hivatkozást jelzi. Példa: " 1–3 táblázat címe" az "1. fejezet 3. táblázatát"
jelenti.

2.2 A szerelőnek

2.2.1 Általános

Ha NEM biztos abban, miként szerelje fel vagy működtesse az egységet, lépjen kapcsolatba forgalmazójával.
VESZÉLY: ÉGÉS/FORRÁZÁS VESZÉLYE
Működés közben vagy közvetlenül utána NE érintse meg a hűtő- és vízcsöveket
vagy a belső alkatrészeket. Azok hőmérséklete túlságosan magas vagy alacsony lehet. Várjon, amíg az alkatrészek ismét megfelelő hőmérsékletűek lesznek. Ha mindenképpen meg kell érintenie azokat, viseljen védőkesztyűt.
NE érintse meg az esetleg kiszivárgó hűtőfolyadékot.
FIGYELEM
A helytelen üzembe helyezés, illetve a berendezés vagy kiegészítők helytelen csatlakoztatása áramütést, rövidzárlatot, szivárgást, tüzet vagy a berendezés egyéb károsodását okozhatja. Kizárólag a Daikin által gyártott vagy jóváhagyott tartozékokat, opcionális berendezéseket és pótalkatrészeket használjon.
FIGYELEM
Győződjön meg róla, hogy a szerelés, a tesztelés és a felhasznált alapanyagok kiválasztása a vonatkozó törvényi előírások szerint történik (a Daikin dokumentációban leírt útmutatások betartása mellett).
6
VIGYÁZAT
A rendszer szerelése, karbantartása és szervizelése során viseljen megfelelő védőfelszerelést (védőkesztyűt és -szemüveget stb.).
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
2 | Általános biztonsági óvintézkedések
FIGYELEM
A műanyag csomagoló tasakokat kidobás előtt szét kell tépni, hogy a gyermekek véletlenül se játszhassanak velük. Lehetséges kockázat: fulladás.
FIGYELEM
Akadályozza meg, hogy az egységbe kisebb termetű állatok fészkeljék be magukat. Az elektromos alkatrészekre mászó kis élőlények működészavarokat, füstölést vagy tüzet is okozhatnak.
VIGYÁZAT
NE érjen a levegő bemeneti nyílásához és a készülék alumínium ventilátorszárnyaihoz.
VIGYÁZAT
NE tegyen semmilyen tárgyat vagy készüléket a berendezés tetejére.NEM szabad a berendezésre felmászni, felülni vagy felállni.
MEGJEGYZÉS
A kültéri egységen végzett munkákat ajánlott száraz időjárási körülmények között végezni, hogy ne jusson víz az egységbe.
A vonatkozó jogszabályoknak megfelelően szükséges lehet jegyzőkönyvet biztosítani a termékhez, amely legalább a következő információkat tartalmazza: karbantartási információ, javítási munkák, tesztek eredményei, készenléti időszakok stb.
Emellett legalább a következő információt is biztosítani KELL a termék egy hozzáférhető részén:
Útmutatás a rendszer kikapcsolásához vészhelyzet eseténA tűzoltóság, rendőrség és kórház neve és címeA szerviz neve, címe, valamint éjjeli és nappali telefonszáma
Európában az EN378 tartalmazza a jegyzőkönyvre vonatkozó útmutatásokat.

