Dacor ER30GSCHNG Planning Guides PDF [0.5 MB]

ER30G
1 1/16” (27mm)
1 9/16” (40mm)
Front of open door Front of handle
Front edge of bullnose Front panel Rear of front panel
Backguard thickness
26 1/16” (662mm)
27” (686mm)
28 1/2” (724mm)
23 15/16” (608mm)
3” (76mm) Backguard**
6” (152mm) Backguard*
** Optional
* Standard
35”
(889mm)
to
37 1/8”
(943mm)
9” (229mm) Backguard**
45 1/2” (1156mm)
Revised 10/21/08
30” Wide, Epicure™
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
PLANNING
1/2
GUIDE
Electrical
Range Model
ER30G 120 Vac,
ELECTRICAL REQUIREMENTS
Required
60 Hz, 15 Amp
Circuit
ER30G
OVERALL DEPTH DIMENSIONS
SIDE VIEW
Total
Connected
Load
0.5 kW
(4.0 Amp)
Product Width: 29 7/8” (759mm)
WARNING
Observe all governing codes and ordinances during ◊ planning and installation. Contact your local building department for further information.
This appliance must be installed in accordance with the ◊ accompanying installation instructions.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
Specifications are subject to change without notice. See installation instructions for additional details.
5.5
ER30G
**
** Cabinet depth is at discretion of customer but cabinet face MUST NOT protrude further than rear of front panel, see product dimesions *** Consult local code for exact location requirements.
* Vertical to combustible surface
B
A
Non-Combustible surface along back wall recommended
Suggested location of utilities***
30” (762mm)
min.*
12 1/2”
(31.8 cm)
to
14 5/8”
(37.1 cm)
2 5/8”
(66.7 cm)
Revised 10/08/08
30” Wide, Epicure™
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.
Model Number “A” “B”
ER30G 30 1/16” (764mm)
1. Utilities may be located in the lower left
2. Contact your local building department
PLANNING
2/2
NOTES:
corner of the adjacent right cabinet. (Recommended)
to verify compliance with local code interpretation.
GUIDE
30” (762mm) Minimum
36” (914mm) Recommended
CUTOUT DIMENSIONS
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Natural 5” 6” 1/2 p.s.i.
LP 10” 11” 1/2 p.s.i.
IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
door (remove the door according to the installation instructions to view it).
The gas connection is located on the back of the unit as shown.
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
BACK OF RANGE
Specifications are subject to change without notice. See installation instructions for additional details.