CyberResearch GDR 15L, GDR 15L-TR User Manual

Displays
GDR 15L Series
GDR 15L: 15.1
GDR 15L-TR: GDR 15L with Resistive Touchscreen
USER’S MANUAL
No part of this manual may be reproduced without permission
CyberResearch®, Inc.
www.cyberresearch.com
25 Business Park Dr., Branford, CT 06405 USA
Rugged Desktop LCD Monitor
VER. 1.1 • MAR 2005
®
203-483-8815 (9am to 5pm EST) FAX: 203-483-9024
CyberResearch® Displays GDR 15L Series
©Copyright 2005
All Rights Reserved.
March 29, 2005
The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of CyberResearch, Inc.
In no event will CyberResearch, Inc. be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of or inability to use the product or documentation, even if advised of the possibility of such damages.
This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of CyberResearch, Inc.
Trademarks
“CyberResearch,” and “GDR 15L Series,” are trademarks of CyberResearch, Inc. Other product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
• NOTICE •
CyberResearch, Inc. does not authorize any CyberResearch product for use in life support systems, medical equipment, and/or medical devices without the written approval of the President of CyberResearch, Inc. Life support devices and systems are devices or systems which are intended for surgical implantation into the body, or to support or sustain life and whose failure to perform can be reasonably expected to result in injury. Other medical equipment includes devices used for monitoring, data acquisition, modification, or notification purposes in relation to life support, life sustaining, or vital statistic recording. CyberResearch products are not designed with the components required, are not subject to the testing required, and are not submitted to the certification required to ensure a level of reliability appropriate for the treatment and diagnosis of humans.
CyberResearch, Inc. iii 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
GDR 15L Series CyberResearch® Displays
Intentionally Blank
iv GDR 15L Series
Table Of Contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . .1
2. Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . .2
3. Connecting to a Computer . . . . . . . . . . . . . .3
4. Image Control and Adjustment . . . . . . . . . .4
5. Specifications . . . . . . . . . . . . . . . . . . . . . . .6
6. Cleaning and Maintenance . . . . . . . . . . . . .9
7. Service and Support . . . . . . . . . . . . . . . . . .9
CyberResearch® Displays GDR 15L Series
CyberResearch, Inc. vi
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
GDR 15L Series CyberResearch® Displays
vii ©Copyright 2005 CyberResearch, Inc.
1. Introduction
Thank you for purchasing the GDR 15L rugged TFT display. The GDR 15L range of products have been designed to provide the highest
possible image quality, in a rugged housing that has specifically been manufactured to operate in environments that would normally be considered too harsh for normal computer equipment .
What makes the GDR 15L different?
The GDR 15L is a high quality, Ultra-Bright TFT LCD display with a resolution
of 1024x768. Sleek yet solid, our GDR Series displays feature a two-piece cast aluminum shell with low-profile rubber buttons, designed to withstand the shock and vibration of industrial and vehicle use. The screen is crisp, flicker-free, and brilliant
This well-thought out design is NEMA 12 dust and moisture resistant, with elastomer-sealed OSD geometry controls on the front panel for convenient screen image control. Locking power and signal connectors help prevent accidental disconnection.
The GDR 15L has been rigorously tested to withstand severe shock and
continual vibration and features a panel protected by 3mm toughened glass. Each display has a guaranteed 24-hour burn prior to shipping.
CyberResearch® Displays GDR 15L Series
CyberResearch, Inc. 1
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
2. Unpacking
Along with the GDR 15L rugged TFT, each box should contain the following:
1. Universal AC/DC Power Supply
2. 2-meter VGA Connector Cable
3. 3-pin IEC Power Lead
4. 9-pin Serial Connector Cable
5. Touch Drivers CD-ROM (GDR 15L-TR touchscreen model)
6. User’s Manual * If any of these items are not included, please contact CyberResearch. In the unlikely event of product failure, please retain the original packaging so that the units may be safely returned to us for service.
