Dacor IF48NBOL, EF48DBSS, EF42NBSS, IF42DBOL, IF48DBOL User Manual 2

...
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
4"
(10.2 cm)
83
¹/2
" (212.1 cm) min.
84
³/4" (215 cm) max.
to bottom of solid soffit
24"
(60.96 cm) min.
77" (196 cm)
A
Width
(see chart following)
"
(1.3 cm)
1
/2
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
Op e n i n g Di m e n s i O n s
To avoid tipping during use, the solid soffit must be within 1” ◊ (2.5 cm) maximum above the refrigerator. If the solid soffit is higher than 1” (2.5 cm) or one is not available, then the refrigerator must be braced.
If the anti-tip boards are needed, they must be attached to the rear wall studs 80” to 90” (203 cm to 229 cm) above the floor. See installation instructions for more information.
NOTE:Aclearanceof¹⁄2” (1.3 cm) must be maintained above
the top grille in order for the top grille to be removed.
42” and 48” Wide
PLANNING
1/6
GUIDE
A grounded 3 prong electrical outlet should be placed within ◊ 4” (10.2 cm) of the right side cabinets or end panel. See Electrical Requirements for more information.
The water shutoff should be located in the base cabinet on ◊ either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall. See Water Supply Requirements for more information.
See Page 11.15
Model Series Cutout Width A
EF42, IF42 41½” (105.4 cm) to 41¾” (106.1 cm)
EF48, IF48 47½” (120.7 cm) to 47¾” (121.3 cm)
NOTE: Flooring under refrigerator must be at same level as the room. Face of cabinetry must be plumb.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
11.14
EF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,
Possible water line locations
Access hole within 1/2” (12.7 mm) of floor and rear wall
1"
(2.54 cm)
6"
(15.2 cm)
6"
(15.2 cm)
IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL
Revised 04/22/08
el e c t r i c a l re q u i r e m e n t s
The electrical circuit must meet all local codes and ordinances.
Recommended Grounding Method
A 115 Vac, 60 Hz., 15 or 20 Amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground Fault Circuit Interrupter) protected outlet, nuisance tripping of the power supply may occur, resulting in loss of cooling. Food quality and flavor may be affected.
42” and 48” Wide
PLANNING
2/6
Wa t e r su p p l y re q u i r e m e n t s
All installations must meet local plumbing code requirements.◊
The water shutoff should be located in the base cabinet on ◊ either side of the refrigerator or some other easily accessible area. The right-hand side is recommended. The access hole through the cabinet must be within ½” (12.7 mm) of the rear wall.
NOTE: If the water shut off valve is in the back wall behind the refrigerator, it must be at an angle so that the tube is not kinked when the refrigerator is pushed into its final position.
GUIDE
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Water Pressure
A cold water supply with water pressure between 30 and 120 psi (207 and 827 kPa) is required to operate the water dispenser and ice maker.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of
a reverse osmosis system going to the water inlet valve of the refrigerator needs to be between 30 and 120 psi (207 and 827 kPa). If a reverse osmosis water filtration system is connected to your cold water supply, the water pressure to the reverse osmosis system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
Specifications are subject to change without notice. See installation instructions for additional details.