ILB8, ILB10
"A"
"B"
Attachment
Surface
ROTATION
AIRFLOW
120V, 60Hz, 15A POWER SUPPLY
CAUTION: DISCONNECT POWER SUPPLY AT THE FUSE BOX BEFORE SERVICING THIS EQUIPMENT
FAN MOTOR
GR
N
DACOR P/N 85829
WIRING DIAGRAM, ILB-8
M
BK
L
"C"
"D"
Attachment
Surface
Electrical
Access Panel
030106
ISOMETRIC VIEW
Inline Remote Blowers
OVERALL DIMENSIONS SIDE VIEW
PLANNING
1/1
GUIDE
OVERALL DIMENSIONS FRONT VIEW
NOTE:
1. The ILB8 and ILB10 inline blowers are only
approved in updraft (hood) applications.
Model
No.
ILB8 10 5/8” (270mm) 10 1/2” (267mm)
ILB10 12 5/8” (321mm) 12 1/2” (318mm) 10” (254mm) 0.2kW (2A)
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
“A” Overall
Chassis Width
“B” Overall
Chassis Height
“C” Overall
Chassis
Length
5” (127mm)
“D” Duct
Diameter
8” (203mm)
Dedicated
Circuit
Required
Refer to
Ventilator
Specifications
Maximum
Duct Length
Max. 60
Equivalent
Straight Feet
Specifications are subject to change without notice.
See installation instructions for additional details.
TOP VIEW
Total
Connected
Load
0.1kW (1A) 600 CFM 12 lbs.
Blower
Rating
1100
CFM
Approximate
Shipping
Weight
16 lbs.