Document # PG05-012
48” (121.9 cm)
Front of open door
Front of handle
Front edge of bull nose
Front panel
Rear of front panel/oven door
28 1/2” (72.4 cm)
(91.9 cm)
36 3/16”
(95.3 cm)
37 1/2”
26 7/8” (68.3 cm)
26” (66.0 cm)
24” (61.0 cm)
1 1/4”
(3.2 cm)
to
1 1/16” (2.7 cm) to cooking
surface (top of grates) from
top of trim
Finished side
panel
X
24” (61.0 cm)
Cabinet face
lines up with
back of control
panel
RNRP36G, RNRP48G
Revised 03/16/15 Page 1/3
Renaissance® 36” and 48” Wide
All Gas Ranges
WARNING
• Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
All tolerances ±1/16” (±1.6 mm) unless otherwise noted.
PLANNING
GUIDE
*
Width: RNRP36G - 35 7/8” (91.1 cm)
RNRP48G - 47 7/8” (121.6 cm)
All specications subject to change without notice.
* The backguard is available in two heights;
3 inches (standard) and 9 inches (optional).
DIMENSIONS (SIDE VIEW)
INSTALLED DIMENSIONS WITHOUT DOWNDRAFT VENT
(SIDE VIEW)
Phone: (800) 793-0093www.dacor.com
Document # PG05-012
RNRP36G, RNRP48G
Revised 03/16/15 Page 2/3
Renaissance 36” and 48” Wide
All tolerances +1/16” (+1.6 mm) -0 unless otherwise noted.
13” (33.0 cm)
5
max.
30” (76.2 cm)
15” (38.1 cm)
4, 5
min.
Grate
level
Note 2
37 1/2”
max.
All Gas Ranges
F
Non-combustible
surface along back wall
recommended
min.
1
G
Suggested
location of
3
utilities
1
Vertical from range grate level to combustible overhead
surface; if installing an overhead vent hood, also check
hood specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
4
Vertical from grate level to combustible surface.
5
This specification does not apply for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the range.
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
PLANNING
GUIDE
Range
Model
RNRP36G
RNRP48G
All specications subject to change without notice.
MINIMUM CABINET CLEARANCES
F G
42” (106.7 cm)*
36” (91.4 cm)**
54” (137.2 cm)*
48” (121.9 cm)**
36”
(91.4 cm)**
48”
(121.9 cm)**
* Recommended ** Minimum
H
33 1/2”
(84.8 cm)
43 1/2”
(110.2 cm)
Phone: (800) 793-0093www.dacor.com