Dacor IVSR2, IVS2, IVSR1 User Manual 2

IVS1, IVS2, IVSR1, IVSR2
21 1/4"
(540mm)
22 5/8"
(575mm)
6"
(152mm)
11 1/16"
(281mm)
12 1/4"
(311mm)
Electrical
Access
8" (203mm) Round x 2" (51mm) High
with back draft damper
Mounting
Holes
(typ. all sides)
33 1/4"
(845mm)
34 1/2"
(876mm)
6"
(152mm)
11 1/16"
(281mm)
12 1/4"
(311mm)
Electrical
Access
8" (203mm) Round x 2" (51mm) High
with back draft damper
Mounting
Holes
(typ. all sides)
21"
(533mm)
8"
(203mm)
12"
(305mm)
10" Round
12 1/4"
(311mm)
Equal Equal
22 5/8" (575mm)
6 1/8"
(156mm)
8" Round collar
#
,
#
,
12 1/4"
(311mm)
34 /12" (876mm)
6 1/8"
(156mm)
8" Round
Collars
Equal Equal
C
L
C
L
C
L
C
L
6 1/2"
(165mm)
6 1/2"
(165mm)
IVS/R1 OVERALL DIMENSIONS
(Isometric View)
Power Pack
PLANNING
1/1062805
IVS/R2 OVERALL DIMENSIONS
(Isometric View)
GUIDE
Web: http://www.dacor.com Corporate Phone: 800-793-0093
IVS/R1 OVERALL DIMENSIONS
(Top View)
IVS/R2 OVERALL DIMENSIONS
(Top View)
NOTES:
1. An Internal Blower is included with IVS1/IVS2 models. Blower Ratings: 1200CFM for IVS2 and 600CFM for IVS1.
Remote Blower is required for IVSR1/IVSR2
2. models.
The ATD10 is sold seperately.
3.
ATD10 OVERALL DIMENSIONS
Model No.
IVS1
IVSR1 21 lbs.
IVS2 38 lbs.
IVSR2 29 lbs.
(Isometric View)
(For use with IVS/R2)
Dedicated Circuit
120VAC, 60Hz, 15A
Required
(Breaker)
Maximum
Duct Length
Maximum 60
Equivalent
Straight Feet
Total
Connected Load
1.4kW (12A)
Specifications are subject to change without notice. See installation instructions for additional details.
Approximate
Shipping Weight
25 lbs.
7.5