2.2.2 Felszerelés helye

Az egység körül legyen elegendő tér a szereléshez és szellőzéshez.Bizonyosodjon meg róla, hogy a felszerelés helye elbírja az egység tömegét és
Válasszon megfelelően szellőző területet. NE fedje le a szellőzőnyílásokat.Győződjön meg róla, hogy az egység vízszintesen áll.
NEM szabad az egységet az alábbi helyeken felszerelni:
rezgését.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
Robbanásveszélyes környezetben.Elektromágneses hullámokat kibocsátó gépek közelében. Az elektromágneses
hullámok megzavarhatják a vezérlőrendszert, a berendezés hibáját okozva.
Tűzveszélyes környezetben, ahol fennáll a gyúlékony anyagok (például hígító vagy
üzemanyag) szivárgásának veszélye, illetve ahol szénszálak vagy gyúlékony por található.
Olyan térbe, ahol korrozív gázok (például kénsavas gáz) termelődik. A rézcsövek
és a forrasztások korróziója a hűtőközeg szivárgását okozhatja.
7
2 | Általános biztonsági óvintézkedések
Útmutatások R32 hűtőközeget használó berendezéshez
FIGYELMEZTETÉS: ENYHÉN TŰZVESZÉLYES ANYAG
Az egység belsejében keringő hűtőközeg kis mértékben tűzveszélyes.
FIGYELEM
TILOS átlyukasztani vagy égésnek kitenni.A jégmentesítő folyamat felgyorsításához vagy a berendezés tisztításhoz
KIZÁRÓLAG a gyártó által javasolt eszközöket használja.
Az R32 hűtőközeg nem tartalmaz szaganyagokat.
FIGYELEM
A mechanikai sérülések elkerülése érdekében a berendezést olyan helyiségben kell tárolni, ahol nem működik állandó gyújtóforrás (például: nyílt láng, működő gázkészülék vagy elektromos fűtőberendezés).
FIGYELEM
Ügyeljen rá, hogy a beszerelés, a szervizelés, a karbantartás és a javítás a Daikin utasításai szerint legyen elvégezve és megfeleljen a jogszbályi előírásoknak (pl. a gázkészülékek használatára vonatkozó országos előírásoknak), illetve arra, hogy a munkát erre jogosul személy végezze el.
FIGYELEM
Ha egy vagy több helyiség van összekötve az egységgel csőrendszeren keresztül, akkor ügyeljen az alábbiakra:
nem működhet állandó gyújtóforrás (például: nyílt láng, működő gázkészülék vagy
elektromos fűtőberendezés) a helyiségben, ha a padlószint alacsonyabb, mint a minimális alapterület A (m²) értéke;
a csővezetékbe tilos olyan segédberendezést telepíteni, amely potenciális
gyújtóforrás lehet (például: 700°C fölé melegedő felület vagy elektromos kapcsolóberendezés);
kizárólag a gyártó által jóváhagyott segédberendezések használhatók a
csőszereléshez;
a levegőbemenet ÉS kimenet közvetlenül, csővezetéken keresztül csatlakozzon
ugyanazon helyiséghez. NE használjon olyan tereket, mint pl. az álmennyezet a levegő be- vagy kimenetéhez.
MEGJEGYZÉS
Óvintézkedéseket kell tenni a hűtőközegcsöveket érő túlzott rezgés vagy pulzálás
elkerülése érdekében.
A védelmi berendezéseket, csöveket és szerelvényeket a lehető legnagyobb
mértékben védeni kell a káros környezeti hatásokkal szemben.
Hosszú csővezetékekenél gondoskodni kell a csövek tágulásának és
zsugorodásának kezeléséről.
A hűtőközeg-rendszereket úgy kell megtervezni és kialakítani, hogy minimálisra
csökkenjen a rendszert károsító hidraulikus sokk lehetősége.
A beltéri berendezést és csöveket biztonságosan kell felszerelni és elvezetni, hogy
a berendezés vagy a csövek ne repedhessenek meg véletlenül a bútorok mozgatása vagy felújítási munkák közben.
8
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
Beszerelési tér előírásai
Contains fluorinated greenhouse gases
2
1
1
1
2
2
kg
tCO2eq
1000
GWP × kg
=
=
+
kg
=
kg
=
GWP: xxx
R32
2 | Általános biztonsági óvintézkedések
VIGYÁZAT
SOHA NE használjon potenciális gyújtóforrást a hűtőközeg-szivárgás kereséséhez vagy azonosításához.
MEGJEGYZÉS
NE használja újra a már használt idomokat és a réz tömítőgyűrűket.A hűtőközeg-rendszer elemeinek csatlakoztatására használt idomokat úgy kell
felszerelni, hogy karbantartáshoz hozzáférhetők legyenek.
FIGYELEM
Ha az alkalmazás során R32 hűtőközeget használnak, akkor annak a helyiségnek az alapterülete, ahová a készülékeket beszerelik, üzemeltetik és tárolják, MINDENKÉPP nagyobb legyen, mint az alábbi táblázatban meghatározott minimális alapterület A (m2). Ez vonatkozik a következőkre:
Olyan beltéri egységek, melyekben nincs hűtőközeg-szivárgást észlelő szenzor,
olyan beltéri egységek esetében, melyekben van hűtőközeg-szivárgást észlelő szenzor, olvassa el a szerelési útmutatót
Beltérben felszerelt vagy tárolt kültéri egységek (pl.: télikert, garázs, gépterem)
MEGJEGYZÉS
A csővezetékeket védeni kell a mechanikai károsodástól.A lehető legkevesebb csővezetéket használja.
A minimális alapterület meghatározása
1 Határozza meg a rendszerbe töltött összes hűtőközeg mennyiségét (= gyári
hűtőközeg-mennyiség + utántöltött hűtőközeg mennyisége).
2 Válassza ki, melyik ábrát vagy táblázatot kívánja használni.
Beltéri egységekhez: Az egység mennyezetre erősített, falra szerelt vagy
padlóra állított készülék?
Beltérbe szerelt vagy tárolt kültéri egységek esetében ez a beszerelési
magasságtól függ:
Ha a beszerelési magasság… Akkor a következő ábrát vagy táblázatot
használja…
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
<1,8m Padlóra állított egységek
1,8≤x<2,2m Falra szerelt egységek
≥2,2m Mennyezetre erősített egységek
3 Az ábra vagy a táblázat segítségével határozza meg a minimális alapterületet.
9
2 | Általános biztonsági óvintézkedések
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
360
370
380
390
400
410
420
430
440
450
460
470
480
490
500
510
520
530
540
550
560
570
580
590
600
610
620
630
640
650
660
670
680
690
700
710
720
730
740
750
760
770
1.843
9.55
2.21.8
2.4 2.8 3.2 3.6 4 4.4 4.8 5.2 5.6 6 6.4 6.8 7.2 7.6 8 8.4 8.8 9.22
2.6 3 3.4 3.8 4.2
4.6
5 5.4 5.8 6.2 6.6 7 7.4 7.8 8.2 8.6 9 9.4
Floor-standing unit
(c)
Wall-mounted unit
(b)
Ceiling-mounted unit
(a)
m [kg]
A
min
[m
2
]
Ceiling-mounted
unit
(a)
4.6 13.4
4.6 180
4.8 14.6
4.8 196
5.0 15.8
5.0 213
≤1.842
5.2 17.1
≤1.842
5.2 230
1.843 3.64
5.4 18.5
1.843 28.9
5.4 248
2.0 3.95
5.6 19.9
2.0 34.0
5.6 267
2.2 4.34
5.8 21.3
2.2 41.2
5.8 286
2.4 4.74
6.0 22.8
2.4 49.0
6.0 306
2.6 5.13
6.2 24.3
2.6 57.5
6.2 327
2.8 5.53
6.4 25.9
2.8 66.7
6.4 349
3.0 5.92
6.6 27.6
3.0 76.6
6.6 371
3.2 6.48
6.8 29.3
3.2 87.2
6.8 394
3.4 7.32
7.0 31.0
3.4 98.4
7.0 417
3.6 8.20
7.2 32.8
3.6 110
7.2 441
3.8 9.14
7.4 34.7
3.8 123
7.4 466
4.0 10.1
7.6 36.6
4.0 136
7.6 492
4.2 11.2
7.8 38.5
4.2 150
7.8 518
4.4 12.3
4.4 165
m (kg)
A
min
(m2)
4.6 20.0
4.8 21.8
5.0 23.6
≤1.842
5.2 25.6
1.843 4.45
5.4 27.6
2.0 4.83
5.6 29.7
2.2 5.31
5.8 31.8
2.4 5.79
6.0 34.0
2.6 6.39
6.2 36.4
2.8 7.41
6.4 38.7
3.0 8.51
6.6 41.2
3.2 9.68
6.8 43.7
3.4 10.9
7.0 46.3
3.6 12.3
7.2 49.0
3.8 13.7
7.4 51.8
4.0 15.1
7.6 54.6
4.2 16.7
7.8 57.5
4.4 18.3
8 40.5
8.2 42.6
8.4 44.7
8.6 46.8
8.8 49.0 9 51.3
9.2 53.6
9.4 55.9
9.55 57.7
8 60.5
8.2 63.6
8.4 66.7
8.6 69.9
8.8 73.2 9 76.6
9.2 80.0
9.4 83.6
9.55 86.2
8 545
8.2 572
8.4 601
8.6 629
8.8 659 9 689
9.2 720
9.4 752
9.55 776
Wall-mounted
unit
(b)
m (kg)
A
min
(m2)
Floor-standing
unit
(c)
m (kg)
A
min
(m2)
10
m A rendszerbe töltött hűtőközeg teljes mennyisége
A
A minimális alapterület
min
(a) Ceiling-mounted unit (= Mennyezetre erősített egység) (b) Wall-mounted unit (= Falra szerelt egység)
(c) Floor-standing unit (= Padlóra állított egység)

