Daewoo DWB-126CH User Manual

1
Please observe the following instructions.
1. Operate the Selector Switch to run or stop the unit.
- Do not use Main Power Switch or Auxiliary Power Switch to operate unit.
2. Do not stick anything into the air outlet or inlet.
- It is dangerous and it can cause injury or damage.
3. Avoid exposing your body directly to a continuous cool air - flow for long periods.
4. Do not pour water on the unit to clean it.
- It is dangerous and it can cause injury or damage. Never use solvents or harsh chemicals when cleaning the unit. When the air inlet grill and cabinet are dirty, wipe with luke - warm water (below 40°C or 104°F)
5. Avoid placing any obstacles near the inlet or outlet.
- If the inlet or outlet is blocked with any obstacle, it may cause damage to the unit.
6. Do not run or stop the unit frequently.
- If you run or stop the unit more then 4-5 times an hour, it can cause damage to the unit.
7. Wait at least 3 minutes before restarting the unit or in the case of power failure.
- If you turn on the unit within 3 minutes after power off, this can cause damage to the unit.
8. If the air conditioner is operated without an air filter, dust is not removed from the air, and resultant accumulation in the unit may lead to a failure.
- Do not forget to install the air filter.
9. The air filter should be cleaned at least once every two weeks.
10. When the unit is cleaned, set the Selector Switch at off position.
- And then unplug the power plug.
11. Never store gasoline or other flammable liquid near the air conditioner.
- It is very dangerous.
12. Do not force the controls on the front panel too much.
- It can cause damage the controls and the unit.
13. Set a comfortable temperature.
- Very low temperature setting considerably increase power consumption.
14. Be careful to keep room temperature comfortable.
- Avoid continuous direct air flow on you or a sick person while sleeping.
15. Do not remove the plug by pulling the power cord.
- Damage to the cord and may cause shock hazard.
16. This air-conditioner must used 20°C(min)~43°C(max) outdoor and 20°C(min)~32°C(max) indoor on the temperature range for the cooling operation. Also, this air-conditioner must used 2°C(min)~24°C(max) outdoor and 15°C(min)~27°C(max) indoor on the temperature range for the heating operation.
17. The appliance is not intended for use by young children or infirm persons without supervision.
18. Young children should be supervised to ensure that they do not play with the appliance.
PRECAUTIONS FOR PROPER USE OF AIR CONDITIONER
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지1
û
5
5. Find the Cabinet Drain
1) Remove the Grille Front from the unit.
2) Find the Cabinet Drain which is attached on rear side of the Grille Front”.
- If you dont remove it. the unit cannot be operated normally.
Inside of Grille Front
Remove the Cabinet Drain
6. Attach the Cabinet Drain
1) After front grille is removed, remove two screws located in both side of chassis.
2) Grip the handle of base pan and pull out the unit from chassis.
3) The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the air) is drained to the outside. In very humid weather, excessive condensate water removed from the air may cause some water to collect. To remove this excess water you can install the cabinet drain as detailed below.
1 Install the cabinet drain to the left corner of the cabinet with 3 screws. 2 Connect the drain hose to the outlet located at the bottom of the cabinet drain.
You can purchase the drain hose or tubing locally to satisfy your particular needs. (Drain hose is not supplied)
CABINET
SCREW
CABINET
DRAIN
DRAIN HOSE
3 Screws (M4x8)
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지5
7
WINDOW INSTALLATION
1. Determine Window Location. Determine a suitable location. The window where the Air Conditioner is to be installed should have enough strength to bear the weight of the Air Conditioner.
2. Measure units dimensions
3. Install the Mounting Angle at the Proper Location. Install the Air Conditioner using the Mounting Angle or other Hardware to be installed as shown in Fig.1 For proper drainage, Rear side of the unit should be inclined about 5mm lower.
4. Insert unit in window. With 2 people, lift unit and insert it into the window opening.
5. Finish opening Close up the gap between unit and window using the sponge or tape for insulation as shown in Fig. 1
* If through the wall installation is required, you may choose to consult an independent servicing Dealer.
CAUTION : Two people must work together to avoid personal injury.
Fig. 1 Mounting Angle Installation.
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지7
Close up the gap
5mm
Mounting Angle
unit
wall
OPERATING INSTRUCTIONS
9
FAN & COOLING CONTROL
The Fan Control Selector Switch has six positions. Choose one of the speed settings by rotating the fan control Selector Switch to the appropriate position.
OFF Select this setting for stop all operation of air conditioner FAN Select this setting for low speed air circulation without
cooling and heating.
LOW COOL Select this setting for cooling operation with LOW FAN. HIGH COOL Select this setting for cooling operation with HIGH FAN. LOW HEAT Select this setting for Heating operation with LOW FAN. HIGH HEAT Select this setting for Heation operation with HIGH FAN.
TEMPERATURE CONTROL
Choose a temperature settings by rotating the knob of thermostat to the appropriate position
The Thermostat automatically starts and stops cooling operation in order to keep the room temperature at a proper level, and this results in efficient use of power and economical cooling.
Turn clockwise for a cooler room temperature.
Turn counter-clockwise for a warmer room temperature.