Important Note: Do not use any other power supply, other than the one shipped with the unit. This may cause irreparable damage to either the panel or the electronics, and will in all cases invalidate the warranty. . It is recommended that the display be used only in conjunction with the VGA cable supplied. Deterioration in picture quality may occur if a poorly shielded cable, or a longer cable is used in its place.
GDR 15L Series CyberResearch® Displays
2 ©Copyright 2005 CyberResearch, Inc.
3. Connection to the Computer
GDR 15L Model
Using the following simple instructions, the GDR 15L will be installed and
configured within about five minutes.
On the bottom of the GDR 15L, there are two ports—a 15-pin VGA port, and
a power jack. One end of the VGA cable will already be connected to the VGA port when the unit is shipped.
3.1 Turn off the computer.
3.2 Attach the VGA cable to the video port on the PC and ensure that both
thumbscrew connections are securely fastened.
3.3 Insert the power jack on the power supply into the remaining circular
port on the monitor, and connect the power supply to an outlet using the IEC power lead.
3.4 Turn on the computer.
3.5 Turn on the display.
3.6 The display has not yet been configured, so the picture quality may
not yet be optimized.
GDR 15L-TR Touchscreen Model
In addition to the above, the touchscreen model has an extra cable terminating in a 9-pin serial connector which connects to one of the PC’s serial ports.
Power, VGA, & Touchscreen connectors on bottom of unit.
CyberResearch® Displays GDR 15L Series
CyberResearch, Inc. 3
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
4. Image Control and Adjustment
There are two important steps in order to ensure that the best possible image quality is now obtained:
4.1 Select the correct resolution and refresh rate.
The GDR 15L is intended to run at a resolution of 1024x768 pixels.
Although the unit can display in full screen mode at both 800x600 and 640x480, we strongly recommend you now set the resolution to 1024x768.
• Move the slider bar until the screen resolution is 1024x768.
• Change the refresh rate to 60 Hz
• Set the number of colors to 16 million
• Save settings before exiting.
4.2 Run the On-Screen Auto Adjust Utility using the buttons on the front of
the monitor:
• Click the “Menu” Button once. The On-Screen Menu will now pop up and
will already be highlighting the “Auto Adjust” option.
• Click “Select.”
• The display will now resize and reposition until an optimal image is
achieved.
•Wait five seconds and the On-Screen Controls will disappear.
Important Note: The panel used in the GDR 15L can operate between
a range of 60 and 75 Hz. The best frequency will depend on the driver card in the PC. If at this stage there is any “noise” on the screen, we recommend the following:
•Try increasing the refresh rate above 60Hz. Do not exceed 75 Hz.
• Fine-tune the Brightness, Contrast and Sharpness functions using
the On-Screen Control.
4.3The GDR 15L is an extremely bright display, operating at 400 nits (400
cd/m
2
). We strongly recommend that, unless the unit is used in very bright lighting conditions, the brightness be reduced to around 60 to 70% using the On-Screen Control. This helps to eliminate any residual screen noise, and also will greatly prolong the backlight life of the panel.
GDR 15L Series CyberResearch® Displays
4 ©Copyright 2005 CyberResearch, Inc.
4.4 Changing the screen resolution:
The GDR 15L can operate in full screen at either SVGA (800x600) or VGA
(640x480) .The unit cannot operate at any resolution higher than 1024x768.
In order to step down resolution, simply select the “Display” icon in the Control Panel, chose “Settings,” and move the slider bar to the desired position.
Note: When changing resolutions it may be necessary to run the On-Screen Auto Adjust utility in the new resolution in order to maximize image quality.
Whenever the display is being used at 800x600 the image quality will never be as crisp and clear as when it is operating at its preferred resolution of 1024x768. This is particularly noticeable when viewing text, especially small fonts. This is a due to the monitor “doubling” some pixels in order to fill the screen and is completely normal.