2.2.3 Hűtőközeg — R410A vagy R32 esetében

Ha alkalmazható. További információkért tekintse meg alkalmazása szerelési kézikönyvét vagy szerelői referencia-útmutatóját.
MEGJEGYZÉS
Győződjön meg róla, hogy a hűtőközeget szállító csövek felszerelése a törvényi előírásoknak megfelelően történt-e. Európában az EN378 szabvány van érvényben.
MEGJEGYZÉS
Győződjön meg róla, hogy a helyszíni csövek és a csatlakozások NINCSENEK nyomásnak kitéve.
FIGYELEM
A tesztelés során SOHA ne helyezze a terméket a maximális engedélyezett nyomásnál (amely az egység adattábláján látható) nagyobb nyomás alá.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
2 | Általános biztonsági óvintézkedések
FIGYELEM
A hűtőfolyadék szivárgása esetén tegye meg a megfelelő óvintézkedéseket. Ha hűtőközeggáz-szivárgást észlel, azonnal szellőztesse ki a területet. Lehetséges kockázatok:
A túl magas hűtőközeg-koncentráció zárt térben oxigénhiányt okozhat.Ha a hűtőközeggáz tűzzel találkozik, mérgező gáz keletkezhet.
VESZÉLY: ROBBANÁSVESZÉLY
Leszivattyúzás – Hűtőközeg szivárgása. Ha szeretné leszivattyúzni a rendszert, és a
hűtőközeg szivárog a hűtőkörből:
NE használja az egység automatikus leszivattyúzás funkcióját, amellyel
rendszerből minden hűtőközeget a kültéri egységbe juttathat. Lehetséges következmény: A működő kompresszorba bejutó levegő öngyulladást és
robbanásr okoz.
Használjon külön begyűjtő rendszert, így az egység kompresszorának NEM kell
üzemelni.
FIGYELEM
A hűtőfolyadékot MINDIG gyűjtse össze. NE engedje, hogy az a környezetbe jusson. Vákuumszivattyúval szivattyúzza ki a felszerelést.
MEGJEGYZÉS
Miután minden csövet csatlakoztatott, ellenőrizze, hogy nincs-e gázszivárgás. Nitrogénnel hajtson végre gázszivárgás-ellenőrzést.
MEGJEGYZÉS
A kompresszor meghibásodásának elkerülése érdekében NE töltsön be több
hűtőközeget megadott mennyiségnél.
Ha a hűtőközegrendszert meg kell bontani, a hűtőközeg kezelését a vonatkozó
előírásoknak megfelelően KELL végezni.
FIGYELEM
Ellenőrizze, hogy nincs-e oxigén a rendszerben. A hűtőközeg feltöltése csak a szivárgásteszt és a vákuumszivattyús szárítás végrehajtása után végezhető el.
Lehetséges következmény: A kompresszor öngyulladása és felrobbanása a működő kompresszorba kerülő oxigén miatt.
Ha újratöltés szükséges, lásd az egységen az adattáblát. A tábláról leolvasható a
használható hűtőközeg típusa és a szükséges mennyiség.
Az egység gyárilag fel van töltve hűtőközeggel. A csőméretektől és -hosszaktól
függően egyes rendszerek további hűtőközeg-feltöltést igényelhetnek.
Csak a kifejezetten a rendszerben használatos hűtőközeghez megfelelő eszközök
használatával biztosítsa a nyomásellenállást, és akadályozza meg az idegen anyagok bejutását a rendszerbe.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
A hűtőközeg-folyadék feltöltése:
11
2 | Általános biztonsági óvintézkedések
Ha Ezután
Egy szifoncső van jelen
Töltéskor fordítsa felfelé a hengert.
(például: a hengeren a “folyadék feltöltéséhez szükséges szifonnal ellátva” felirat olvasható)
Egy szifoncső NINCS jelen Töltéskor fordítsa lefelé a hengert.
Lassan nyissa ki a hűtőközeghengereket.A hűtőközeget folyadék állapotban töltse fel. Ha gáz állapotban adja hozzá, az
megakadályozhatja a megfelelő működést.
VIGYÁZAT
Ha a hűtőközeg-feltöltési eljárással készen van, vagy azt megszakítja, akkor azonnal el kell zárni a hűtőközegtartály szelepét. Ha a szelep NEM zár azonnal, a megmaradó nyomás további hűtőközeg-utántöltést eredményezhet. Lehetséges következmény: Hibás hűtőközeg-mennyiség.

