Daewoo DWB-240RH-R, DWB-246RH-R, DWB-186RH-R, DWB-180RH-R User Manual

Service Manual
Window Type Room Air Conditioner
Model: DWB-180RH-R
DWB-186RH-R DWB-240RH-R DWB-246RH-R
DAEWOO ELECTRONICS CORP.
CONTENTS
2. Operation.....................................................................................................3
3. Wiring Diagram..........................................................................................18
4. Refrigerant Cycle.........................................................................................19
6. Circuit Diagram..........................................................................................21
7. Trouble Shooting Guide ...............................................................................24
8. Key Components of Electronic Circuit............................................................33
9. Disassembly Instructions ...............................................................................35
10. Exploded Diagram and Parts List...................................................................37
Contents
2
1. SPECIFICATIONS
ITEM
MODEL
DWB-180RH-R DWB-186RH-R DWB-240RH-R DWB-246RH-R
Power Source V/Ph/Hz AC 220-240V / 1 / 50Hz
Capacity
Btu/h 18,000 24,000
(Cooling & Heating)
Kcal/h 4,530 6,048
Dehumidification
l
/h 2.10 Power Cooling 2,240 2,750 Input(W) Heating 1,880 2,350 Running Cooling 10.40 13.10 Current(A) Heating 8.80 11.40
Type Recipro
Compressor
Model H2EB243ABKC H2EB283ABKC Capacitor 35µF/400VAC 40µF/370VAC Overload Protector Internal Type Model AM12DWD08(D.M.I) A2945CA011(D.M.I)
Fan Motor
Capacitor 7.5µF/400VAC 7.5µF/400VAC Indoor-Fan Blower Fan Outdoor-Fan Propeller Fan Control Capillary
Refrigerant (R-22) Capillary Tube ID ø1.4 x L800 x 2 ID ø 1.6 x L1000 x 2
Amount (g) 1,230 1,080
Dimensions (WxHxD)
Unit (mm) 660 x 430 x 705 Packing (mm) 711 x 525 x 757
Weight (Kg)
Net Weight 65 67 Gross Weight 69 71.5
Electrical Data
Conditions by JIS C9812
3
1
PARTS OF NAME AND FUNCTION
• DWB-180RH-R/DWB-240RH-R
2. OPERATION
NO PART NAME
1 AIR FILTER 2 GRILL FRONT 3 CABINET 4 BLADE VERTICAL
NO PART NAME
5 PANEL CONTROL 6 REMOTE CONTROLLER 7 BLADE HORIZENTAL 8 AIR VENT
6
3
1
2
7
4
8
5
4
• DWB-186RH-R / DWB-246RH-R
6
5
3
4
8
2
7
1
9
NO PART NAME
1 AIR FILTER 2 INLET GRILLE 3 CABINET 4 BLADE VERTICAL 5 PANEL CONTROL
NO PART NAME
6 REMOTE CONTROLLER 7 BLADE HORIZENTAL 8 AIR VENT 9 GRILLE FRONT
5
2
REMOTE CONTROLLER
REMOCON SIGNAL TRANSMITTER
TIMER/CANCEL
• Everytime you push this button, timer is set as follow. (1Hr2Hr3Hr4Hr→5Hr6Hr
8Hr10Hr12Hr16Hr→20Hr24HrCANCEL).
After the unit is timed, if this button is pushed, timer is canceled.
SLEEP
• SLEEP mode is selected as follow. (L1L2Cancel)
MODE
• Everytime you push this button, it is selected as follow. (COOLINGHEATING FANCOOLING)
AUTO SWING
• Everytime you push this
button, the auto swing mode is toggled.
TEMPERATURE
• It is the button to set the room in the desired room temp. The temp. can be set within a range from 16°C (60°F) to 32°C (90°F) by 1°C (1°F)
POWER ON/OFF
• To turn the unit ON, push this
button. To turn the unit OFF, push this button, again.
