MET304 and METB365-1
Document # PG03-001 Revised 10/01/11 Page 1/3
30 Inch and 36 Inch Wide,
Discovery™ Electric Cooktops
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
30 1/4" *
(76.8 cm)
4" (10.2 cm)
Chassis height
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
PLANNING
GUIDE
21 1/4" *
(54.0 cm)
28 3/8"
19 3/8"
(49.5 cm)
PRODUCT DIMENSIONS - MET304
* For units with stainless steel trim, other units may be up to 1/8" less.
Model No. Electrical Circuit Required
MET304 240 Vac, 60 Hz, 40 Amps. 6.9 kW (29 Amps.)
METB365-1 240 Vac, 60 Hz, 50 Amps.* 9.6 kW (40 Amps.)
* For reference only, See the product data label on bottom of unit for exact specifications.
(72.1 cm)
21 1/4" *
(54.0 cm)
PRODUCT DIMENSIONS - METB365-1
Total Connected
Load*
36 1/4" *
(92.1 cm)
19 3/8"
(49.5 cm)
Minimum Supply Wire Size
Line and Ground Connections
34 3/8"
(87.3 cm)
4" (10.2 cm)
Chassis height
NOTES:
1. The cooktop is supplied with a flexible, 48 inch long
power conduit consisting of two (2) insulated hot lead
conductors (L1 and L2) and one (1) insulated ground
conductor. There is no neutral connection. All leads are
copper. The conduit is connected to the right corner of
the cooktop. Do not connect the ground wire to neutral.
2. Tested in accordance with the latest edition of ANSI
Z21.1 and U.L. 858 Standard for household cooking
appliances.
3. These cooktops are not approved for recessed
installation.
Specications subject to change without notice. Phone: (800) 793-0093www.dacor.com
ELECTRICAL SUPPLY REQUIREMENTS
3.1
![](/html/db/dbdd/dbdd0ba70e3c8501cdd49a120e52fc618c59c5c5c20e044423e129d047588566/bg2.png)
MET304 and METB365-1
Document # PG03-001 Revised 10/01/11 Page 2/3
30 Inch and 36 Inch Wide,
Discovery Electric Cooktops
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Allow a minimum of 6 inches (15.2 cm) clearance between
the top of the countertop and any combustible surface
below, including the upper edge of a drawer below the
cooktop. Proper under-cabinet clearance is also required
for the cooktop hold down brackets.
6” (15.2 cm)
min. clearance
A
Model
MET304 30 1/2” (77.5 cm)
METB365-1 36 1/2” (92.7 cm)
(A) Minimum Under Counter
Clearance (Width)
to combustible
surfaces
PLANNING
GUIDE
When installing model METB365-1 and the bottom of the chassis is to be
enclosed wall to wall, you must install Dacor ventilation duct kit ATD323.
7 3/4” X 4 3/8”ventilationcut-outsinenclosureoor
3
/4”
1 1/2”
1 1/2”
Cooktop cutout in
top of cabinet
3
/4”
UNDER COUNTER CLEARANCE
Model
MET304 28 3/4” (73.0 cm)
METB365-1 34 3/4” (88.3 cm)
(B) Minimum Under Counter
Clearance (Width)
2 1/4" min.
(5.7 cm)
TOP VIEW VENTILATION CUTOUT
Rear
wall
6" (15.2 cm) min.
from mounting surface to
combustibles below
cooktop chassis
B
19 3/4" min.
(50.2 cm)
Specications subject to change without notice. Phone: (800) 793-0093www.dacor.com
1" min.
(2.5 cm)
6" (15.2 cm)
min. to combustible,
side wall, both sides
COUNTERTOP CUTOUT (WITHOUT RAISED VENT)
3.2