2.2.4 Elektromos

VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Kapcsoljon KI minden áramforrást, mielőtt eltávolítaná a kapcsolódoboz fedelét,
elektromos kábeleket csatlakoztatna, vagy megérintené az elektromos alkatrészeket.
Szüntesse meg a tápellátást, várjon legalább 10 percet, majd a szervizelés
megkezdése előtt mérje meg a feszültséget a főáramkör kondenzátorainak és elektromos alkatrészeinek kivezetésein. CSAK akkor érintse meg az elektromos alkatrészeket, ha a feszültség kisebb, mint 50 V (egyenáram). A kivezetések pontos helyét a huzalozási rajz segítségével határozhatja meg.
Vizes kézzel NE érintse meg az elektromos alkatrészeket.A szervizfedél eltávolítása után NE hagyja felügyelet nélkül az egységet.
FIGYELEM
Ha a termék gyárilag NEM tartalmazza, a rögzített vezetékekbe be KELL építeni egy főkapcsolót, vagy más olyan megszakítót, amellyel minden pólus csatlakozása bontható, amennyiben III-as kategóriájú túlfeszültség lépne fel.
12
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
2 | Általános biztonsági óvintézkedések
FIGYELEM
CSAK réz vezetékeket használjon.Győződjön meg róla, hogy a helyszíni vezetékek bekötése a törvényi előírásoknak
megfelelően történt-e.
A helyszíni huzalozási munkálatokat a termékhez mellékelt huzalozási rajz szerint
KELL végrehajtani.
NE gyömöszöljön összetekert kábeleket az egységbe, és ügyeljen arra, hogy a
kábelek NE érjenek a csövekhez vagy az éles szélekhez. Ellenőrizze, hogy a csatlakozásokra nem hat-e külső nyomás.
Gondoskodjon megfelelő földelésről. NE földelje az egységet gázcsövekhez,
vízcsövekhez, túlfeszültség-levezetőhöz, és ne kösse telefonföldelésre. A helytelen földelés áramütést eredményezhet.
Csak külön áramkört szabad használni. TILOS egy másik készülékkel közös
áramellátásról üzemeltetni.
Gondoskodjon róla, hogy be legyenek építve a szükséges biztosítékok és
megszakítók.
Mindenképpen szereljen fel földzárlat-megszakítót. Ennek elmulasztása
áramütéshez vagy tűzhöz vezethet.
A földzárlat-megszakító beszerelésekor ellenőrizze, hogy kompatibilis-e az
inverterrel (vagyis ellenáll-e a nagyfrekvenciás elektromos zajnak). Ha nem kompatibilis, a földzárlat-megszakító feleslegesen kioldhat.
VIGYÁZAT
A tápkábel csatlakoztatásakor: először a földelővezetéket kösse be, és csak azután
a tápvezetékeket.
A tápkábel leválasztásakor: először a tápvezetékeket kösse le, és csak azután a
földelővezetéket.
A tápkábel feszültségmentesítője és maga a csatlakozóblokk közötti tápvezetékek
hosszát úgy kell beállítani, hogy véletlen széthúzódáskor a tápvezetékek összeköttetése szakadjon meg előbb, és ne a földelővezetéké.
MEGJEGYZÉS
Óvintézkedések a tápkábelek fektetéséhez:
NE csatlakoztasson különböző vastagságú vezetékeket a tápfeszültség
csatlakozóblokkjára (a tápkábel lazasága abnormális hőmérsékletet eredményezhet).
Az azonos vastagságú vezetékeket a fenti ábrán látható módon csatlakoztassa.A huzalozáshoz használja a kijelölt tápkábelt, és biztonságosan csatlakoztassa,
majd rögzítse, hogy ne érhesse külső nyomás a csatlakozótáblát.
A csatlakozócsavarok meghúzásához használjon megfelelő csavarhúzót. A kis fejű
csavarhúzók kárt tehetnek a fejben, és lehetetlenné tehetik a megfelelő meghúzást.
A csatlakozócsavarok túl szoros meghúzása eltörheti őket.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
Az interferencia elkerülése érdekében a tápkábelek legyenek legalább 1 m távolságra a televízió- vagy rádiókészülékektől. A rádióadás hullámhosszától függően az 1m távolság kevés lehet.
13
2 | Általános biztonsági óvintézkedések
FIGYELEM
Az elektromos szerelési munka végén ellenőrizze, hogy az elektromos dobozban
minden elektromos alkatrész és csatlakozó jól csatlakozik-e.
Az egység elindítása előtt ellenőrizze, hogy alaposan lezárta-e a fedeleket.
MEGJEGYZÉS
Csak abban az esetben érvényes, ha a tápellátás háromfázisú, és a kompresszor BE/KI kapcsolóval indítható.
Ha fennáll az ellenfázis lehetősége egy pillanatnyi áramszünet után, és a termék működése közben megszűnik, majd helyreáll a tápellátás, csatlakoztasson helyben egy ellenfázisvédő áramkört. A termék ellenfázisban való működtetése a kompresszor és más alkatrészek meghibásodásához vezethet.
14
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
3 | A szerelőknek szóló biztonsági utasítások

