Dacor IF48NBOL, EF48DBSS, EF42NBSS, IF42DBOL, IF48DBOL User Manual 2

...
Page 1
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
4"
(10.2 cm)
83
¹/2
" (212.1 cm) min.
84
³/4" (215 cm) max.
to bottom of solid soffit
24"
(60.96 cm) min.
77" (196 cm)
A
Width
(see chart following)
"
(1.3 cm)
1
/2
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
Op e n i n g Di m e n s i O n s
To avoid tipping during use, the solid soffit must be within 1” ◊ (2.5 cm) maximum above the refrigerator. If the solid soffit is higher than 1” (2.5 cm) or one is not available, then the refrigerator must be braced.
If the anti-tip boards are needed, they must be attached to the rear wall studs 80” to 90” (203 cm to 229 cm) above the floor. See installation instructions for more information.
NOTE:Aclearanceof¹⁄2” (1.3 cm) must be maintained above
the top grille in order for the top grille to be removed.
42” and 48” Wide
PLANNING
1/6
GUIDE
A grounded 3 prong electrical outlet should be placed within ◊ 4” (10.2 cm) of the right side cabinets or end panel. See Electrical Requirements for more information.
The water shutoff should be located in the base cabinet on ◊ either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall. See Water Supply Requirements for more information.
See Page 11.15
Model Series Cutout Width A
EF42, IF42 41½” (105.4 cm) to 41¾” (106.1 cm)
EF48, IF48 47½” (120.7 cm) to 47¾” (121.3 cm)
NOTE: Flooring under refrigerator must be at same level as the room. Face of cabinetry must be plumb.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
11.14
Page 2
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
Possible water line locations
Access hole within 1/2” (12.7 mm) of floor and rear wall
1"
(2.54 cm)
6"
(15.2 cm)
6"
(15.2 cm)
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
el e c t r i c a l re q u i r e m e n t s
The electrical circuit must meet all local codes and ordinances.
Recommended Grounding Method
A 115 Vac, 60 Hz., 15 or 20 Amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground Fault Circuit Interrupter) protected outlet, nuisance tripping of the power supply may occur, resulting in loss of cooling. Food quality and flavor may be affected.
42” and 48” Wide
PLANNING
2/6
Wa t e r su p p l y re q u i r e m e n t s
All installations must meet local plumbing code requirements.◊
The water shutoff should be located in the base cabinet on ◊ either side of the refrigerator or some other easily accessible area. The right-hand side is recommended. The access hole through the cabinet must be within ½” (12.7 mm) of the rear wall.
NOTE: If the water shut off valve is in the back wall behind the refrigerator, it must be at an angle so that the tube is not kinked when the refrigerator is pushed into its final position.
GUIDE
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Water Pressure
A cold water supply with water pressure between 30 and 120 psi (207 and 827 kPa) is required to operate the water dispenser and ice maker.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of
a reverse osmosis system going to the water inlet valve of the refrigerator needs to be between 30 and 120 psi (207 and 827 kPa). If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
Specifications are subject to change without notice. See installation instructions for additional details.
11.15
Page 3
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
130˚
130˚
90˚
90˚
110˚
110˚
47"
(119 cm
)
42
9
16 "
(108 cm)
23
¹4 "
(59 cm)
17
¹2 "
(44 cm)
38"
(97 cm)
41"
104 cm)
130˚
130˚
90˚
90˚
110˚
110˚
50¹2 "
(128 cm
)
45¹⁄4"
(115 cm)
26
³⁄4"
(68 cm)
19
³⁄4"
(50 cm)
40"
(102 cm)
43
¹2 "
110 cm)
Backer Panel
Overlay Panel
Spacer Panel
1
/4" (6.35 mm)
3
/4" (1.9 cm)
1" (2.5 cm)
1
/2" (1.3 cm)
1"
11/4"
1
1
/2"
1"
(2.5 cm)
1 (3.2 cm)
1
/4"
1 (3. 8 c m)
1
/2"
1
/2"
Refrigerator Side Trim
Door
Hinge
(2.5 cm)
(3.2 cm)
(3.8 cm)
(1.3 cm)
Cabinetry
3
/4"
(1.9 cm)
110˚ Door
Stop Position
1
/4" (6.35 mm)
3
/4" (1.9 cm)
1" (2.5 cm)
1
/2" (1.3 cm)
3
/4"
1"
1
1
/4"
1
1
/2"
1
/2"
Refrigerator Side Trim
Hinge
90° Door Stop Position
Backer Panel
Door
Overlay Panel
Door Swing 90˚ Actual Size
Refrigerator to Cabinetry Clearance
(1.9 cm)
(2.5 cm)
(3.8 cm)
(1.3 cm)
(3.2 cm)
Spacer Panel
Cabinetry
1
/2"
3
/4"
1"
(1.3 cm)
(1.9 cm)
(2.5 cm)
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
DO O r sW i n g Di m e n s i O n
The location must permit both doors to open to a minimum of 90°. Allow 4½” (11.4 cm) minimum space between the side of the refrigerator and a corner wall.
