Dacor DYWS4 Planning Guide

Document #PG15-001
19 9/16”
(49.7 cm)
24 5/8”
(62.5 cm)
25 5/8”
(65.1 cm)
Leveling feet
Adjustable 1” to 4”
(2.5 cm to 10.2 cm)
16”
(40.6 cm)
3 13/16” (2.1 cm)
3 13/16” (2.1 cm)
9 5/16”
(23.7 cm)
Revised 01/11/17—Page 1 of 3
Discovery® Wine Dispensing System
Technical Specifications/Dimensions
Bottle capacity 4
Power-supply input req’s. 120 Vac, 60 Hz, 2 Amps
Circuit requirement
Power-cord length 74” (188 cm); u
Gas-tubing length 117” (297 cm); usable length: 72 in. (183 cm)
Appliance weight (empty) 80 lbs. (32 kg)
Operating (room) temp min. 50°F (10°C); max. 80°F (26.7°C)
120 Vac, 60 Hz, 10 Amp. 3-wire (hot–L1, neutral (N1), ground), dedicated circuit w/grounded 3-prong electrical outlet
sable length: 48 in. (122 cm)
PLANNING
GUIDE
All cabinet tolerances: +1/16” (+1.6 mm) -0,
• Observe all governing regulation during planning and installation. Contact your local building department for details.
• This appliance must be installed according to the provided instructions.
unless otherwise stated.
WARNING
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
15.4
Document #PG15-001
1” (2.5 cm)
min.
Revised 01/11/17—Page 2 of 3
Discovery® Wine Dispensing System
All cabinet tolerances: +1/16” (+1.6 mm) -0,
PLANNING
GUIDE
unless otherwise stated.
ALLOW FOR PROPER AIR CIRCULATION
NOTES
• The wine-dispensing system must be installed at a safe distance from heat sources (e.g., heaters, ovens, direct sunlight).
• This appliance is designed for indoor use but may be installed outdoors in a covered, dry location and operated within the required ambient (room) temperature (see Pg. 1).
• All specified maximum/minimum dimensions and clearances must be met or exceeded.
• Due to the possibility of spillage, DO NOT install this appliance above/below another appliance.
• To prevent tipping, do not install this appliance in an unrestrained, free-standing cabinet.
• Install the dispenser only on a flat, level surface that can support its weight; the dispenser must be upright to operate.
• The dispenser must be installed where it is free of potential safety hazards that might impede installation, functionality, or air circulation around the unit. The location must be clean, dry, and free of debris.
• The dispenser’s 3-prong electrical outlet must be situated so the dispenser can be easily unplugged as needed.
• A minimum space of 13” H x 9” W x 4” D (33 cm H x 23 cm W x 10 cm D) must be provided in a nearby cabinet (within 6 ft. of the dispenser) to accommodate the dispenser’s argon-gas cylinder, regulator, and gas line (with fittings).
• Dacor recommends installating an external UPS with backup battery so the dispenser does not need to be reset after a power outage.
• Do not plug the dispenser into an electrical outlet that can be turned off via switch or pull chain.
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com