Dacor HGER48S, HGER36S User Manual

HGPR36S, HGPR48S
Heritage
WARNING
Observe all governing codes and ordinances during planning and installation. Contact your local building department for details.t
The range must be installed as specified in its installation instructions.
WIDTHS
HGPR36S
35 ” (91.1 cm)
HGPR48S
47 ” (121.6 cm)
®
36”, 48” Wide
Gas Pro Range
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
PLANNING
GUIDE
Range Downdraft Vent
HGPR36S MRV36-ER
HGPR48S MRV48-ER
Range 1.5” Low-Prole Backguard
HGPR36S APB36GLP
HGPR48S APB48GLP
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
B
A
HGPR36S, HGPR48S
Heritage
®
36”, 48” Wide
Gas Pro Range
Page 2 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
PLANNING
GUIDE
WARNING
Observe all governing codes and ordinances during planning/ installation. Contact your local building department for details.
To prevent electric shock, the power supply must meet the specifications stated below. The owner shall ensure the electrical service meets requirements and that the outlet is properly installed/ inspected by a licensed electrician.
The range must be electrically grounded according to local codes or, in their absence, with the National Electrical Code, ANSI/ NFPA 70.
Electrical Requirements
The range is supplied with a factory installed, 6-ft. long power cord with a 3-prong grounding plug. It is connected to the chassis at the rear of the range. It must be connected to a dedicated, grounded 3-prong electrical outlet.
The correct voltage, frequency and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse.
Model Circuit Required Total Connected Load*
HGPR36S 120 Vac, 60 Hz, 15 Amp. 120 Vac 60 Hz, 5.0 Amp.
HGPR48S 120 Vac, 60 Hz, 15 Amp. 120 Vac 60 Hz, 8.0 Amp.
*These figures are for reference only. See the rating label for exact specifications.
Gas-Supply Requirements
Installation of this range must conform to local codes or, in their absence, to the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
The range being installed must match the home gas service (natural or LP gas).
If using the range above 4000 ft. (1219 m) altitude, ensure it is equipped for high-altitude use. See the rating label and graphic on the inside front cover to verify the correct model.
This table has gas-supply pressure requirements:
GAS-SUPPLY PRESSURE REQUIREMENTS*
Gas Type
Natural Gas 5” Water Column 6” Water Column
Liquid Propane (LP) 10” Water Column 11” Water Column
*The gas-supply pressure for testing the regulator setting shall be at least 1” water column (249 Pa) above the specified manifold pressure’; **max. gas supply pressure for all models: 1/2 psi; the ratings above are for reference only. See the rating label for exact specifications.
Use only the factory-installed regulator. The regulator inlet receives a 3/4” gas line. The range ships with a 1/2”-to-3/4” adapter connected to the regulator.
Min. Manifold
Pressure
Minimum Gas-Supply
Pressure**
Rating Label
Power
Gas Inlet
GAS-/ELECTRICAL-ACCESS DIMENSIONS
Model A B
HGPR36S 13 ¹/₁₆” to 14 ” (33.2 to 36.5 cm) 7 ⁵/₁₆” (18.6 cm)
HGPR48S 13 ¹/₁₆” to 14 ” (33.2 to 36.5 cm) 4 ” (10.8 cm)
cord
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093