Daewoo DSB-123L User Manual

1
This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safe­ly and efficiently.
The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of suffi­cient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of im­portant operating and maintenance (servicing) in­structions in the literature accompanying the appli­ance.
Contact Installer if Necessary: The installation instructions are for a experienced installer. If you are not an experienced installer, contact a local installer for help. If you require help with service, contact your certified dealer or Daewoo Electronics for additional instructions.
If Unit is Installed Improperly: The manufacturer shall in no way be responsible for improper instal­lation or maintenance service, including failure to follow the instruc­tions in this manual.
Precautions When Wiring:
• Do not plug in the unit until all connections (tubing, drain hose, mounting, etc.) have been made and double-checked.
• High voltages are present in this unit and are very dangerous. Please refer to these instructions and diagrams when wiring. Improper connections or inadequate grounding can cause acciden­tal injury.
• This unit must be grounded in accordance with local electrical codes.
• Connect wires and pipes securely and tightly as loose connec­tions/wiring may cause overheating at connections and a possible fire hazard.
Precautions When Transporting:
• When transporting the unit, be very careful and get help as the units are very heavy. Be careful of sharp edges on the units also.
Precautions When Installing:
• When installing in a ceiling or wall, make sure the ceiling/wall is
strong enough to hold the unit’s weight. A frame may be necessary for added support.
• When installing in a room, make sure the tubes are well insulat­ed to protect the walls and furniture from sweating of the tubes.
• When installing in moist or uneven locations, make sure to use a raised level concrete pad or concrete blocks to provide a level, solid foundation for the outdoor unit; this prevents water damage and vibration.
• When installing in an area of high winds, make sure to securely anchor the outdoor unit down with bolts and a metal frame.
When Connecting Refrigerant Tubing:
• Keep all tubing as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten , making sure not to overtighten.
• Check the tubes carefully for leaks before starting the test run.
When Servicing:
• Make sure the power is off and the unit is unplugged before open­ing the unit to troubleshoot or repair electrical parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the sight after you finish, making sure no metal scraps and wiring are left in the unit.
• The Air conditioner shall be installed in accordance with the na-
tioned wiring regulation.
• The equipment fulfills the requirements in EN 61 000-3-11 and is
subject to conditional connection to the mains.
• It may be connected in consultation with the supply authority.
• The equipment may only be connected to a mains supply with a
system impedance of less than 0.3 ohm.
• The system impedance in the interface point may be obtained from the supply authority.
• If the mains supply has a higher system impedance, short voltage
dips may appear when the equipment is started or during opera­tion.
• This may influence or disturb the operation of other apparatuses, e.
g. flickering lamps, especially those connected to the same supply mains.
SAFETY INSTRUCTIONS
PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE IN­STALLING AND OPERATING THE UNIT:
IMPORTANT NOTES
• Adhere to all safety instructions and warnings throughout this manual.
• Read this manual carefully before installing or operating this unit to become familiar with its features and obtain the perfor­mance that will bring you continued enjoyment for many years.
• Follow each installation or repair step exactly as shown in the manual.
• Observe all local, state and national electric codes. Contact your local government for more information on electrical codes.
WARNING:
• ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL IN­JURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELEC­TRICIAN/INSTALLER SHOULD ATTEMPT TO WIRE THIS SYS­TEM.
• THE APPLIANCE IS NOT INTENDED FOR USE BY CHIL­DRENOR INFIRM PERSONS WITHOUT SUPERVISION.
• YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT DO NOT PLAY WITH THE APPLIANCE
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지1
2
Remark per EMC Directive 89/336/EEC To prevent flicker impressions during the start of the compressor (technical process) following installation conditions do apply.
1. The power connection for the air conditioner has to be done at the main power distribution. This distribution has to be of an low impedance. Normally the required impedance is reached at a 32A fusing point. Air conditioner fuse has to be 16A max!
2. No other equipment has to be connected to this power line.
3. For detailed installation acceptance please refer to your contract with the power supplier. If restrictions do apply for products like washing machines, air conditioners or electrical ovens.
4. For power details of the air conditioner refer to the rating plate of the product.
ROOM AIR CONDITIONER INSTRUCTION
Remarques relatives à la Directive EMC 89/336/CEE Pour eviter les phénormènes de scintillements(variation de lumière) et les parasites lors du démmarrage du compresseur, respecter les consignes d’installation décrites dans le mode d’emploi.
