Daewoo RL-411, RL-411R, RL-411GR, RL-412G, RL-412GR Service Manual

...
Service Manual
S/N No. :
FEB. 2004
DAEWOO DAT CO., LTD.
Mini Component System
Model:
RL-411(R)/412(R) RL-411G(R)/412G(R)
9CD8303100
RL-411/412
JAN. 2005
TIMER
MODE/BAND
CLOCK
M
A
S
T
E
R
V
O
L
U
M
E
FULL LOGIC OPERATION
FULL LOGIC OPERATION
PUSH
PUSH
DOWN UP
PRESET
HIGH QUALITY MICRO COMPONENT
FUNCTION
OPEN
SLEEP
REPEAT
PHONES
PUSH OPEN
PUSH OPEN
STAND BY
PAUSE CLEAR
TIMER
MODE/BAND
CLOCK
M
A
S
T
E
R
V
O
L
U
M
E
FULL LOGIC OPERATION
FULL LOGIC OPERATION
PUSH
PUSH
DOWN UP
HIGH QUALITY MICRO COMPONENT
FUNCTION
OPEN
SLEEP
REPEAT
PHONES
PUSH OPEN
PUSH OPEN
PAUSE CLEAR
RL-411G/412G
MICROCOMPONENTSYSTEM
SAFETY PRECAUTIONS ..................................................................................... 2~3
ADJUSTMENTS .................................................................................................... 4~5
EXPLODED VIEW AND PARTS LIST .................................................................. 6~7
WIRING DIAGRAM ................................................................................................ 8/9
BLOCK DIAGRAM .................................................................................................. 10
SCHEMATIC DIAGRAM .................................................................................... 11~15
!
MAIN................................................................................................................... 11
!
TUNER .............................................................................................................. 12
!
CD ..................................................................................................................... 13
!
MP3 CD ............................................................................................................. 14
!
FRONT .............................................................................................................. 15
!
POWER ............................................................................................................. 16
PCB PATTERN LAYOUT ...................................................................................17~25
!
MAIN ............................................................................................................ 17/18
!
CD ................................................................................................................ 19/20
!
MP3 CD ........................................................................................................ 21/22
!
FRONT ......................................................................................................... 23/24
!
POWER ........................................................................................................ 23/24
ELECTRICAL PART LIST
..........................................................................
Appendix
TableofContents
1
MICROCOMPONENTSYSTEM
RL-411(R)/412(R)
RL-411G(R)/412G(R)
SafetyPrecautions
2
WARNING
: TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
CAUTION :
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF UNINSULTED "DANGEROUS VOLTAGE"
WITHIN THE PRODUCT'S ENCLOSURE THAT MAY BE
SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE APPLIANCE.
CAUTION
TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS POLARIZED AC PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
LASER SAFETY
THIS UNIT EMPLOYS A LASER. ONLY QUALIFIED SERVICE PERSONNEL SHOULD REMOVE THE COVER OR ATTEMPT TO SERVICE THIS DEVICE DUE TO POSSIBLE EYE INJURY.
CAUTION :
USE OF ANY CONTROLS, ADJUSTMENTS, OR PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE.
CAUTION :
TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF
PLUG TO WIDE SLOT, FULLY INSERT.
ATTENTION :
POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPON­DANTE DE LA PRISE ET POUSSER JUSQU'AU FOND.
Important Safety Instructions
- All the safety and operating instructions should be read before
the appliance is operated.
- The safety and operating instructions should be retained for
future reference.
- All warnings on the appliance and in the operating instructions
should be adhered to.
- All operating and use instructions should be followed.
1. Water and Moisture - The appliance should not be used near
water - for example, near a bathtub, washbowl, kitchen sink,
laundry tub, in a wet basement, or near a swimming pool, and the like.
2. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by th manufacturer.
3. An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven
surfaces may cause the appliance and cart combination to overturn.
4. Wall or Ceiling Mounting - The appli-
ance should be mounted to a wall or
ceiling only as recommended by the manufacturer.
