CyberResearch ETS 2404 User Manual

Serial Communications
ETS 2604
Ethernet to 4-Port RS-232/422/485 Interface Module, 230.4 kbps Data Rate, with 4 DB-9M Connectors
USER’S MANUAL
VER. 2.0C • FEB 2008
No part of this manual may be reproduced without permission
CyberResearch®,Inc.
www.cyberresearch.com
25 Business Park Dr., Branford, CT 06405 USA
®
203-483-8815 (9am to 5pm EST) FAX: 203-483-9024
CyberResearch® Serial Communications ETS 2604
©Copyright 2008
All Rights Reserved.
February 6th 2008
The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of CyberResearch, Inc.
In no event will CyberResearch, Inc. be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of or inability to use the product or documentation, even if advised of the possibility of such damages.
This document contains proprietary information protected by copyright. All rights are reserved. No part of this manual may be reproduced by any mechanical, electronic, or other means in any form without prior written permission of CyberResearch, Inc.
Trademarks
“CyberResearch,” and “ETS 2604,” are trademarks of CyberResearch, Inc. Other product names mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies.
• NOTICE •
CyberResearch, Inc. does not authorize any CyberResearch product for use in life support systems, medical equipment, and/or medical devices without the written approval of the President of CyberResearch, Inc. Life support devices and systems are devices or systems which are intended for surgical implantation into the body, or to support or sustain life and whose failure to perform can be reasonably expected to result in injury. Other medical equipment includes devices used for monitoring, data acquisition, modification, or notification purposes in relation to life support, life sustaining, or vital statistic recording. CyberResearch products are not designed with the components required, are not subject to the testing required, and are not submitted to the certification required to ensure a level of reliability appropriate for the treatment and diagnosis of humans.
CyberResearch, Inc. iii
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
ETS 2604
Revision # Description Date of Issue
1.0h Initial Release July 2002
2.0C Revision Feb 7th 2008
iv ©Copyright 2008CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Contents
INTRODUCTION.....................................................................................................................1
OVERVIEW .........................................................................................................................................1
WHATS INCLUDED............................................................................................................................1
FACTORY DEFAULT SETTINGS ...........................................................................................................1
CARD SETUP .........................................................................................................................2
ELECTRICAL INTERFACE SELECTION..................................................................................................2
RS-485 ENABLE MODES ....................................................................................................................2
SOFTWARE INSTALLATION...................................................................................................3
WINDOWS ..........................................................................................................................................3
LOCATING THE DEVICE AND ASSIGNING AN IP ADDRESS...................................................................3
SOFTWARE DEVICE CONFIGURATION .................................................................................4
WINDOWS ..........................................................................................................................................4
WEB CONFIGURATION .......................................................................................................................4
SECURITY...........................................................................................................................................4
PORT DEFAULTS.................................................................................................................................4
CUSTOM BAUD RATES .......................................................................................................................4
RS MODES .........................................................................................................................................4
RESETTING TO FACTORY DEFAULTS ..................................................................................................4
USING THE DEVICE WITH SUPPLIED SOFTWARE .................................................................5
TACTICAL SOFTWARE ........................................................................................................................5
Configuration .................................................................................................................................5
Usage Details..................................................................................................................................5
Configuration .................................................................................................................................6
Usage Details..................................................................................................................................6
RAW DATA SOCKETS .........................................................................................................................7
Configuration .................................................................................................................................7
Usage Details..................................................................................................................................7
TECHNICAL DESCRIPTION....................................................................................................8
CONNECTOR PIN ASSIGNMENTS.........................................................................................................8
RS-422/485 (DB 9 Male)...............................................................................................................8
RS-232 (DB-9 Male)......................................................................................................................8
SPECIFICATIONS ...................................................................................................................9
ENVIRONMENTAL SPECIFICATIONS ....................................................................................................9
MANUFACTURING ..............................................................................................................................9
MEAN TIME BETWEEN FAILURES (MTBF).........................................................................................9
APPENDIX A - TROUBLESHOOTING....................................................................................10
A
PPENDIX B - HOW TO GET ASSISTANCE .........................................................................11
APPENDIX C - ELECTRICAL INTERFACE............................................................................12
RS-232 ............................................................................................................................................12
RS-422 ............................................................................................................................................12
RS-485 ............................................................................................................................................12
CyberResearch, Inc. v
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
APPENDIX D - ASYNCHRONOUS COMMUNICATIONS .........................................................13
APPENDIX E BACK PANEL...............................................................................................14
APPENDIX F - COMPLIANCE NOTICES ...............................................................................15
FEDERAL COMMUNICATIONS COMMISSION STATEMENT..................................................................15
EMC DIRECTIVE STATEMENT..........................................................................................................15
vi ©Copyright 2008CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Introduction
Overview
The CyberResearch ETS 2604 is a four-port RS-232/422/485 Ethernet based serial I/O adapter supporting data rates up to 230.4 K bps.
