All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 1/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Super Flower SF-750F14RG (Sample #2)
General Data
Manufacturer (OEM)Super Flower
Platform ModelLeadex III
PCB TypeSingle Sided
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 2/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Super Flower SF-750F14RG (Sample #2)
RESULTS
Temperature Range (°C /°F)30-32 / 86-89.6
ErP Lot 3/6 Ready✓
(EU) No 617/2013 Compliance✓
115V
Average Efficiency88.863%
Efficiency With 10W (≤500W) or 2% (>500W)68.905
Average Efficiency 5VSB80.323%
Standby Power Consumption (W)0.0471472
Average PF0.983
Avg Noise Output24.34 dB(A)
Efficiency Rating (ETA)ETA-A
Noise Rating (LAMBDA)LAMBDA-A
230V
Average Efficiency90.981%
Average Efficiency 5VSB79.381%
Standby Power Consumption (W)0.0790052
Average PF0.924
Avg Noise Output23.55 dB(A)
Efficiency Rating (ETA)ETA-A-
Noise Rating (LAMBDA)LAMBDA-A
TEST EQUIPMENT
Chroma 63601-5 x4
Electronic Loads
AC SourcesChroma 6530, Keysight AC6804B
Power AnalyzersN4L PPA1530 x2
Sound AnalyzerBruel & Kjaer 2270 G4
MicrophoneBruel & Kjaer Type 4955-A
Data LoggersPicoscope TC-08 x2, Labjack U3-HV x2
TachometerUNI-T UT372 x2
Digital MultimeterKeysight U1273AX, Fluke 289, Keithley 2015 - THD
UPSCyberPower OLS3000E 3kVA x2
Transformer3kVA x2
Chroma 63600-2 x2
63640-80-80 x20
63610-80-20 x2
HOLD-UP TIME & POWER OK SIGNAL (230V)
Hold-Up Time (ms)21.3
AC Loss to PWR_OK Hold Up Time (ms)18.1
PWR_OK Inactive to DC Loss Delay (ms)3.2
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 3/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE
Super Flower SF-750F14RG (Sample #2)
INFO
The PSU`s efficiency under high ambient
temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used
5VSB EFFICIENCY
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
INFO
This graph depicts the efficiency levels of the 5VSB
rail with 115V and 230V input
PAGE 4/16
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE
LEVEL CERTIFICATIONS
Anex
Super Flower SF-750F14RG (Sample #2)
5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.231
71.296%
5.125V0.324115.15V
0.090A0.461
76.325%
5.123V0.604115.15V
0.550A2.810
80.171%
5.109V3.505115.15V
1.000A5.095
80.732%
5.094V6.311115.15V
1.500A7.617
81.058%
5.077V9.397115.15V
3.000A15.048
79.229%
5.016V18.993115.14V
0.025
0.045
0.223
0.325
0.390
0.472
5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)
Test #5VSBDC/AC (Watts)EfficiencyPF/AC Volts
1
2
3
4
5
6
0.045A0.231
63.462%
5.125V0.364230.34V
0.090A0.461
71.032%
5.123V0.649230.33V
0.550A2.810
77.861%
5.108V3.609230.33V
1.000A5.094
79.222%
5.093V6.430230.33V
1.500A7.615
80.065%
5.076V9.511230.33V
3.000A15.067
80.697%
5.023V18.671230.34V
0.008
0.015
0.080
0.136
0.188
0.296
All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics
› The link to the original test results document should be provided in any case
Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient
and silent power supplies are promoted
PAGE 5/16
www.cybenetics.com - info@cybenetics.com
4004 MESA GEITONIA, LIMASSOL, CYPRUS
Loading...
+ 11 hidden pages