EF42 and IF42 Model Series
DO O r pa n e l s a n D ca b i n e t r y cl e a r a n c e ­iF42/iF48 se r i e s mO D e l s
The custom door panels and adjacent cabinetry for models series IF42 and IF48 must be designed so that there is sufficient clearance for the doors to swing open. If the refrigerator is to be installed close to the wall, see Door Swing 90°.
42” and 48” Wide
PLANNING
3/6
NOTE: More clearance may be required if you are using overlay panels, custom handles or extended handles on a IF series model.
To adjust the door swing, see the installation instructions.
EF48 and IF48 Model Series
Door Swing 90°
Refrigerator to Cabinetry Clearance
GUIDE
Door Swing 110°
Refrigerator to Cabinetry Clearance
NOTE: For IF Series models,
rout the hinge side of the custom door panels to a radius that is equal to at least half the thickness of the panel if a 130° door swing is desired. See the installation instructions.
When the doors are closed the refrigerator will extend beyond the face of the adjacent cabinetry to some degree.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Allow a minimum of 4½” (11.4 cm) of space between the side of the refrigerator and a corner wall. More clearance may be needed if thicker custom panels or custom handles are used. Do not overlook baseboards.
Specifications are subject to change without notice. See installation instructions for additional details.
11.16
Page 4
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
Overlay Panel
Spacer Panel
Backer Panel
5
/8" to 3/4"
(15.88 to
19.05 mm)
1
/8"
(3.18 mm)
1
/4"
(6.35 mm)
1" minimum (2.54 cm)
Door/Grille Trim
Spacer Panel
Offset Dimension
1
/8"
(3. 1 8 mm)
Top Grille
C
73/8"
(18.73 cm)
81/2"
(21.59 cm)
Offset
Bottom
Backer
1" (2.54 cm)
F
70¹⁄2" (179.07 cm)
70¹⁄2
"
(179.07 cm)
71¹⁄16 "
(180.50 cm)
35”
(88.90 cm)
E
D
B
Refrigerator Panel for
Freezer Panel for
Non-Dispenser Models all Models
Handle-Side
Offset
¹⁄8" (3.2 mm)
34³⁄8
"
(87.3 cm)
D
A
71¹⁄16
"
(180.50 cm)
47 ³⁄16
"
(119.86 cm)
D
Backer Bottom Offset
¹⁄8
"
(3.2 mm)
Backer Bottom Offset
¹⁄8
"
(3.2 mm)
Backer Bottom Offset
¹⁄8
"
(3.2 mm)
Freezer Panel for
Dispenser Models
A
12
"
(30.48 cm)
"
(59.53 cm)
7
1623
11
"
(282.58 cm)
¹⁄8
4
"
(107.95 cm)
¹⁄4
Handle-Side
Offset
¹⁄8" (3.2 mm)
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
cu s t O m pa n e l s a n D Ha n D l e s - iF42/iF48 se r i e s mO D e l s
Custom overlay panels used with models IF42 and IF48 allow you to blend the exterior of your refrigerator into the overall kitchen décor, and to use custom handles for additional design flexibility.
The custom panels must have backer panels attached in order to mount them to the refrigerator. It is most common to work with three panels, as shown in the graphic below. A decorative overlay panel, a ¹/8” (3.18 mm) spacer panel or spacer strips and a ¼” (6.35 mm) backer panel.
In some cases, your cabinet manufacturer may choose to work with one panel routed for the different dimensions. Follow these panel dimension and placement instructions to be sure that the custom overlay panels will fit properly.
42” and 48” Wide
PLANNING
4/6
IMPORTANT:
Install the panels after moving the refrigerator into place.
The weight of the overlay panels cannot exceed:
50 lbs (23 kg) for the refrigerator door.
30 lbs (13.5 kg) for the freezer door.
10 lbs (4.5 kg) for the top grille.
To minimize panel weight, you may use 2” (5.08 cm) spacer strips around the perimeter in place of full-sheet solid spacer panels. The spacer strips must be set in at least 1” (2.54 cm) from the top, bottom and sides edges of the backer panel. If you use spacer strips, it is also recommended that you use two 2” (5.08 cm) strips horizontally centered for added support.
