RNCT305G, RNCT365G
Front of unit
Power cord
42” (106.7 cm) long
1/2” male
NPT gas inlet
Side View
Rear
overhang
Front
overhang
19 9/32” (49.0 cm)
17/32”
(1.3 cm)
1 3/16
”
(3.0 cm)
Front View
B
1 11/32”
(3.4 cm)
1 11/32”
(3.4 cm)
Document # PG04-011
Renaissance
Drop-in Gas Cooktops
WARNING
• Observe all governing codes and ordinances during planning
and installation.
• Contact your local building department for further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
Product tolerances ±1/16” (±1.6 mm) unless otherwise
®
30” and 36” Wide
Revised 0706/16 Page 1/4
PLANNING
GUIDE
2" (5.1 cm)
from countertop
to cooking surface
4" (10.2 cm)
chassis height
Model A B
RNCT305G 30” (76.2 cm) 27 5/16” (69.4 cm)
RNCT365G 36” (91.4 cm) 33 5/16” (84.6 cm)
A
21"
(53.3 cm)
Product dimensions
Front of cooktop
UTILITY LOCATIONS UTILITY DIMENSIONS
All specications subject to change without notice.
Power
cord
1 3/4”
(4.4 cm)
1/2” male NPT
gas inlet*
Chassis
1 3/4”
(4.4 cm)
*Gas inlet extends 1” (2.5 cm) from bottom
2”
(5.1 cm)
Top panel overhang
Phone: (800) 793-0093www.dacor.com
4.18
Document # PG04-011
RNCT305G, RNCT365G
®
Renaissance
Drop-in Gas Cooktops
30” and 36” Wide,
Revised 07/06/16 Page 2/4
PLANNING
GUIDE
Electrical Requirements
WARNING
To prevent an electric shock hazard, the power supply must meet
the specifications stated below. It is the owner’s responsibility
to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by
a licensed electrician.
◊ The cooktop is supplied with a factory installed, 42 inch power cord
with a, three-prong, grounding electrical plug. It is connected to
the chassis at the bottom right rear corner (see Chassis Bottom
Diagram below). It must be connected to a dedicated, grounded
three-prong electrical outlet installed by a licensed electrician.
◊ The electrical installation, including minimum supply wire size and
grounding, must be done in accordance with National Electric Code
ANSI/NFPA 70* and local codes and ordinances. A copy of this
standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
◊ The correct voltage, frequency and amperage must be supplied to
the electrical outlet according to the product data label located on the
bottom of the chassis. See the Gas and Electrical Requirements table
on this page for reference.
◊ Be certain to locate the electrical outlet so that the power may be
easily disconnected if the unit needs service.
Front of unit
Product data label
CHASSIS BOTTOM DIAGRAM
Gas Supply Requirements
◊ Be certain that the cooktop being installed is correct for the gas
service being provided (natural gas or LP gas). Also, if operating
the cooktop at an altitude above 4000 ft. (1219 m) make sure it is
equipped for high altitude operation.
◊ Units equipped for LP operation have “LP” in the model number listed
on the product data label. See the Chassis Bottom Diagram for label
location.
◊ Units equipped for high altitude operation have an “H” at the end of
the model number listed on the product data label.
◊ Check your local building codes for the proper method of installation.
In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.
◊ An external manual shut-off valve must be installed between the gas
inlet and the cooktop for the purpose of turning on or shutting off gas
to the appliance.
◊ The cooktop comes from the factory with a regulator in the shipping
carton. Use only the regulator provided. The regulator must be
installed in the gas line that runs from the cooktop gas inlet to the gas
shut off valve.
◊ The regulator inlet accommodates a 3/4” gas line. The inlet to the
cooktop itself is equipped with a 3/4” male NPT fitting.
The cooktop gas connection is located on the bottom of the cootktop in the
back right corner as you face the front of the unit. See the Chassis Bottom
Diagram on this page.
RNCT305G_NG
RNCT365G_NG
Gas type Natural Gas LP Gas
Manifold
pressure
Min. gas supply
Pressure**
Max. gas supply
pressure
Total connected load
Circuit requirement
GAS AND ELECTRICAL REQUIREMENTS*
* The electrical and gas data on this page is for reference only. If the
above data does not agree with the product data label, use the data on the
product data label.
** The gas supply pressure for testing the regulator setting shall be at least
1 inch water column (249 Pa) above the specified manifold pressure.
5” water column 10” water column
6” water column 11” water column
1/2 psi 1/2 psi
0.25 Amp.
(30 Watts)
120 Vac,
60 Hz, 15 Amp.
RNCT305G_LP
RNCT365G_LP
0.25 Amp.
(30 Watts)
120 Vac,
60 Hz, 15 Amp.
All specications subject to change without notice.