Daewoo DSB-122LH, DSB-122L User Manual

MODEL #:
DSB-122L/DSB-122LH
OWNER'S MANUAL
SPLIT AIRCONDITIONING SYSTEM
S1
DSB-122L/122LH(영어) 01.8.17 5:29 PM 페이지20
This air conditioner meets strict safety and operating standards. The installer of this unit must install or service this unit so it operates safely and efficiently.
The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulat­ed dangerous voltage within the product’s enclosure that may be of sufficient magni­tude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and main­tenance (servicing) instructions in the liter­ature accompanying the appliance.
Contact Installer if Necessary: The installation instructions are for a experienced in­staller. If you are not an experienced installer, contact a local installer for help. If you require help with service, contact your certified dealer or Daewoo Electronics for additional instructions.
If Unit is Installed Improperly: The manufacturer shall in no way be responsible for im­proper installation or maintenance service, including fail­ure to follow the instructions in this manual.
Precautions When Wiring:
• Do not plug in the unit until all connections (tubing, drain hose, mounting, etc.) have been made and dou­ble-checked.
• High voltages are present in this unit and are very dan­gerous. Please refer to these instructions and diagrams when wiring. Improper connections or inadequate grounding can cause accidental injury.
• This unit must be grounded in accordance with local electrical codes.
• Connect wires and pipes securely and tightly as loose connections/wiring may cause overheating at connec­tions and a possible fire hazard.
Precautions When Transporting:
• When transporting the unit, be very careful and get help as the units are very heavy. Be careful of sharp edges on the units also.
Precautions When Installing:
• When installing in a ceiling or wall, make sure the
ceiling/wall is strong enough to hold the unit’s weight. A frame may be necessary for added support.
• When installing in a room, make sure the tubes are well insulated to protect the walls and furniture from sweating of the tubes.
• When installing in moist or uneven locations, make sure to use a raised level concrete pad or concrete blocks to provide a level, solid foundation for the out­door unit; this prevents water damage and vibration.
• When installing in an area of high winds, make sure to securely anchor the outdoor unit down with bolts and a metal frame.
When Connecting Refrigerant Tubing:
• Keep all tubing as short as possible.
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten , making sure not to overtighten.
• Check the tubes carefully for leaks before starting the test run.
When Servicing:
• Make sure the power is off and the unit is unplugged before opening the unit to troubleshoot or repair electri­cal parts and wiring.
• Keep your fingers and clothing away from any moving parts.
• Clean up the sight after you finish, making sure no met­al scraps and wiring are left in the unit.
• The air conditioner shall be installed in accordance with the nationed wiring regulation.
SAFETY INSTRUCTIONS
1
PLEASE READ THE FOLLOWING SAFETY INSTRUCTIONS BEFORE IN­STALLING AND OPERATING THE UNIT:
IMPORTANT NOTES
• Adhere to all safety instructions and warnings throughout this manual.
• Read this manual carefully before installing or operat­ing this unit to become familiar with its features and obtain the performance that will bring you continued enjoyment for many years.
• Follow each installation or repair step exactly as shown in the manual.
• Observe all local, state and national electric codes. Contact your local government for more information on electrical codes.
WARNING:
• ELECTRICAL SHOCK CAN CAUSE SEVERE PER­SONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN/INSTALLER SHOULD ATTEMPT TO WIRE THIS SYSTEM.
• THE APPLIANCE IS NOT INTENDED FOR USE BY CHILDREN OR INFIRM PERSONS WITHOUT SU­PERVISION
• YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT DO NOT PLAY WITH THE APPLI­ANCE
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지1
CONTENTS
2
It is recommended that you read the Installation and Operating instructions fully before installing and/or operating this unit.