1. Le raccordement au secteur doit être-fait à l’aide d’un cable de section suffisante pour eviter tout échauffement de celui-ci et les chutes de tension (section recommandée 3x4mm
2
)
Cette ligne doit être protégée par un fusible ou disjoncteur de 16A
2. Aucun autre appareil ne doit être connecté sur cette ligne.
3. En cas de doute ou de difficulté contactez votre agence EDF. Vériflez qu’il nexiste pas de contraintes particulères pour l’instala­tion et l’utilisation de ce climatiseur.
4. Pour les caractéristiques de l’appareil référez vous à sa plaque signalétique.
CONSIGINES D’INSTALLATION RACCORDEMENT ELECTRIQUE
Comentario de la Directiva 89/336 EEC de la EMC. ára prevenir la sensación de golpeteo al arrancar el compresor(procesotécnico) debe aplicar las siguientes instrucciones de instalación
1. La conexión del aire acondicionado a la corriente eléctrica tiene que ser hecha a la distribución principal de energía. Esta distribución tiene que ser de baja impedancia. Normalmente, la impedancia requerida se alcanza en el punto de fusión de 32A. El fusible del aire acondicionado tiene que ser de 16A máximol.
2. Ningún otro equipo debe ser conectado a esta línea eléctrica.
3. Para normas detalladas de instalación por favor consulte el contrato con su suministador eléctrico, si tiene que aplicar restricciones para productos como lavadoras, aire acondicionado u homos eléctricos.
4. Para detalles sobre las alimentación eléctrica del aire acondicionado consulte la placa de datos del aparato.
INSTRUCCIONES DE INSTALA CION DEL AIRE ACONDICIONADO
Hinweis entsprechend EMV-Direktive 89/336/EEC Um einen “Flicker-Effekt” beim Anlauf des Kompressors (kurzzeitiger Spannungseinbruch, technischer Vorgang) zu vermeiden, muß für fol­gende installationsbedingungen gesorgt sein. (siche auch “Anweistingen zur installation.”)
1. Der Stromanschluß für die Klimpaanlage muß am Hauptverteller vorgenommen werden. Die Abzweigung muß mit niedriger Impedanz aus­geführt werden. Normalerweise ist die erforderliche niedrlge impedanz bei einem Sicherungsanschlußpunkt von 32A erreicht.
2. An die gleíche Netzleitung dürfen keine anderen Geráte angeschlossen sein.
3. Seitens der lokaten Energieversorgungsuntemehmen bestehen möglicherweise Einschránkungen für Produkte wie Waschmaschinen, Klimaanlagen, elektrische Öfen, etc. Für Einzelheiten zur Installation sehen Sie in Ihren Vertrag mit dem Energieversorgungsunternehmen.
4. Einzelheiten über die elektrischen Daten der Kimaanlage ersehen Sie auf dem Typenschild des Gerates.
ANWEISUNGEN ZUR INSTALLATION DER RAUM-KLIMAANLAGE
NOTA DELLA DIRETTIVA EMC 89/336 EEC Allo scopo di prevenire l’ effetto di FLICKER (variazione della luce) alla partenza del compressore, durante l’installazione seguire l punti sot­toelencatl.
1. Il collegamento dell’ alimentazione, del condizionatore, deve essere fatto con una linea preferenziale dlrettamente al quadro principale o contatore, e deve essere a bassa impedenza. Normalmente questa lmpedenza la si ottiene al punto di fusione di 32 A ; perll condizionatore usare un fusibile da 16 A max.
2. Nessun altro apparecchio elettrico dovra essere collegato alla stessa linea di alimentazione.
3. Per maggiori dettagll circa l’ accettazione dell’ installazione del condizionatore, fare riferimento al contratto con l’ Ente erogatore dell’ Energla Elettrica e verificare che non ci siano restrizioni in atto all’ Installazione di prodottl elettrici ad alto consumo.
4. Per le informazioni relative ai dati di allmentazlone del condizionatore, fare riferimento all’ etichetta posta sul prodotto.
INSTRUZIONI PER L’INSTALLAZIONE DEL CONDIZIONATORE
D’ARIA PER STANZE
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지2
CONTENTS
3
It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this unit.
