HIPR30S, HIPR36S
Heritage
®
Induction Pro Range
WARNING
• Follow local codes/ordinances during planning and installation.
(Contact the local building department for details.)
• The range must be installed per its installation instructions. Dacor is
not responsible for product damage/failure due to faulty installation.
Critical Depth/Height
Dimensions
Doc #: PGH-HIPR.01 Revised 11 Oct 2018 Page 1 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
30” and 36” Wide,
PLANNING
GUIDE
Range Only Range With Downdraft
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
HIPR30S, HIPR36S
Heritage
®
30” and 36” Wide,
Induction Pro Range
ELECTRICAL REQUIREMENTS
Model Required Circuit Total Connected Load
HIPR30, HIPR36 240 Vac*, 60 Hz, 50 Amp. 11 – 9 kW (49.5 Amp.)
*4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are
for reference only; see the data label (back of range) for exact specications.
The wiring must be long enough that the range can be pulled out
for service, without being disconnected. Wiring to the range must:
• meet NEMA standards and the requirements in the above table
• include a strain relief
• be terminated by tinned leads, closed-loop terminals, or open-
ended spade lugs with upturned ends
• connect to a junction box or receptacle installed by a licensed
electrician.
The range may be connected via one of these two methods:
• 4-wire conduit connected to a 4-wire junction box
• 3-wire conduit (where local code permits, not for use with new
branch circuit installations) connected to a 3-wire junction box.
Using a power cord:
• A 4-wire power cord with a NEMA 14-50P plug connected to a
NEMA 14-50R receptacle:
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
Page 2 of 3
PLANNING
GUIDE
ELECTRICAL-ACCESS DIMENSIONS
Model A B* C**
• A 3-wire power cord (where permitted) with a NEMA 10-50P
plug connected to a NEMA 10-50R receptacle
• The power-cord plug must be UL listed type SRD or SRDT.
• Range models DYRP36D-C-S and DYRP48D-C-S come with a
factory installed 4-wire appliance cord with NEMA 14-50P plug.
For freestanding ranges installed in Canada, a factory installed
4-wire appliance cord with NEMA 14-50P plug is required,
without modification.
HIPR30 6 ¾" (17.1 cm)
6 ¾ (17.1 cm) ” (2.2 cm) dia.
HIPR36 12” (30.5 cm)
*Range legs adjusted to lowest height; **hole size may be increased to 1 ” (2.9
cm) by removing conduit bracket in bottom of electrical box.
Electrical Service Inlets
• Existing utilities may be used if they meet the spec's in this
manual.
• The circuit-breaker panel/fuse box must be accessible
without moving the range.
• Junction box/receptacle must not impede placement of
the range.
• Locate the junction box so the range can be pulled out for
service without being disconnected.
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093