2) Balance Spin
① Soap-sud removing sequence operates before B-Spin in every washing course(including middle spin) .
② B-Spin is Until Unbalance check section, 350 r.p.m
3) R(Real) Spin
① From end of B-Spin to end of Spin Sequence is R Spin.
② r.p.m is affected by sequence
2-2. End
1) Crease Care
① Crease Care is process of removal laundry that stick to drum. It works 60sec ,after Spin Sequence.
2) End
① After 10 sec power off ,alamed END.
② If drying sequence added, drying sequence works.
③ After END , door unlock.
Bimetal off → solenoid(supply 20msec pulse, until lock)
③
After door locking all parts can work nomally.
④
After pressing power button, if the temperature of wash thermistor is over 61℃ or the water level is
over the safety level, the door will be locked.
⑤
The door will be unlocked immediately after all processes are finished.
⑥
The door can be opened during processing if there is no problem to unlock.
2) DOOR OPEN SYSTEM
①
If add the laundry during washing, press the door unlock button.
②
Door open sequence at abnormal condition.
3-4. The sequence of drain
①
If the checking time to reset point is below 1 min, the remaining drain time is 40 sec.
②
If the checking time to reset point is over 1 min, the remaining drain time is 2 min.
③
If the checking time to reset point is over 10 min, OE signal will be appeared on PCB.
④
If the temperature is over 50℃ , the water will be supplied to high water level, then the drain will
start.
26
C-TD1212SPX(SM)(영).indd 262013-04-30 오전 11:11:30
Page 28
4. TEST MODE
4-1. Testing Mode
PCB and other electronic parts will be tested without water supply whether they are normal or not.
1) Process
Press power button → Press "SPIN" button 3 times with pressing "Temp" button → 'L d' will be shown
on LED → Whenever pressing "TEMP" button 1 time, below process will be occurred.
No.DisplayNotes
1-Version of the Program
2L_CLock Close
3FFAN MOTOR
4HHOT VALVE
5CCOLD VALVE
6PPRE VALVE
7dDRY VALVE
8bbBUBBLE
9drDrain Pump
10runRuning Time
11b1Start Error
12b2Overload Error
13b3Hall Sensor Error
14b4Motor Arrangement Error
15b5Speed Error
16b6Over Current Error
17b7AD CONVERSION Error
18b8IPM FAULT Error
19b9Over Voltage Error
20baLow Voltage Error
21bbCommunication Error
22-Water Level Frequency
23-Water Temp. inside TUB
24-Air Temp. inside Drying Duct
25LOLock Open
2) More details
①
When turn on 'LOCK' signal, all process is conducting normaly.
② When working starts, the PCB displays all the sensor conditions.
③ In this case, BLDC Motor is not tested. In order to test it, select spin or rinse.
2727
C-TD1212SPX(SM)(영).indd 272013-04-30 오전 11:11:30
Page 29
4-2. LED testing mode
1) Process
While pressing "Wash"," Rinse", "SPIN" button simultaniously, press "POWER" button.
ALL LED On → SPIN button → ALL LED off
2) More tails
①
LED test can be done with all LED On.
4-3. LED testing and Show room mode
Show room mode is to show and display how the washing courses operate briefly.
1) Process
While pressing "DOOR LOCK" button, press "POWER" button.
ALL LED On → ALL LED off automatically → Show room mode starts automatically → Show room
mode ends automatically
28
C-TD1212SPX(SM)(영).indd 282013-04-30 오전 11:11:30
Page 30
5. How to use Service Tool
①
②
③
④
⑤
1) Number of the test item
2) Name of the test item
3) Status of the test item
4) Buttons to change test item, up and down
5) Load On/Off
NO.ItemsDetails
1Versão de SWput the software version
2Porta
3Porta
4Trava Porta
5Valvula Sabão Command to tun on and turn off the main wash valve
6Val. Pre lav. Command to tun on and turn off the pre wash valve
7Valvula Amac. Command to tun on and turn off the softener valve
8Bomba Drenag Command to tun on and turn off the pump
9Seca Sensor request with the value of the drying sensor temperature reading in ºC
10Ventoinha Command to tun on and turn off the motor fan
11Vent + Res Command to tun on and turn off the motor fan + drying heater
12Teste Leds Command to tun on and turn off all LEDS including the module display
13Teste Teclas test the buttons when press any button the name of them must be displayed
14Teste Progr.
15Pressao H2O
16Lava Sensor request with the value of the wash sensor temperature reading in ºC
17Lava. Resist. Command to turn on and turn off the wash heater
18AgitacaoCommand to start the agitation with normal prole
19Centrifuga Command to start the spin phase until 500rpm and showing the in the display the motor speed
Aberta or Fechada (request of the door switch position status: pushed (Fechada) or not pushed
(Aberta))
Aberta or Fechada (request of the door hook position status: unlocked (Aberta) or locked
(Fechada))
"Travada or Destravada ( command to lock and unlock the door lock.
When the machine has the door lock shows Travada. When the machine has the door unlock
shows Destravada) "
Test the knob = > turn the knob the program name must be displayed. Like: Rapido, Delicado,
Normal etc
"Test the water level pressure sensor.
When the test starts the machine will ready the pressure level and it will show in the display the
value Empty(Vazio),
Low(Baixo) or High (Alto). To start the test all valves must be turn on and then when the water
level is lower than
minimum level AAAkHz the service tool will show “Vazio”, when the level achieve XXXkHz (normal
level) showing
“Baixo”, when achieve YYkHz (blanket level) showing “Alto”. Once achieve the higher level the
valve must be turn off."