Safety Instructions...........................................................................................................................................................1
Contents...........................................................................................................................................................................3
Location of Controls.........................................................................................................................................................4
Indoor Unit........................................................................................................................................................4
Outdoor Unit.....................................................................................................................................................4
Remote Controller............................................................................................................................................6
Remote Display................................................................................................................................................6
Operation.......................................................................................................................................................................10
Connecting the AC Cord................................................................................................................................10
Setting the Unit for Remote Operation...........................................................................................................10
How to Install Batteries ..................................................................................................................................11
Celsius to Fahrenheit Conversion Chart........................................................................................................11
To Set Auto Mode..........................................................................................................................................12
To Set Quick Mode ........................................................................................................................................12
To Set Cool Mode..........................................................................................................................................12
To Set Fan Only Mode...................................................................................................................................13
To Set Dehumidifier Mode.............................................................................................................................13
To Set Heat Mode (DSB-123LH/123PH Only)..............................................................................................14
To Select The Fan Direction..........................................................................................................................14
To Set Air-Cleaning (PLASMA) Mode (DSB-123PH)....................................................................................15
To Set Air-Cleaning (OXYGEN) Mode (DSB-123AH)...................................................................................16
To Set On Timer Mode ..................................................................................................................................17
To Set Off Timer Mode...................................................................................................................................17
To Set Unit to Sleep Mode.............................................................................................................................18
To Set Turbo/Mild Mode ................................................................................................................................18
Emergency Operation....................................................................................................................................18
Changing/Cleaning the Air Filters..................................................................................................................................19
Cleaning the Indoor Cover ............................................................................................................................................19
Care and Maintenanc....................................................................................................................................................20
Troubleshooting Guide..................................................................................................................................................21
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지3
4
LOCATION OF CONTROLS
Electrostatic Filter Electric Dust Collector (DSB-123PH Only)
Removes dust particles from the air.
Air Cleaning Filters
Removes dust and
prohibits germs.
Emergency/Remote Switch
Slide to select the desired position.
Indicators
Indicate the setting
Deodorizing Filter
Removes bad smells from the air.
Fan Direction
(Up/Down)
Indoor Cover
Power Plug
Cold Air
Air In
O N
O F
F
E N
T E
R
C A
N C
E L
T I
M
E R
R
E S
E T
F A
N D
I
R
.
F A
N S
P E E
D
M
O D
E S L
E E
P
O
N /O
F
F
T E
M
P .
LCD Remote Controller
Connection Cover
Remove cover to access the AC connection from this unit to the outdoor unit.
Sensor Wire (Heat Pump Model Only)
Remote
Sensor
COVER 02 HOSE
INDOOR UNIT
Connection Cover
Remove cover to access the AC connection to the indoor unit.
Service Valves
The indoor and outdoor units are connected by copper tubes which are connected here.
AIR IN
AIR OUT
OUTDOOR UNIT
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지4
5
INDOOR UNIT
Remote Control Signal Receiver
This place is the part to receive the signal if it re­ceives the signal, you can hear the signal beep. beep”.
There is a switch panel at inside of Front Panel.
At the time of operating, open the Front Panel.
Emergency switch can be used when the remote controller is lost or Testing.
Remote switch is usually used by remote controller.
Indoor Unit Display Switch Panel
ON (Red)
Lights when the
operation is going on.
Air clean
(Green)
Timer (Yellow)
Lights during the time reservation mode.
Quick (Red)
Lights during the time Quick Mode.
EMERGENCY
REMOCON
REMOCON
EMERGENCY
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지5
6
MODE
SLEEP
ON/OFF
TIMER
ENTER/ CANCEL
FAN SPEED
TURBO/MILD
Display
Display information
TURBO/MILD
Press to select super power operation (Turbo) mode.
TIMER ENTER/CANCEL Button
Press to enter a timer setting or to cancel timer setting
TIMER ON/OFF Button
Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)
MODE Button
Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier)
SLEEP Button
Press to set the unit for the sleep mode.
FAN DIR.
FAN DIR. Button
Press to select up/down direction for fan.
ON/OFF Button
Press to turn the unit on or off.
TEMPERATURE Buttons
Press to raise or lower the desired temperature.
FAN SPEED Button
Press to select the fan speed (High " ", Middle " ", Low " ", Natural).
COVER
Slide down to access most of the remote buttons. Slide down further to access the battery compartment.
AUTO
REMOTE CONTR OLLER
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier)
Light to indicate the mode selected.
TIMER Indicators (Include sleep)
Light to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicators
Light to indicate the temperature or time.
FAN DIRECTION Indicators
Light to indicate the fan direction.
NATURAL Indicator
Light to indicate the speeds simulating a breeze.
FAN Indicators
Light to indicate the fan speed.
AUTO
DSB-123L/DSB-F123L
REMOTE DISPLAY
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지6
7
DSB-123LH
REMOTE CONTR OLLER
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)
Light to indicate the mode selected.
TIMER Indicators (Include sleep)
Light to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicators
Light to indicate the temperature or time.
FAN DIRECTION Indicators
Light to indicate the fan direction.
NATURAL Indicator
Light to indicate the speeds simulating a breeze.
FAN Indicators
Light to indicate the fan speed.
AUTO
REMOTE DISPLAY
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지7
FAN SPEED Button
Press to select the fan speed (High " ", Middle " ", Low " ", Natural).