The RS-232 compatibility allows for connection to devices utilizing the RS-232 electrical interface, such as modems, data-entry terminals, and plotters.
RS-422 provides excellent communications for long distance device connections up to 4000ft., where noise immunity and high data integrity are essential.
RS-485 is optimized for ‘Multi-Drop’ or ‘Party-line’ operations selecting data from multiple peripherals (as many as 31 devices can be connected on an RS-485 bus).
What’s Included
The ETS 2604 is shipped with the following items. If any of these items is missing or damaged, contact CyberResearch, Inc.
ETS 2604 Ethernet Terminal Adapter
CyberResearch Software
5 volt power adapter
Ethernet cable, straight through (yellow)
Ethernet cable, cross over (blue)
Factory Default Settings
The ETS 2604 factory hardware default settings for all ports are as follows: Set up for RS422 or RS485.
T = 120 ohm termination between RX+ an d RX ­PU Pull up on RX + PU Pull up on RX -
ON
OFF
1 2 3 4 5 6 7
EN T PD PU EN
T
8
PD PU
CyberResearch, Inc. 1
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
RS-422/485
ETS 2604 CyberResearch® Serial Communications
Card Setup
Electrical Interface Selection
Each port on the ETS 2604 has the ability to be used in either RS-232 or RS-422/485. This is selectable using the software setup utility and correctly configuring DIP-switches S1-S4.
ON
ON
OFF
ON
OFF
OFF
1 2 3 4 5 6 7
EN T PD PU EN
T
8
PD PU
RS-232
1 2 3 4 5 6 7
8
RS-422/485
EN T PD PU EN
T PD PU
RS-422/485 No termination
1 2 3 4 5 6 7
EN T PD PU EN
T
8
PD PU
RS-485 Enable Modes
RS-485 is ideal for multi-drop or network environments. RS-485 requires a tri-state driver that will allow the electrical presence of the driver to be removed from the line. The driver is in a tri-state or high impedance condition when this occurs. One of the unique features of the ETS 2604 is the ability to be RS-485 compatible without the need for special software or drivers. This ability means that the user can effectively use the ETS 2604 in an RS-485 application with the standard CyberResearch Software supplied drivers.
Typically, each end of the RS-485 bus must have a line-terminating resistor (RS-422 terminates the receive end only). A 120-ohm resistor (silk-screen ‘T’) is across each RS-422/485 input in addition to a 1K-ohm pull-up (silk­screen ‘PU’) and a 1K-ohm pull down (silk-screen ‘PD’) combination that biases the receiver inputs. Only the ends of an RS-485 network should have the 120-Ohm terminating resistor. The presence of the 120-Ohm termination resistor across the input data pins (RX+/RX-) as well as the pull-up and pull-down resistors may be removed or inserted with DIP-switches S1-S4. To add the termination/bias resistors select the ‘On’ po sition, to remove it select the ‘Off’ position.
