Cybex international 8800, 8810, 8830, 8840 Medical Owner’s Manual

Product Number 8800/8810/8830/8840
Medical Owner’s Manual
Strength Systems
Part Number 8800-888-4 A
www.cybexinternational.com
Product Number 8800/8810/8830/8840
Medical Owner’s Manual
Strength Systems
Part Number 8800-888-4 A
Cybex® and the Cybex logo are registered trademarks of Cybex International, Inc.
© Copyright 2010, Cybex International, Inc. All rights reserved. Printed in the United States of America.
10 Trotter Drive Medway, MA 02053 • 508-533-4300 • FAX 508-533-5183 www.cybexinternational.com • techhelp@cybexintl.com • 8800-888-4 A • October 2010
Table of Contents
1 Safety
Safety ......................... 1-1
Safety Guidelines and Practices . . . . 1-3
Warning/Caution Decals .......... 1-4
Regular Maintenance Activities ..... 1-6
Using Proper Form . . . . . . . . . . . . . . 1-6
2 Exercises
Intended Use . . . . . . . . . . . . . . . . . . 2-1
Instructions . . . . . . . . . . . . . . . . . . 2-1
3 Customer Service
Contacting Service .............. 3-1
4 Maintenance
Daily Procedures ................ 4-1
Weekly Procedures .............. 4-2
Yearly Procedures ............... 4-3
Environment. . . . . . . . . . . . . . . . . . . 4-4
Storage . . . . . . . . . . . . . . . . . . . . . . 4-4
Page i
Cybex Product Number 8800/8810/8830/8840 Medical Owner’s Manual
1 - Safety
Safety
This product complies with the Eurpoean Medical Directive 93/42/EEC. Read the Owner’s manual carefully before using or servicing the equipment. It is the responsibility of the facility owner and/or owner of the equipment to instruct users on proper operation of
the equipment and review all labels.
WARNING: Serious injury could occur if these safety precautions are not observed:
User Safety Precautions
Follow advice of medical staff prior to beginning an exercise program.
If a user has special needs (such as medical rehabilitation or disability) it is essential that the owner (person
with legal responsiblity) conducts a specifi c risk assessment to determine safe use and if necessary trained staff are available to supervise the activity.
Injuries to health may result from incorrect or excessive training.
Read and understand warning labels and user manual prior to exercising. Obtain instruction prior to use. Keep body and clothing free from and clear of all moving parts. Inspect machine prior to use. DO NOT use if it appears damaged or inoperable.
DO NOT
attempt to fi x a broken or jammed machine. Notify fl oor staff.
Use this machine only for the intended use.
DO NOT modify the machine.
Be sure that the weight pin is completely inserted. Use only the pin provided by the manufacturer. If unsure,
seek assistance. Never pin the weights in an elevated position.
DO NOT use the machine if found in this condition. Seek
assistance from fl oor staff. The intended use is not for children. Keep all children (12 and under) away. Teenagers (13 and over) must
be supervised.
DO NOT use if guards are missing or damaged.
DO NOT
use dumbbells or other incremental weights, except those provided by the manufacturer.
Inspect all cables and belts and connections prior to use. DO NOT use if any components are worn, frayed
or damaged.
DO NOT
remove any labeling from equipment. Replace any damaged labels
Stop exercising if you feel faint, dizzy or experience pain at any time while exercising and consult your
physician.
Safety
Page 1-1
Cybex Product Number 8800/8810/8830/8840 Medical Owner’s Manual
Facility Safety Precautions
Read the Owner’s Manual carefully before assembling, servicing or using the equipment.
Securely anchor each machine to the fl oor using the anchor holes provided in each
machine.
NOTE: Cybex is not responsible for the actual anchoring of equipment. Consult with a professional
contractor.
NOTE: Use fasteners having a minimum of 2,220 newtons tensile capacity NOTE: If legs/frame does not contact surface, DO NOT pull down with anchors. Shim any leg or
frame not in contact with surface using fl at washers.
Make sure that each machine is set up and operated on a solid level surface.
Do not install
equipment on an uneven surface.
Make sure that all users are properly trained on how to use the equipment and proper supervision based on
individual indication is provided.
Make sure there is enough room for safe access and operation of the equipment.
NOTE: At least one meter
around machine when in exercise position.
Perform mandatory safety inspections. Perform regular maintenance checks on the equipment. Also pay
close attention to all areas most susceptible to wear, including (but not limited to) cables, pulleys, belts and grips.
Immediately replace worn or damaged components. If unable to immediately replace worn or
damaged components, then remove from service until the repair is made.
Use only Cybex supplied components to maintain/repair the equipment. Keep a repair log of all maintenance activities. Inspect all cables and belts and connections prior to use. DO NOT use if any components are worn, frayed
or damaged.
NOTE: It is the sole responsibility of the user/owner or facility operator to ensure that regular
maintenance is performed.
NOTE: These machines do not have range limiting devices. Check range of movement of patient carefully before
using equipment. Select resistance according to the individual indication. If you are unsure then start at lowest level. Perform exercises using smooth controlled movements.
Safety Page 1-2