Dacor HDER30CNG, HDER36SLPH Planning guide

Page 1
HDPRS/HDERS
Heritage
WARNING
Observe all governing codes and ordinances during planning and installation. Contact your local building department for details.t
The range must be installed as specified in its installation instructions.
Critical Depth/Height Dimensions
HDPRS model shown; common dimensions given;
unique HDPS/HDERS dimensions indicated
®
30”, 36”, 48” Wide,
Dual-Fuel Ranges
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
PLANNING
GUIDE
Range-With-Downdraft InstallationRange-Only Installation
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Page 2
HDPRS/HDERS
Heritage
Dual-Fuel Ranges
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
®
30”, 36”, 48” Wide,
Page 2 of 3
PLANNING
GUIDE
ELECTRICAL REQUIREMENTS
Model Required Circuit Total Connected Load
HDPR30S, HDER30S
240 Vac*, 60 Hz, 30 Amp. 5.75 kW (24.0 Amp.)
HDPR36S, HDER36S
HDPR48S, HDER48S 240 Vac*, 60 Hz, 50 Amp. 10.1 kW (41.9 Amp.)
*4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground; these ratings are for reference only; see the range's data label (back of range) for exact specications.
The wiring must be long enough that the range can be pulled out for service, without being disconnected. Wiring to the range must:
meet NEMA standards and the requirements in the above table
include a strain relief
be terminated by tinned leads, closed-loop terminals, or open-
ended spade lugs with upturned ends
connect to a junction box or receptacle installed by a licensed electrician.
The range may be connected via one of these two methods:
4-wire conduit connected to a 4-wire junction box
3-wire conduit (where local code permits, not for use with new
branch circuit installations) connected to a 3-wire junction box.
Using a power cord:
A 4-wire power cord with a NEMA 14-50P plug connected to a NEMA 14-50R receptacle:
MINIMUM GAS-SUPPLY PRESSURE REQUIREMENTS*
Gas Type Min. Manifold Pressure Min. Gas-Supply Pressure**
Natural 5” water column 6” water column
LP (propane) 10” water column 11” water column
*Gas-supply pressure for testing the regulator setting shall be at least 1” water column (249 Pa) above the specied manifold pressure; **Max gas-supply pres­sure, all models:  psi. The above ratings are for reference only; see the rating label (upper-rear of range) for exact specications.
A 3-wire power cord (where permitted) with a NEMA 10-50P plug connected to a NEMA 10-50R receptacle
The power-cord plug must be UL listed type SRD or SRDT.
Range models DYRP36D-C-S and DYRP48D-C-S come with a
factory installed 4-wire appliance cord with NEMA 14-50P plug. For freestanding ranges installed in Canada, a factory installed 4-wire appliance cord with NEMA 14-50P plug is required, without modification.
48” model shown
GAS-/ELECTRICAL-ACCESS DIMENSIONS
Model A B* C D* E**
HDPR30S/
HDER30S
HDPR36S/
HDER36S
HDPR48S/
HDER48S
*Measurement with range legs adjusted to their lowest height; **the hole size for the electrical wiring may be increased to 1 ” (2.9 cm) by removing the conduit bracket in the bottom of the electrical box.
3 ¼"
(8.3 cm)
6 "
(17.1 cm)
4 ”
(10.8 cm)
27”
(68.6 cm)
27”
(68.6 cm)
27”
(68.6 cm)9”(22.9 cm)
6 "
(17.1 cm)
12”
(30.5 cm)
6 
(17.1 cm)
”
(2.2 cm)
dia.
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Page 3
HDPRS/HDERS
Heritage
Dual-Fuel Ranges
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
®
30”, 36”, 48” Wide,
Page 3 of 3
PLANNING
GUIDE
Cabinet Layout
All maximum/minimum dimensions and clearances in the diagrams below must be maintained for safe operation.
Place the range away from drafts (open doors and windows, and home heating/cooling systems).
Do not install cabinets over the range, or to reduce risk of burn injury from reaching over a hot cooktop, install a range hood that projects horizontally at least 5” beyond the cabinet bottoms.
The range may be installed against the rear wall. Dacor strongly recommends installing a backguard or non-combustible material on the rear wall between the range vent hood.
CUTOUT DIMENSIONS
Model F: recommended/min. G: min./max. H
HDPRS/HDERS 30 36” (91.4 cm) / 30” (76.2 cm) 30” (76.2 cm) / 30 ” (76.5 cm) 27 " (69.5 cm)
HDPRS/HDERS 36 42” (106.7 cm) / 36” (91.4 cm) 36” (91.4 cm) / 36 ” (91.8 cm) 33 ” (84.8 cm)
HDPRS/HDERS 48 54” (137.2 cm) / 48” (122.0 cm) 48” (121.9 cm) / 48 ” (122.2 cm) 43 ” (110.5 cm)
Seal openings in the wall behind the range and in the floor below.
The grey area in the diagram below shows the suggested gas/
electrical utilities. Existing utilities may be used if they do not hinder range placement.
Gas/electrical utilities must be located so the range can be moved for service without being disconnected.
An external, manual shut-off valve must be installed between the gas inlet and range so gas to the range can be shut on/off.
Installation must allow access to the gas shut-off valve and circuit-breaker panel/fuse box when the range is in place.
Standard Cutout with Range Hood
APPROVED DOWNDRAFT VENTS
Range Downdraft Vent
HDPRS/HDERS 30 MRV30-ER
HDPRS/HDERS 36 MRV36-ER
HDPRS/HDERS 48 MRV48-ER
IMPORTANT: See downdraft installation instruc­tions for duct and electrical installation require­ments. Use only approved Dacor downdraft vents.
Countertop Cutout For Downdraft Vent
1. Vertical from range grate level to combustible overhead surface; if install-
ing an overhead hood, see hood specications for minimum required clearances.
2. Cabinet/countertop depth is at customer discretion, but cabinet face must
not protrude beyond rear of range front panel. (See Pg. 1 for dimensions.)
3. Consult local codes for exact location requirements.
4. Vertical from grate level to combustible surface.
5. Not applicable to cabinets that horizontally are over 10” (25.4 cm) from
range edge.
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093