5) Control Box Assembly..............................................................................60
1. SPECIFICATIONS
¡ DSB-090L
MODEL
ITEM
FunctionCooling
ClassT
Power AC 220-240V / 50Hz
Capacity W2,770
Btu/h 9,500
Dehumidificationl/h2.1
Running CurrentA4.5A
Electrical
Data
Compressor
Power InputW950W
Starting CurrentA24A
TypeRotary
Model RCB 090A001
Capacitor25µF/400VAC
DSB-090L
DivisionIndoor UnitOutdoor Unit
Fan
Refrigerant
(R-22)
Connection
Dimensions (W x H x D)mm925 x 285 x 194666 x 552 x 264
Net Weightkg9.734
TypeCross flow fanPropeller fan
Capacitor1.0µ F 400VAC1.8µF 400VAC
Motor Model NumberIC-8428DWKG7AIC-9630DWLC5A
ControlCapillary
Charge Q'tyg1,170
TypeFlare
OD
(Liquid/Suction)
in(mm)1/4 (6.35)1/2 (12.7)
2
¡ DSB-120L
MODEL
ITEM
FunctionCooling
ClassT
Power AC 220-240V / 50Hz
Capacity W3,507
Btu/h 12,000
Dehumidificationl/h2.1
Running CurrentA5.7A
Electrical
Data
Compressor
Power InputW1,250A
Starting CurrentA34A
TypeRotary
Model RCB 120A001
Capacitor25µF / 400VAC
DSB-120L
DivisionIndoor UnitOutdoor Unit
Fan
Refrigerant
(R-22)
Connection
Dimensions (W x H x D)mm925 x 285 x 194666 x 552 x 264
Net Weightkg9.734
TypeCross flow fanPropeller fan
Capacitor1.0µ F 400VAC3.5µF 400VAC
Motor Model NumberIC-8428DWKG7AIC-9430DWLC5A
ControlCapillary
Charge Q'tyg1,300
TypeFlare
OD
(Liquid/Suction)
in(mm)1/4 (6.35)1/2 (12.7)
3
¡ DSA-100L
MODEL
ITEM
FunctionCooling
ClassT
Power AC 208-230V / 60Hz
Capacity W2,923
Btu/h 10,000
Dehumidificationl/h2.1
Running CurrentA5.1A
Electrical
Data
Compressor
Power InputW1,115W
Starting CurrentA27A
TypeRotary
Model RCA 100A001
Capacitor25µF/400VAC
DSA-100L
DivisionIndoor UnitOutdoor Unit
Fan
Refrigerant
(R-22)
Connection
Dimensions (W x H x D)mm925 x 285 x 194666 x 552 x 264
Net Weightkg9.734
TypeCross flow fanPropeller fan
Capacitor1.0µ F 400VAC1.8µF 400VAC
Motor Model NumberIC-8428DWKG7AIC-9630DWLA6A
ControlCapillary
Charge Q'tyg1,150
TypeFlare
OD
(Liquid/Suction)
in(mm)1/4 (6.35)1/2 (12.7)
4
¡ DSA-120L
MODEL
ITEM
FunctionCooling
ClassT
Power AC 208-230V / 60Hz
Capacity W3,507
Btu/h 12,000
Dehumidificationl/h2.1
Running CurrentA5.7A
Electrical
Data
Compressor
Power InputW1,250W
Starting CurrentA34A
TypeRotary
Model RCA 120A001
Capacitor30µF / 400VAC
DSA-120L
DivisionIndoor UnitOutdoor Unit
Fan
Refrigerant
(R-22)
Connection
Dimensions (W x H x D)mm925 x 285 x 194666 x 552 x 264
Net Weightkg9.734
TypeCross flow fanPropeller fan
Capacitor1.0µ F 400VAC2.0µF 400VAC
Motor Model NumberIC-8428DWKG7AIC-9630DWLA6A
ControlCapillary
Charge Q'tyg1,200
TypeFlare
OD
(Liquid/Suction)
in(mm)1/4 (6.35)1/2 (12.7)
5
REMOCON
Filter - LFilter - R
Grille Insert
Frame Grille
Body
Plate Mounting
Connecting Pipe
Plate Mounting
406
194
285
925
2. OUTLINE AND DIMENSIONS
INDOOR UNIT
1
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
6
OUTDOOR UNIT
Cabinet SideHandleCabinet FrontFoot
264
334
Panel Top
Cabinet Back
552
572
Inlet
AIR
Inlet
Outlet
Foot Cushion
Service Valve
666
2
¡ DSB-090L/DSB-120L/DSA-100L/DSA-12OL
7
3. OPERATION
Power Plug
ON/OFF
TEMP.
AIR-CONDITIONER
REMOTE CONTROLLER
Electrostatic Filter
(option)
Deodorizing Filter
(option)
Air Inlet
Antibacterial
Filter
Air OutletFan Direction
(Up, Down)
Remote Controller
Remote
Controller
Receiver
Lamp
PARTS OF NAME AND FUNCTION
1
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
Indoor Unit
8
EMERGENCYREMOTE
ONAIR CLEAN FAN DELAYTIMER
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
Indoor Unit DisplaySwitch Panel
Remote Control Signal Receiver
This place is the part to receive the signal if it
receive the signal, you can hear the signal
"beep, beep".
