Daewoo C-TD1212SPX, C-TD1212LPX Service Manual

Page 1
DRUM WASHING MACHINE
SERVICE MANUAL
1. WHAT IS DRUM WASHING MACHINE? ......................................1
2. WASHER SPECIFICATION
3. PARTS LIST BY ASS'Y
4. CONTROL PART FUNCTION SPECIFICATION
5. ELECTRONIC FIELD PARTS LIST AND SPECIFICATION
6. WIRING DIAGRAM
.....................................................................33
..........................................................3
.................................................................4
.......32
C-TD1212SPX(SM)(영).indd 1 2013-04-30 오전 11:10:53
Page 2
1. WHAT IS DRUM WASHING MACHINE?
1. Drum Washing Machine
Water consumption is reduced by using the power of the laundry falling (free-fall) created when rotating
the drum. With temperature control system, this drum washing machine saves energy and improves
washing performance at the same time.
2. Key Features
Waist Care Designed by the waist, and the most comfortable
angle eject into the laundry is convenient and easy to manipulate.
Star Drum Using Star Drum is able to show users higher
Washing Performance and Minimal damage of laundry, water consumption.
Luxury Audio Dial Using the advanced Audio Dial is luxury design of
exterior.
DD inverter motor The direct-drive type of which motor is directly
connected to drum without an interim clutch, significantly reduces noise and vibration.
Self-Cleaning Course of Drum. Enables the machine to do Self-Cleaning of Drum.
Digital Condensing Dry System. Condensing Dry System with saveing energy.
1
C-TD1212SPX(SM)(영).indd 1 2013-04-30 오전 11:10:53
Page 3
3. Power System
LAUNDRY
Pump Drainage
• DD Control: Direct drive type of direct connection between drum and motor
• Rotation by powerful high-performance BLDC motor
BLDC
2
C-TD1212SPX(SM)(영).indd 2 2013-04-30 오전 11:10:53
Page 4
2. WASHER SPECIFICATION
1. Product Specification
MODEL NO. C-TD1212LPX C-TD1212SPX
Power Source AC220V / 60Hz AC127V / 60Hz
Power Consumption 2100W, 9.5A 1350W, 10.6A
Dimension (W×H× D) 632×954×752(mm)
Maximum mass of textile(Kg) 10.5Kg
Unit Weight (net/gross) 80 Kg / 84 Kg
Standard Water Consumption 63 ℓ
Operating Water Pressure 0.3kgf/cm² ~ 8kgf/cm² (0.03MPa ~ 0.8MPa)
33
C-TD1212SPX(SM)(영).indd 3 2013-04-30 오전 11:10:55
Page 5
3. PARTS LIST BY ASS'Y
1. PANEL AS
A18
A16
A17
A24
A23
A19
A21
A20
A23
A02
A03
A05
A04
A06
A07
A09
A08
A11
A12
A14
A22
4
C-TD1212SPX(SM)(영).indd 4 2013-04-30 오전 11:11:00
A10
A13
A15
Page 6
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
A01 PANEL F AS PRPAFRTD00 ELISMARY 10.5KG 1
A02 PANEL F 36142T5600 ABS 1
A03 DECO PANEL F 36116DX600 ABS 1
A04 WINDOW DISPLAY 3615515500 TR-ABS 1
A05 WINDOW COURSE 3615515800 MILKEY 1
A06 DECO WINDOW 3611DX200 ABS 1
A07 BUTTON FUNCTION L 361665100 ABS 1
A08 BUTTON POWER 3616651200 ABS 1
A09 BUTTO FUNCTION R 3616651100
A10 HOLDER LED FUNCTION 3613067900 HIPS 1
A11 CUSTOM LED 361305A000 A
A12 BUTTON OPTION 3616651300 ABS 1
A13 HOLDER LED COURSE 3613068000 HIPS 1
A14 PCB AS PRPSSWLE10 FR-1 1.6T 1
A15 CASE PCB F 36111T5300 HIPS 1
A16 KNOB CHILD LOCK 3613410000 ABS 1
A17 LEVER SLIDING 3617805600 POM 1
A18 KNOB DIAL M 3613410500 ABS 1
ABS
BS 1
127V AND 220V AVAILDABLE
1
A19 KNOB DIAL I 3613410600 ABS 1
A20 KNOB DIAL O 3613410400 ABS 1
A21 GASKET BUTTON 3612321500
A22 SCREW TAPPING 7122401211 T2S TRS 4X12 MFZN 12
A23 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
A24 SCREW TAPPING 7122401608 T2S TRS 4X18 SUS304 2
SPONGE, Ø32, T=8.0, HOLE=9X9
5
1
C-TD1212SPX(SM)(영).indd 5 2013-04-30 오전 11:11:00
Page 7
2. INLET BOX AS
B11
B01
B10
B02
B06
B09
B07
B03
B04
B05
B08
B08
6
C-TD1212SPX(SM)(영).indd 6 2013-04-30 오전 11:11:02
Page 8
