Dacor ER30DSR User Manual 3

28 5/8” (727mm)
37 7/8”
(962mm)
to
35 3/4”
(908mm)
46 1/16” (1170mm)
27 1/8” (689mm) 26 1/8” (663mm)
24 1/16” (611mm)
23” (584mm)
Rear of Front Panel to Back of Chassis
1 1/16” (27mm)
26 3/8” (670mm)
27 5/16” (694mm)
28 13/16” (732mm)
24 1/4” (616mm)
3” (76mm) Backguard*
6” (152mm) Backguard**
** Optional
* Standard
37 7/8”
(962mm)
to
35 3/4”
(908mm)
46 1/4” (1175mm)
9” (229mm) Backguard**
37 7/8”
(962mm)
to
35 3/4”
(908mm)
Rear of Front Panel to Back of Chassis
28 1/8” (714mm)
45 9/16” (1157mm)
26 5/8” (676mm) 25 5/8” (651mm)
23 9/16” (598mm)
23” (584mm)
103107
Finished Side
Panel
Epicure™ Ranges
All tolerances: +1/16”, -0 (+1.6mm, -0)
1/3
PLANNING
GUIDE
MoDEL ER30D
MoDEL ER30
SIDE DIMENSIoNS
SELf RIMMING wIth ERv
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
MoDEL ER30D
SIDE DIMENSIoNS
wIth StANDARD tRIM
ELECTRIC CIRCUIT REQUIREMENTS
Range Model Circuit Required
ER30D/ER30DSR
240VAC,
60Hz, 30A
Total Connected
Load
5.6kW (23A)
The ratings above are for reference only -
refer to the range rating label
Specifications are subject to change without notice. See installation instructions for additional details.
5.7
24” Typ.
(610mm)
25” Typ.
(635mm)
F
G
Non-Combustible Rear Wall
Combustible Side Wall Above Range
Countertop
Opening
29 1/4” (743mm)
30 1/16” (764mm)
Cabinet
Opening
23 9/16”
(598mm)
7/16”
(11mm)
10” Min.
(254mm)
Both Sides
1”
(25mm)
Rear Wall
Countertop
Opening
29 1/4” (743mm)
ERV Opening
27 7/8” (708mm)
Minimum Cabinet depth: 27 1/8” (688mm) Minumum Countertop depth: 28 1/8” (714mm)
30 1/16” (764mm)
Cabinet
Opening
24 1/16”
(611mm)
2 13/16” (71mm)
1”
(25mm)
1/4” Min.
(6mm)
Combustible Side Wall Above Range
10” Min.
(254mm)
Both Sides
103107
Epicure™ Ranges
All tolerances: +1/16”, -0 (+1.6mm, -0)
CAbINEt CUt-oUt DIMENSIoNS
PLANNING
2/3
CUT-OUT DIMENSIONS
“F” “G”
36” (914mm)*
30” (762mm)**
30
* Recommended
** Minimum
Gas and Electrical Service
The shaded area shown denotes the location of the gas ◊ inlet and the electrical junction box/receptacle. This is the recommended location. For replacement purposes, the location of the existing utilities may be utilized provided they do not interfere with the sides or rear of the range. Check local building codes for permissible gas valve locations.
An external manual shut-off valve must be installed between ◊ the gas inlet and the range, for the purpose of turning on or shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed. ◊
Access to the remote circuit breaker panel/fuse box, when ◊ the range is in place.
The gas supply piping and shut-off valve, and the electrical ◊ junction box/receptacle must be located so they do not interfere with the range when it is installed.
The junction box and gas shut off valve must be located ◊ so that the range can be pulled out for service while the appliance remains connected.
GUIDE
1
/16” (916mm)*
Web: http://www.Dacor.com Corporate Phone: 800-793-0093
CAbINEt CUt-oUt DIMENSIoNS
SELf RIMMING INStALLAtIoN
CAbINEt CUt-oUt DIMENSIoNS
SELf RIMMING INStALLAtIoN
wIth ERv RAISED vENt
Specifications are subject to change without notice. See installation instructions for additional details.
5.8