2 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Software Installation
Software installation depends on your operating system, so see the appropriate section below.
Windows
If you choose to use the ETS 2604 device as a virtual serial port, you will need to install Tactical Software's serial port redirector software Serial/IP. A 30-day trial version is included on the cd. For installation help or to download the latest version of Serial/IP, consult www.tactical-sw.com. For software configuration, see the section "Using the Device with supplied Software" below. In addition to the Serial/IP program, a utility to configure the ETS 2604 device from Windows is provided.
Locating the Device and Assigning an IP Address
Before the ETS 2604 can be used, it must be assigned an IP address valid to your network. When first powered up, the device will attempt to automatically find an IP address using DHCP. If the device has link but cannot locate a DHCP server, the link LED on the box will flash, indicating that the device does not have valid network settings. In that case, you will need to assign it a static address using the configuratio n utility prov ided . The conf igu ratio n utility is also useful for locating devices to determine the IP address. The method depends on your operating system, so see the appropriate section below.
If your device has obtained DHCP (the link light is solid) and you do not wish to put it on the local network,
Tip:
you can use your DHCP server software to find its IP using the MAC address located on the device's label. Once you have the IP, configure the device via the web (see the section Web Configuration).
CyberResearch, Inc. 3
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Software Device Configuration
Windows
Windows device configuration is performed through the “SeaLink Configuration” utility provided with the software installation. When started, the utility will display all devices on the local network (the utility cannot see devices on the other side of a router). If your device is not listed, verify that it is connected to the network (see the section Troubleshooting). To assign static IP addresses, select your device in the list, then uncheck the box that says “Enable DHCP” and change the “IP”, “Gateway”, and “Network Mask” fields to values valid on your network. Then click “Apply Changes”. The device will reboot and temporarily disappear from view, so you may need to click “Search Again” to relocate the device.
Web Configuration
Once the device has been assigned an IP address reachable from your computer, you can configure it through the onboard web server. Open a web browser such as Internet Explorer or Netscape and type “http://x.x.x.x” into the URL field, where “x.x.x.x” is the device’s IP address. The web interface provides a summary page that lists various details about the device, a port settings page that allows you to configure aspects of each individual serial port, and an administration page that lets you change the device’s network and password settings.
Security
The password you can set from the Administration page currently applies to the Web Configuration only. The web­based settings have been identified as a key area where security is important, since users do not need to install software to modify settings.
Port Defaults
The Port Settings page allows you to set defaults to which each serial port will be set when first opened. If you are using a virtual serial port protocol such as SeaLink or Tactical Software, programs may change these settings dynamically after opening the ports. If you want programs to always use the defaults you set, check the box labeled "Always use defaults". This can be useful especially when specifying a custom baud rate that is not available from your operating system (see Custom Baud Rates).
Custom Baud Rates
From the Port Settings Page, you can enter a baud rate of any value from 1 to 921600. While it may not be possible to hit the exact desired baud rate, the Uart will attempt to set it as closely as possible and will be within an acceptable 2% range. After you click Submit, the page will refresh and display the baud rate actually being used.
RS Modes
The Port Settings page allows you to specify the RS mode for a given port. This may not be the best way to configure RS modes in all situations (see the section SeaLink Protocol::Co nfiguratio n). However, if you are usin g a protocol that does not allow you to configure the RS mode, you must set the RS mode here.
In all cases, the RS mode must be set in software as well as hardware. See the section Electrical Interface Selection for details on configuring the hardware.
Resetting to Factory Defaults
If you have forgotten your password or otherwise wish to reset the device to the factory defaults, manually browse to "http://x.x.x.x/debug.htm" (where x.x.x.x is the device's IP address) and click the button marked "Reset to Factory Defaults". You will be prompted for a username and password. For the username, enter "debug". In the password field, type the MAC address of the unit, located either on the summary page or on the label on the device. The MAC address should be entered without formatting such as dashes or spaces.