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
B01 INLET BOX AS
B02 NOZZLE *T 3618113800 PP 1
B03 NOZZLE *U 3618113700 PP 1
B04 INLET BOX 3617513100 PP 1
B05 HOSE INLET 3613279100 EPDM, C-TD1212LPX 1
B06 LINK CHILD LOCK 3617805500 ABS 1
B07 SPRING LEVER 3615120500 ABS 1
B08 CLAMP AS 3611203200 ID=61, WIRE+GUIDE+BOLT+GS 2
B09 CLAMP HOSE 3611205800 100H, ID=13.8 W=10.0, 0.9T 4
B10 HOSE WATER SUPPLY
B11 VALVE INLET
B12 CLAMP HOSE 3611205800 100H, ID=13.8 W=10.0 0.9T 4
3617513110 C-TD1212 220/60 COLD 1
3617513111 C-TD1212 127/60 COLD 1
3613270900 EPDM ID9.5,OD14.5, M 1
3613270900 EPDM ID9.5,OD14.5, M 1
3615415070
3615415050
100~130V,3WAY,RINSE
GUIDE,PP/BRACKET
220~240V,3WAY,RINSE
GUIDE,PP/BRACKET
1
1
7
C-TD1212SPX(SM)(영).indd 7 2013-04-30 오전 11:11:02
Page 9
3. CABINET F ASSY
C01
C09
C10
C14
C02
C13
C03
C04
C05
C06
C14
C12
C07
C08
C11
8
C-TD1212SPX(SM)(영).indd 8 2013-04-30 오전 11:11:05
Page 10
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
C01 CABINET FRONT AS
C02 CABINET *F 361081WN00 SGCC 0.8T 1
C03 CABINET F UPPER 361081WP00 SGCC 1.2T 1
C04 PLATE HINGE SUPPORT 3614548400 SPG 1.2T 1
C05 SWITCH DOOR LOCK
C06 SWITCH DOOR (DRYER) 3619047710 UL,DRUM,SPE110F-1D7,DC5V 5mA 1
C07 CABINET F LOWER 361081WQ00 SGCC 1.2T 1
C08 CASE PUMP 36111T5100 PP 1
C09 COVER PUMP 3611434100 ABS 1
C10 DOOR AS 36117YDX00 D-LD1452, CR-GILDING 1
C11 SCREW TAPPING 7122401408 T2 TRS 4X14 SUS,STS 6 6 POINTS
C12 SCREW TAPPING 7122401408 T2S TRS 4X14 SUS, STS 2
C13 SCREW TAPPING 3616029950 TTS"S" HEX F/L 4*8 2
C14 SCREW TAPPING 3616029950 TTS"S" HEX F/L 4*8 2
PRCAFRTD11 C-TD1212 127/60, ELISMARY 10.5K 1
PRCAFRTD10 C-TD1212 220/60, ELISMARY 10.5K 1
3619047260 DL-S1,125V16A,BITRON 1
3619047250 DL-S1,250V16A,BITRON 1
9
C-TD1212SPX(SM)(영).indd 9 2013-04-30 오전 11:11:05
Page 11
4. TUB ASSY
D21
D17
D20
D19
D18
D14
D15
D12
D16
D10
D10
D13
D11
D09
D25
D13
D09
D08
D26
D05
D22
D24
D08
D23
D09
D05
D08
D04D07
D01
D02
D06
D06
D05
D08
D03
10
C-TD1212SPX(SM)(영).indd 10 2013-04-30 오전 11:11:11
Page 12
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
D01 TUB F 3618831800 FRPP 1
D02 SPECIAL SCREW 3616029800 SWCH 6.5X30 13
D03 SPECIAL SCREW 3616029400 SWCH 8.5X30 8
D04 CLAMP GASKET AS 3611203600 BETWEEN GASKET & TUB F 1
D05 DAMPER FRICTION 361A700130 60N AKS ST=170-260 DL=197.5 LOW NOISE 4
BALANCER WEIGHT R/L AS
D06
D07 GASKET 3612320710 EPDM 1
D08 DAMPER PIN 361A700200 AKS D=14.5 4
D09 LIFTER WASH 361A401500 11KG, NANO SILVER 3
D10 SPRING SUSPENSION 3615120700 L=233 K=1.0 2
D11 GASKET TUB 3612321100 EPDM FORM 1
D12 TUB R 3618831900 FRPP 1
3616107600 11KG,6.5KG(R/L),AGITATION LOW 2
D13 BEARING INNER 3616303100 F,L,E,U,6206Z 1
D14 BEARING OUTER 3616303200 F,L,E,U,6205Z 1
D15 BEARING HOUSING 3616304600 ALDC, DWD-T120R 1
D16 HOSE AIR 3613266300 EPDM, DWD-100DR 1
D17 HEATER WASH
D18 UNIT STATOR BLDC 36189L620L AL,DON1300W 30T 36POLE,NMT,PBT 1
D19 SPECIAL BOLT AS 3616063400 SWCH M8X58 + SILOCK 6
D20 UNIT ROTOR BLDC 36189L630L DON1300W SR-FERRITE12,30~32T,NMT 1
SPECIAL BOLT AS(ROTOR)
D21
D22 VALVE AIR AS 3615416010 11KG PUMP, WIRE CLAMP 1
D23 AIR TRAP AS 3610AAR110 C-TD1212 1
D24 DRAIN HOUSING *I 36196TAM00 PP,PUMP 1
D25 DRUM AS 3617030220 C-TD1211
DRUM CENTER 3617030200 SUS 0.6T 1
D26
3612802440 120V 1KW.1R0A721005.RW8TF1PE.IRCA 1
3612802400 220V 2KW.1R0A721001.RW8TF.IRCA,NPB 1
3616029620 SWCH 10*30 S/W P/W NON-SEAL LOCK 1
11
C-TD1212SPX(SM)(영).indd 11 2013-04-30 오전 11:11:12
Page 13
5. DOOR AS
E01
E12
E14
E04
E11
E05
E06
E15
E07
E13
E16
E10
E09
E08
E03
E02
12
C-TD1212SPX(SM)(영).indd 12 2013-04-30 오전 11:11:16
Page 14
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
E01 DOOR AS 36117YDX00 ELISMARY 10.5KG 1
E02 FRAME DOOR O 36122WDL00 ABS, C-TD1211 1