NOTE: For the grille and the door panels to be flush, the overlay door panel should be ¼” (6.35 mm) thicker than the overlay grille panel.
GUIDE
Model Series
IF42 17¹⁄
IF48 19
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Decorative Overlay Panels
A B C
8” (43.50 cm) 23¹⁄8” (58.74 cm) 40½” (102.87 cm)
5
8” (49.85 cm) 265⁄8” (67.63 cm) 46½” (118.11 cm)
Model Series
IF42 16
IF48 19
Specifications are subject to change without notice. See installation instructions for additional details.
Backer Panels
D E F
7
⁄8” (42.86 cm) 227⁄8” (58.10 cm) 40½” (102.87cm)
3
⁄8” (49.21 cm) 26 3⁄8” (66.99 cm) 46½” (118.11 cm)
11.17
Page 5
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
23
1
2
"
(59.69 cm)
Overlay
³16 "
(4.5 mm)
³8 "
(9.7 mm)
¹⁄16 "
(1.5 mm)
¹8 "
(3.2 mm)
A
A
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
cu s t O m si D e pa n e l s - iF42/iF48 Inset Installation Dimensions
Custom side panels may be needed when not enough space is available to have cabinets on both sides of the refrigerator or when the refrigerator is placed at the end of a cabinet run. You may choose an Inset or Recessed Inset panel installation for models IF42 and IF48.
Measure the distance from point A (as shown) to the back wall. 1.
Add¹⁄32” (0.8 mm) to this measurement to allow the side panel
to fit into the trim.
Ifthepanelismorethan³⁄2. 8” (9.5 mm) thick, rout the front edge to allow the side panel to fit into the trim.
Refrigerator and Side Trim Dimensions
The width and height of a side panel are determined by the type of installation you are planning.
NOTES:
The dimensions shown are actual product dimensions and ◊ may not reflect the needed installation dimensions.
The side panel should be a minimum of ½” (1.27 cm) thick to ◊ avoid warping.
If the opening depth is 25” (63.5 cm) or more, you may want ◊ to install a support board on rear wall.
Back wall
Refrigerator
Recessed Inset Installation Dimensions
Measure the distance from point A (as shown) to back wall. 1.
Routethefrontedgeofthesupportboardorattacha³⁄2. 8” (9.5 mm) board to hold the panel in the cabinet side trim.
5/6
42” and 48” Wide
PLANNING
GUIDE
Side Trim
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Back wall
Specifications are subject to change without notice. See installation instructions for additional details.
11.18
Page 6
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
24¹⁄8
"
(61.3 cm)
23
½
"
(59.7 cm)
23¹¹⁄16
"
(60.3 cm)
¹¹⁄64
"
(4.5 mm)
¼
"
(6.35 mm)
³⁄16
"
(4.7 mm)
7
32
"
(5.5 mm)
¹³⁄32
" (10 mm)
5
8 "
(15.7 mm)
A
A
A
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
cu s t O m si D e pa n e l s - eF42/eF48
Custom side panels may be needed when not enough space is available to have cabinets on both sides of the refrigerator or when the refrigerator is placed at the end of a cabinet run. You may choose an inset, flush or recessed inset panel installation for models EF42 and EF48.
Refrigerator and Side Trim Dimensions
The width and height of a side panel are determined by the type of installation you are planning.
NOTES:
The dimensions shown are actual product dimensions and ◊ may not reflect the needed installation dimensions.
The side panel should be a minimum of ½” (1.27 cm) thick to ◊ avoid warping.
If the opening depth is 25” (63.5 cm) or more, you may want ◊ to install a support board on the rear wall.
Refrigerator
42” and 48” Wide
PLANNING
6/6
Inset Installation Dimensions
Measure the distance from point A (as shown) to the back 1. wall. Add 7⁄32” (5.6 mm) to this measurement to allow the side panel to fit into the trim.
If the panel is more than ¼” (6.35 mm) thick, route the front 2. edge to allow the side panel to fit into the trim.
Back wall
Flush Installation Dimensions
Measure the distance from point A (as shown) to the back 1. wall.
2.
Attach the support board with a screw or adhesive that is compatible with aluminum and wood.
GUIDE
Side Trim
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Back wall
Recessed Inset Installation Dimensions
Measure the distance from point A (as shown) to the back 1. wall.
2.
Route the front edge of the support board or attach a ¼” (6.35 mm) board to hold the panel in the cabinet side trim.
Back wall
Specifications are subject to change without notice. See installation instructions for additional details.
11.19
Loading...