CyberResearch® Displays GDR 15L Series
CyberResearch, Inc. 5
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
GDR 15L Series CyberResearch® Displays
Display
Display Type LCD flat panel Video Input Types Standard analog VGA (15-pin) Screen Size (viewable area, diagonal) 15.1"
Display Filter Screen Size
Display Brightness 250 nits (High-Bright) Display Filter Brightness High-bright (250 to 340 nits) Resolution, max. 1024 x 768 pixels
Screen Protection
Maximum Number of Colors 16 million colors Maximum Color Depth in Bits 24-bit color Contrast Ratio 300:1
Viewing Angle
Response Rate
° Horizontal 160° ° Vertical 110° Rise 60ms Decay 50ms
Chassis
Mounting Configuration
Protection Rating
Display Filter Protection Water-Resistant (NEMA 4/12, IP65) Front Panel Material Die-cast metal Chassis Material Die-cast metal Custom Color Options Custom color available (min. qty: 100)
Mounting
VESA Mounting Hole Pattern 75x75mm VESA mounting holes
Stand Features
Touchscreen
Touchscreen Type Resistive touchscreen Touchscreen Interface RS-232 serial Light Transmittance of Touchscreen 75% Touchscreen Quantity of Wires 5-wire Touchscreen Manufacturer ELO Touchscreen Resolution 1024 x 1024 points
Indicators, Switches, & Controls
On Screen Display (OSD) Control Functions
Front Panel Controls
Power On/Off Switch 1 on/off switch
OSD Controls
Signal Connectors
Video Input Connectors HD15 (standard VGA) connector Touchscreen Connector 9-pin D-sub female
Cables
Video Cable Length (included) 6 feet Pointing Device Cable Length (included) 6ft (1.83m)
Cabling Details
06" to 15" 15" to 18"
Tempered glass Anti-reflective coating
Desktop / benchtop Swivel-arm mount Weighted desktop stand
NEMA 12 IP52 (most dust, falling water within 15 deg. of vertical)
See optional mounting stands, brackets, and swivel arms below.
Brightness Contrast Sharpness Auto adjustment
Sealed OSD controls for menu navigation (4 rubber keys)
A 6-foot male-male VGA cable is included with all models. Touchscreen models include a 6-foot DB-9 M-F touchscreen cable.
6 GDR 15L Series
CyberResearch® Displays GDR 15L Series
Power Supply
Power Supply Form Factor External (fully enclosed) Nominal Input Voltage(s) 110/220VAC Input Voltage Range(s) 100...240VAC Input Frequency 50/60Hz Power Supply Input Connector NEMA standard male PC cord socket Output Voltage(s) +12VDC
DC Input Power Info
DC Input Voltage(s) +12VDC
Cooling
Cooling Summary Convection (runs in silence)
Environmental Specifications
Operating Temperature 32°F....122°F (0°C....50°C)
Storage Temperature -13°F....140°F (-25°C....60°C)
Relative Humidity, noncondensing 5%....95%
Shock Resistance Operating
Vibration Resistance
Operating
18g half-sine for 6ms, 500 bumps per axis in each direction (total: 3000), operating.
5 to 150Hz, 1.0g peak-to-peak for 2 hours per axis, operating.
Safety & Standards Compliance
Safety/Approvals Meets EMC Directive 89/336/EEC MTBF (average) -- Display Backlight 40000 hours
Dimensions
Width 15.24" (387mm) Height 10.98" (279mm) Depth (including handles) 2.44" (62mm)
Weight
Weight 9.9lbs (4.49kg ) Display Filter Weight Under 16 lbs.
CyberResearch, Inc. 7 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
417mm
309mm
125mm
60mm
94.5mm
83.5mm
8 holes m5 helicoil *10typ
208.5mm
154.5mm
NOT TO SCALE
16
mm
16
mm
GDR 15L Series CyberResearch® Displays
8 ©Copyright 2005 CyberResearch, Inc.
6. Cleaning & Maintenance
The viewing surface should be cleaned with a suitable general purpose anti-static wipe. Never use industrial cleaners or solvents, as there are special coatings on the viewing surface that could be damaged.
7. Service and Support
If you are not completely satisfied with your GDR 15L, simply call our
toll-free hotline (1-800-341-2525) within 30 days of receiving the item. A friendly customer service technician will arrange for a full refund, replacement, exchange, or credit.