29
C-TD1212SPX(SM)(영).indd 292013-04-30 오전 11:11:30
Page 31
6. Error Display
MESSAGE
IE
OE
UE
LE
E1
E2
E3
E4
E5
E6EMG ERROR
ERRORCAUSESOLUTION
WATER
INLET ERROR
DRAIN
ERROR
UN-BALANCE
ERROR
DOOR
OPEN ERROR
Water level
detection error
OVER
FLOW ERROR
FAN MOTOR
ERROR
LEAKAGE
ERROR
HIGH
VOLTAGE
ERROR
The water tap is closed.Open the water tap.
The lter of the valve inlet is clogged.Clean the lter of the valve inlet.
The valve inlet is an inferior product or broke down.Change the valve inlet.
The water level sensor (sensor pressure) is an
inferior product or broke down.
The drain motor works during water supply.Change the drain motor.
The PCB ASS’Y does not check the water level.Change the PCB ASS’Y.
The drain hose is kinked or clogged.Clean and straighten the drain hose.
The drain motor is an inferior product.Change the drain motor.
The valve inlet works during drain.Change the valve inlet
The water level sensor is an inferior product .Change the water level sensor.
The PCB ASS’Y does not check the water level.Change the PCB ASS’Y.
The laundry is concentrated to one side of the drum
during spin.
The Start/Hold button is pressed while the door is
opened.
The switch door lock is an inferior product.Change the switch door lock.
The PCB ASS’Y does not check the door lock.Change the PCB ASS’Y.
Water level is below reset or overow is detected Change the sensor pressure.
The water is supplied continuously due to an inferior
valve inlet.
The valve inlet is normal, but the water level sensor
(sensor pressure) is inferior.
The drain motor dose not work.
(The fan motor is an inferior product or broke down.)
The fan motor does not work.
(The fan motor is an inferior product or broke down.)
The PCB ASS’Y does not control the fan motor.Check the connector or change the
Water leaks from the tub or the hose drain.Check the leak of the tub or the hose
The foreign matter is jammed in the drain bellows.
(Non-pump model)
The laundry is jammed between the gasket and the
drum.
The PCB ASS’Y is an inferior product.Change the PCB ASS’Y.
The laundry is jammed between the gasket and the
drum.
The motor is an inferior product.Change the motor.
The PCB ASS’Y is an inferior product.Change the PCB ASS’Y.
Change the water level sensor
(sensor pressure).
Rearrange the laundry.
Close the door.
Change the valve inlet.
Change the water level sensor
(sensor pressure).
Change the drain motor.
Change the fan motor.
PCB ASS’Y .
drain. Then change the tub or the
hose drain.
Remove the foreign matter in the
drain bellows.
Rearrange the laundry.
Rearrange the laundry.
3030
C-TD1212SPX(SM)(영).indd 302013-04-30 오전 11:11:30
Page 32
MESSAGE
E7
E8
E9
H1
H2
H3
H4
H5
H6
H7
H8
PFE
ERRORCAUSESOLUTION
The motor spins into an opposite direction.Change the PCB ASS’Y or the
DIRECTION
ERROR
MOTOR
ERROR
SENSOR
PRESSURE
ERROR
THERMISTOR
(TEMP. SENSOR)
DRY ERROR
THERMISTOR
WASH ERROR
THERMISTOR
DRY
OVERHEATING
ERROR
THERMISTOR
WASH
OVERHEATING
ERROR
WATER TEMP.
ERROR
HEATER
WASH
ERROR
HEATER
DRY ERROR
HEATER
WASH
OVERHEATING
ERROR
PUMP FILTER
ERROR
The motor hall IC is an inferior product or broke
down.
The motor is not normally connected.Check the connector of the motor.
The motor does not work.
(The motor is an inferior product or broke down.)
The water level sensor is an inferior product.Change the water level sensor.
The thermistor dry is an inferior product or
broke down.
The thermistor dry is not connected normally.Check the connector of the thermistor
The thermistor wash is an inferior product or
broke down.
The thermistor wash is not connected normally.Check the connector of the thermistor
The fan motor does not spin with the proper rpm.
(The fan motor is an inferior product or broke down.)
The thermistor dry is an inferior product or
broke down.
The heater worked without the water in the tub.Check the water level.
The thermistor wash is an inferior product or
broke down.
The water temp. is over 45°C in delicate & wool
course.
The heater wash dose not work.
(The water temp. doesn't rise over 2°C during
15min.)
The heater dry dose not work.
(The water temp. doesn't rise over 3°C during 8min.)
The heater worked without the water in the tub.Check the water level and the heater
The drain pump lter is clogged.Clean the drain pump lter.
The drain pump does not work during spin.Change the drain pump.
The large amount of detergent was used.Use the proper amount of detergent.
The drain hose is placed higher than 1m above the
oor.
motor.
Change the motor hall IC or the
motor.
Change the motor.
Change the thermistor dry.
dry.
Change the thermistor wash.
wash.
Change the fan motor.
Change the thermistor dry.
Change the thermistor wash.
Change the thermistor wash.
Change the heater wash.
Change the heater dry.
wash.
Place the drain hose 1m below the
oor
3131
C-TD1212SPX(SM)(영).indd 312013-04-30 오전 11:11:30
Page 33
5. ELECTRONIC FIELD PARTS LIST AND SPECIFICATION
NoPart NamePart CodeSPECIFICATIONS Q'ty
1
PCB INVERTER AS
2PRPSSWLF01 ELISMARY 10.5K MAIN C-TD121 220/60 DRY COLD1
3HARNESS AS3612796370ERISMARY 10.5K NON BB,COLD,NON RT1