MODE Button
Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier/ Heat)
SLEEP Button
Press to set the unit for the sleep mode.
TIMER ON/OFF Button
Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)
TIMER ENTER/CANCEL Button
Press to enter a timer setting or to cancel timer setting
AUTO
MODE
SLEEP
ON/OFF
FAN SPEED
TIMER
ENTER/ CANCEL
FAN DIR.
TURBO/MILD
Display
Display information
ON/OFF Button
Press to turn the unit on or off.
TEMPERATURE Buttons
Press to raise or lower the desired temperature.
FAN DIR. Button
Press to select up/down direction for fan.
TURBO/MILD
Press to select super power operation (Turbo) mode.
COVER
Slide down to access most of the remote buttons. Slide down further to access the battery compartment.
8
DSB-123PH
REMOTE CONTR OLLER
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)
Light to indicate the mode selected.
TIMER Indicators (Include sleep)
Light to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicators
Light to indicate the temperature or time.
FAN DIRECTION Indicators
Light to indicate the fan direction.
NATURAL Indicator
Light to indicate the speeds simulating a breeze.
FAN Indicators
Light to indicate the fan speed.
PLASMA Indicator
Light to indicate the plasma mode.
AUTO
REMOTE DISPLAY
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지8
FAN SPEED Button
Press to select the fan speed (High " ", Middle " ", Low " ", Natural).
MODE Button
Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier/ Heat)
SLEEP Button
Press to set the unit for the sleep mode.
TIMER ON/OFF Button
Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)
TIMER ENTER/CANCEL Button
Press to enter a timer setting or to cancel timer setting
AUTO
MODE
FAN SPEED
SLEEP PLASMA
TIMER
ON/OFF
ENTER/ CANCEL
FAN DIR.
TURBO/MILD
Display
Display information
ON/OFF Button
Press to turn the unit on or off.
TEMPERATURE Buttons
Press to raise or lower the desired temperature.
FAN DIR. Button
Press to select up/down direction for fan.
PLASMA Button
Press to purify air.
TURBO/MILD
Press to select super power operation (Turbo) mode.
COVER
Slide down to access most of the remote buttons. Slide down further to access the battery compartment.
9
DSB-123AH
REMOTE CONTR OLLER
MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat)
Light to indicate the mode selected.
TIMER Indicators (Include sleep)
Light to indicate the timer function mode.
TEMPERATURE & RESERVATION TIME lndicators
Light to indicate the temperature or time.
FAN DIRECTION Indicators
Light to indicate the fan direction.
NATURAL Indicator
Light to indicate the speeds simulating a breeze.
FAN Indicators
Light to indicate the fan speed.
OXYGEN Indicator
Light to indicate the oxygen mode.
AUTO
REMOTE DISPLAY
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지9
FAN SPEED Button
Press to select the fan speed (High " ", Middle " ", Low " ", Natural).
MODE Button
Press to cycle through the modes (Auto/Quick/Cool/Fan/Dehumidifier/ Heat)
SLEEP Button
Press to set the unit for the sleep mode.
TIMER ON/OFF Button
Press to set the unit off or on time. (0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24hr)
TIMER ENTER/CANCEL Button
Press to enter a timer setting or to cancel timer setting
AUTO
MODE
FAN SPEED
SLEEP OXYGEN
TIMER
ON/OFF
ENTER/ CANCEL
FAN DIR.
TURBO/MILD
Display
Display information
ON/OFF Button
Press to turn the unit on or off.
TEMPERATURE Buttons
Press to raise or lower the desired temperature.
FAN DIR. Button
Press to select up/down direction for fan.
OXYGEN Button
Press to generate oxygen and clean polluted air.
TURBO/MILD
Press to select super power operation (Turbo) mode.
COVER
Slide down to access most of the remote buttons. Slide down further to access the battery compartment.
10
OPERATION
1. Insert the attached AC plug into a 2-pronged only 220V or 220V-240V AC outlet.
NOTES:
Never connect the AC line cord plug to other than the specified voltage (only 220V or 220-240V).
Use the attached power cord only.
If the outlet is a 3-pronged type or others, have an elec-
trician install a new outlet.
The new air conditioner system should be on its own 220V circuit. Contact your local electrical installer for in­stallation.
CONNECTING THE AC CORD
The outdoor unit is connected to the indoor unit through the AC connecting wire or connection cord. To connect the in­door unit to AC, follow the procedures below:
Plug into only 220V or 220V-240VAC Outlet.
SETTING THE UNIT FOR REMOTE OPERATION
After the unit is fully connected and plugged in, it can be turned on. To turn the unit on and set it for remote operation, follow the procedures below:
1. Open the indoor units cover and make sure the EMERGENCY/REMOTE switch is set to the REMOTE position; this will allow the unit to operate with the re­mote controller.