4 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Using the Device with supplied Software
Accessing the serial ports through software can depend on your situation. There are two basic methods. The first method implements a virtual serial port on your computer, so you can access the remote port just like a normal onboard serial port. This is probably the best method for most situations, and allows for the most control. To use virtual serial ports in Windows, see the section Tactical Software. The second method may be useful for software developers and allows you to send/receive data through a serial port using TCP sockets. For more information, see the section Raw Data Sockets.
Tactical Software
Tactical Software (www.tactical-sw.com) implements a serial port “redirector” called Serial/IP, which allows you to create a virtual serial port on your Windows machine. All accesses to the virtual port are redirected to the remote port through the IP address you set, and you can access the virtual port with any program designed to use serial ports. For detailed instructions on using Tactical Software’s Serial/IP program, consult the help packaged with that software. What follows is an overview of getting the software to work with the ETS 2604.
Configuration
To install a SeaLink serial port, configure a new Tactical Software virtual port and point it to the device’s IP address. Note that the port number here refers to the TCP port and not the serial port on the device; however, the TCP port number to use depends on which serial port you want. The base TCP port for RFC 2217, the protocol which Tactical Software uses, is 4680. That corresponds to the first serial port on the device. Just increment the TCP port to get to the next serial port. For example, the second serial port would be at TCP port 4681, the third at 4682, and so on. You must also select “Telnet” from the list of 3 protocols for each port to work correctly. If you want the software to try and reconnect in case of accidental network loss, click the appropriate checkbox. Note that the username and password field should be left blank even if you have a password set in the Web Configuration (see the section Web Configuration::Security for more details).
You must also configure the RS mode before use if your device supports multiple electrical interfaces. Use the Web Configuration page to do this (see the section Web Configuration). Browse to the Port Settings page and select the appropriate RS mode for each port, and then click the Submit button at the bottom of the page. Be sure to configure the hardware to match the desired setting (see section Electrical Interface Selection).
Usage Details
Since Tactical Software virtualizes a serial port, any program that works with serial ports is able to access a remote port just like an onboard port. Just use the program to open the COMx number you specified when installing the port. Software developers can use the standard serial port API. See the Microsoft help on Communications Resources for more information.
CyberResearch, Inc. 5
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Configuration
Before you can access a serial port, you must “install” it to the client computer. Launch the “SeaLink Configuration” console utility by typing “/usr/sbin/sealinkcfg”. If your device is on the local network, you should see it listed. Type ‘i’ followed by the number of the hub in the list (probably “i 1”) to install it. If your device is not listed, type 'n' and follow the prompts to tell the software about your device. You must also configure the RS mode before use if your device supports multiple electrical interfaces. To do this, open the “SeaLink Configuration” utility by typing “/usr/sbin/sealinkcfg” and set each port’s mode using the ‘p’ command. Be sure to configure the hardware to match the desired setting (see section Electrical Interface Selection).
Warning:
Be careful when setting the RS mode, because the mode may conflict with the one set in the Web Configuration page. If the two conflict and the “Always use defaults” checkbox is not checked, the mode may be set incorrectly for a brief period or, worse, just set incorrectly. To be safe, leave the Web Configuration page’s RS mode set to “No Default”.
When finished configuring ports, type ‘q’ to quit. The SeaLink driver must be restarted (or started for the first time), so type either “/sbin/sealink restart” or “/sbin/sealink start”. If one gives you an error, try the other one.
Usage Details
Once a device has been installed, it can be accessed through the character devices “/dev/ttySL[0-n]”, where ‘n’ is the number of ports on your d evice – 1. For example, “echo hello > /dev/ttySL0” will send the ASCII characters “hello” to the first serial port on your device, wh ile “echo hello > /dev/ttySL2” will do the same for the th ird serial port. Additional installed por ts will be assigned to the next available range, so if you have two four-port devices installed they will be assigned to “/dev/ttySL[0-3]” and “/dev/ttySL[4 -7]” respectively.