FAN SPEED
• Everytime you push this
button, it is selected as follow. (LowHighLow)
TIMER/
CANCEL
FAN SPEED
TEMP
SLEEP
MODE
AUTO
SWING
6
3
REMOTE CONTROLLER DISPLAY
Room Air-conditioner
FAN HEA TING COOLING
TEMP
TIMER
SENSOR
MODE POWER
FAN
SPEED
AUTO
SWING
TEMP./TIMER DISPLAY
It displays the temperature and the timer.
MODE DISPLAY
It displays the operating mode.
REMOCON SIGNAL RECEIVER
TEMPERATURE SET
It is the button to set the desired room temperature. The temperature can be set within a range from 16°C (60°F) to 32°C (90°F) by 1°C (1°F)
POWER ON/OFF SWITCH
To turn the unit ON, push this button. To turn the unit OFF, push this button again.
MODE SELECT
Everytime you push this button, It is selected as follow. (COOLINGHEATINGFANCOOLING)
FAN SPEED
Everytime you push this button, It is selected as follow. (LowHighLow)
AUTO SWING
Everytime you push this button, the auto swing mode is toggled. (When the fan stops in heating mode, the auto swing is also stopped and restarts when the fan goes run.)
DWB-180RH-R/DWB-240RH-R
CAUTION: When you turn off the unit with cooling mode, the Fan still work for about 10 seconds.
7
CAUTION: When you turn off the unit with cooling mode, the Fan still work for about 10 seconds.
DWB-186RH-R / DWB-246RH-R
Room Air-conditioner
FAN HEATING COOLING TIMER
MODE
POWER
FAN
SPEED
AUTO
SWING
TEMP
SENSOR
TEMP./TIMER DISPLAY
It displays the temperature and the timer.
MODE DISPLAY
It displays the operating mode.
REMOCON SIGNAL RECEIVER
TEMPERATURE SET
It is the button to set the desired room temperature. The temperature can be set within a range from 16°C (60°F) to 32°C (90°F) by 1°C (1°F)
POWER ON/OFF SWITCH
To turn the unit ON, push this button. To turn the unit OFF, push this button again.
MODE SELECT
Everytime you push this button, It is selected as follow. (COOLINGHEATINGFANCOOLING)
FAN SPEED
Everytime you push this button, It is selected as follow. (LowHighLow)
AUTO SWING
Everytime you push this button, the auto swing mode is toggled. (When the fan stops in heating mode, the auto swing is also stopped and restarts when the fan goes run.)
Replacing Batteries
8
Remove the COVER from the back of the remote controller.
Slide the cover according to the arrow direction
Insert two battaries.
Be sure that the (+) and (–) directions are correct
Be sure that both batteries are new
Re-attach the cover.
Slide it back into position
Do not use rechargeable batteries such batteries differ from standard dry cells in shape,
dimensions and performance.
Remove the batteries from the remote controller if the air conditioner is not going to be used for an extended length of time.
1 2 3
+
+
4
OPERATION INSTRUCTION
FUNCTION
POWER ON
Push POWER button
COOLING MODE
Push the MODE button until COOLING lamp lights.
HEATING MODE
Push the MODE button until HEATING lamp lights.
FAN Delay in heating mode
Change desired room temperature
Push the TEMP▲▼ button.
Change FAN SPEED
Push the FAN SPEED button.
OPERATION
1. The unit starts working. (It is delayed 30 seconds after main power source is supplied.) when running the unit again after once having stopped it, please wait for over 3 minutes.