E03 DECO DOOR O 36116DX400 ABS, C-TD1211 1
E04 PROTECTOR GLASS 3618346300 TR-ABS,C-TD1211 1
E05 DECO DOOR I 36116DX500 ABS, C-TD1211 1
E06 DOOR GLASS 361A110500 GLASS(11KG/13KG)_BORAL 1
E07 HOOK SAHAFT 3613101000 SUS,Ø3.0 1
E08 HOOK SPRING 3615119300 SUS 1
E09 HOOK DOOR 361310090L ZNDC 1
E10 FRAME DOOR I 36122WDM00 PP,C-TD1211 1
E11 CAP HINGE DOOR 3610916500 POM 4
E12 HINGE DOOR 3612905000 ZNDC , C-TD1211 1
E13 DOOR SAFETY LOCK 361A113200 EPDM 1
E14 HINGE SAFETY LOCK 3612904100 POM 1
E15 SCREW TAPPING 3616051229 STS430 F/L BOLT(SE) 5*12 4
E16 SCREW TAPPING 7115402029 T1S FLT 4*20 STS430 NATURAL 18
13
C-TD1212SPX(SM)(영).indd 13 2013-04-30 오전 11:11:16
Page 15
6. DUCT B (for dry model)
F01
F23
F10
F14
F16
F02
F22
F24
F18
F19
F08
F09
F17
F15
F11
F21
F12
F20
F13
F04
F07
C-TD1212SPX(SM)(영).indd 14 2013-04-30 오전 11:11:18
F03
F06
F05
14
Page 16
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
F01 DUCT B AS
F02 DUCT UPPER 361A202600 ALCOSTA 0.7T 1
F03 DUCT GUIDE 361A202700 AL 1
F04 DUCT B LOWER 361A202200 AL, 3T, DWD-T110RP 1
F05 THERMISTOR DRY 361AAAAC35 R40=26.065kΩ,R90=4.4278kΩ 1
F06 CUSHION DUCT 3611567200 EPDM FOAM, 10*20*4T 1
F07 GASKET SEAL A 3612328300 C-TD1211 ROUND PIE5 L=1360 1
F08 HEATER DRY
F09 SWITCH THERMOSTAT 3619047400 UL. 120ON-150OFF,125V/15A,250V/10A 1
F10 UNIT FAN MOTOR 36189M2Q00
F11 COVER DUCT 3611428710 C-ED, GFPP 30% 1
F12 FAN AS 3611886400 L, GFPP30% 1
F13 FRAME HEATER FRANGE 36122WDN00 SBHG 1.2T 1
F14 RING O 3614603420 L,E,U,W'S ID7.65 T1.8 NBR 70DEG 1
361DUCTBT1 C-TD1212SPX ELISMARY 10.5K 1
361DUCTBT0 C-TD1212LPX ELISMARY 10.5K 1
3612800900
3612802100
220V 2100W 23.05OHM 6.1W/SQ INCOLOY800 1R1A034001
UL120V/1.2KW12OHM3.5W/SQ. INCOLOY800.RA8.1R1A034006
DL7806SSWC/W(NEWMOTEC) 17.5V VDC
C.W
1
1
1
F15 NUT HEX 3616032100 M6*1.0P,CCW 1
F16 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 8
F17 SCREW TAPPING 7122501611 T2 TRS 5X16 MFZN 2
F18 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 1
F19 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 8
F20 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
F21 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
F22 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 5
F23 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 3
F24 PACKING THERMOSTAT
3614009900 SILICON, DWD-100DR 1
15
C-TD1212SPX(SM)(영).indd 15 2013-04-30 오전 11:11:19
Page 17
7. CABINET ASSY
G04
G25
G09
G19
G26
G27
G29
G20
G28
G08
G06
G03
G05
G07
G10
G23
G11
G13
G12
G24
G23
G22
G15
G16
G17
G09
G02
G11
G18
G21
C-TD1212SPX(SM)(영).indd 16 2013-04-30 오전 11:11:24
G14
16
Page 18
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
G01 CABINET ASS,Y
G02 CABINET 361081WM00 SGCC 0.8T,C-TD1212 1
G03 FRAME TOP *R 36122WDH00 SGCC 1.4T,C-TD1212 1
G04 FRAME TOP *L 36122WDG00 SGCC 1.4T,C-TD1212 1
G05 FRAME COVER 36122WDK00 SGCC 1.4T,C-TD1212 1
G06 COVER BACK AS 3611425510 COVER BACK + PAD CABINET AS 1
G07 PCB INVEERTER AS
G08 FIXTURE PLATE 3612008000 130RP,POM 8
G09 STOPPER SPRING 3615202200 POM, DWD-100DR 2
G10 FRAME UPPER 36122WDJ00 SGCC 2.0T,C-LD1542 1
G11 HANDLE CABINET 3612615400 PP 2
G12 UNIT DRAUN PUMP AS
G13 BASE *U 3610395300 PP 1
G14 FRAME LOWER 36122WDP00 SGCC 1.2T,C-TD1212LPX 1
G15 FOOT AS 3616067500 BUTYL, DWD-100DR 4
G16 SPECIAL NUT 3616030200 SCP1, LEG 4
G17 SUPPORTER LEG 3615303610 SGCC, 2.3T 4
G18 LEG ADJUST AS 3617703830 D11+D12+D13 4
G19 SENSOR PRESSURE 3614825230
G20 CORD POWER AS
G21 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
G22 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 28
G23 SCREW TAPPING 3616029950
G24 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
G25 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
