• For safety reasons and to minimize problems, read this Installation Instruction manual thoroughly before installing the appliance.
• Leave the Installation Instructions manual with the consumer.
• Write the Product Data Label information in the Use and Care manual for the consumer’s reference.
Consumer
Keep the Installation Instructions manual for reference and for the local electrical inspector’s use.
Note: Dacor
®
is not responsible for service required to correct a faulty installation.
Customer Assurance Information
If You Need Help…
…with installation and warranty questions and issues, contact
your Dacor dealer or Dacor Customer Assurance.
When you call, have available the cooktop model and serial numbers, which are on the data label (see right; you may also want to
write the numbers in this manual).
Dacor Customer Assurance
Phone: 833-35-ELITE (833-353-5483) USA, Canada
M – F, 5:00 a.m. to 5:00 p.m. Pacific Time
Website: www.dacor.com/customer-care/contact-us
Data Label
The cooktop data label (on the underside of the chassis), features
the appliance model/serial numbers, and electrical-/gas-supply
requirements.
Front of unit
Product data label
All specifications are subject to change without notice. Dacor assumes no liability for such changes.
• The Important Safety Instructions and warnings in this manual
cannot cover all possible conditions. Use common sense and
caution when installing/maintaining/operating the cooktop.
• Always contact Dacor Customer Assurance (see info, previous
page) about issues you cannot resolve.
Safety Symbols, Labels, and Alerts
These inform you of the risk of death or serious injury.
DANGER
Immediate hazard that WILL severely injure or kill.
WARNING
Hazard/unsafe practice that COULD severely injure or kill.
WARNING
IN CASE OF GREASE FIRE:
• (TAKING CARE NOT TO BURN YOURSELF) Smother flames with a
close-fitting lid, cookie sheet, or metal tray, then turn off the burner. If flames do not extinguish immediately, EVACUATE, AND CALL
THE FIRE DEPARTMENT.
• NEVER PICK UP A FLAMING PAN.
• DO NOT USE WATER (incl. wet dishcloths/towels); a violent steam
explosion may result.
• Use a fire extinguisher ONLY if:
– it is a Class ABC extinguisher that you know how to use– the fire is small and contained in its area of origin– the fire department is being called– you can fight the fire with your back to an exit.
POWER OUTAGES
Do not try to use the cooktop during a power outage.
CALIFORNIA PROPOSITION 65 WARNING
Burning gas emits by-products known by the state of California to
cause cancer/reproductive harm. State law requires businesses to
warn customers of potential exposure to such substances. To
minimize exposure, ensure good ventilation, and follow instructions in
the User Manual.
WARNING
• Do not store or use combustible or explosive vapors/liquids/
materials on or near the cooktop.
• Installation and service must be performed by a qualied technician,
service agency, or gas supplier.
• If you smell gas:
− Do not use or light any appliance.
− Do not touch electrical switches or use any electrical devices
(including the telephone) in your building.
− From a neighbor’s home, immediately call the gas supplier, and
follow their instructions.
− If you cannot contact the gas supplier, call the fire department.
AVERTISSEMENT
• Ne stockez pas et n’utilisez pas de vapeurs/liquides/matériaux
combustibles ou explosifs sur ou près de la table de cuisson.
• L’installation et l’entretien doivent être effectués par un technicien
qualié, une agence de service ou un fournisseur de gaz.
• Si vous sentez une odeur de gaz:
− Ne pas utiliser ou allumer un appareil électrique.
− Ne touchez pas aux interrupteurs électriques et n’utilisez aucun
appareil électrique (y compris le téléphone) dans votre immeuble.
− De la maison d’un voisin, appelez immédiatement le fournisseur
de gaz, et suivez leurs instructions.
− Si vous ne pouvez pas contacter le fournisseur de gaz, appelez les
pompiers.
WARNING
Do not use the cooktop as a space heater, which may lead to carbon
monoxide poisoning and overheating of the appliance.
AVERTISSEMENT
N’utilisez pas la table de cuisson comme appareil de chauffage, ce qui
pourrait entraîner un empoisonnement au monoxyde de carbone et
une surchauffe de l’appareil.
WARNING
Do not cover slots, holes, or vents. Blocking air flow may cause carbon
monoxide poisoning. Aluminum-foil linings may trap heat, causing a
fire hazard. Keep all cooktop passages clear of grease/grime.
AVERTISSEMENT
Ne couvrez pas les fentes, les trous ou les évents. Le blocage du flux d’air
peut provoquer un empoisonnement au monoxyde de carbone. Les
revêtements en aluminium peuvent emprisonner la chaleur et provoquer
un incendie. Gardez tous les passages de la table de cuisson exempts de
graisse / saleté.
READ AND SAVE THESE INSTRUCTIONS
1
Important Safety Instructions
General Safety Precautions
To promote household safety when using the cooktop, follow basic safety precautions, including these precautions:
WARNING
• Read the cooktop use and care manual completely before operating this appliance.
• Keep packaging materials away from children. (Plastic sheets/bags are suffocation hazards.)