2. Default mode is COOLING mode.
3. Default desired room temperature is 26°C (79°F). And fan speed is Low’.
1. Operating modes are changed as follows by pushing MODE button. (COOLINGHEATINGFAN COOLING)
2. The compressor and fan work.
3. In this mode you can change fan speed and desired temperature at any time.
4. SLEEP mode and ON/OFF TIMER can be selected. (By remocon button only)
1. Operating modes are changed as follows by pushing MODE button. (COOLINGHEATINGFAN COOLING)
2. The compressor and fan work.
3. In this mode you can change fan speed and desired temperature at any time.
4. SLEEP mode and ON/OFF TIMER can be selected. (By remocon button only)
There are 10 seconds time delay of the Fan Motor, when compressor is starts or stops.
1. The desired room temperature is changed within a range from 16°C (60°F) to 32°C (90°F) by 1°C.
1. FAN SPEED is changed as follows by pushing FAN SPEED button. (LOWHIGHLOW)
DISPLAY
1. Current room temperature is displayed.
2. COOLING lamp lights.
1. Current room temperature is displayed.
2. COOLING lamp lights.
1. Current room temperature is displayed.
2. HEATING lamp lights.
no display
1. It display desired room temperature when TEMP button is pushed.
3. After a few seconds, display is changed to current room temperature.
1. It displays as follows.
2. After a few seconds, display is changed to current room temperature.
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
LOW
HIGH
POWER
MODE
TEMP
MODE
TEMP
FAN
SPEED
FAN SPEED
or
or
MODE
MODE
or
or
or
9
DWB-180RH-R/DWB-240RH-R
10
FUNCTION
FAN MODE
Push the MODE button until FAN lamp lights.
ON/OFF AUTO SWING
Push the AUTO SWING button.
OFF TIMER
Push the TIMER/CANCEL button when unit is working. (REMOCON ONLY)
OPERATION
1. The Fan works only.
2. In this mode, the unit circulate room air.
3. Fan speed can be changed.
1. Auto swing function is toggled.
2. Air out-flow direction is changed automatically. (left/right direction)
3. While the fan stops in heating mode, the auto swing is also stopped and restarts when the fan goes run.
1. Timer is set to as follows by pushing TIMER/CANCEL button. (1hr2hr3hr4hr5hr→6hr8hr 10hr12hr16hr20hr 24hrcancel)
2. Unit is off after timer is over.
3. If you want to cancel timer, push this button again at any time.
DISPLAY
1. Current room temperature is displayed.
2. FAN lamp lights.
There is no change in display.
1. TIMER lamp lights.
2. Setting time is displayed.
3. After a few seconds, display is changed to current room temprature.
4. At this time, operation mode is displayed current setting mode.
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
AUTO
SWING
AUTO
SWING
TIMER/
CANCEL
MODE
MODE
or
or
FUNCTION
ON TIMER
Push the TIMER/CANCEL button when unit is off. (REMOCON ONLY)
SLEEP MODE
Push the SLEEP button in COOLING mode and HEATING MODE. (REMOCON ONLY)
Defrost the heat-exchanger of the outside (in heating mode)
OPERATION
1. Timer is changed to as follows by pushing TIMER/CANCEL button. (1hr2hr3hr4hr5hr→6hr8hr 10hr12hr16hr20hr 24hrcancel)
2. The unit starts working after set time is over. (by the operation mode and last setting temperature before the unit is off.)
3. If you want to cancel timer, push this button again at any time.
1. SLEEP MODE is changed as follows by pushing SLEEP button. (L1L2→Cancel) * L1 Mode
The unit is off after 4 hours. The desired Temp is increased 3°C
(5.4°F) for 4 hours in Cooling mode.
The desired temp is decreased 3°C
(5.4°F) for 4 hours in heating mode. Auto swing is selected. Fan speed is set to LOW’.
* L2 Mode
The unit work; as follow
Auto swing is selected. Fan speed is set to LOW’.
2. This mode can be selected in COOLING and HEATING mode only.
The unit runs 50 minutes The unit will start defrost function when the temperature of the heat exchanger of the outside arrived at the programed temperature. If not arrived at the programed temperature, the unit continuousiy runs the heating mode. While the defrost function is working the unit runs cooling cycle but the fan stops.