G26 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 2
G27 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 4
G28 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 8
G29 SCREW MACHINE 7002400811 TT3 TRS 4X8 MFZN 2
PRCACATD01 C-TD1212SPX 127V/60HZ 1
PRCACATD00 C-TD1212LPX 220V/60HZ 1
PRPSSWLG01
PRPSSWLF01
36189L5722
36189L5J60
3611342370
3611342371
ELISMARY 9KG MAIN
C-LD145,127V,DRY,COLD
ELISMARY 9KG MAIN
C-LD145,220V,DRY,COLD
LEILI AL, 35W 110-127V/60HZ ELISMARY 10.5KG
LEILI AL.220/60 DPH6 35W ELISMARY 10.5KG
TILT-DRUM 2ND, DN-DD04,
INLET=180 U2
BRAZIL ANGLE DANEVA 3X1.5SQ H05VV-F,127V
BRAZIL ANGLE DANEVA 3X1.5SQ H05VV-F,220V
TTS"S" HEX F/L 4*8 4
1
1
1
1
1
1
1
17
C-TD1212SPX(SM)(영).indd 17 2013-04-30 오전 11:11:24
Page 19
8. CASE DETERGENT ASS'Y
H01
H09
H08
H07
H02
H05
H04
H03
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
H01 CASE DETERGENT AS 36111T5410 ELISMARY 10.5KG 1
H02 CASE DETERGENT 36111T5400 ABS 1
H03 CASE HANDLE 36111T5500 ABS 1
H04 DECO HANDLE 36116DX300 ABS 1
H05 CAP HANDLE 3610921500 ABS 1
H06 SPRING CASE HANDLE 3615120400 SUS304, D=0.6 1
H07 CAP SOFTNER 3610921600 PP 1
H08 CASE LIQUID 36111T5600 ABS 1
H09 CAP LIQUID 3610921700 PP 1
H06
18
C-TD1212SPX(SM)(영).indd 18 2013-04-30 오전 11:11:26
Page 20
9. PLATE TOP ASSY
I01
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
I01 PLATE TOP AS 3614544200 SECC 1.0T,WH PAINTED 1
I02 SCREW TAPPING 7122401411 T2S TRS 4X14 MFZN 3
I02
10. ACCESSORIES
HOSE INLET AS MANUAL OWNERS
CAP HOLDER
(4EA)
GUIDE HOSE
DRAIN
(OPTION)
UNIT SVC WRENCH
(OPTION)
I01 I02 I03 I04 I05
No. PARTS NAME CODE SPECIFICATIONS Q’TY REMARK
I01 HOSE INLET AS 361321610L SCREW, COLD, NEW IM, G/S 1
I02
MANUAL OWENERS
I03 CAP HOLDER 3610916420 PP, DWD-100DR 4
I04
GUIDE HOSE DRAIN
I05
UNIT SVC WRENCH
BOX PACKING 3610529500 DW-2, 650*730*880 1
BOX PACKING 3610529500 DW-2, 650*730*880 1
CUSHION SHOULDER 3611581300 BRAZIL ELISMARY 10.5KG EPS 1 1 pair
CUSHION CORNER *R 3611581500 BRAZIL ELISMARY 10.5KG EPS 1 1 pair
CUSHION CORNER * 3611581400 BRAZIL ELISMARY 10.5KG EPS 1 1 pair
3613925740 L'S 1
3612502300 PP,JI-360 1
36189L3X0L EGI, 2.3T, DWD-100DR 1
19
C-TD1212SPX(SM)(영).indd 19 2013-04-30 오전 11:11:29
Page 21
4. CONTROL PART FUNCTION SPECIFICATION
1. SEQUENCE CHART
Division
Sensing 20 sec
Water Supply 2 min
Heating
W
A
S
H
Tumbling
Drain+Remove Foam 1+4 min
B spin 2 min
Middle spin 3/4 min 3 3 4 4 3 3
Water Supply 2 min
Rinsing1 4/5 min 4 4 5 5 5 5
Drain+Remove Foam 1+4 min
R
I
N
S E
S P
I
N
END
B spin 2 min
Middle spin 3/4 min 3 3 3 3
Water Supply 2 min
Rinsing2 4/5 min 4 4 5 5
Drain+Remove Foam 1+4 min
B spin 2 min
Middle spin 3/4 min
Water Supply 2 min
Rinsing3 4/5 min
Drain+Remove Foam 1+4 min
B spin 2 min
Main
Spin
Turbo x min 1 6 1 9 9 9
Normal x min 1 0 1 0
Light x min
Case Care 60 sec
end 10 sec
Time Display 1:30 1:30 3:03 3:03 2:30 2:35 2:30
Process
Time
70 min
65 min
60 min
55 min
50 min
140 min
80 min
40 min
30 min
25 min
20 min
Normal Heavy Stain Removal Dry Only
Low Med Low Med Low Med Low
NOTE
20
C-TD1212SPX(SM)(영).indd 20 2013-04-30 오전 11:11:29
Page 22
Division
Sensing 20 sec
Water Supply 2 min
Heating
W
A S H
Tumbling
Drain+Remove Foam 1+4 min
B spin 2 min
Middle spin 3/4 min 3 3 3 3 4 3 3
Water Supply 2 min
Rinsing1 4/5 min 4 4 4 4 4 5 5
Drain+Remove Foam 1+4 min
R
I N S E
S P
I N
END
B spin 2 min
Middle spin 3/4 min 3 3 3 3 4 3 3
Water Supply 2 min
Rinsing2 4/5 min 4 4 4 4 4 5 5
Drain+Remove Foam 1+4 min
B spin 2 min
Middle spin 3/4 min 3 3
Water Supply 2 min
Rinsing3 4/5 min 4 4
Drain+Remove Foam 1+4 min
B spin 2 min
Main
Spin
Turbo x min
Normal x min 1 0 1 0 1 0 1 0 9 1 0 1 0
Light x min
Case Care 60 sec
end 10 sec