The /dev/ttySL devices are designed to virtualize a serial port, so programs can access them just like a /dev/ttyS port using the termios functions (see the man page for termios). Note that unlike a normal serial port, SeaLink serial ports can only be opened by one program at a time. This is done to ensure that the correct client receives the correct data/signals.
6 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Raw Data Sockets
Raw Data Sockets are probably the easiest way for a software developer to control a serial port, but provide the least control from a software standpoint. You can simply open a socket to the device on the Raw Data TCP port corresponding to the serial port you want and stream data back and forth. The data will not be inspected or modified in any way. This method provides the least control because serial port functions such as baud rate and modem control signals cannot be monitored or changed programmatically. However, Raw Data is platform-independent and requires no software installation. If your purposes do not require dynamic serial port control, Raw Data may be the most efficient choice for you.
Configuration
Since Raw Data does not allow for programmatic changing of serial port controls, the serial ports must be configured before use via the onboard web server (see the section Web Configuration). From the Port Settings page, configure the ports to the desired settings and click Submit at the bottom of the page. The serial ports will automatically be set to these defaults when opened. When setting the RS mode, be sure to configure the hardware to match the desired setting (see section Electrical Interface Selection).
Usage Details
To access a serial port using Raw Data mode, open a TCP socket to the device’s IP address. The TCP port to use depends on the serial port you want. The Raw Data base is 4760, which corresponds to the first serial port on the device. Just increment the TCP port to get to the next serial port. For example, the second serial port would be at TCP port 4761, the third at 4762, and so on.
Only one client can open each serial port at a time. All further socket requests to a TCP port will be denied.
CyberResearch, Inc. 7
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Technical Description
The CyberResearch ETS 2604 provides a PCI interface adapter with 4 RS-232/422/485 asynchronous serial ports for industrial automation and control applications.
Connector Pin Assignments RS-422/485 (DB 9 Male)
Signal Name Pin # Mode
GND Ground 5 TX + Transmit Data Positive 4 Output TX- Transmit Data Negative 3 Output RTS+ Request To Send Positive 6 Output RTS- Request To Send Negative 7 Output RX+ Receive Data Positive 1 Input RX- Receive Data Negative 2 Input CTS+ Clear To Send Positive 9 Input CTS- Clear To Send Negative 8 Input
RS-232 (DB-9 Male)
Signal Name Pin # Mode GND Ground 5 TD Transmit Data 3 Output RTS Request To Send 7 Output DTR Data Terminal Ready 4 Output RD Receive Data 2 Input CTS Clear To Send 8 Input DSR Data Set Ready 6 Input DCD Data Carrier Detect 1 Input RI Ring Indicator 9 Input
Technical Note: Please terminate any control signals that are not going to be used. The most common way to do this is connect RTS to CTS and RI. Also, connect DCD to DTR and DSR. Terminating these pins, if not used, will h elp ensure you get the best performance from your adapter.
8 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Specifications
Environmental Specifications
Specification Operating Storage
Temperature
Range
Humidity Range
0º to 50º C
(32º to 122º F)
10 to 90% R.H.
Non-Condensing
Manufacturing
All Printed Circuit boards are built to U. L. 94V0 rating and are 100% electrically tested. These printed circuit
boards are solder mask over bare copper or solder mask over tin nickel.
Mean Time Between Failures (MTBF)
Greater than 150,000 hours. (Calculated)
-20º to 70º C
(-4º to 158º F)
10 to 90% R.H.
Non-Condensing
CyberResearch, Inc. 9
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Appendix A - T roubleshooting
CyberResearch Software is supplied with the ETS 2604 and will be used in the troubleshooting procedures. Using this software and following these simple steps can eliminate most common problems, without the need to call Technical Support.