2. Press the ON/OFF button on the remote controller to turn on the unit. The On LED will light on the indoor unit and ON will light in the remote display. To select the various modes and settings, read the following pages.
THREE MINUTE COMPRESSOR DELAY
After turning the indoor unit on and setting it for air con­ditioner operation, the compressor (outdoor unit) will not come on for three minutes. This is a feature that will protect the compressor from damage due to quick start and stops.
INFORMATION:
1. The plug shall be connected to a ground socket outlet, and the interconnection cord shall be connected by an authorized electrician or specialist.
2. Information for interconnection cable:
3. Contact service man for the installation shall be in accordance with national wiring regulation
Items Specifications
Under 12K class AC 250V, 16A, H05VV-Fx1.0m
2
Above 12K class AC 250V, 16A, H05VV-Fx1.5m
2
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지10
AC Outlet and Plug
EMERGENCY/REMOTE Switch
REMOTE
EMERGENCY
11
CELSIUS TO FAHRENHEIT CONVERSION CHART
CELSIUS FAHRENHEIT
18 64.4 19 66.2 20 68 21 69.8 22 71.6 23 73.4 24 75.2 25 77
CELSIUS FAHRENHEIT
26 78.8 27 80.6 28 82.4 29 84.2 30 86 31 87.8 32 89.6
NOTES:
When operating the remote controller, make sure there are no obstructions between the remote controller and the re­mote sensor.
After a while the display goes blank to conserve battery power. To check the settings, press the ON/OFF button once.
1. Slide down the cover to access most of the remote buttons. Slide down further to access the bat­tery compartment.
2. Insert two AAA size Alkaline batteries fol­lowing the polarity dia­gram below.
TIMER
BATTERY PRECAUTIONS
The precautions below should be followed when using batteries in this device:
1. Use only the size and type of batteries specified.
2. Be sure to follow the correct polarity when installing the batteries as indicated in the battery compartment. Reversed batteries may cause damage to the device.
3. Do not mix different types of batteries together (e.g. Alkaline and Carbon-zinc) or old batteries with fresh ones.
4. If the device is not to be used for a long period of time, remove the batteries to prevent damage or injury from possible battery leakage.
5. Do not try to recharge batteries not intended to be recharged; they can overheat and rupture. (Follow battery manufac­turers directions).
HOW T O INST ALL BA TTERIES
To install the batteries, follow the procedures below:
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지11
ON/OFF
ENTER/ CANCEL
+
TURBO/MILD
+
12
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the remote display.
2. Make sure the AUTO indicator appears in the remote display. Using the TEMP.
or buttons, set the desired temperature. The desired temperature can be changed up or down 1 degree from the actual room temperature. For tempera­ture setting: 24~28°C
AUTO
3.Then the unit will automatically operate.
TO SET AUTO MODE
This unit will automatically operate the unit according to its surroundings while in the Auto mode. All you have to set is the desired temperature and it will control the fan, coolness and dehumidifier. Follow procedures below:
AUTO
TO SET QUICK MODE
To set this unit to cool at the highest power, follow the procedures below:
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the re­mote display.
2. Press the MODE button until the Quick indicator appears in the display.
3.
The unit will then start cooling the room at the highest power.
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the remote display.
2. Press the MODE button until the Cool indicator appears in the display.
3. Using the TEMP. or buttons, set the desired temperature. The desired tem­perature can be changed up to 32°C and down to 18°C.
4.To select the fan speed, press the FAN SPEED button until the desired speed appears in the display (see below).
FAN SPEEDS
AUTO The fan will automatically select the fan speed.
“” The fan will operate on low speed. “” The fan will operate on medium speed. “” The fan will operate on high speed.
NATURALThe fan will randomly cycle through the speeds
simulating a cool breeze.
TO SET COOL MODE
To set the unit to cool the room to a desired temperature, follow the procedures below:
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:56 PM 페이지12
AUTO
13
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the remote display.
2. Press the MODE button until the Fan indicator appears in the display. No allowance setting temperature
3. To select a fan speed, press the FAN SPEED button until the desired speed appears in the display (see be­low).
FAN SPEEDS
“” The fan will operate on low speed. “” The fan will operate on medium speed. “” The fan will operate on high speed.
NATURALThe fan will randomly cycle through the
speeds simulating a breeze.
NOTE:
If NATURAL is selected, the NATURAL indicator on the indoor unit will light.
TO SET FAN ONLY MODE
To operate only the fan so the unit will circulate the air, proceed as follows:
TO SET DEHUMIDIFIER MODE
Select this mode when there is high humidity. To select, follow the procedures below.
