DR30D
Document # PG05-006 Revised 10/01/10 Page 1/2
Distinctive™ Dual Fuel Range
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
46 3/8” (117.8 cm)
28 1/2” (72.4 cm)
26 1/2” (67.3 cm)
24 3/8” (61.9 cm)
1 1/8” (2.9 cm)
9” (22.9 cm)
Backguard**
1 1/8” (2.9 mm) to cooking
surface (top of grates) from
top of trim
Width at front panel:
29 7/8” (75.9 cm)
Finished side panel
Front of open door
Front of knobs
Front panel
Rear of front panel/oven door
6” (15.2 cm)
3” (7.6 cm)
Backguard*
Backguard**
*
Standard
** Optional
35 3/4”
(90.8 cm)
to
37 7/8”
(96.2 cm)
PLANNING
GUIDE
WARNING
• Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
• This appliance must be installed in accordance with
the accompanying installation instructions.
Gas
inlet
Range electrical access,
cover removed
B
D
PRODUCT DIMENSIONS
NOTE: This range is NOT designed for self-rimming installation or
installation with a raised vent.
Optional Backguard and Island Trim Part Numbers
Description Part Number
Island trim kit (no backguard) ADTK30
6 inch trim kit ADB3006
9 inch trim kit ADB3009
Gas Supply Pressure Requirements*
Gas Type Manifold Pressure
Natural gas 5” water column 6” water column
LP 10” water column 11” water column
* Maximum input gas supply pressure for all models is 1/2 p.s.i.
The regulator inlet accommodates a 3/4” gas line. The range ships with a
1/2” to 3/4” adapter connected to the regulator.
Electrical Specifications
Circuit Required Total Connected Load
240 Vac, 60 Hz., 30 Amp.* 5.7 kW (23.8 Amp.)
* Two 120 Vac hot (L1 and L2), one neutral, one ground
The ratings above are for reference only - refer to the range's product data
label for exact specifications.
Minimum Gas Supply
Pressure
A
C
GAS AND ELECTRICAL DIMENSIONS
Gas - Electrical Access Dimensions
A B C
4 3/4”
(12.1 cm)
Ranges equipped for installation in Canada:
■ Ranges equipped for use in Canada come pre-wired with a 4-wire,
66 inch (168 cm) long, appliance cord and NEMA 14-50P plug.
■ Do not modify the factory wiring. The plug is designed to plug directly
into a NEMA 14-50R electrical receptacle installed by a licensed
electrician.
All other models:
The conduit or appliance cord installed needs to be long enough to allow
the range to be pulled out from the wall for service, while remaining
connected. See next page for further details.
The wiring to the range must:
◊ Include a strain relief.
◊ Be terminated by tinned leads, closed loop terminals or open ended
spade lugs with upturned ends.
Where local code permits, a 3 or 4 wire appliance cord may be used. It
must:
◊ Be UL listed type SRD or SRDT.
◊ Be equipped with a NEMA 14-50P 4-wire plug
or, where local code permits, a NEMA 10-50P
3-wire plug.
22 1/8”
(56.2 cm)
7/8” (2.2 cm) dia. electrical
7/8" to 1 1/8" dia. access hole
connection hole in bottom*
8 3/4”
(22.2 cm)
D
13 3/4”
(34.9 cm)
Specications subject to change without notice. Phone: (800) 793-0093www.dacor.com
5.14
DR30D
Document # PG-006 Revised 10/01/11 Page 2/2
Distinctive Range
Cabinet Layout
■ Carefully check the location where the range is to be installed. For
best performance, the range should be placed away from drafts that
may be caused by doors, windows and heating and air conditioning
outlets.
■ To reduce the risk of personal injury and to reduce accumulated
smoke in the room, Dacor strongly recommends installing a range
hood. A range hood should project horizontally a minimum of five (5)
inches beyond the face of the cabinets.
■ All maximum and minimum dimensions and clearances shown in the
diagram below must be maintained for safe operation.
■ The range may be installed flush to the rear wall. A non-combustible
rear wall is not mandatory, but Dacor highly recommends installing
a non-combustible material from the countertop level up to the vent
hood or installation of a backguard.
■ Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
Cabinet tolerances: -1/16”, (+1.6mm) -0
E
PLANNING
GUIDE
Gas and Electrical Service
■ The shaded area shown below denotes the location of the gas inlet
and the electrical junction box/receptacle. This is the recommended
location. For replacement purposes, the location of the existing
utilities may be utilized provided they do not interfere with the sides
or rear of the range. Check local building codes for permissible gas
valve locations.
■ An external manual shut-off valve must be installed between the gas
inlet and the range for the purpose of turning on or shutting off gas to
the appliance.
The installation must allow for the following:
■ Access to the gas shut-off valve when the unit is installed.
■ Access to the remote circuit breaker panel/fuse box when the range
is in place.
■ The gas supply piping, gas shut-off valve and the electrical junction
box or receptacle must be located so they do not interfere with the
range when it is installed.
■ The junction box and gas shut off valve must be located so that
the range can be pulled out for service while the appliance remains
connected.
13” (33.0 cm)
4
Max.
18” (45.7 cm)
37 7/8
(96.2 cm)
Max.
Min.
1, 4
Note 2
Non-combustible
surface along
back wall
recommended
30” (76.2 cm)
1
Min.
F
Suggested
location of
3
utilities
1
Vertical to combustible surface from range grate level; if
installing an overhead vent hood, also check the hood
specifications for minimum required clearances.
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
4
Not applicable for cabinets more than a horizontal
distance of 10” (25.4 cm) from the edge of the range.
REQUIRED CABINET DIMENSIONS
10” (25.4 cm) Min.
to combustible side
walls above the range
(both sides)
Cutout Dimensions
E F
36” (91.4 cm)*
30” (76.2 cm)**
* Recommended
** Minimum
1
30
/16” (916mm)
Specications subject to change without notice. Phone: (800) 793-0093www.dacor.com
5.15