1. Verify that the Power LED is lit and remains on. Caution: Use only the supplied AC/DC adapter. Any
other adapter may cause damage to the ETS 2604. If a different power solution must be made, please contact CyberResearch, Inc.
2. Verify that the Link LED remains on to determine that the 10/100 Base-T connections and the polarity are
correct. If the Link LED is lit, you have a valid Link condition.
3. Verify that the Ethernet LED remains on to determine that the 10/100 Base-T connections and the polarity
are correct. If the Ethernet LED is lit, you have a working Ethernet connection
4. Verify that the correct cable is being used (i.e. ‘Straight-thru’ for switch/hub connection and ‘cross over’
for direct connection to NIC), and that all cables are connected securely.
5. Verify that the Ethernet hub and any other network devices between the server and the ETS 2604 are
powered up and operating.
6. To isolate the unit from the network, use a ‘crossover’ Ethernet cable to connect the unit directly to the
NIC card in the server.
7. Reboot the server.
8. Ensure that server software is correctly loaded.
9. Remove and reload the server software.
10. Verify that the Ethernet hub and any other network devices between the server and the ETS 2604 are
powered up and operating.
Always use the CyberResearch diagnostic software when troubleshooting a problem. This will eliminate any software issues from the equation. If you are unable to resolve the problem, contact Technical Support.
10 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Appendix B - How To Get Assistance
Please refer to
CyberResearch, Inc. 11
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Appendix A - Troubleshooting prior to calling Technical Support.
1. Read this manual thoroughly before attempting to install the adapter in your system.
2. When calling for technical assistance, please have your user manual and current adapter settings. If
possible, please have the adapter installed in a computer ready to run diagnostics.
3. http://www.cyberresearch.com
provides the latest software updates and newest manuals for all our
products.
4. Technical support is available Monday thru Friday from 8:00 a.m. to 5:00 p.m. eastern time. Technical
support can be reached at (860) 483-8815.
12 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Appendix C - Electrical Interface
RS-232
Quite possibly the most widely used communication standard is RS-232. This implementation has been defined and revised several times and is often referred to as RS-232-C/D/E or EIA/TIA-232-C/D/E. It is defined as “Interface
between Data Terminal Equipment and Data Circuit- Terminating Equipment Employing Serial Binary Data Interchange”. The mechanical implementation of RS-232 is on a 25-pin D sub connector. The IBM PC computer
defined the RS-232 port on a 9 pin D sub connector and subsequently the EIA/TIA approved this implementation as the EIA/TIA-574 standard. This standard has defined as the “9-Position Non-Synchronous Interface between Data Terminal Equipment and Data Circuit-Terminating Equipment Employing Serial Binary Data Interchange”. Both implementations are in wide spread use and will be referred to as RS-232 in this document. RS-232 is capable of operating at data rates up to 20K bps / 50 ft. The absolute maximum data rate may vary due to line conditions and cable lengths. RS-232 often operates at 38.4K bps over very short distances. The voltage levels defined by RS-232 range from -12 to +12 volts. RS-232 is a single ended or unbalanced interface, meaning that a single electrical signal is compared to a common signal (ground) to determine binary logic states. A voltage of +12 volts (usually +3 to +10 volts) represents a binary 0 (space) and -12 volts (-3 to -10 volts) denote a binary 1 (mark). The RS-232 and the EIA/TIA-574 specification define two types of interface circuits Data Terminal Equipment (DTE) and Data
Circuit-Terminating Equipment (DCE). The CyberResearch Adapter is a DTE interface.
