Dacor HPCT365GSNGH, HPCT304GSNGH Planning guide

Document # PG04-009
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
DYCT304G
Bottom of spill tray to
top of cooking surface
2 1/8” (5.4 cm)
30”
(76.2 cm)
DYCT304G, DYCT365G
®
Discovery
Drop-in Gas Cooktops
30” and 36” Wide
• Observe all governing codes and ordinances during planning and installation.
• Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Revised 12/14/15 Page 1/4
PLANNING
GUIDE
WARNING
Chassis height
4”
(10.2 cm)
21”
(53.3 cm)
19 1/2” *
(49.5 cm)
DYCT365G
Bottom of spill tray to
top of cooking surface
2 1/8” (5.4 cm)
21”
(53.3 cm)
27 1/2” *
* Including raised embosses on sides of chassis
(69.9 cm)
36”
(76.2 cm)
* Including raised embosses on sides of chassis
33 5/8” *
(85.4 cm)
Chassis height
4”
(10.2 cm)
19 1/2” *
(49.5 cm)
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
4.10
Document # PG04-009
Top panel overhang
DYCT304G, DYCT365G
®
Discovery
Drop-in Gas Cooktops
30” and 36” Wide
Revised 12/14/15 Page 2/4
PLANNING
GUIDE
Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner’s responsibility to make sure that the electrical service meets electrical require­ments and that the electrical outlet has been properly installed.
◊ The cooktop is supplied with a factory installed, 40-inch power cord
with a, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagram below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.
◊ The electrical installation, including minimum supply wire size and
grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from:
National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101
◊ The correct voltage, frequency and amperage must be supplied to
the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference.
◊ Be certain to locate the electrical outlet so that the power may be
easily disconnected if the unit needs service.
Gas Supply Requirements
◊ Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number listed
on the product data label. See the Chassis Bottom Diagram for label location.
◊ Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping
carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.
◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the
cooktop itself is equipped with a 3/4” male NPT fitting.
◊ The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data on the product data label.
◊ The gas supply pressure for testing the regulator setting shall be
at least 1 inch water column (249 Pa) above the specified manifold pressure.
MODEL
Gas type Natural LPG
Manifold pressure
Min. gas supply Pres­sure**
Max. gas supply pres­sure
Total connected load 0.25 Amp. (0.03 kW) 0.25 Amp. (0.03 kW)
Circuit requirement
GAS AND ELECTRICAL REQUIREMENTS
UNDERNEATH
COOKTOP: DYCT304G
Power cord
Chassis
UNDERNEATH
COOKTOP: DYCT365G
DYCT304G/NG DYCT365G/NG
5” Water column 10” Water column
6” Water column 11” Water column
1/2 psi 1/2 psi
120 Vac,
60 Hz, 15 Amp.
Front of cooktop
2 1/8”
(5.4 cm)
3 3/4”
(9.5 cm)
Front of cooktop
Gas inlet
DYCT304G/LP DYCT365G/LP
120 Vac,
60 Hz, 15 Amp.
5/8”
(1.6 cm)
13/16”
(2.1 cm)
Gas inlet
Power cord in
2 1/4”
Chassis
(5.7 cm)
1 3/8”
(3.5 cm)
1”
1”
(2.5 cm)
(2.5 cm)
All specications subject to change without notice.