Dacor ER30GISCHNG Planning Guides PDF [0.75 MB]

Page 1
ER30G, ER30GI
1 1/8” (29mm)
1 9/16” (40mm)
2” (51mm)
3” (76mm)
Front of open door Front of handle
Front edge of bullnose Front panel Rear of front panel
Backguard thickness
26 1/8” (664mm)
27 1/16” (687mm)
28 9/16” (725mm)
24” (610mm)
3” (76mm) Backguard***
ER30G:
Full stainless
steel side panels
ER30GI: Partial stainless steel side panel
Grates extend
1” above trim
6” (152mm) Backguard*
1 3/4” (44mm) Backguard**
***
**
*
Optional on both models, NOT compatible with self-rimming installations
Standard on model ER30G Optional on model ER30GI, NOT compatible with self-rimming installations
Standard on model ER30GI Optional on model ER30G
Product width: 29 7/8” (759mm)
ER30G is designed for freestanding install­ations. ER30GI is designed for installation in a recessed cabinet or island. ER30G is
NOT equipped for self-rimming installation.
NOTE: Neither model is
compatible with a raised vent.
35”
(889mm)
to
37 1/8”
(943mm)
9” (229mm) Backguard***
45 9/16” (1157mm)
Document # PG05-001 Revised 05/25/10 Page 1/3
30” Wide, Epicure
All Gas Range
®
PLANNING
GUIDE
Electrical Circuit
Required
120 Vac, 60 Hz, 15 Amps.,
dedicated, grounded
ELECTRICAL REQUIREMENTS
All tolerances ±1/16” (±1.6mm) unless otherwise noted.
Total Connected
Load
4.0 Amps. @ 120 Vac, 60 Hz
WARNING
Specications subject to change without notice. Install all appliances according to accompanying installation instructions.
OVERALL DEPTH DIMENSIONS - SIDE VIEW
ER30G/ER30GI
www.Dacor.com Phone: (800) 793-0093
5.1
Page 2
Note 2
2
Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See product dimesions.
3
Consult local code for exact location requirements.
4
Not applicable for cabinets more than a horizontal distance of 10” (254mm) from the edge of the range.
1
Vertical to combustible surface from range grate level
B
A
Non-combustible surface along back wall recommended
10” (254mm Min. to combustible side walls above the range (both sides)
Top of finished counter
Suggested location of utilities
3
30” (762mm)
Min.
1
13” (330mm)
Max.
4
18” (457mm)
Min.
1, 4
C
non comubustible rear wall recommended
Countertop Height: Min: 34 3/4” (883mm) Max: 36 7/8” (937mm)
Countertop Thickness: Max: 1 5/8” (41mm)
countertop opening
29 1/4” (743mm)
30” (762mm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
10” Min. (254mm) to any combustibles above counter both sides
Countertop overhang
2 1/8” (54mm) Max.
24”
(610mm)
rear wall or countertop edge
Countertop Height: Min: 34 3/4” (883mm) Max: 36 7/8” (937mm)
Countertop Thickness: Max: 1 5/8” (41mm)
countertop opening
29 1/4” (743mm)
30” (762mm)
cabinet opening
below countertop
below countertop
Cabinet face
Notch countertop
overhang to width of
cabinets
3/4” Min. (19mm)
Countertop overhang
10” Min. (254mm) to any combustibles above counter both sides
Countertop overhang
2 1/8” (54mm) Max.
24 1/8”
(613mm)
Document # PG05-001 Revised 05/25/10 Page 2/3
ER30G, ER30GI
30” Wide, Epicure
All Gas Range
®
PLANNING
GUIDE
All tolerances +1/16” -0 (+1.6mm, 0) unless otherwise noted.
A* B
30 1/16” (764mm)
30” (762mm) Minimum
36” (914mm) Recommended
37 1/8” (943mm)
Maximum
* See the cutout dimensions below for self-rimming installations
NOTE: Self-rimming kit is included with model ER30GI.
The self-rimming kit allows the trim to overlap the counter top on the sides and back.
C
SLIDE-IN CUTOUT DIMENSIONS
Specications subject to change without notice. Install all appliances according to accompanying installation instructions.
SELF-RIMMING CUTOUT DIMENSIONS -
CABINET DEPTH EXACTLY 24 INCHES
(ER30GI ONLY)
SELF-RIMMING CUTOUT DIMENSIONS -
CABINET DEPTH GREATER THAN 24 INCHES
(ER30GI ONLY)
www.Dacor.com Phone: (800) 793-0093
5.2
Page 3
12 1/2”
(318 mm)
to
14 5/8”
(371 mm)
2 5/8”
(67 mm)
C
L
C
L
10” (254mm)
10” (254mm)
12” (305mm)
2 1/2”
(64mm)
3 1/2”
(89mm)
1” (25mm)
Document # PG05-001 Revised 05/25/10 Page 3/3
ER30G, ER30GI
30” Wide, Epicure
All Gas Range
®
PLANNING
GUIDE
BACK OF RANGE UTILITY CLEARANCE BEHIND RANGE
GAS SUPPLY PRESSURE REQUIREMENTS
Gas
Type
Natural 5” 6” 1/2 p.s.i.
LP 10” 11” 1/2 p.s.i.
IMPORTANT: The information above is for reference only. If the above data does not agree with the product data label, use the data on the product data label on top of the kick plate below the door (remove the door according to the installation instructions to view it).
The gas connection is located on the back of the unit as shown. Use a 1/2" male NPT to connect to the regulator.
Manifold
Pressure* (WC)
Min. Gas Supply
Pressure (WC)
Max. Input
Pressure
Specications subject to change without notice. Install all appliances according to accompanying installation instructions.
www.Dacor.com Phone: (800) 793-0093
5.3
Loading...