Time Display 1:25 1:25 1:35
Process
Time
70 min
65 min
60 min
55 min
50 min
40 min
38 min
35 min
30 min
25 min
20 min
Jeans Bed & Bath Blanket Black
Low Med Low Med Low Low Med
1:35 1:23 1:30 1:30
NOTE
21
C-TD1212SPX(SM)(영).indd 21 2013-04-30 오전 11:11:30
Page 23
Division
Sensing 20 sec
Water Supply 2 min
Heating
W
A S H
Tumbling
Drain+Remove Foam 1+4 min
B spin 2 min
Middle spin 3/4 min 3 3 3 3 4 3 3
Water Supply 2 min
Rinsing1 4/5 min 4 4 4 4 2 4 4
Drain+Remove Foam 1+4 min
R
I N S E
S P
I N
END
B spin 2 min
Middle spin 3/4 min 3 3 3 3 3 3
Water Supply 2 min
Rinsing2 4/5 min 4 4 4 4 4 4
Drain+Remove Foam 1+4 min
B spin 2 min
Middle spin 3/4 min
Water Supply 2 min
Rinsing3 4/5 min
Drain+Remove Foam 1+4 min
B spin 2 min
Main
Spin
Turbo x min
Normal x min 1 0 1 0 1 0 1 0 2
Light x min 8 8
Case Care 60 sec
end 10 sec
Time Display 1:31 1:31 2:28 2:28 0:30 1:17 1:17
Process
Time
70 min
65 min
60 min
55 min
50 min
45 min
43 min
41 min
30 min
20 min
6 min
Colors White Quick 30 Delicate
Low Med Low Med Low Low Med
NOTE
22
C-TD1212SPX(SM)(영).indd 22 2013-04-30 오전 11:11:30
Page 24
2. Skill of Spin and Dry Sequences
2-1. Spin Sequence
1) Drain ① It follows Drainage Sequence.
2) Balance Spin ① Soap-sud removing sequence operates before B-Spin in every washing course(including middle spin) . ② B-Spin is Until Unbalance check section, 350 r.p.m
3) R(Real) Spin ① From end of B-Spin to end of Spin Sequence is R Spin. ② r.p.m is affected by sequence
2-2. End
1) Crease Care ① Crease Care is process of removal laundry that stick to drum. It works 60sec ,after Spin Sequence.
2) End ① After 10 sec power off ,alamed END. ② If drying sequence added, drying sequence works. ③ After END , door unlock.
23
C-TD1212SPX(SM)(영).indd 23 2013-04-30 오전 11:11:30
Page 25
2-3. Drying Sequence
* Course Setting
Course
Item
Easy Ironing 150 150 150 150 150 150
Normal 240 240 240 240 240 240
Run Time
(min)
Motor On/Off
Time(sec)
Dry
Heater On/Off
Temp(°C)
Extra Dry 270 270 270 270 270 270
Time(30) 30 30 30 30 30 30
Time(60) 60 60 60 60 60 60 Time(120) 120 120 120 120 120 120 Time(180) 180 180 180 180 180 180
Crease Care 10/5 10/5 10/5 10/5 10/5 10/5
Drying 15/5 15/5 15/5 15/5 15/5 15/5
Cooling 10/10 10/10 10/10 10/10 10/10 10/10
Easy Ironing 70/60 70/60 70/60 70/60 70/60 70/60
Normal 105/95 105/95 105/95 105/95 105/95 105/95
220V
110V
Extra Dry 105/95 105/95 105/95 105/95 105/95 105/95
Time
(30/60/120/180)
Easy Ironing 70/60 70/60 70/60 70/60 70/60 70/60
Normal 95/90 95/90 95/90 95/90 95/90 95/90
Extra Dry 95/90
Time
(30/60/120/180)
Normal Heavy
105/95 105/95 105/95 105/95 105/95 105/95
95/90 95/90 95/90 95/90 95/90
95/90 95/90 95/90 95/90 95/90 95/90
Stain
Removal
Dry Only Jeans
Bed
& Bath
Course
Item
Easy Ironing - 150 150 150 - 150
Normal - 240 240 240 - 240
Run Time
(min)
Motor On/Off
Time(sec)
Dry
Heater On/Off
Temp(°C)
Extra Dry - 270 270 270 - -
Time(30) - 30 30 30 - 30
Time(60) - 60 60 60 - 60 Time(120) - 120 120 120 - 120 Time(180) - 180 180 180 - 180
Crease Care - 10/5 10/5 10/5 - 10/5
Drying - 15/5 15/5 15/5 - 15/5
Cooling - 10/10 10/10 10/10 - 10/10
Easy Ironing - 70/60 70/60 70/60 - 60/50
Normal - 105/95 105/95 105/95 - 60/50
220V
110V
Extra Dry - 105/95 105/95 105/95 - -
Time
(30/60/120/180)
Easy Ironing - 70/60 70/60 70/60
Normal - 95/90 95/90 95/90 - 60/50
Extra Dry - 95/90 95/90 95/90 - -
Time
(30/60/120/180)
Blanket Black Colors White Quick 30 Delicate
- 105/95 105/95 105/95 - 60/50
- 60/50
- 95/90 95/90 95/90 - 60/50
2424
C-TD1212SPX(SM)(영).indd 24 2013-04-30 오전 11:11:30
Page 26
3. Main Function of PCB Program
3-1. LOAD SENSING
1) Deciding the water level
Normal, White, Eco-White Course will be followed by this process.