3 A szerelőknek szóló biztonsági utasítások

A következő biztonsági utasításokat és szabályokat mindig be kell tartani.
Egység beszerelése (lásd
FIGYELEM
Az üzembe helyezést az üzembe helyező szakembernek kell elvégeznie, a felhasznált anyagoknak és a rendszer összeállításának meg kell felelnie a vonatkozó előírásoknak. Európában az EN378 szabvány van érvényben.
Beszerelési helyszín (lásd:
VIGYÁZAT
Ellenőrizze, hogy a felszerelés helye elbírja az egység súlyát. A hibás felszerelés
veszélyt okoz. Emellett vibráció és szokatlan működési zaj is jelentkezhet.
Hagyjon elégséges szerelési teret.NE szerelje fel az egységet úgy, hogy az a mennyezethez vagy a falhoz érjen, mivel
ez vibrációt okozhat.
FIGYELEM
A berendezést olyan helyiségben kell tárolni, ahol nem működik állandó gyújtóforrás (például: nyílt láng, működő gázkészülék vagy elektromos fűtőberendezés).
Az egység kinyitása (lásd:
"6Az egység felszerelése"[425]
)
"6.1A berendezés helyének előkészítése"[425]
"6.2Az egység felnyitása"[429]
)
)
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
A szervizfedél eltávolítása után NE hagyja felügyelet nélkül az egységet.
VESZÉLY: ÉGÉS/FORRÁZÁS VESZÉLYE
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Hűtőközegcsövek csatlakoztatása (lásd
csatlakoztatása"[436]
)
VIGYÁZAT
A szállítás során R32 hűtőközeggel töltött egységeken nem lehet helyszíni
forrasztást vagy hegesztést végezni.
A hűtőrendszer beszerelése közben, amennyiben legalább egy csatlakoztatott
rész hűtőközeggel van feltöltve, az alábbi követelményeket kell betartani: lakóterekben tilos oldható kötést létrehozni az R32 hűtőközeg csatlakozásai között, kivéve a beltéri egységet közvetlenül a csővezetékhez kapcsoló, helyszínen elkészített kötést. A beltéri egységet közvetlenül a csővezetékhez kapcsoló, helyszínen elkészített kötés lehet oldható típusú.
"7.2Hűtőközegcsövek
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
VIGYÁZAT
Csőszereléskor NE csatlakoztassa a leágazó csöveket és a kültéri egységet a beltéri egység csatlakoztatása nélkül olyan meggondolással, hogy a beltéri egységet majd később kötik rá.
15
3 | A szerelőknek szóló biztonsági utasítások
VIGYÁZAT
NE használjon ásványi olajat a peremezett részen.NE hasznosítsa újra a csöveket a korábbi felszerelésekből.Az élettartam biztosítása érdekében SOHA ne szereljen fel szárítót az R32
egységhez. A szárítóanyag elbomláskor a rendszert károsítaná.
VIGYÁZAT
Használja az egységhez rögzített hollandi anyát.A gázszivárgás elkerülése érdekében csak a perem belsejére vigyen fel hűtőközeg-
olajat. Használjon R32-höz való hűtőgépolajat.
NE használja újra az idomokat.
FIGYELEM
A kompresszor bekapcsolása előtt a hűtőközegcsöveket készre kell szerelni. Ha a hűtőközegcsövek még NINCSENEK bekötve és az elzárószelep nyitva van, akkor a kompresszor bekapcsolásakor levegőt szív a rendszer. Ez rendellenes nyomást hoz létre a hűtőkörben, és a berendezés károsodásához, sőt sérüléshez vezethet.
VIGYÁZAT
A nem tökéletes peremezés hűtőközeg-szivárgást okozhat.NE használja újra a csőtokokat. A hűtőközeggáz szivárgásának megelőzése
érdekében használjon új csőtokokat.
Csak az egységhez mellékelt hollandi anyákat használja. Más hollandi anyák
használata a hűtőközeggáz szivárgásához vezethet.
A hűtőközegcsövek ellenőrzése (
VESZÉLY: ROBBANÁSVESZÉLY
NE indítsa el az egységet, amíg vákuum alatt van.
Hűtőközeg feltöltése (lásd:
"8Hűtőközeg feltöltése"[447]
FIGYELMEZTETÉS: ENYHÉN TŰZVESZÉLYES ANYAG
Az egység belsejében keringő hűtőközeg kis mértékben tűzveszélyes.
FIGYELEM
Az egységben használt hűtőközeg kis mértékben tűzveszélyes, de általában NEM szokott szivárgás fellépni. Ha hűtőközeg-szivárgás miatt a szoba levegőjébe hűtőközeg kerül, és az nyílt lánggal vagy fűtőszállal érintkezik, az tüzet okozhat és ártalmas gázok keletkezhetnek.
Kapcsoljon ki minden tűzveszélyes fűtőkészüléket, szellőztesse ki a helyiséget, és lépjen kapcsolatba a klímaberendezést forgalmazó márkaképviselettel.
Az egységet addig NEM szabad ilyenkor használni, amíg azt a szakaszt, ahol a hűtőközeg szivárog, egy szakképzett szerelő meg nem javította.
"7.3A hűtőközegcsövek ellenőrzése"[444]
)
)
16
FIGYELEM
Az esetleg szivárgó hűtőközeg SOHA ne érjen a bőrhöz. Ellenkező esetben súlyos fagyási sérülés keletkezhet.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
3 | A szerelőknek szóló biztonsági utasítások
FIGYELEM
Csak R32 hűtőközeget használjon. Egyéb anyagok robbanást és balesetet
okozhatnak.
Az R32 fluorozott, üvegházhatású gázokat tartalmaz. Klímaváltozási potenciál
(GWP): 675. A gázokat NE engedje a légkörbe.
A hűtőközeg feltöltése közben MINDIG viseljen védőkesztyűt és védőszemüveget.
VIGYÁZAT
A kompresszor meghibásodásának elkerülése érdekében NE töltsön a megadott mennyiségnél több hűtőközeget.
Elektromos bekötések (lásd:
FIGYELEM
Az összes huzalozást képesített szakembernek KELL végeznie, és meg KELL felelnie
a vonatkozó jogszabályoknak.
Hozzon létre elektromos csatlakozókat a rögzített huzalozáshoz.A helyszínen beszerzett összes összetevőnek és összes elektromos szerkezetnek
meg KELL felelnie a vonatkozó jogszabályoknak.
FIGYELEM
Ha a tápellátásban hiányzó vagy rossz N-fázis van, akkor elképzelhető, hogy a
berendezés nem fog működni.