HEATER LAMP
When the unit sets heating operation condition, the red lamp is lighted. When the frost settles on the heat exchanger of the outside, defrosting is made automatically and the red lamp is turned off. The unit may give a hiss and the fan motor stops for 1 to 10 minutes. This should not be regarded as a problem. After defrosting, the heating operation begins again.
NOTE
FOR MOST ECONOMICAL USE
1. Properly control the room temperature.
2. Avoid the unit being exposed to direct sunlight. Keep direct sunlight from the room.
3. Do not leave doors and windows open.
NOTE
Setting the control at the coldest extreme of the temperature range will not cool the room any faster. Usually the midpoint is a good starting position. If the room temperature is not satisfactory after a reasonable period of time, adjust the temperature control to a lower or higher setting.
CAUTION
When the air conditioner has been performing its cooling operation and is turned OFF or set to the FAN position, wait at least 3 minutes before resetting to the cooling operation.
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지9
SELECTOR
OFF
LOW
HEAT
HIGH HEAT
WARMER COOLER
FANFAN
LOW
COOL
HIGH
COOL
THERMOSTAT
WARMER COOLER
10
CHANGING AIR FLO W DIRECTION
Air flow deflectors divert air from center flow to left or right and up or down. Adjust deflectors for desired air flow pattern.
AIR FLO W AR OUND UNIT
Check in door grill and outdoor louvers for air flow obstructions. Do not block air flow to and from unit. The outdoor coil should be checked and periodically cleaned for debris that may collect and block unit air flow. If air flow is obstructed or deflected back into unit, the compressor may cycle on and off rapidly, causing early compressor failure.
DRAIN HOLE AND WATER DRIPPING OUTSIDE
Locate drain hole at the rear or on the bottom of unit. Water in base pan is picked up by the fan blade and thrown onto the warm outdoor coil where it evaporates. The air conditioner must be installed level or tilted slightly to the outside for proper water disposal. On exceptionally hot and humid days the air conditioner may permit excess water to pass thru rear drain hole or overflow. This should be considered normal.
DOOR VENT
The door vent for the room air ventilation is lever type. If the door vent lever moves to the left, then close the vent and moves to the rght, then open the vent.
GENERAL INFORMATION
Close Vent Open
Door Vent
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지10
12
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code.
USE OF EXTENSION CORD SET
Because of potential safety hazards under certain conditions, we strongly recommend against the use of an extension cord set. However, if you still elect to use an extension cord, it is absolutely necessary that it is earthed and the marked rating of the extension cord set should be 250V, 10A(Min.). The socket-outlet shall be installed near the equipment and shall be easily accessible.
REPLACEMENT OF SUPPLY FLEXIBLE CORD.
If the supply flexible cord is damaged, it must be replaced by the manufacturer or its service agent or similarly qualified person in order to avoid a hazard.
ELECTRICAL REQ UIREMENTS
WARNING :
To avoid death, personal injury or properly damage due to electrical shock, this unit must be grounded. Do not under any circumstances cut or remove the round grounding prong from the plug. Do not use a two prong adapter.
WARNING :
To avoid death, personal injury or properly damage due to electrical shock, do not use an extension cord or pinch the power cord. Do not remove the warning tag from the power cord.
CAUTION :
The appliance shall be installed in accordance with national wiring regulations.
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지12
13
BEFORE CALLING FOR SER VICE
When you find something wrong with your room air conditioner, please carefully check the following items. If you are unable to find the cause of trouble, contact your service dealer.
Difficulty
Air conditioner does not operate.
Little or no cooling
Noisy unit
Odors from unit
Water in base pan.
Possible Cause
No power to unit.
Compressor lockout on initial
plug in.
Dirty air filter
Is there anything blocking the
front?
Thermostat is not adjusted correctly.
Air conditioner undersized for application.
Loose parts
Weak building construction.
Water hitting fan.
Mold, mildew or algae formation
on wet surfaces.
Normal for operation in humid areas.
Suggested Solution
Set Fan Control Select to position other than "OFF".
Confirm power cord is plugged in.
Verify main power switch (main circuit breaker) or fuse of the unit is good.
Wait 3 to 4 minutes and restart the unit.
Clean air filter.
When blocked by curtains,
blinds, or furnitures, etc., the air flow is restricted and cooling performance is affected.
Adjust thermostat correctly.
Check with dealer to determine
proper unit capacity for application.
Tighten any loose parts.
Provide additional support.
Normal in high humidity.
Stop noise by allowing water to
drain from base fan through drain hole.
Place algaecide tablet in base pan
Remove water in base pan through drain hole.
Water in base pan is picked up by the fan blade and thrown onto the warm outdoor coil where water then evaporates.
DWB-122CH/126CH(호주향) 2002.4.22 3:17 PM 페이지13
담󰼿󰼿󰼿󰼿당󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿최󰼿인숙󰼿님󰼿󰼿
MODEL󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿󰼿DWB-126CH󰼿
TEL
69-8260
일󰼿󰼿󰼿󰼿정
제󰼿󰼿󰼿󰼿판 규󰼿󰼿󰼿󰼿격
MEMO
1차 2차 3차 4차 5차
05.󰼿08.󰼿29
6차 7차 8차 9차 10차 인쇄
Loading...