Check the water level with dry laundry at the starting wash.
Check the water level by using motor output data during 20 sec, 65rpm.
2) Deciding Spin Starting Step.
Check after finishing washing step with wet laundry.
Checking by using motor output data during 20 sec, 65 rpm.
The Decided data is different depending on loading condition.
3-2. Balance Spin
1) Motor runs during balance spin
Spreading the laundry : Rotating the same 45 rpm with left and right direction alternatively.
Unbalance checking point : first step, sheck the U.B at 95 rpm, 160 rpm second step, check the U.B
at 95 rpm 350 rpm.
Third step at 300 rpm. If the unbalance data is over the criterion
This process will be repeated.
After drain, check the unbalance data again. This is so-called balance spin step.
3) Property of balance spin
Conducting 20 times maximum.
If the washer can not pass balance spin step during 20 times, then water will be supplied.
If the washer can not pass 20 times of balance spin, UE error mode will be displayed on '18:88'
25
C-TD1212SPX(SM)(영).indd 25 2013-04-30 오전 11:11:30
Page 27
3-3. DOOR S/W
1) The working principle of Door S/W
Door Locking
Bimetal on (3 sec) solenoid (supply 20msec pulse 2 times)
Door Unlocking
Bimetal off solenoid(supply 20msec pulse, until lock)
After door locking all parts can work nomally.
After pressing power button, if the temperature of wash thermistor is over 61 or the water level is
over the safety level, the door will be locked.
The door will be unlocked immediately after all processes are finished.
The door can be opened during processing if there is no problem to unlock.
2) DOOR OPEN SYSTEM
If add the laundry during washing, press the door unlock button.
Door open sequence at abnormal condition.
3-4. The sequence of drain
If the checking time to reset point is below 1 min, the remaining drain time is 40 sec.
If the checking time to reset point is over 1 min, the remaining drain time is 2 min.
If the checking time to reset point is over 10 min, OE signal will be appeared on PCB.
If the temperature is over 50 , the water will be supplied to high water level, then the drain will
start.
26
C-TD1212SPX(SM)(영).indd 26 2013-04-30 오전 11:11:30
Page 28
4. TEST MODE
4-1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
Press power button Press "SPIN" button 3 times with pressing "Temp" button 'L d' will be shown
on LED Whenever pressing "TEMP" button 1 time, below process will be occurred.
No. Display Notes
1 - Version of the Program 2 L_C Lock Close 3 F FAN MOTOR 4 H HOT VALVE 5 C COLD VALVE 6 P PRE VALVE 7 d DRY VALVE 8 bb BUBBLE
9 dr Drain Pump 10 run Runing Time 11 b1 Start Error 12 b2 Overload Error 13 b3 Hall Sensor Error 14 b4 Motor Arrangement Error 15 b5 Speed Error 16 b6 Over Current Error 17 b7 AD CONVERSION Error 18 b8 IPM FAULT Error 19 b9 Over Voltage Error 20 ba Low Voltage Error 21 bb Communication Error 22 - Water Level Frequency 23 - Water Temp. inside TUB 24 - Air Temp. inside Drying Duct 25 LO Lock Open
2) More details
When turn on 'LOCK' signal, all process is conducting normaly.
② When working starts, the PCB displays all the sensor conditions.
③ In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
2727
C-TD1212SPX(SM)(영).indd 27 2013-04-30 오전 11:11:30
Page 29
4-2. LED testing mode
1) Process
While pressing "Wash"," Rinse", "SPIN" button simultaniously, press "POWER" button.
ALL LED On SPIN button ALL LED off
2) More tails
LED test can be done with all LED On.
4-3. LED testing and Show room mode
Show room mode is to show and display how the washing courses operate briefly.
1) Process
While pressing "DOOR LOCK" button, press "POWER" button.
ALL LED On → ALL LED off automatically → Show room mode starts automatically → Show room
