MRES30
Rearwall
Vertical
non-combustible
surface
30 1/16”
(764mm)
6”
(152mm)
Min. to Combustible
side wall (both sides)
25”
(635mm)
Countertop
Countertop
29 1/4" (743mm)
30 1/16" (764mm)
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
19 3/4"
(502mm)
29 1/4" (743mm)
30 1/16" (764mm)
Vertical
non-combustible
surface
Vertical
non-combustible
surface
Rear wall Rear wall
4 1/4”
(108mm)
25”
(635mm)
Countertop
Countertop
Countertop
Countertop
23 1/2"
(597mm)
25 5/16"
(643mm)
Rear of
Control Panel/
Oven Door
Max. depth
to oven door
handle with
door closed
30"
(762mm)
45 1/4"
(1149mm)
Removeable
(factory-installed)
3” (76mm)
Side Panels
35 5/16” - 36 13/16”
(897mm - 935mm)
30” Wide,
Millennia™ Range
OvERALL DIMENSIONS OvERALL DIMENSIONS
(Door Open)
PLANNING
1/2092105
GUIDE
(Slide-In, Self-Rimming Installation with Side Panels (Slide-In, Self-Rimming Installation using accessory 3” Side Panels,
and Backguard Removed) Backguard Removed)
Web: http://www.dacor.com
Corporate Phone: 800-793-0093
cOUNtERtOP cAbINEt DIMENSIONS
(Slide-In, Freestanding Installation)
tOP vIEW
cUtOUt DIMENSIONS
Specifications are subject to change without notice.
See installation instructions for additional details.
5.12
L65336 rev D
MRES30
"A"
18” (457mm) Min.
Both Sides
30" (762mm) Min. from finished countertop
to combustible/non-combustible surface
Recommended
Utility Location
6” (152mm) Min.
from edge of cooktop
to combustible side wall
above finished countertop
(both sides)
30” Wide,
Millennia™ Range
PLANNING
2/2091605
GUIDE
Model No. “A” Min. Hood Width “A” Recommended Hood Width
MRES30 30” (762mm) 36” (914mm)
Model No.
MRES30
Dedicated
Circuit
Required
240VAC, 4-wire,
60Hz, 50A
(Breaker)
U
PPER cAbINEt DIMENSIONS
(Upper Cabinets 13” (330mm) Maximum Depth)
Total
Connected Load
11.1kW
(46A)
Approximate
Shipping Weight
297 lbs.
NOTES:
1. Electrical is located in the right rear corner of the
unit.
Range is supplied with a 60” (1524mm) long 240V
2.
4-wire conduit.
3. Utilities may be located in the lower left corner of
the adjacent right cabinet. (Recommended)
4. Alternate location, in the lower right corner behind
the range.
5. Contact your local building department to verify
compliance with local code interpretation.
6. MRES30 Range can be installed with slim (ERV/
PRV) downdraft ventilation.
7. See the Combination Installation (CI) Section if
installing with a downdraft.
Web: http://www.dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.13
L65336 rev D