Alakítson ki megfelelő földelést. NE földelje az egységet gázcsövekhez,
vízcsövekhez, túlfeszültség-levezetőhöz, és ne kösse telefonföldelésre. A rossz földelés áramütést eredményezhet.
Szerelje be a szükséges biztosítékokat és megszakítókat.Rögzítse az elektromos huzalozást kábelrögzítőkkel úgy, hogy a kábel NE
érintkezzen éles felületekkel vagy a csövekkel, különösen a magas nyomású oldalon.
NE használjon műanyag ragasztószalaggal burkolt vezetékeket, sodort
vezetékeket, hosszabbítókábelt vagy csillag rendszerből származó csatlakozásokat. Ezek túlmelegedést, áramütést vagy tüzet okozhatnak.
NE szereljen be fázissiettető kondenzátort, mivel az egységben inverter található.
A fázissiettető kondenzátor csökkenti a teljesítményt és balesetet okozhat.
"9Elektromos felszerelés"[451]
)
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
FIGYELEM
MINDIG több eres kábelt használjon a tápellátás kábeleihez.
FIGYELEM
Használjon minden pólust megszakító kapcsolót, és hagyjon legalább 3 mm-t az érintkezési pontok között, ami teljes leválasztást biztosít III-as kategóriájú túlfeszültség esetében.
FIGYELEM
Ha a tápkábel sérült, a balesetek elkerülése érdekében a gyártóra, a márkaszervizre vagy egy hasonlóan képzett szakemberre KELL bízni a cseréjét.
17
3 | A szerelőknek szóló biztonsági utasítások
FIGYELEM
NE csatlakoztassa a tápvezetéket a beltéri egységhez. Ez áramütést vagy tüzet okozhat.
FIGYELEM
NE használjon helyben vásárolt elektromos alkatrészeket a terméken belül.NE válassza le az elvezetőszivattyú stb. tápellátását a csatlakozóblokkról. Ez
áramütést vagy tüzet okozhat.
FIGYELEM
Az összekötőkábelt tartsa távol a szigeteletlen rézcsövektől, mivel az ilyen csövek nagyon felforrósodhatnak.
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Az összes elektronikus alkatrész (a termisztorokat is beleértve) a tápellátásról kapja a feszültséget. Csupasz kézzel NE érintse meg.
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Szüntesse meg a tápellátást, várjon legalább 10 percet, majd a szervizelés megkezdése előtt mérje meg a feszültséget a főáramkör kondenzátorainak és elektromos alkatrészeinek kivezetésein. CSAK akkor érintse meg az elektromos alkatrészeket, ha a feszültség kisebb, mint 50 V (egyenáram). A kivezetések pontos helyét a huzalozási rajz segítségével határozhatja meg.
A kültéri egység felszerelésének befejezése (lásd
felszerelésének befejezése"[457]
)
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Gondoskodjon róla, hogy a rendszer megfelelően földelve legyen.Szervizelés előtt kapcsolja ki a tápellátást.Az áramellátás bekapcsolása előtt szerelje fel a kapcsolódoboz fedelét.
Karbantartás és szerelés (lásd:
"14Karbantartás és szerelés"[468]
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
VESZÉLY: ÉGÉS/FORRÁZÁS VESZÉLYE
FIGYELEM
Mielőtt a karbantartási vagy szerelési munkákat elkezdi, MINDIG ellenőrizze, hogy
az áramforráspanelen a hálózati megszakító le van-e kapcsolva, távolítsa el a biztosítékokat, vagy kapcsolja vissza az egység védőberendezéseit.
Az elektromos alkatrészekhez az áramtalanítás után még 10 percig NE érjen
hozzá, mert azok nagyfeszültséget adhatnak le.
Ügyeljen arra, hogy az elektromos doboz egyes részei felforrósodhatnak.Ügyeljen arra, hogy NE érintsen meg vezető részeket.Az egységet NEM szabad bő vízzel lemosni! Ez áramütést vagy tüzet okozhat.
"10A kültéri egység
)
18
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
3 | A szerelőknek szóló biztonsági utasítások
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Ezt a kompresszort csak földelt rendszerben szabad használni.A kompresszor szervizelése előtt kapcsolja ki az áramellátást.Szervizelés után szerelje vissza a kapcsolódoboz fedelét és szervizfedelet.
VIGYÁZAT
Mindig viseljen védőkesztyűt és védőszemüveget.
VESZÉLY: ROBBANÁSVESZÉLY
A kompresszor eltávolításához használjon csővágót.NE használjon keményforrasztó pisztolyt.Csak jóváhagyott hűtőközegeket és kenőanyagokat használjon.
VESZÉLY: ÉGÉS/FORRÁZÁS VESZÉLYE
Csupasz kézzel NE érintse meg a kompresszort.
Hibaelhárítás (lásd:
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
VESZÉLY: ÉGÉS/FORRÁZÁS VESZÉLYE
FIGYELEM
Mielőtt megvizsgálná a berendezés kapcsolódobozát, MINDIG ellenőrizze, hogy a
berendezés le van-e választva az áramellátásról. Kapcsolja ki a megfelelő megszakítót.
Ha egy biztonsági eszköz bekapcsolt, állítsa le az egységet, és derítse ki, hogy
miért aktiválódott a biztonsági eszköz, mielőtt azt kikapcsolná. A biztonsági eszközöket SOHA nem szabad kiiktatni vagy a gyári beállítástól eltérő értékre módosítani. Ha nem találja a probléma okát, lépjen kapcsolatba a forgalmazóval.
FIGYELEM
A hőmegszakító véletlen visszaállítása miatti balesetek elkerülése érdekében a berendezést TILOS külső kapcsolóeszközzel ellátni, például időzítővel, vagy olyan áramkörhöz csatlakoztatni, amelyet a közmű rendszeresen BE- és KIKAPCSOL.
"15Hibaelhárítás"[470]
)
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
VESZÉLY: ÁRAMÜTÉS VESZÉLYE
Ha az egység nem üzemel, a PCB panelen a LED-ek kikapcsolnak
energiatakarékossági céllal.
A csatlakozóblokk és a PCB akkor is áram alatt lehet, ha a LED-ek nem világítanak.
19
4 | A doboz bemutatása