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the remote display.
2.Press the MODE button until the Dehumidifier indica­tor appears in the display.
3.
Using the TEMP. ▼or▲buttons, set the desired tem­perature. The desired temperature can be changed up to 32°C and down to 18°C.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:57 PM 페이지13
14
FAN SPEEDS
AUTO The fan will automatically select the fan
speed.
“” The fan will operate on low speed. “” The fan will operate on medium speed. “” The fan will operate on high speed.
NATURALThe fan will randomly cycle through the
speeds simulating a cool breeze.
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the remote display.
2.Press the MODE button until the Heat indicator appears in the display. In the heat mode, the fan direction or is further downward than that in the cool mode for the good circulation.
3. Using the TEMP. or buttons, set the desired temperature. The desired temperature can be changed up to 32°C and down to 18°C.
4. To select the fan speed, press the FAN SPEED button until the desired speed appears in the display (see below).
TO SET HEAT MODE (DSB-123LH/123PH/123AH ONLY)
To set the unit to heat the room to a desired temperature, follow the procedures below:
NOTE:
When the heating operation is started, hot air delivery might be delayed due to warming up period.
1. Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and ON will light in the remote display.
2.Press the MODE button to select the desired mode.
3.Press the FAN DIR. button to select the fan direction. See chart below for detailed information on each of the three settings.
TO SELECT THE FAN DIRECTION
Regardless of the mode the unit is set for, the fan direction can be changed so it moves up and down, left and right or both. Follow procedures below to set fan direction.
FAN DIR. First Press The air will flow up and down. Second Press Normal air direction.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:57 PM 페이지14
FAN DIR.
15
1. Air-cleaning mode is available while the unit is on auto mode, strong air-conditioning mode air-conditioning mode, ventilation mode, or dehumidification mode.
2.If you need air-conditioning and air-cleaning mode at the same time, press the PLASMA button while air-conditioning mode is on.
3. The unit keeps your rooms agreeable as the unit re­moves tiny impurities such as poisonous gas, small dust, cigarette smoke etc. which the other filters have not filtrated.
TO SET AIR-CLEANING (PLASMA) MODE (DSB-123PH)
Press PLASMA button to set Air-cleaning Mode
AUTO
AUTO
PLASMA
4. If you need air-cleaning only, press the PLASMA button while the unit is off. Air-cleaning mode may be on independently all the year round.
PLASMA
5. Press the PLASMA button if you cancel air-cleaning mode.
PLASMA
NOTES:
While
air-cleaning mode is on, there may be a fishlike smell due to a small amount of ozone, which is harmless to
health.
Whats the air-cleaning plasma?
With different air purity way using light, the polluted air (such as poisonous gas, small dust, cigarette smoke, germs etc.) that goes through the purity device with plasma is removed after being collected by ionization process and a separate antibiosis active carbon filter as a deodorization function purifies polluted air into fresh one in the forest.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:57 PM 페이지15
16
TO SET AIR-CLEANING (OXYGEN) MODE (DSB-123AH)
To operate oxygen generation mode, follow the procedures as below.
1.
Oxygen generation
mode is available while the unit is on auto mode, strong air-conditioning mode, air-conditioning mode, ventilation mode, or dehumidification mode.
2.If you need air-conditioning and
oxygen generation
mode at the same time, press the
OXYGEN
button
while air-conditioning mode is on.
3. The adequate oxygen give agreeable and healthful environments as the forest. Further, you need not open the door in order to ventilate room air.
OXYGEN
4. If you need oxygen generation only, press the OXYGEN button while the unit is off. Oxygen generation mode may be on independently all the year round.
OXYGEN
AUTO
5. Press the
OXYGEN
button if you cancel
air-cleaning mode.
OXYGEN
NOTES:
You must use oxygen generation function above 0 °C bacause of destructions of main parts. In the case of below 0°C, oxygen generation function is not operated and ventilation function supplies fresh outdoor air.
With using long time, the air filter function is degraded by various particles. Therefore, you can call A/S center and should check it usually every year.
Whats the oxygen generation?
The
adequate
oxygen (about 22%) helps us agreeable and healthful. Oxygen generation system applies to mem-
brane which can separate oxygen from the air by using the difference of physical and chemical molecular properties.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:57 PM 페이지16
AUTO
17
2.While the unit is off, press the TIMER ON button; the display will light waiting input for the timer, but the actual unit will not turn on.
3.Repeatedly press the TIMER ON button until the de­sired hour that you want the unit to turn on appears on the display. For example, if it is 1:00 P.M. and you want the unit to turn on at 4:00 P.M., select 3 hours.
4.