mode ends automatically
28
C-TD1212SPX(SM)(영).indd 28 2013-04-30 오전 11:11:30
Page 30
5. How to use Service Tool
1) Number of the test item
2) Name of the test item
3) Status of the test item
4) Buttons to change test item, up and down
5) Load On/Off
NO. Items Details
1 Versão de SW put the software version
2 Porta
3 Porta
4 Trava Porta
5 Valvula Sabão Command to tun on and turn off the main wash valve
6 Val. Pre lav. Command to tun on and turn off the pre wash valve
7 Valvula Amac. Command to tun on and turn off the softener valve
8 Bomba Drenag Command to tun on and turn off the pump
9 Seca Sensor request with the value of the drying sensor temperature reading in ºC
10 Ventoinha Command to tun on and turn off the motor fan
11 Vent + Res Command to tun on and turn off the motor fan + drying heater
12 Teste Leds Command to tun on and turn off all LEDS including the module display
13 Teste Teclas test the buttons when press any button the name of them must be displayed
14 Teste Progr.
15 Pressao H2O
16 Lava Sensor request with the value of the wash sensor temperature reading in ºC
17 Lava. Resist. Command to turn on and turn off the wash heater
18 Agitacao Command to start the agitation with normal prole
19 Centrifuga Command to start the spin phase until 500rpm and showing the in the display the motor speed
Aberta or Fechada (request of the door switch position status: pushed (Fechada) or not pushed (Aberta))
Aberta or Fechada (request of the door hook position status: unlocked (Aberta) or locked (Fechada))
"Travada or Destravada ( command to lock and unlock the door lock. When the machine has the door lock shows Travada. When the machine has the door unlock shows Destravada) "
Test the knob = > turn the knob the program name must be displayed. Like: Rapido, Delicado, Normal etc
"Test the water level pressure sensor. When the test starts the machine will ready the pressure level and it will show in the display the value Empty(Vazio), Low(Baixo) or High (Alto). To start the test all valves must be turn on and then when the water level is lower than minimum level AAAkHz the service tool will show “Vazio”, when the level achieve XXXkHz (normal level) showing “Baixo”, when achieve YYkHz (blanket level) showing “Alto”. Once achieve the higher level the valve must be turn off."
29
C-TD1212SPX(SM)(영).indd 29 2013-04-30 오전 11:11:30
Page 31
6. Error Display
MESSAGE
IE
OE
UE
LE
E1
E2
E3
E4
E5
E6 EMG ERROR
ERROR CAUSE SOLUTION
WATER
INLET ERROR
DRAIN
ERROR
UN-BALANCE
ERROR
DOOR
OPEN ERROR
Water level
detection error
OVER
FLOW ERROR
FAN MOTOR
ERROR
LEAKAGE
ERROR
HIGH
VOLTAGE
ERROR
The water tap is closed. Open the water tap. The lter of the valve inlet is clogged. Clean the lter of the valve inlet. The valve inlet is an inferior product or broke down. Change the valve inlet.
The water level sensor (sensor pressure) is an inferior product or broke down.
The drain motor works during water supply. Change the drain motor. The PCB ASS’Y does not check the water level. Change the PCB ASS’Y. The drain hose is kinked or clogged. Clean and straighten the drain hose. The drain motor is an inferior product. Change the drain motor. The valve inlet works during drain. Change the valve inlet The water level sensor is an inferior product . Change the water level sensor. The PCB ASS’Y does not check the water level. Change the PCB ASS’Y. The laundry is concentrated to one side of the drum
during spin.
The Start/Hold button is pressed while the door is opened.
The switch door lock is an inferior product. Change the switch door lock. The PCB ASS’Y does not check the door lock. Change the PCB ASS’Y. Water level is below reset or overow is detected Change the sensor pressure.
The water is supplied continuously due to an inferior valve inlet.
The valve inlet is normal, but the water level sensor (sensor pressure) is inferior.
The drain motor dose not work. (The fan motor is an inferior product or broke down.)
The fan motor does not work. (The fan motor is an inferior product or broke down.)
The PCB ASS’Y does not control the fan motor. Check the connector or change the
Water leaks from the tub or the hose drain. Check the leak of the tub or the hose
The foreign matter is jammed in the drain bellows. (Non-pump model)
The laundry is jammed between the gasket and the drum.
The PCB ASS’Y is an inferior product. Change the PCB ASS’Y. The laundry is jammed between the gasket and the
drum. The motor is an inferior product. Change the motor. The PCB ASS’Y is an inferior product. Change the PCB ASS’Y.
Change the water level sensor (sensor pressure).
Rearrange the laundry.
Close the door.
Change the valve inlet.
Change the water level sensor (sensor pressure).
Change the drain motor.
Change the fan motor.
PCB ASS’Y .
drain. Then change the tub or the hose drain.
Remove the foreign matter in the drain bellows.
Rearrange the laundry.
Rearrange the laundry.
3030
C-TD1212SPX(SM)(영).indd 30 2013-04-30 오전 11:11:30
Page 32
MESSAGE
E7
E8
E9
H1
H2
H3
H4
H5
H6
H7
H8
PFE
ERROR CAUSE SOLUTION
The motor spins into an opposite direction. Change the PCB ASS’Y or the
DIRECTION
ERROR
MOTOR ERROR
SENSOR
PRESSURE
ERROR
THERMISTOR
(TEMP. SENSOR)
DRY ERROR
THERMISTOR
WASH ERROR
THERMISTOR
DRY
OVERHEATING
ERROR
THERMISTOR
WASH
OVERHEATING
ERROR
WATER TEMP.
ERROR
HEATER
WASH
ERROR
HEATER
DRY ERROR
HEATER
WASH
OVERHEATING
ERROR
PUMP FILTER
ERROR
The motor hall IC is an inferior product or broke down.
The motor is not normally connected. Check the connector of the motor. The motor does not work.
(The motor is an inferior product or broke down.) The water level sensor is an inferior product. Change the water level sensor.
The thermistor dry is an inferior product or broke down.
The thermistor dry is not connected normally. Check the connector of the thermistor
The thermistor wash is an inferior product or broke down.
The thermistor wash is not connected normally. Check the connector of the thermistor
The fan motor does not spin with the proper rpm. (The fan motor is an inferior product or broke down.)
The thermistor dry is an inferior product or broke down.
The heater worked without the water in the tub. Check the water level. The thermistor wash is an inferior product or
broke down.
The water temp. is over 45°C in delicate & wool course.
The heater wash dose not work. (The water temp. doesn't rise over 2°C during
15min.)
The heater dry dose not work. (The water temp. doesn't rise over 3°C during 8min.)