4 A doboz bemutatása

4.1 Áttekintés: A doboz bemutatása

4.2 Kültéri egység

Ez a fejezet leírja, hogy mit kell tennie a kültéri és beltéri egységet tartalmazó dobozok helyszínre szállítását követően.
Tartsa szem előtt az alábbiakat:
Kiszállításkor az egység sértetlenségét ellenőrzni KELL. Bármilyen sérülést azonnal
jelezni KELL a szállítmányozó reklamációs ügyintézőjének.
A becsomagolt egységet vigye minél közelebb a végleges üzembe helyezési
helyhez, hogy megelőzze a szállítás során okozott sérüléseket.
Tervezze meg előre, hogy milyen útvonalon kerül az egység a felszerelési helyére.

4.2.1 A kültéri egység kicsomagolása

20
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03
4 | A doboz bemutatása
1
2
a
b c d e
i j
g h
f

4.2.2 Tartozékok eltávolítása a kültéri egységből

1 Emelje fel a kültéri egységet.
VIGYÁZAT
Csak a következőknek megfelelően kezelje a kültéri egységet:
2 Távolítsa el a tartozékokat a csomag aljáról.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
21
4 | A doboz bemutatása
a Kültéri egység szerelési kézikönyve b Általános biztonsági előírások
c Címke a fluortartalmú, üvegházhatást okozó gázokról d Fluorozott, üvegházhatású gázokra figyelmeztető többnyelvű címke e Kondenzvízgyűjtő
f Csavaros zacskó. A csavarok az elektromos vezetékek rögzítőszalagjának
felerősítésére szolgálnak.
g Leeresztősapka (kicsi) h Leeresztősapka (nagy)
i Szűkítő szerelvény j Energiacímke
22
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03

5 Az egység bemutatása

INFORMÁCIÓ
Csak 1 helyiséghez tartozó beltéri egység csatlakoztatása NEM lehetséges. Ügyeljen arra, hogy legalább 2 helyiséghez tartozó beltéri egységeket csatlakoztasson.
INFORMÁCIÓ
Az egységektől és/vagy a helyi beszerelési körülményektől függően szükség lehet az elektromos huzalok bekötésére a hűtőközeg betöltése előtt.
A multi alkalmazásban használt hibrid vagy DHW generátor 1 helyiség csatlakozásnak számít.
A megfelelő kombináció ismertetését a megfelelő táblázat, valamint a multi alkalmazásban használt hibrid vagy DHW generátor szerelési kézikönyve tartalmazza.
FIGYELMEZTETÉS: ENYHÉN TŰZVESZÉLYES ANYAG
Az egység belsejében keringő hűtőközeg kis mértékben tűzveszélyes.
5 | Az egység bemutatása
INFORMÁCIÓ
Az üzemi határértékeket a kültéri egység műszaki adatainak legújabb verziójában találja a Daikin honlapján (nyilvánosan hozzáférhető).

5.1 Áttekintés: Az egység bemutatása

A fejezet az alábbiakról ad tájékoztatást:

5.2 Azonosítás

MEGJEGYZÉS
Több készülék egyszerre történő üzembe helyezése vagy szervizelése esetén ügyeljen rá, hogy NE cserélje össze a különböző modellek szervizpaneljeit.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
23
5 | Az egység bemutatása

5.2.1 Azonosítási címke: Kültéri egység

Helye
24
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split sorozat
4P600463-1D – 2021.03

6 Az egység felszerelése

FIGYELEM
Az üzembe helyezést az üzembe helyező szakembernek kell elvégeznie, a felhasznált anyagoknak és a rendszer összeállításának meg kell felelnie a vonatkozó előírásoknak. Európában az EN378 szabvány van érvényben.

Ebben a fejezetben

6.1 A berendezés helyének előkészítése...................................................................................................................................... 25
6.1.1 A kültéri egység felszerelési helyére vonatkozó követelmények .......................................................................... 26
6.1.2 A kültéri egység felszerelési helyére vonatkozó további követelmények hideg éghajlat esetén......................... 28
6.2 Az egység felnyitása................................................................................................................................................................ 29
6.2.1 Az egység felnyitásáról ........................................................................................................................................... 29
6.2.2 A kültéri egység felnyitása ..................................................................................................................................... 29
6.3 A kültéri egység felszerelése .................................................................................................................................................. 29
6.3.1 A kültéri egység felszereléséről ............................................................................................................................. 29
6.3.2 Óvintézkedések a kültéri egység felszerelésénél .................................................................................................. 30
6.3.3 Az üzembe helyezés szerkezetének létrehozása ................................................................................................... 30
6.3.4 A kültéri egység felszerelése .................................................................................................................................. 31
6.3.5 A kondenzvíz-elvezetés biztosításához .................................................................................................................. 31
6.3.6 A kültéri egység ledőlésének megakadályozása .................................................................................................... 32
6 | Az egység felszerelése