RS-422
The RS-422 specification defines the electrical characteristics of balanced voltage digital interface circuits. RS-422 is a differential interface that defines voltage levels and driver/receiver electrical specifications. On a differential interface, logic levels are defined by the difference in voltage between a pair of outputs or inputs. In contrast, a single ended interface, for example RS-232, defines the logic levels as the difference in voltage between a single signal and a common ground connection. Differential interfaces are typically more immune to noise or voltage spikes that may occur on the communication lines. Differential interfaces also have greater drive capabilities that allow for longer cable lengths. RS-422 is rated up to 10 Megabits per second and can have cabling 4000 feet long. RS-422 also defines driver and receiver electrical characteristics that will allow 1 driver and up to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5 volts. RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for party line or multi-drop applications. The output of the RS-422/485 driver is capable of being Active (enabled) or Tri-State (disabled). This capability allows multiple ports to be connected in a multi-drop bus and selectively polled. RS-485 allows cable lengths up to 4000 feet and data rates up to 10 Megabits per second. The signal levels for RS-485 are the same as those defined by RS-422. RS-485 has electrical characteristics that allow for 32 drivers and 32 receivers to be connected to one line. This interface is ideal for multi-drop or network environments. RS-485 tri-state driver (not dual-state) will allow the electrical presence of the driver to be removed from the line. Only one driver may be active at a time and the other driver(s) must be tri-stated. RS-485 can be cabled in two ways, two wire and four wire mode. Two-wire mode does not allow for full duplex communication, and requires that data be transferred in only one direction at a time. For half-duplex operation, the two transmit pins should be connected to the two receive pins (Tx+ to Rx+ and Tx- to Rx-). Four wire mode allows full duplex data transfers. RS-485 does not define a connector pin-out or a set of modem control signals. RS-485 does not define a physical connector.
CyberResearch, Inc. 13
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Appendix D - Asynchronous Communications
Serial data communications implies that individual bits of a character are transmitted consecutively to a receiver that assembles the bits back into a character. Data rate, error checking, handshaking, and character framing (start/stop bits) are pre-defined and must correspond at both the transmitting and receiving ends.
Asynchronous communications is the standard means of serial data communication for PC compatibles and PS/2 computers. The original PC was equipped with a communication or COM: port that was designed around an 8250 Universal Asynchronous Receiver Transmitter (UART). This device allows asynchronous serial data to be transferred through a simple and straightforward programming interface. A start bit, followed by a pre-defined number of data bits (5, 6, 7, or 8) defines character boundaries for asynchronous communications. The end of the character is defined by the transmission of a pre-defined number of stop bits (usually 1, 1.5 or 2). An extra bit used for error detection is often appended before the stop bits.
Idle state of line
1
0
5 to 8 Data Bits
Figure 1 - Asynchronous Communications Bit Diagram
This special bit is called the parity bit. Parity is a simple method of determining if a data bit has been lost or corrupted during transmission. There are several methods for implementing a parity check to guard against data corruption. Common methods are called (E)ven Parity or (O)dd Parity. Sometimes parity is not used to detect errors on the data stream. This is refereed to as (N)o parity. Because each bit in asynchronous communications is sent consecutively, it is easy to generalize asynchronous communications by stating that each character is wrapped (framed) by pre-defined bits to mark the beginning and end of the serial transmission of the character. The data rate and communication parameters for asynchronous communications have to be the same at both the transmitting and receiving ends. The communication parameters are baud rate, parity, number of data bits per character, and stop bits (i.e. 9600,N,8,1).
Odd, Even or Unused
P BIT
STOP
Remain Idle or next start bit
1
1.5 2
14 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Appendix E – Back Panel
CyberResearch, Inc. 15
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Appendix F - Compliance Notices
Federal Communications Commission Statement
FCC - This equipment has been tested and found to comply with the limits for Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in such case the user will be required to correct the interference at his own expense.
EMC Directive Statement
Products bearing the CE Label fulfill the requirements of the EMC directive (89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the European Commission.
To obey these directives, the following European standards must be met:
EN55022 Class A - “Limits and methods of measurement of radio interference characteristics of
information technology equipment”
EN55024 -'Information technology equipment Immunity characteristics Limits and methods of
measurement'
EN60950 (IEC950) - “Safety of information technology equipment, including electrical business
equipment”
Warning This is a Class A Product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Always use cabling provided with this product if possible. If no cable is provided or if an alternate cable is required, use high quality shielded cabling to maintain compliance with FCC/EMC directives.