§ There is a switch panel at inside of Front
Panel. At the time of operating, open the
Front Panel.
Emergency switch can be used when the remote
controller is lost or testing.
ON (Red)
Lights when the
operation is
going on.
Timer (Green)
Lights during the time
reservation mode.
Remote switch is usally used by Remote
Controller.
Air clean (Green)
FAN DELAY (Green)
Lights during the time
Fan delay mode
9
AIR
Air Inlet (side Back)
Air Outlet
Connection
Wire
Connecting
Pipe
Drain Hose
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
Outdoor Unit
NOTE:
How to remove Top Panel
1. Loosen the screw at left and right side.
2. Push the three parts op Front and Back sides like figure orderly.
3. Unhook the locking parts of Top Panel.
The front locking parts
FRONT SIDEBACK SIDE
The back locking parts
10
LMH
TEMP.
ON/OFF
FAN DIR.MODE
FAN SPEED
ONOFFENTER
CANCEL
SLEEP
TIMER
RESET
TEMP.
A
SLEEP
TIMER
AUTO
NATURAL
HOUR
OFFON
AIR CONDITIONER
REMOTE CONTROLLER
2
REMOTE CONTROLLER
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
Name of Each Button
FAN DIR. Button
Press to select the fan
direction.
FAN SPEED Button
Press to select the fan speed
(Auto, L, M, H or Natural).
TIMER ON Button
Press to set the on time.
TIMER OFF Button
Press to set the off time.
Display
Displays information pertaining to the
unit.
The option is LEFT/RIGHT direction.
Temperature Buttons
Press to raise or lower the desired
temperature.
ON/OFF Button
Press to turn the unit on or off.
MODE Button
Press to cycle through the modes
(Auto/Cool/Fan/Dehumidifier).
SLEEP Button
Press to set the unit for the sleep mode.
RESET Button
Press to reset settings to their default
positions.
CANCEL Button
Press to cancel Timer settings.
Cover
Slide down to access most
of the remote buttons.
Slide down further to
access the battery
compartment.
ENTER Button
Press to enter a Timer setting.
11
LMH
TEMP.
A
SLEEP
TIMER
AUTO
NATURAL
HOUR
OFFON
REMOTE CONTROLLER DISPLAY
ON/OFF
TEMP.
ON/OFF
TEMP.
3
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
M ODE Indicators (Auto/Cool/Fan/Dehumidifier)
Lights to indicate the mode selected.
TRANSMITTER Icon
Lights to indicate
a signal is being sent.
TEMP. Indicator
Lights to indicate the
temperature is being set.
SLEEP Indicator
Lights to indicate the
unit is in sleep mode.
NA TURAL Indicator
Lights to indicate the
temperature is being set.
FAN Indicators
Lights to indicate
the fan speed.
Replacing Batteries
Temperature
Indicator
Lights to indicate the
temperature
TIMER Indicators
Lights to indicate the timer
function modes.
FAN DIRECTION
Indicators
Lights to indicate the fan
direction.
The option LEFT/RIGHT
dirction
Open the cover after
pressing the arrow
1
direction and pulling out.
Put the drycell by §]§^
direction.
2
12
3
Close the cover after
pushing into arrow
direction.
DESCRIPTION OF FUNCTIONS
Unit ON
Unit OFF
SET Time
HOUR
ON
OFF
Unit ON
Unit OFF
SET Time
HOUR
ON
OFF
COMP (ON)
(COOLING)
Desired temperature
COMP (OFF)
-1˚C
Temperature
4
OFF-Timer
If you set time in OFF-Timer Mode, the unit will stop at the set time.
ON-Timer
If you set time in ON-Timer Mode, the unit will run at the set time.
Control of Room Temperature
(1) Range of setting temperature: 18~32°C
(2) Setting temperature: Operating temperature of compressor
¡Room temperatrue
< setting temperature
(
Compressor OFF
Room temperature
> setting temperafure
(
Compressor ON
Buzzer
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep –" or "beep,
beep".
(1) In the case of receiving ON/OFF signal-"beep""beep"
(2) And so on-"beep"
13
00.51.0HOUR
SET TIME
Desired
Difference
desired temperature
between room
temperature (°C)
0.5°C
0.5°C
0.5°C
Temperature
Fan Speed (Indoor Unit)
0
L
M
H
+1°C+2°C+3°C(R.T-D.T)
(D.T)
(1) Motor speed (Super high speed, high speed, normal speed, low speed, ultra low speed).
(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)
(3) Relation of operating mode between fan speed.
FAN ONLYCOOL
Super highXXXXSuper high
HHHXHX
MMMXMX
LLLXLX
AutoXAutoAutoAutoX
NaturalNaturalNaturalXNaturalX
DEHUMI-
DIFICATION
AUTO AUTO II
(4) Automatic Operation
If the unit is set in 'AUTO' mode, the unit operates automatically according to the room temperature to keep
the room temperature comfortable.
