Dacor DYOV User Manual

Document # PG01-011
C
J
B
H
G
F
A
Control panel
side view
Control panel
front
Top of
chassis
Top of
chassis
Utility
cutout
Conduit:
60” (152 cm)
long
K
E
D
3 1/2”
(8.9 cm)
3 3/16”
(8.1 cm)
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
21 7/8”
(55.6) cm
DYO, DYOV
Revised 09/23/13 Page 1/2
Discovery™ iQ 30” Wide
Single Wall Ovens
WARNING
• Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
• This appliance must be installed in accordance with the accompanying installation instructions.
Dedicated Circuit
Required
240 Vac, 4-wire*,
60Hz, 30 Amp.
* Two 120 Vac hot (L1 and L2), one neutral, one ground.
** This specification is for reference only. See the product data label for exact specifications.
Total
Connected Load**
240 Vac 60 Hz,
22.5 Amp. 5.4 kW
PLANNING
GUIDE
Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
HANDLE DIMENSIONS - SIDE VIEW
28 3/4”
(73.0 cm)
A B C D E F G H J K
29 7/8”
All specications subject to change without notice.
(75.9 cm)
28 1/4”
(71.8 cm)
27 7/16”
(69.7 cm)
PRODUCT DIMENSIONS
1 5/16”
(3.3 cm)
6 1/2”
(16.5 cm)5”(12.7 cm)
7 7/8”
(20.0 cm)
(3.5 cm)
Phone: (800) 793-0093www.dacor.com
1 3/8”
23 1/2”
(59.7 cm)
Document # PG01-011
1 1/2” (3.8 cm) thick typical counter
1” (2.5 cm) min.
to combustible floor
3/4” (1.9 cm)
support platform
Recommended
electrical
location
4” typical toe kick
36” typ.
(91.4 cm)
29” (73.4 cm)
min. to
combustibles
B
C
Alternate
electrical
locations
4“ (10.2 cm) min.
between cutout
Recommended electrical location
4 typical toe kick
B
C
B
C
3/4” (1.9 cm)
support platform
36” typical
(91.4 cm)
1 1/2” (3.8 cm) thick typical counter
3/4” (1.9 cm)
support platform
1 (2.5 cm) min.
to combustible floor
29” (73.4 cm)
min. to
combustibles
DYO, DYOV
Revised 09/23/13 Page 2/2
Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated.
A
Recommended
electrical
location
Discovery iQ 30” Wide
Single Wall Ovens
CUTOUT DIMENSIONS
SIDE-BY-SIDE UNDER-COUNTER INSTALLATION
PLANNING
GUIDE
B
29” (73.4 cm)
min. to bottom
of cabinet door
1” (2.5 cm) min.
to top of
cabinet door
4” typical toe kick
CUTOUT DIMENSIONS -
WALL INSTALLATION
NOTES:
1. 24” (61.0 cm) minimum standard interior cabinet depth. 25 3/8” (66.0 cm) for flush installation.
2. 1/8” (3 mm) minimum clearance from appliance to adjacent cabinet doors/drawers.
All specications subject to change without notice.
C
3/4” (1.9 cm)
support platform
Alternate electrical
location
31 1/4” (79.4 cm)
recommended
Installation
(A)
Standard
30”
(76.2 cm)
CUTOUT DIMENSIONS -
UNDER-COUNTER INSTALLATION
(A)
Flush
Installation
31”
(78.7 cm)
(B)
Standard
Installation
28 3/8” to 29”
(72.1 cm to
73.7 cm)
CUTOUT DIMENSIONS
(B)
Flush
Installation
30”
(76.2 cm)
(C)
Standard
Installation
27” 7/16” to
28 1/4”
(69.7 cm to
71.8 cm)
3. Two (2) Single Ovens are not approved in a stack configuration.
Phone: (800) 793-0093www.dacor.com
(C)
Flush
Installation
28 7/8”
(73.3 cm)
Loading...