Press the ENTER button to input the setting into memory; the unit will beep, the TIMER indicator will light on the unit and the TIMER indi­cator on the remote will light to indi­cate the unit is in the timer mode.
1.Press the ON/OFF button of timer on the remote control to set the on timer mode, HOUR and ON on the remote display will be displayed and “TIMER” will be flicked. When you increase to press ON/OFF you will get desired time. Then, if pressing “ENTER/CANCEL” button, ON TIMER Mode will be started. If you want to stop ON TIMER Mode, please press ENTER/CANCEL again.
TO SET ON TIMER MODE
This unit can be set to automatically turn on after a predetermined amount of hours (up to 24) in the order of 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24.
5.
Place the remote controller so it is facing the unit. When the desired hour is reached, the unit will turn on to the selected mode.
NOTE : Press the ENTER button within 5 seconds
of selecting the desired time. If mote than 5 sec­onds elapse, steps 3 and 4 must be repeated.
1.Press the ON/OFF button of timer on the remote control to set the off timer mode, HOUR and OFF on the re­mote display will be displayed and “TIMER” will be flicked. When you increase to press “ON/OFF” you will get de­sired time. Then, if pressing ENTER/CANCEL button, OFF TIMER Mode will be started. If you want to stop OFF TIMER Mode, please press “ENTER/CANCEL” again.
TO SET OFF TIMER MODE
This unit can be set to automatically turn off after a predetermined amount of hours (up to 12) in the order of 0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10, 12, 16, 20, 24.
2.Press the TIMER OFF button once to enter the Timer screen.
3.Repeatedly press the TIMER OFF button until the de­sired hour that you want the unit to shut off appears on the display. For example, if it is 8:00 P.M. and you want the unit to turn off at 10:00 P.M., select 2 hours.
4.
Press the ENTER button to input the setting into memory; the unit will beep, the TIMER indicator will light on the unit and the TIMER indi­cator on the remote will light to indi­cate the unit is in the timer mode.
5. When the desired hour is reached, the unit will turn off.
NOTE: Press the ENTER button within 5 seconds
of selecting the desired time. If more than 5 sec­onds elapse, steps 3 and 4 must be repeated.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:57 PM 페이지17
AUTO
AUTO
AUTO
18
1.Press the ON/OFF button on the remote control to turn the unit on; the On LED will light on the indoor unit and “ON” will light in the remote display.
2. Press the MODE button to select the desired mode. Then, set the desired temperature using the TEMP. ▲ or ▼ buttons.
3.
Press the SLEEP button on the re­mote controller. The unit will then be in the sleep mode and will cool the room to the desired temperature. After a while the unit will increase the tem­perature again. This process will then repeat.
TO SET UNIT TO SLEEP MODE
When you are going to sleep, select this feature and the unit will cool off the room to the desired temperature and then increase that temperature throughout the night.
1. Open the indoor units cover and
press
the EMER-
GENCY/REMOTE button.
3.
To turn the unit off, press the
EMERGENCY/ RE-
MOTE button again.
2.The unit will then turn on and depending on the room temperature, it will select the cool or dehumidifier, fan speed and fan direction automatically.
EMERGENCY OPERATION
If the remote control is lost, broken or has no batteries, follow the procedures below:
TO CANCEL SLEEP MODE:
To cancel sleep mode, press the SLEEP button again; the SLEEP indicator will disappear in the dis­play.
1. The unit is fixed MILD mode on production.
2. Press the TURBO/MILD button for powerful operation.
3. When press the TURBO/MILD button one more time, it will be back to “MILD mode.
TO SET TURBO/MILD MODE
EMERGENCY/REMOTE Switch
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:58 PM 페이지18
AUTO
EMERGENCY/REMOTE Switch
19
CHANGING/CLEANING THE AIR FIL TERS
To change or clean the two black air filters, follow the procedures below:
1.Open the indoor unit’s cover and remove both black air filters by bending them slightly backward and the lifting out.
2. Remove the two small filters (Deodorizing and Electrostatic) from the indoor unit. After removing the connection terminal of electric dust collector, remove the electric dust collector. (Only DSB-123PH)
3. Examine the filters and determine if they need to be cleaned or replaced. To clean filters, use a vacuum and clean off dust. Use water and mild soap also if necessary.
5.Insert cleaned or new black filters back into the unit.
4. Insert cleaned or new small filters (Deodorizing and Electrostatic) back into the unit. After putting the connection ter­minal into electric dust collector, insert the electric dust colloctor into the unit. (Only DSB-123PH)
NOTES:
The filters should be changed every 6 months. If in a climate with cold winters, once a year is adequate.