16 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Product Service
Diagnosis and Debug
CyberResearch, Inc. maintains technical support lines staffed by experienced Applications Engineers and Technicians. There is no charge to call and we will return your call promptly if it is received while our lines are busy. Most problems encountered with data acquisition products can be solved over the phone. Signal connections and programming are the two most common sources of difficulty. CyberResearch support personnel can help you solve these problems, especially if you are prepared for the call.
To ensure your call’s overall success and expediency:
1) Have the phone close to the PC so you can conveniently and quickly take action that the Applications Engineer might suggest.
2) Be prepared to open your PC, remove boards, report back-switch or jumper settings, and possibly change settings before reinstalling the modules.
3) Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board, module, or power supply.
4) Isolate problem areas that are not working as you expected.
5) Have the source code to the program you are having trouble with available so that preceding and prerequisite modes can be referenced and discussed.
6) Have the manual at hand. Also have the product’s utility disks and any other relevant disks nearby so programs and version numbers can be checked.
Preparation will facilitate the diagnosis procedure, save you time, and avoid repeated calls. Here are a few preliminary actions you can take before you call which may solve some of the more common problems:
1) Check the PC-bus power and any power supply signals.
2) Check the voltage level of the signal between SIGNAL HIGH and SIGNAL LOW, or SIGNAL+ and SIGNAL– . It CANNOT exceed the full scale range of the board.
3) Check the other boards in your PC or modules on the network for address and interrupt conflicts.
4) Refer to the example programs as a baseline for comparing code.
CyberResearch, Inc. 17
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Intentionally Blank
18 ©Copyright 2008
CyberResearch, Inc.
CyberResearch® Serial Communications ETS 2604
Warranty Notice
CyberResearch, Inc. warrants that this equipment as furnished will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase by the original buyer and that upon written notice of any such defect, CyberResearch, Inc. will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
This warranty shall not apply to equipment that has been previously repaired or altered outside our plant in any way which may, in the judgment of the manufacturer, affect its reliability. Nor will it apply if the equipment has been used in a manner exceeding or inconsistent with its specifications or if the serial number has been removed.
CyberResearch, Inc. does not assume any liability for consequential damages as a result from our products uses, and in any event our liability shall not exceed the original selling price of the equipment.
The equipment warranty shall constitute the sole and exclusive remedy of any Buyer of Seller equipment and the sole and exclusive liability of the Seller, its successors or assigns, in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory, including, but not limited to, any implied warranty of merchant ability or fitness and all other obligations or liabilities of seller, its successors or assigns.
The equipment must be returned postage prepaid. Package it securely and insure it. You will be charged for parts and labor if the warranty period has expired.
Returns and RMAs
If a CyberResearch product has been diagnosed as being non-functional, is visibly damaged, or must be returned for any other reason, please call for an assigned RMA number. The RMA number is a key piece of information that lets us track and process returned merchandise with the fastest possible turnaround time.
PLEASE CALL FOR AN RMA NUMBER!
Packages returned without an RMA number will be refused!
In most cases, a returned package will be refused at the receiving dock if its contents are not known. The RMA number allows us to reference the history of returned products and determine if they are meeting your applic ation’s requirements. When you call customer service for your RMA number, you will be asked to provide information about the product you are returning, your addre ss, and a contact person at your organization.
Please make sure that the RMA number is prominently
displayed on the outside of the box.
• Thank You •
CyberResearch, Inc. 19
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com
ETS 2604 CyberResearch® Serial Communications
Intentionally Blank
20 ©Copyright 2008CyberResearch, Inc.
CyberResearch, Inc.
25 Business Park Drive
Branford, CT 06405 USA
P: (203) 483-8815; F: (203) 483-9024
www.cyberresearch.com
Loading...