The heater worked without the water in the tub. Check the water level and the heater
The drain pump lter is clogged. Clean the drain pump lter. The drain pump does not work during spin. Change the drain pump. The large amount of detergent was used. Use the proper amount of detergent. The drain hose is placed higher than 1m above the
oor.
motor. Change the motor hall IC or the
motor.
Change the motor.
Change the thermistor dry.
dry. Change the thermistor wash.
wash. Change the fan motor.
Change the thermistor dry.
Change the thermistor wash.
Change the thermistor wash.
Change the heater wash.
Change the heater dry.
wash.
Place the drain hose 1m below the oor
3131
C-TD1212SPX(SM)(영).indd 31 2013-04-30 오전 11:11:30
Page 33
5. ELECTRONIC FIELD PARTS LIST AND SPECIFICATION
No Part Name Part Code SPECIFICATIONS Q'ty
1
PCB INVERTER AS
2 PRPSSWLF01 ELISMARY 10.5K MAIN C-TD121 220/60 DRY COLD 1
3 HARNESS AS 3612796370 ERISMARY 10.5K NON BB,COLD,NON RT 1
4
UNIT DRAIN PUMP AS
5 36189L5J60 LEILI AL. 35W 220V/60HZ ELISMARY 10.5KG 1
6
HEATER WASH
7
THERMISTOR WASH
8
UNIT STATOR BLDC
9
UNIT ROTOR BLDC
10
11
SWITCH DOOR LOCK
12
SWITCH DOOR
13
14
PCB AS
15
16
HEATER DRY
17
18 SWITCH THERMOSTAT 3619047400 UL. 120ON-150OFF,125V/15A,250V/10A 1
19 FUSE TEMPERATURE 361A800121 128°C DF-128S 15A 250V VDE 1
20 UNIT FAN MOTOR 36189M2Q00 DL7806SSWC/W(NEWMOTEC) 17.5V VDC C.W 1
21
VALVE INLET
22 3615415050
23
CORD POWER AS
24 3611342371 BRAZIL ANGLE DANEVA 3X1.5SQ H05VV-F,220V 1
PRPSSWLG01 ELISMARY 10.5K MAIN C-TD121 127/60 DRY COLD 1
36189L5722 LEILI AL, 35W 127V/60HZ ELISMARY 10.5KG 1
3612802440
3612802400
361AAAAB10
36189L620L
36189L630L
3619047260
3619047250
3619047710
PRPSSWLE10
PRPSSWLE10
3612802100
3612800900
3615415070
120V 1KW.1R0A721005.RW8TF1PE.IRCA
220V 2KW.1R0A721001.RW8TF.IRCA,NPB
R25=1.704kΩ R80=11.981kΩ
AL,DON1300W 30T 36POLE,NMT,PET CLASS F EL9K
DON1300W SR-FERRITE12,30~32T,NMT EL9K
DL-S2, 125V 6A, BITRON
DL-S2, 250V 16A, BITRON
UL,DRUM,SPE110F-1D7,DC5V 5MA
C-TD1212 ELISMARY 10.5K 127/60
C-TD1212 ELISMARY 10.5K 220/60
UL120V/1.2KW12OHM3.5W/SQ.INCOLOY800.RA8.1R1A034006
220V 2100W 23.05OHM 6.1W/SQ INCOLOY800 1R1A034001
100~130V,3WAY,RINSE GUIDE,PP/BRACKET
220~240V,3WAY,RINSE GUIDE,PP/BRACKET
3611342370 BRAZIL ANGLE DANEVA 3X1.5SQ H05VV-F,127V 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32
C-TD1212SPX(SM)(영).indd 32 2013-04-30 오전 11:11:30
Page 34
6. WIRING DIAGRAM
3333
C-TD1212SPX(SM)(영).indd 33 2013-04-30 오전 11:11:31
Page 35
DAEWOO ELECTRONICS CORP.
686, AHYEON-DONG MAPO-GU SEOUL, KOREA
C.P.O. BOX 8003 SEOUL, KOREA
TELEX: DWELEC K28177-8 CABLE: “DAEWOOELEC”
S/M NO. :
C-TD1212SPX(SM)(영).indd 34 2013-04-30 오전 11:11:31
PRINTED DATE: Apr. 2013
Page 36
S/M No. :
Service Manual
Drum Washing Machine
Model: C-TD1212SPX
C-TD1212LPX
Caution
: In this Manual, some parts can be changed for improving, their
performance without notice in the parts list. So, if you need the
latest parts information, please refer to PPL(Parts Price List) in
Service Information Center (http://svc.dwe.co.kr).
Apr. 2013
C-TD1212SPX(SM)(영).indd 35 2013-04-30 오전 11:11:31
Page 37
ABOUT THIS MANUAL
ABOUT THIS MANUAL
VISION CREATIVE. INC
담 당 박종원 님 (서비스메뉴얼)
F.MODEL BUYER
B.MODEL
언 어 영문 COUNTRY
일 정
제 판 인 쇄 애드컴
규 격
MEMO 접수 :
C-TD1212SPX C-TD1212LPX
1차
2차
3차
4차
5차
(총 36p)_CS4 130404 - 신규 총 36p(1~36) 130423 - 신규 총 36p(1~36)_정건기 님
130430 - 수정 총 11p(5,7,9,10,11,13,14,15,17,18,
19)_정건기 님
BRAND DAEWOO
서울 종로구 통의동
6번지 이룸빌딩 4층
.
연락처
담 당 방 문 수(choi)
VISION
TEL : 730-0660 FAX : 730-3788
C-TD1212SPX(SM)(영).indd 36 2013-04-30 오전 11:11:31
Loading...