Dacor ERV3015 User Manual

Rear wall or countertop edge
countertop opening
29 1/4” (74.3 cm)
raised vent opening
27 1/2” (69.9 cm)
30 1/16” (76.2 cm)*
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
to width of cabinets
3/8” min. (1.0 cm)
countertop overhang
1” min. (2.6 cm) to any combustibles above counter both sides
23 3/8”
(59.4 cm)
2 5/8” (6.7 cm)
25”
(63.5 cm)
max.
Countertop front
Cabinet face
Countertop
Range trim resting
on countertop
RR30NI[F]S range
3/8” min. (1.0 cm) flat countertop overhang
27 9/16” (70.0 cm)
ERV30[15] raised vent
3/8” min. (1.0 cm) space required behind ERV30[15] chassis to clear stiffener
ATKR30SR trim kit installed
Cabinet face
Countertop
Range trim resting
on countertop
Back of side panel rests against cabinet face
RR30NI[F]S range
3/8” min. (1.0 cm) flat countertop overhang
ATKR30SR trim kit installed
27 9/16” (70.0 cm)
3 inch side panel
ERV30[15] raised vent
3/8” min. (1.0 cm) space required behind ERV30[15] chassis to clear stiffener
Document # PGCI-029
COMBINATION INSTALLATIONS
Revised 03/21/13 Page 1/1
RR30NI[F]S Range with ERV3015
Raised Vent
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
Countertop height: 34 3/4” (88.3 cm) min., 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max.
Trim kit PN ATKR30SR is required for proper installation of a raised vent with this range.
The self-rimming installation of the RR30NI[F]S range and ERV30[15] raised vent create a “built-in” look where the range trim overlaps the countertop on both sides and the raised vent trim overlaps the countertop in back.
IMPORTANT: When installing the range in this configuration, ventilation must be provided to allow for cooling of the ranges internal components. See diagram, left.
1” min. (2.6 cm) to any combustibles above counter both sides
25”
(63.5 cm)
max.
Countertop front
countertop opening
to width of cabinets
Rear wall or countertop edge
27 1/2” (69.9 cm)
29 1/4” (74.3 cm)
30 1/16” (76.2 cm)
cabinet opening
below countertop
Notch countertop
Cabinet face
below countertop
3/8” min. (1.0 cm)
countertop overhang
20 3/8”
(51.8 cm)
(51.8 cm)
(59.4 cm)
2 5/8” (6.7 cm)
20 3/8”
to
23 3/8
TOP
VIEW
PLANNING
GUIDE
Observe all vertical cabinet clearances on specified on the RR30NI Planning Guide sheet..
A self-rimming countertop configuration is required for raised vent installation. On installations with a raised vent, when sliding the range into position, it will stop when the rear of the control panel or side panels contact the notches toward the front of the countertop.
SIDE
VIEW
All specications subject to change without notice.
DOWNDRAFT ERV30[15] WITH SLIDE-IN, SELF-RIMMING INSTALLATION, 3” SIDE PANELS INSTALLED
DOWNDRAFT ERV30[15] WITH SLIDE-IN, SELF-RIMMING INSTALLATION, 3” SIDE PANELS REMOVED
VIEW
TOP
Phone: (800) 793-0093www.dacor.com
SIDE
VIEW
Loading...