• If you receive a damaged product, immediately contact your dealer/builder. Do not install/use a damaged appliance.
• This cooktop must be properly installed and grounded by a qualified installer per these instructions before use. The installer
should show the customer the gas shut-off valve and power cord so they know where/how to turn off the gas supply and disconnect power to the cooktop.
• Do not install/repair/replace any cooktop component unless specifically recommended in the accompanying literature. A qualified technician should perform all other service.
• Before service/installation, turn off the gas supply at the gas-supply valve and unplug the power cord.
• Unplug the power cord before cleaning. (For cleaning instructions, see the User Manual.)
• Use the cooktop for cooking tasks consistent with a home appliance per the accompanying literature. (The cooktop is for home
use only.)
• DO NOT TOUCH THE COOKTOP SURFACE DURING/IMMEDIATELY AFTER USE.
• Do not operate the cooktop if its power cord is damaged.
• Turn OFF the knobs before removing them from the valve stems.
• Clean the cooktop fully before operating it the first time; verify that all cooktop parts are dry before lighting a burner.
• Do not hang flammable or heat-sensitive objects above the cooktop.
• Do not climb/stand/kneel on the appliance.
• Do not leave the cooktop unattended while in use.
• Do not leave children unattended near the cooktop or let children play with/climb on the cooktop; do not store items of interest
to children on/above the cooktop.
• Keep flammable items (e.g., paper, cardboard, plastic, cloth) away from the cooktop. Do not let potholders touch hot surfaces or
gas burners.
• Do not wear loose or hanging apparel while using the cooktop. Do not let clothing touch the cooktop and surrounding areas during and immediately after use.
• If the cooktop is near a window, do not hang long curtains that could blow over the hot cooktop.
• Do not use towels or bulky cloth as pot holders.
• Do not heat closed/sealed containers on the cooktop. (The container may explode, causing personal injury.)
• When heated, non-stick coatings can harm birds. When using non-stick cookware, move pet birds to a separate, well-ventilated
room.
The cooktop has a three-prong grounding plug to prevent possible electric shock. Plug it in a dedicated, grounded three-prong
outlet. (The customer shall ensure the proper outlet is installed.)
• DO NOT cut/remove the third (ground) prong from the power cord.
• DO NOT use an adapter plug or extension cord.
• DO NOT use a frayed/damaged power cord.
• DO NOT plug in to an outlet with a ground fault interrupter (GFI).
2
Important Safety Instructions
Electrical Requirements
WARNING
To avoid an electric shock hazard, the power supply must meet the
specifications below. The owner shall ensure the electrical service
meets the requirements in this section and the outlet is installed by a
licensed electrician.
• A 42” power cord with a 3-prong, grounding plug is attached
to the chassis’ bottom in the right-rear corner. You must insert
the plug in a dedicated, grounded 3-prong electrical outlet
installed by a licensed electrician.
HCT305G/-365G (bottom)
• The electrical installation, including minimum-supply wire size
and grounding, must be done according to National Electric
Code ANSI/NFPA 70* and local codes and ordinances. You may
obtain a copy of this standard from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
• The correct voltage, frequency, and amperage must be
supplied to the electrical outlet according to the product
data label on the chassis bottom. (See the Gas/Electrical
Requirements table on this page.)
• Position the electrical outlet so the power cord may be easily
disconnected if the unit needs service.
Gas-Supply Requirements
• Verify that the cooktop matches your provided gas service
(natural gas or liquid propane).
• If using the cooktop above 4000 ft. (1219 m) elevation, ensure
it is equipped for high-altitude operation. (Such units have
an “H” at the end of their model number on the product-data
label; see the Product Data Label section.)
• Units equipped for liquid-propane have “LP” in the model number on the product-data label.
• Check local building codes for the proper installation method.
If no local code exists, follow National Fuel Gas Code ANSI
Z223.1/NFPA 54.
• An external, manual shut-off valve must be installed between
the gas-supply line and the cooktop so gas to the cooktop can
be shut on/off.
• Use only the provided regulator, which must be installed
between the cooktop gas inlet and the gas shut-off valve.
• Because the regulator inlet accommodates a 3/4” gas line, and
the cooktop inlet is a 1/2” male NPT fitting, a 3/4”-to-1/2” reducer is included with the cooktop. (See HCT305G/-365G at left.)
Gas/Electrical Requirements*
HCT305G_NG
HCT365G_NG
Gas TypeNatural gasLiquid propane
Manifold Pressure5” Water column10” Water column
Min. Gas-Supply Pressure**6” Water column11” Water column
Max. Gas-Supply Pressure1/2 psi
Total Connected Load0.25 Amp. (30 Watts)
Circuit Requirement120 Vac, 60 Hz, 15 Amp.
*This gas/electrical data is for reference only. If this data conflicts with the
product-data label, use the data on the label.
**The gas-supply pressure for testing the regulator setting shall be at least
1-in. water column (249 Pa) above the specified manifold pressure.
HCT305G_LP
HCT365G_LP
3
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.