After getting rid of vinyl bag in the filter (Deodorizing and Electrostatic), use it.
CLEANING THE INDOOR COVER
To clean the indoor cover, follow the procedures below:
1.Remove the left and right side to open the indoor cov­er upward by two hands.
NOTE:
Please remove or insert the indoor cover by two hands.
2.Pushing forward the indoor cover.
3.Remove the indoor cover.
3.(Remove it when cleaning.)
4.Cleaning the indoor cover.
NOTES:
Wipe the indoor cover with soft sponge or soft cloth.
When cleaning up it in the state of opening the indoor cover, wipe it with soft cloth.
After drying it completely in the shade, assemble it.
If you do not so, it may cause a trouble.
Reassembly of the indoor cover is reverse process of assembly
Caution : When you remove the electric dust collector,
you must remove the power plug.
(Only DSB-123PH)
(Only DSB-123PH)
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:58 PM 페이지19
CARE AND MAINTENANCE
20
Clean the casing and front of the indoor unit with a vacuum brush or wipe with a clean damp cloth.
NEVER USE Solvents, harsh chemicals or hot water to clean the unit.
Some metal edges on the unit are sharp. Be careful when cleaning or handling.
Internal parts in the outdoor unit may need cleaning or routine maintenance from time to time. Consult your local ser -
vice center for more details.
AFTER THE SEASON:
Operate the fan, then dry the indoor unit.
Shut off the indoor unit and then unplug it from the wall.
Clean the air filters.
Cover the outdoor unit with the supplied cover; this is very important to protect this unit.
BEFORE THE SEASON:
Make sure the air filters are clean.
Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions.
Make sure the unit is grounded. Consult a serviceman for help.
PRECAUTIONS:
Do not use this unit for animal or plant storage.
In a lightning or thunder storm, immediately unplug it from the wall.
warning
Make sure the AC cord is unplugged and the unit is off before cleaning.
Do not use water on the unit to clean it. This is a shock hazard and the unit can be damaged.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:58 PM 페이지20
TROUBLESHOOTING GUIDE
21
Before requesting service, please refer to the chart below for possible solutions:
SYMPTOMS POSSIBLE CAUSE POSSIBLE SOLUTIONS
No power . Power failure. Restore the power
Line voltage too low. Contact electrician to install new outlet. Unit is unplugged or not completely Insert plug all the way.
plugged in. Unit is off. Turn unit on. Batteries in remote are weak or dead. Replace remotes batteries. EMERGENCY/REMOTE Slide EMERGENCY/REMOTE
switch is not set to REMOTE. to REMOTE.
The compressor does When the unit is first plugged in Wait 3 minutes for the unit to operate. not turn on. and turned on, the compressor (no cool air) will delay turn on for 3 minutes.
If the unit is turned off and then Wait 3 minutes for the unit to operate. immediately back on, the compressor will delay for 3 minutes.
The air filter(s) is dirty or clogged. Clean or replace filter(s). Unit is located near a heat When locating unit for the first time,
source (heater, stove, etc.) make sure it is in a desirable location. A door or window is open. Shut door or window. There is an obstacle in front of Remove obstacle.
intake or indoor unit. Thermostat is set too high. Set thermostat lower.
Strange sounds occur. During operation, especially after This is normal.
turning it on or off, refrigerant flows inside the unit.
Strange smells occur. The fan is bringing out the The smell should go away shortly.
smells of the carpet, walls, etc.
No remote operation. Batteries are weak, dead or Replace batteries.
inserted improperly. Remote is out of range. Move closer to unit. Remote not aimed at sensor. Aim remote at sensor. There is an obstruction between Remove obstruction.
unit and remote.
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:58 PM 페이지21
MODEL #:
DSB-123L DSB-123LH DSB-123AH DSB-123PH DSB-F123L
OWNER'S MANUAL
SPLIT AIRCONDITIONING SYSTEM
S1
by Nemko
S/N : 3113909700
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:58 PM 페이지22
이왕구과장님/김상민님
TTEELL
MMOODDEELL
DSB-123L/123LH/AH/123AH/123PH/F123L
BBUUYYEERR
1차 02.12.16 6차 2차 7차
3차 8차 4차 9차 5차 10차
03.1.6(Han)-출력
MMEEMMOO
0033..11..1166--11pp
VVIISSIIOONN
전지현
TEL: 757-9340 FAX: 774-1039
VVIISSIIOONN CCRREEAATTIIVVEE,, IINNCC..
중구 남대문로 5가 526
대우재단빌딩 16층
ABOUT THIS MANUAL
ABOUT THIS MANUAL
DSB-123L/LH/AH/123PH/F123L 2003.3.4 1:58 PM 페이지23
Loading...