If you have any questions about your GDR 15L, call our toll-free number in
the USA (1-800-341-2525), call worldwide (203-483-8815), send a fax to (203-483-9024), or email our applications engineers at techsupport@cyber­research.com.
CyberResearch® Displays GDR 15L Series
CyberResearch, Inc. 9
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
GDR 15L Series CyberResearch® Displays
10 ©Copyright 2005 CyberResearch, Inc.
CyberResearch® Displays GDR 15L Series
Product Service
Diagnosis and Debug
CyberResearch, Inc. maintains technical support lines staffed by experienced Applications Engineers and Technicians. There is no charge to call and we will return your call promptly if it is received while our lines are busy. Most problems encountered with data acquisition products can be solved over the phone. Signal connections and programming are the two most common sources of difficulty. CyberResearch support personnel can help you solve these problems, especially if you are prepared for the call.
To ensure your call’s overall success and expediency:
1) Have the phone close to the PC so you can conveniently and quickly take action that the Applications Engineer might suggest.
2) Be prepared to open your PC, remove boards, report back-switch or jumper settings, and possibly change settings before reinstalling the modules.
3) Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board, module, or power supply.
4) Isolate problem areas that are not working as you expected.
5) Have the source code to the program you are having trouble with available so that preceding and prerequisite modes can be referenced and discussed.
6) Have the manual at hand. Also have the product’s utility disks and any other relevant disks nearby so programs and version numbers can be checked.
Preparation will facilitate the diagnosis procedure, save you time, and avoid repeated calls. Here are a few preliminary actions you can take before you call which may solve some of the more common problems:
1) Check the PC-bus power and any power supply signals.
2) Check the voltage level of the signal between SIGNAL HIGH and SIGNAL LOW, or SIGNAL+ and SIGNAL– . It CANNOT exceed the full scale range of the board.
3) Check the other boards in your PC or modules on the network for address and interrupt conflicts.
4) Refer to the example programs as a baseline for comparing code.
CyberResearch, Inc. 11 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
GDR 15L Series CyberResearch® Displays
Intentionally Blank
12 GDR 15L Series
CyberResearch® Displays GDR 15L Series
Warranty Notice
CyberResearch, Inc. warrants that this equipment as furnished will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase by the original buyer and that upon written notice of any such defect, CyberResearch, Inc. will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
This warranty shall not apply to equipment that has been previously repaired or altered outside our plant in any way which may, in the judgment of the manufacturer, affect its reliability. Nor will it apply if the equipment has been used in a manner exceeding or inconsistent with its specifications or if the serial number has been removed.
CyberResearch, Inc. does not assume any liability for consequential damages as a result from our products uses, and in any event our liability shall not exceed the original selling price of the equipment.
The equipment warranty shall constitute the sole and exclusive remedy of any Buyer of Seller equipment and the sole and exclusive liability of the Seller, its successors or assigns, in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory, including, but not limited to, any implied warranty of merchant ability or fitness and all other obligations or liabilities of seller, its successors or assigns.
The equipment must be returned postage prepaid. Package it securely and insure it. You will be charged for parts and labor if the warranty period has expired.
Returns and RMAs
If a CyberResearch product has been diagnosed as being non-functional, is visibly damaged, or must be returned for any other reason, please call for an assigned RMA number. The RMA number is a key piece of information that lets us track and process returned merchandise with the fastest possible turnaround time.
PLEASE CALL FOR AN RMA NUMBER!
Packages returned without an RMA number will be refused!
In most cases, a returned package will be refused at the receiving dock if its contents are not known. The RMA number allows us to reference the history of returned products and determine if they are meeting your application’s requirements. When you call customer service for your RMA number, you will be asked to provide information about the product you are returning, your address, and a contact person at your organization.
Please make sure that the RMA number is prominently
displayed on the outside of the box.
• Thank You •
CyberResearch, Inc. 13 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
GDR 15L Series CyberResearch® Displays
Intentionally Blank
14 GDR 15L Series
CyberResearch, Inc.
25 Business Park Drive
Branford, CT 06405 USA
P: (203) 483-8815; F: (203) 483-9024
www.cyberresearch.com
Loading...