Dacor IHL48 Installation Manual

Page 1
Installation Instructions
Integrated Hood Liner
Covers models IHL30, IHL36, IHL42, IHL48 and IHL48
Part No. 65268 Rev. D
Page 2
© 2007 Dacor ®, all rights reserved.
Page 3
Table of Contents
Important Safety Instructions ....................................... 1-2
Important Information About Safety Instructions .............. 1
General Safety Precautions ............................................. 2
Before You Begin...
Important:
Installer:• In the interest of safety and to minimize problems, read these installation instructions completely and carefully before you begin the installation process. Leave these installation instructions with the customer.
Customer:• Keep these installation instructions for future reference and the local electrical inspector’s use.
All specifications are subject to change without notice. Dacor
If you have questions or problems with installation, contact your Dacor For repairs to Dacor products under warranty, call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the product ready.
Dacor Customer Service
Phone: (800) 793-0093 (U.S.A. and Canada) Monday — Friday 6:00
Web site: www.Dacor.com
Dacor Distinctive Service (repairs under warranty only)
Phone: (877) 337-3226 (U.S.A. and Canada) Monday — Friday 6:00
Installation Planning ......................................................... 3
Electrical Connection ....................................................... 4
Installing the IVS .............................................................. 4
Verifying Proper Operation ............................................... 4
dealer or the Dacor Customer Service Team.
a.m. to 5:00 p.m. Pacific Time
a.m. to 4:00 p.m. Pacific Time
assumes no liability for changes to specifications.
Important Safety Instructions
Important Information About Safety Instructions
The • Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance.
Always contact the Dacor Customer Service Team • about problems and conditions that you do not understand.
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal injury or death.
WARNING
Hazards or unsafe practices that COULD result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor personal injury or property damage.
1
Page 4
Important Safety Instructions
General Safety Precautions
To reduce risk of fire, electric shock, serious injury or death when using your appliance, follow basic precautions, including the following:
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the 1. manufacturer. If you have questions, contact the manufacturer.
Before servicing or cleaning unit, switch power off 2. at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Exception: The additional safety instructions do not apply to a ceiling-suspended fan.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
Never leave surface units unattended at high 1. settings. Boil overs cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
Always turn hood ON when cooking at high heat or 2. when cooking flaming foods.
Clean ventilating fans frequently. Grease should not 3. be allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware 4. appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
SMOTHER FLAMES with a close-fitting lid, cookie 1. sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - You may be 2. burned.
DO NOT USE WATER, including wet dishcloths or 3. towels - a violent steam explosion will result.
Use an extinguisher ONLY if:4.
a) You know you have a Class ABC extinguisher,
and you already know how to operate it.
b) The fire is small and contained in the area where
it started.
c) The fire department is being called.
d) You can fight the fire with your back to an exit.
*Based on “Kitchen Fire Safety Tips” published by NFPA.
2
Page 5
Installation Instructions
21"
(53.3 cm)
4" (10.2 cm)
B
Model IHL42 IHL48 IHL54
(B) 39" (99.1 cm) 45" (114.3 cm) 51" (129.5 cm)
IVS2 mounting
studs (12 places)
IVS2 integrated
ventilation system
IHL mounting hole
(6 places)
13 7/16"
(34.1 cm)
C
L
13 7/16"
(34.1 cm)
21"
(53.3 cm)
4" (10.2 cm)
A
Model IHL30 IHL36
(A) 27" (68.6 cm) 33" (83.8 cm)
IVS1 mounting
studs (6 places)
IVS1 integrated
ventilation system
IHL mounting hole
(4 places)
C
L
Installation Planning
The Dacor integrated hood liner (IHL) is constructed with non-combustible stainless steel material. The IHL dimensions and design make it an excellent component for any custom hood structure. Dacor offers two integrated ventilation system products (IVS1 and IVS2) which conveniently install on the pre-mounted installation lugs around the opening at the top of the hood liner.
Plan the installation so that all minimum clearances are met or exceeded. Dimensions shown provide minimum clearances, unless otherwise noted.
NOTES:
Dacor IHLs have no electrical parts.•
#8 mounting screws (not provided) are required to • install the IHL. The length and type must be determined according to the application (mounting material). See the diagrams below to determine the quantity required for the model being installed.
For proper installation of the complete IHL/IVS custom • hood ventilation system, the installer must follow the installation information in the IVS Installation Instructions. Follow all electrical requirements specified in the IVS Installation Instructions.
The IVS is attached to the IHL using the 8-32 cap nuts • and lock washers provided with the IHL kit. Quantity varies according to kit.
The IHL is designed for vertical on center ducting • applications only.
The IHL30 and IHL36 liners are designed for installation with the 600CFM IVS1 integrated ventilation system. For additional specifications refer to the IVS Installation Instructions.
Figure 1: IHL30/36 Overall Dimensions
Top View
Figure 2: IHL42/48/54 Overall Dimensions
Top View
The IHL42, IHL48 and IHL54 liners are designed for installation with the 1200CFM IVS2 integrated ventilation system. For additional specifications refer to the IVS Installation Instructions.
3
Page 6
Installation Instructions
Electrical Connection
Refer to the IVS Installation Instructions.
Installing the IVS
Mount the IHL using #8 mounting screws (not 1. provided). See the diagrams on page 3 to determine the required quantity and type. Install them through the top of the liner.
Attach the IVS to the IHL mounting studs using the cap 2. nuts and lock washers included with the IHL kit.
Verifying Proper Operation
Refer to the IVS Installation Instructions.
NOTE: If the blower does not operate properly, follow these troubleshooting steps:
Verify that power is being supplied to the integrated 1. ventilation system.
Check the electrical connections to ensure that the 2. installation has been completed correctly.
If the appliance still does not work, contact Dacor 3. Distinctive Service at (877) 337-3226. Do not attempt to repair the appliance yourself. Have the model and serial numbers available when you call.
Dacor is not responsible for the cost of correcting problems caused by a faulty installation.
Custom hood
IHL
IHL mounting screw, number required varies with model, see page 3
IVS
Cap nuts/lock washers for mounting IVS (provided with IHL kit, quantity varies)
4
Page 7
Page 8
Dacor●600AntonBlvd.Suite1000CostaMesa,CA92626●Phone:(800)793-0093●Fax:(626)403-3130●www.Dacor.com
Loading...