(COOLING)
R.T=Room temperafure
D.T=Desired temperafure
Sleep Mode
(1) When you are going to sleep, select sleep switch and the unit controls the r oom to the desir ed temperature.
(The unit will not operate after 4 hour)
(2) For changing the temperature.
14
Emergency Operation
0°C7°C
Compressor and
Outdoor Fan
OFF
OFF
ON
Set Speed
Indoor Fan
(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can be
used to run the unit.
(2) The setting conditions of Emergency operation are as follows.
• Operation mode: AUTO
• Preset temperature: 26°C
• Discharge Air Direction: SWING (up and down)
• Fan speed: AUTO
¡Y ou cannot operate with remote contr oller.
Frost Prevention of Indoor Unit
When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coil
temperature is lower than 0°C at the end of 10 minutes of continuous compressor operation from the start, the
microcomputer of the unit stops the compressor to protect the unit from the frost. The contr ol procedur e for
indoor coil freeze protection.
1) The compressor and outdoor fan turn off.
2) Indoor fan operates according to user set speed.
3) The normal operation returns when the indoor coil temperature is higher than 7°C or equal to 7°C.
(Indoor coil temperature)
3 min. Time Delay of Compressor
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial
power up.
Indoor Fan Motor Starting
When indoor fan motor is on, it always starts at normal speed and then it operates desired speed.
15
Auto Mode I
-101
°C
OFF
ON
(Room temperature Desired temperature)
H
M
L
0+1+2+3
°C
(Room temerature Desired temperature)
(1) When the room temperature is higher than 28 ºC (Cooling Mode)
! Compressor and lndoor Fan
@ The fan will automatically operate as following Figure
Dehumidification Mode
!Desired temperature < Room temperature
Outdoor Fan, Compressor : ON
Indoor Fan : Low speed
@ Desired temperature ¡ˆRoom temperature
Compressor : 3 min/ON, 5 min/OFF
Indoor Fan : 3 min 30 second/ON, 4 min 30 second/OFF
Fan Speed : Ultra low speed
# Room temperature ¡´18°C
Compressor : OFF
Indoor Fan : 1 min/ON, 7 min/OFF
Air Discharge Direction(only remocon operation)
The air discharge direction procedur e is below.
Fixed Up/DownFixed
Up/DownFixed Left/Right
16
Auto Mode II(Powerful Cooling)
-1
OFF
ON
(Room temperature-18˚C)
01
!Fan Speed: Super high speed
@ Air dischar ge direction: Fixed
# Set temperature: 18°C (Fixed)
$ Compr essor and Outdoor Fan
The air discharge direction procedur e is below
Fixed Up/DownFixed
Up/Down Fixed Left/Right
ƒRThe option is LEFT/RIGHT direction.
Self-Diagnostic Function
The control will contain diagnostic test to verify the integrity of the system.
(1) Error Code Display Pattern
!ON LAMP: ON (Red) LED ON/OFF
@ Error Code
ERROR CODE
1 Romm air thermistor, connector
2 Indoor coil thermistor, connector
0.5
second
3
4
DIDSPLAY PATTENERROR CONTENTS
8 seconds
0.5 second
8 seconds
0.5 second
8 seconds
0.5 second
Compressor, Electrical parts of
comp. Gas leak
8 seconds
0.5 second
Motor, Conector, P.C.B.
17
4. WIRING DIAGRAM
FAN MOTOR
BRN
H
S
CAPACITOR
YEL
COMPRESSOR
RED
BRN
FAN
HERM
C
BRN
BLK
BLU
YELLOW/GREEN
R
C
R
OUTDOOR
TERMINAL
BLOCK
BLU
YELLOW/GREEN
BROWN
INDOOR
TERMINAL
BLOCK
BLU
YEL/GRN
BRN
BLU
BRN
YEL/GRN
BLU
POWER CORD
PCB TRANS
LED PCB
1
1
2
3
COMP
1 21 2123456 71 23 412 3
BLK
BLK
LED
LED
BLU
RED
GRN
YEL
GRY
BRN
BLK
BLK
BLK
BLK
BLK
YEL
RED
BLU
I/D SENSOR
SELECT S/W
HOLE
SENSOR
123
ORG
GRY
YEL
R
S
C
12 3
èXée
FAN MOTOR
FAN MOTOR
CAPACITOR
SWING
MOTOR
1212345
BLU
ORG
RED
BLK
YEL
RED
PINK
BLU
ORG
YEL
OUTDOOR UNITINDOOR UNIT
Y
L
Y
L
1
1
2
3
COMP.
RELAY
NY
POWER CORD
BRN
YEL/GRN
BLU
BLU
BRN
YEL/GRN
BLU
DOMESTIC
EXPORT
L1L
¡ DSB-090L/DSB-120L/DSA-100L/DSA-120L
18