Dacor HIPR30S, HIPR36S, HIPR36C Planning guide

HIPR30S, HIPR36S
Heritage
®
Induction Pro Range
WARNING
• Follow local codes/ordinances during planning and installation. (Contact the local building department for details.)
• The range must be installed per its installation instructions. Dacor is not responsible for product damage/failure due to faulty installation.
Critical Depth/Height
Dimensions
Doc #: PGH-HIPR.01 Revised 11 Oct 2018 Page 1 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
PLANNING
GUIDE
Range Only Range With Downdraft
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
HIPR30S, HIPR36S
Heritage
®
Induction Pro Range
ELECTRICAL REQUIREMENTS
Model Required Circuit Total Connected Load
HIPR30, HIPR36 240 Vac*, 60 Hz, 50 Amp. 11 – 9 kW (49.5 Amp.)
*4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are for reference only; see the data label (back of range) for exact specications.
The wiring must be long enough that the range can be pulled out
for service, without being disconnected. Wiring to the range must:
• meet NEMA standards and the requirements in the above table
• include a strain relief
be terminated by tinned leads, closed-loop terminals, or open- ended spade lugs with upturned ends
• connect to a junction box or receptacle installed by a licensed electrician.
The range may be connected via one of these two methods:
4-wire conduit connected to a 4-wire junction box
3-wire conduit (where local code permits, not for use with new
branch circuit installations) connected to a 3-wire junction box.
Using a power cord:
A 4-wire power cord with a NEMA 14-50P plug connected to a
NEMA 14-50R receptacle:
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
Page 2 of 3
PLANNING
GUIDE
ELECTRICAL-ACCESS DIMENSIONS
Model A B* C**
A 3-wire power cord (where permitted) with a NEMA 10-50P plug connected to a NEMA 10-50R receptacle
The power-cord plug must be UL listed type SRD or SRDT.
Range models DYRP36D-C-S and DYRP48D-C-S come with a
factory installed 4-wire appliance cord with NEMA 14-50P plug. For freestanding ranges installed in Canada, a factory installed 4-wire appliance cord with NEMA 14-50P plug is required,
without modification.
HIPR30 6 ¾" (17.1 cm)
6 ¾ (17.1 cm) ” (2.2 cm) dia.
HIPR36 12” (30.5 cm)
*Range legs adjusted to lowest height; **hole size may be increased to 1 ” (2.9
cm) by removing conduit bracket in bottom of electrical box.
Electrical Service Inlets
• Existing utilities may be used if they meet the spec's in this manual.
• The circuit-breaker panel/fuse box must be accessible without moving the range.
• Junction box/receptacle must not impede placement of the range.
• Locate the junction box so the range can be pulled out for service without being disconnected.
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093