5. Ventilation - The appliance should be situated so that its location or position does not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installation, such as a bookcase or cabinet that may impede the flow of air
through the ventilation openings.
6. Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
7. Power Sources - The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance.
8. Grounding or Polarization - The precautions that should be taken so that the grounding or polarization means of an
appliance is not defeated.
9. Power - Cord Protection - Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
10.Protective Attachment Plug - If the appliance is equipped with an attachment plug having overload protection. This is a safety feature. See Instruction Manual for replacement or resetting of protective device. If replacement of the plug is required, be sure the service technician has used a replacement plug specified by the manufacturer that has the
same overload protection as the original plug.
11.Cleaning - The appliance should be cleaned only as recommended by the manufacturer.
12.Power Lines - An outdoor antenna should be located away from power lines.
CAUTION
RISK OF ELECTRIC SHOCKS
DO NOT OPEN
PORTABLE CART
Figure 2
SafetyPrecautions
3
13.Outdoor Antenna Grounding - If an outside antenna is connected to the receiver be sure the antenna system is
grounded so as to provide some protection against voltage surges and built-up static charges. Article 810 of the National Electrical Code, ANSI/NFPA 70, provides information with regard to proper grounding of the mast and supporting
structure, grounding of the lead-in wire to an antenna-dis charge unit, size of grounding conductors,location of antenna­discharge unit, connection to grounding electrodes and requirements for the grounding electrode. See Figure 1.
14.Non-use Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period
of time.
15.Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.
16.Damage Requiring Service - The appliance should be serviced by qualified service personnel when:
a) The power-supply cord or the plug has been damaged; or b) Objects have fallen, or liquid has been spilled into the
appliance; or c) The appliance has been exposed to rain; or
d) The appliance does not appear to operate normally or exhibits a marked change in performance; or e) The appliance has been dropped, or the enclosure
damaged.
17.Servicing - The user should not attempt to service the appliance beyond that described in the operating instructions.
All other servicing should be referred to qualified service personnel.
ANTENNA DISCHARGE UNIT (NEC SECTION 810-20)
ANTENNA LEAD IN WIRE
POWER SERVICE GROUNDING ELECTRODE SYSTEM (NEC ART 250 PART H)
GROUND CLAMP
ELECTRIC SERVICE EQUIPMENT
GROUNDING CONDUCTORS (NEC SECTION 810-21)
GROUND CLAMPS
EXAMPLE OF ANTENNA GROUNDING
NEC - NATIONAL ELECTRICAL CODE
Adjustments
4
Between TP202
and Ground
Adjust at the point that
TP202 voltage comes
from 5V to 0V
Adjustments
5
ExplodedViewandMechanicalPartsList
6
1
2
3
4
4
4
4
5
6
7
9
10
11-1
14
15
16
17
19
20
21
22
18
25
25
30
26
27
23
24
10
28
29
31
32-1
8
S1
S1
S1
S1
S1
S1
S6
S1
S1
S1
S1
S1
S1
S2
S8
S1
S8
S1
S3
S3
S3
S3
S4
S1
S1
S4
S4
S4
S4
S4
S4
S5
S5
S5
S5
P1
P2
P3
P4
P5
E2
E2
E3
E5
E6
E7
E1
30
E4
S4
S6
S6
S6
S1
E6
32-2
E5
HEATSINK(FOR5W)
S7
33
S8
S8
S2
S2
S2
S2
S2
S2
S1
S1
S1
S1
S1
32
11-2
S1
S1
S1
S1
AUTOSTOP DECK
AUTOREVERSE DECK
HEATSINK(FOR12.5W)
ExplodedView andMechanicalPartsList
7
WiringDiagram
8
!
RL-411(R)/412(R)
WiringDiagram
9
!
RL-411G(R)/412G(R)
BlockDiagram
10
SchematicDiagram
11
!
MAIN
SchematicDiagram
12
!
TUNER
SchematicDiagram
13
!
CD : RL-411(R)/412(R) Models only
Loading...
+ 30 hidden pages