Safety Instructions...........................................................................................................................................................1
Contents...........................................................................................................................................................................2
Basic Accessories ...........................................................................................................................................................3
Optional Accessories.......................................................................................................................................................4
Location of Controls.........................................................................................................................................................5
Indoor Unit........................................................................................................................................................5
Outdoor Unit.....................................................................................................................................................5
Remote Controller............................................................................................................................................7
Remote Display................................................................................................................................................7
Operation.........................................................................................................................................................................9
Connecting the AC Cord..................................................................................................................................9
How to Store The Remote Controller...............................................................................................................9
Setting the Unit for Remote Operation.............................................................................................................9
How to Install Batteries ..................................................................................................................................10
Celsius to Fahrenheit Conversion Chart........................................................................................................10
To Set Auto Mode..........................................................................................................................................11
To Set Quick Mode ........................................................................................................................................11
To Set Cool Mode..........................................................................................................................................11
To Set Fan Only Mode...................................................................................................................................12
To Set Dehumidifier Mode.............................................................................................................................12
To Set Heat Mode(DSB-122LH Only) ...........................................................................................................13
To Select The Fan Direction..........................................................................................................................13
To Set On Timer Mode ..................................................................................................................................14
To Set Off Timer Mode...................................................................................................................................14
To Set Unit to Sleep Mode.............................................................................................................................15
To Set Turbo/Mild Mode ................................................................................................................................15
Emergency Operation....................................................................................................................................15
Changing/Cleaning the Air Filters..................................................................................................................................16
Cleaning the Indoor Cover ............................................................................................................................................16
Care and Maintenanc....................................................................................................................................................17
Troubleshooting Guide..................................................................................................................................................18
Specifications.................................................................................................................................................................19
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지2
This Installation section explains how and where to connect this new air conditioner. Please read make sure all acces­sories are included as shown below and read manual thoroughly. This Installation section is provided to assist the per­son knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar with this type of installation. Please contact a professional installer if necessary.
ACCESSORIES SUPPLIED WITH THE UNIT:
COPPER TUBING:
Copper tubing supplied is available at most dealers or A/C shops. Make sure the new copper tubing has the exact same specifications and diameter as the original copper tubing and is as short as possible.
BASIC A CCESSORIES
3
ON OFF ENTER CANCEL
TIMER RESET
SWING
FAN SPEED
MODE
SLEEP
ON/OFF
TEMP.
1
2
6
7
3
4 5
8
9
No. Description Qty.
1 Wall Bracket 1 2 Outdoor Unit Cover 1 3 Remote Controller 1 4 Battery 2 5 Foot Cushion 4
No. Description Qty.
6 Concrete Nails 5 7 Wall Bracket Screws 8 8 Deodorizing Filter 1 9 Electrostatic Filter 1
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지3
OPTIONAL A CCESSORIES
4
1
2
6
3
87
5
4
ACCESSORIES NOT SUPPLIED WITH THE UNIT:
No. Description Part No. Qty Material Size
1 Drain Hose Extension 3103200200 1 PVC ID19.6 X 2m PVC Pipe 2 Tape 2TQ1008000 1 PVC 80W X 0.1T X 3.5m 3 Copper Tubing Extension 3100002600 1 1/2", 1/4" Copper Tube 4 Insulator Plate 3103301000 1 F-US 225 X 120 X 8T 5 Putty 2221040001 1 80g 6 Connection Cord 3102797200 1 (1.5mm
2
X 6m X 3P) 7 Signal line Cord 3102796360 1 (1.5mm2X 6m X 2P) 8 Cap Wall 3100900600 2 P.P.
Complete Optional
3100019000 1
Accessories (1, 2, 3, 4, 5, 6, 7, 8)
(DSB-122LH Only)
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지4
5
LOCATION OF CONTROLS
Electrostatic Filter
Removes dust particles from the air.
Air Cleaning Filters
Removes dust and prohibits germs.
Emergency/Remote Switch
Slide to select the desired position.
Indicators
Indicate the setting
Sensor Wire (DSB-122LH Only)
Remote Controller Storage
Deodorizing Filter
Removes bad smells from the air.
Fan Direction
(Up/Down)
Indoor Cover
Power Plug
Cold Air
Air In
O
N
O F
F
E
N T
E R
C A
N C
E
L
T IM
E R
R
E S
E T
F A
N
D IR
.
F A
N S
P E
E
D
M
O D
E S L
E
E P
O
N /O
F
F
T E
M
P .
Remote Sensor
LCD Remote Controller
Connection Cover
Remove cover to access the AC connection from this unit to the outdoor unit.
INDOOR UNIT
Connection Cover
Remove cover to access the AC connection to the indoor unit.
Service Valves
The indoor and outdoor units are connected by copper tubes which are connected here.
AIR IN
AIR OUT
OUTDOOR UNIT
DSB-122L/122LH(영어) 01.8.17 5:27 PM 페이지5
Loading...
+ 14 hidden pages