DISPLAY
1. TIMER lamp lights.
2. Setting time is displayed.
3. After a few seconds, display is changed to current room temperature.
1. L1 or L2 is displayed.
no display
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
TIMER/
CANCEL
ROOM TEMPERATURE DISPLAY.
Over 45°C or 100°F
5°C~45°C or 41°F~99°F
Below 5°C (41°F)
DISPLAY TEMPERATURE
11
SLEEP
12
FUNCTION
POWER ON
Push POWER button
COOLING MODE
Push the MODE button until COOLING lamp lights.
HEATING MODE
Push the MODE button until HEATING lamp lights.
FAN Delay in heating mode
Change desired room temperature
Push the TEMP▲▼ button.
Change FAN SPEED
Push the FAN SPEED button.
OPERATION
1. The unit starts working. (It is delayed 30 seconds after main power source is supplied.) when running the unit again after once having stopped it, please wait for over 3 minutes.
2. Default mode is COOLING mode.
3. Default desired room temperature is 26°C (79°F). And fan speed is LOW’.
1. Operating modes are changed as follows by pushing MODE button. (COOLINGHEATINGFAN COOLING)
2. The compressor and fan work.
3. In this mode you can change fan speed and desired temperature at any time.
4. SLEEP mode and ON/OFF TIMER can be selected. (By remocon button only)
1. Operating modes are changed as follows by pushing MODE button. (COOLINGHEATINGFAN COOLING)
2. The compressor and fan work.
3. In this mode you can change fan speed and desired temperature at any time.
4. SLEEP mode and ON/OFF TIMER can be selected. (By remocon button only)
There are 10 seconds time delay of the Fan Motor, when compressor is starts or stops.
1. The desired room temperature is changed within a range from 16°C (60°F) to 32°C (90°F) by 1°C.
1. FAN SPEED is changed as follows by pushing FAN SPEED button. (LOWHIGHLOW)
DISPLAY
1. Current room temperature is displayed.
2. COOLING lamp lights.
1. Current room temperature is displayed.
2. COOLING lamp lights.
1. Current room temperature is displayed.
2. HEATING lamp lights.
no display
1. It display desired room temperature when TEMP button is pushed.
3. After a few seconds, display is changed to current room temperature.
1. It displays as follows.
2. After a few seconds, display is changed to current room temperature.
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
HIGH
LOW
POWER
MODE
MODE
FAN
SPEED
TEMP
MODE
TEMP
FAN SPEED
or
or
MODE
or
or
or
DWB-186RH-R / DWB-246RH-R
13
FUNCTION
FAN MODE
Push the MODE button until FAN lamp lights.
ON/OFF AUTO SWING
Push the AUTO SWING button.
OFF TIMER
Push the TIMER/CANCEL button when unit is working. (REMOCON ONLY)
OPERATION
1. The Fan works only.
2. In this mode, the unit circulate room air.
3. Fan speed can be changed.
1. Auto swing function is toggled.
2. Air out-flow direction is changed automatically. (left/right direction)
3. While the fan stops in heating mode, the auto swing is also stopped and restarts when the fan goes run.
1. Timer is set to as follows by pushing TIMER/CANCEL button. (1hr2hr3hr4hr5hr→6hr8hr 10hr12hr16hr20hr 24hrcancel)
2. Unit is off after timer is over.
3. If you want to cancel timer, push this button again at any time.
DISPLAY
1. Current room temperature is displayed.
2. FAN lamp lights.
There is no change in display.
1. TIMER lamp lights.
2. Setting time is displayed.
3. After a few seconds, display is changed to current room temprature.
4. At this time, operation mode is displayed current setting mode.
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
FAN HEATING COOLING
ROOM TEMP DESIRED TEMP TIMER
AUTO
SWING
AUTO
SWING
TIMER/
CANCEL
MODE
MODE
or
or
Loading...
+ 30 hidden pages