ER36D, ER48D
48” (1219mm)
**
**
**
** Optional
1 1/16” (27mm) to cooking
surface (top of grates) from
top of trim
Finished Side
Panel
Revised
03/10/09
Epicure® Ranges
All tolerances: +/- 1/16” (+/- 1.6mm) unless otherwise stated
Range Model Circuit Required
ER36D
ER48D
* 4-wire, two 120 Vac hot (L1 and L2), one neutral, one ground
Gas Type Manifold Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
PLANNING
1/2
ELECTRIC CIRCUIT REQUIREMENTS
240 Vac, 4-wire* 60 Hz,
30 Amp. (Min.) 40 Amp.
(Recommended)
240 Vac, 4-wire* 60 Hz,
50 Amp.
GAS SUPPLY PRESSURE REQUIREMENTS*
GUIDE
Total Connected Load
6.5 kW (28 Amp.)
10.0 kW (42 Amp.)
Minimum Gas
Supply Pressure
* Maximum gas supply pressure 1/2 p.s.i. for all models
Width: ER36D - 35 7/8” (911mm)
ER48D - 47 7/8” (1216mm)
GAS - ELECTRICAL ACCESS DIMENSIONS
Model A B C
ER36D
ER48D
5 5/8”
(142.9mm)
3 13/16”
(96.8mm)
18 3/8”
(466.7mm)
18 11/16”
(474.7mm)
10 3/4”
(273.0mm)
9 3/8”
(238.1mm)
D E*
13 11/16”
(347.7mm)
13 3/4”
(349.3mm)
7/8”
(22.2mm)
1 1/8”
(28.6mm)
Gas Regulator Access,
Cover Removed
Range Electrical Access,
Cover Removed
Inlet
Back of Range
* The diameter on models equipped for use in Canada is ¼”
(6.4mm) larger than those stated. Canadian units come from
the factory pre-wired with an appliance cord. When installing an
appliance cord on models that are not pre-wired, the hole size must
be increased to 1 1/8” (1 3/8” for model ER48D) by removing the
conduit bracket inside the range electrical access box.
E Electrical Connection
Hole in Bottom
NOTES:
WARNING
1. When installing a backguard, always install it
before sliding the range into place.
Observe all governing codes and ordinances during ◊
planning and installation. Contact your local building
department for further information.
This appliance must be installed in accordance with the ◊
accompanying installation instructions.
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
5.15
ER36D, ER48D
3
2, 5
F
G
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
4
Consult local code for exact location requirements.
5
Not applicable for cabinets more than a horizontal
distance of 10” (254mm) from the edge of the range.
1
Vertical to combustibles directly above cooking surface;
if installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2
Measured from range top panel.
Non-combustible
surface along
back wall
recommended
30” (762mm)
Min.
1
36 1/2”
(927mm)
Max.
13” (330mm)
Max.
5
Suggested
location of
utilities
4
G
10" (254 mm) Min.
to combustible side
walls above the range
(both sides)
non-combustible
Minumum Countertop Height:
30 1/4” (768 mm)
Maximum Countertop Height:
36 1/2” (927 mm)
rear wall recommended
Backsplash
3/8" (10 mm)
Min. flat countertop
overhang
H
2 13/16"
(71.4 mm)
3
Stiffener
Cabinet face**
Countertop*
* IMPORTANT: See “CUTOUT WITH OPTIONAL ERV RAISED VENT”
for countertop cutout dimensions.
** IMPORTANT: Cabinet face must not stick out further than
back of control panel.
Back of
control
panel
ERV36-ER or
ERV48-ER
raised vent
ER36D or ER48D Range
3/8” Min. (10 mm)
space behind
raised vent
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Countertop height:
30 1/4" (768 mm) Min.
36 1/2” (927 mm) Max.
Revised
03/10/09
Epicure® Ranges
Tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated
Gas and Electrical Service
For replacement purposes, the location of the existing utilities ◊
may be utilized provided they do not interfere with the sides or
rear of the range. Check local building codes for permissible
locations.
An external manual shut-off valve must be installed between ◊
the gas inlet and the range, for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. ◊
Access to the remote circuit breaker panel/fuse box, when the ◊
range is in place.
The gas supply piping and shut-off valve, and the electrical ◊
junction box/receptacle must be located so they do not
interfere with the range when it is installed.
The junction box and gas shut off valve must be located so ◊
that the range can be pulled out for service while the appliance
remains connected.
PLANNING
2/2
GUIDE
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
CUTOUT WITH OPTIONAL ERV RAISED VENT
(TOP VIEW)
APPROVED RAISED VENT MODELS
Raised Vent Model
ERV36-ER ER36D
ERV48-ER ER48D
For use with
Range Model
CUT-OUT DIMENSIONS
Range Model “F” “G” “H”
ER36D
ER48D
42” (1067mm)*
36” (914mm)**
54” (1372mm)*
48” (1219mm)**
36 1/16”
(916mm)**
48 1/16”
(1221mm)**
* Recommended
**Minimum
RAISED VENT INSTALLATION SIDE VIEW
Specifications are subject to change without notice.
See installation instructions for additional details.
33 1/2”
(848mm)
43 1/2”
(1102mm)
5.16