6.1 A berendezés helyének előkészítése

NEM szabad az egységet gyakran használt helyen, például munkakörnyezetben elhelyezni. Olyan üzemekben (például őrlőmalmokban), ahol nagy mennyiségben keletkezik por, a berendezést KÖTELEZŐ lefedni.
Olyan szerelési helyet válasszon, ahol elegendő hely áll rendelkezésre az egység mozgatásához.
VIGYÁZAT
Ellenőrizze, hogy a felszerelés helye elbírja az egység súlyát. A hibás felszerelés
veszélyt okoz. Emellett vibráció és szokatlan működési zaj is jelentkezhet.
Hagyjon elégséges szerelési teret.NE szerelje fel az egységet úgy, hogy az a mennyezethez vagy a falhoz érjen, mivel
ez vibrációt okozhat.
Olyan helyet válasszon, ahol a kiáramló meleg/hideg levegő vagy a működés zaja
senkit NEM zavar.
Az egység körül legyen elegendő tér a szereléshez és szellőzéshez.Kerülje az olyan helyeket, ahol gyúlékony gáz szivároghat.A kép- vagy hanginterferencia megelőzése érdekében ügyeljen arra, hogy a
kommunikációs kábelek és a tápkábelek legalább 3méter távolságra legyenek a tévé- és rádiókészülékektől. A rádiójel hullámhosszától függően elképzelhető, hogy 3méter távolság sem elégséges.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
MEGJEGYZÉS
NE helyezzen tárgyakat beltéri és/vagy a kültéri egység alá, mert a tárgyak elázhatnak. Az egységen vagy a berendezés hűtőközegcsövein lecsapódott kondenzvíz, a levegőszűrő vagy a kondenzvíz-elvezetés eltömődése miatt víz csöpöghet a berendezésből, ami kárt tehet az alá tett tárgyban vagy beszennyezheti azokat.
25
6 | Az egység felszerelése
≤1200
>100
>100
>50
>350
>350
(mm)(mm)
a
b
b
a
>250
>300
(mm)

6.1.1 A kültéri egység felszerelési helyére vonatkozó követelmények

FIGYELEM
A berendezést olyan helyiségben kell tárolni, ahol nem működik állandó gyújtóforrás (például: nyílt láng, működő gázkészülék vagy elektromos fűtőberendezés).
INFORMÁCIÓ
A következő előírásokat is olvassa el:
"2Általános biztonsági óvintézkedések"[45]."7.1.3Hűtőközegcső hossza és szintkülönbsége"[435].
Vegye figyelembe a térközökkel kapcsolatos következő irányelveket:
a Levegőkimenet b Levegőbemenet
A mennyezettől legyen legalább 300mm hely a szereléshez és 250mm a vezetékek és csövek szervizeléséhez.
MEGJEGYZÉS
NE helyezze egymásra az egységeket.NE függessze a mennyezetre az egységet.
A kültéri egység levegőkimenetét érő erős szél (≥18 km/h) rövidzárlatot okoz (az elvezetett levegő beszívása miatt). Ez az alábbi következményekkel járhat:
a működési teherbírás csökkenése,gyakori fagyási gyorsulás a fűtési üzemmódban,a működés megszakadása az alacsony nyomás csökkenése vagy a magas nyomás
növekedése miatt;
26
a ventilátor károsodása (ha folyamatosan erős szél éri a ventilátort, előfordulhat,
hogy nagyon gyorsan kezd forogni, amíg el nem törik). Ha a levegőkimenet szélnek van kitéve, ajánlott egy terelőlemez felszerelése. Ajánlott úgy elhelyezni a kültéri egységet, hogy a levegőbemenet a falra nézzen, és
NE legyen közvetlenül kitéve a szélnek.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
4P600463-1D – 2021.03
R32 Split sorozat
6 | Az egység felszerelése
b
a
b
c
b
c
a
a Terelőlemez b Uralkodó szélirány
c Levegőkimenet
NEM szabad az egységet az alábbi helyeken felszerelni:
Zajérzékeny területeken (pl. Hálószoba közelében), így a működés hangja nem
lesz zavaró. Megjegyzés: Ha tényleges üzembe helyezési feltételek mellett méri a hangot, a
környezeti hang- és zajvisszaverődés miatt a mért érték magasabb lehet a műszaki adatok kézikönyvében, a Hangspektrumban említett hangnyomásszintnél.
INFORMÁCIÓ
A hangnyomásszint 70dBA alatti.
Ahol ásványolajpára, olajos permet vagy gőz lehet a levegőben. A műanyag
alkatrészek károsodhatnak és leeshetnek, vagy víz szivároghat.
NEM ajánlott az egységet az alábbi helyeken felszerelni, mert az az egység élettartamának csökkenéséhez vezethet:
Ahol a feszültség sokszor ingadozikGépjárművekre vagy hajókraAhol savas vagy lúgos gőz van
Tengerpart melletti beszerelés. Ügyeljen rá, hogy a kültéri egységet NE érje
közvetlenül sós levegő. Ez megelőzi a magas sótartalmú levegő okozta korróziót, ami az egység élettartamának csökkenéséhez vezethet.
A kültéri egységet a tengeri széltől védett helyre szerelje fel. Példa: Épület mögé.
Ha a kültéri egységet közvetlenül eléri a tengeri szél, szereljen fel szélfogót.
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM R32 Split sorozat 4P600463-1D – 2021.03
Szélfogó magassága≥1,5×kültéri egység magasságaA szélfogó felszerelésekor ügyeljen a szerelési tér előírásaira.
27
Loading...