Cutler Hammer, Div of Eaton Corp Safety Switches General Product Line Information

8
8-2
Switching Devices Safety Switches
Product Description
Product Description
Used to open or close a circuit.
Non-fusible safety switches provide a means to manually connect or disconnect the load from the source.
Fusible safety switches provide a
means to manually open and close a circuit and overcurrent protection by means of installed fuses.
Also commonly referred to as a
disconnect switch or disconnect.
Available from 30 – 1200 amperes.
Application Description
General Duty
Plug Fuse General-Duty Safety Switch
For residential and commercial applications. Suitable for light-duty motor circuits and service entrance.
30 – 600 amperes.
Suitable for service entrance appli­cations unless otherwise noted.
Fusible and non-fusible switches are 100% load break and 100% load make rated.
The continuous load current of
fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non­fusible switches are 100% fully rated.
200 – 600 amperes features K-series design.
Horsepower rated. Fusible and non-fusible switches.
One-pole S/N through 4-wire; 120/240, and 240 Vac.
Ample wire bending space provides for easier installation.
With Class R fuses, switches may be
used on systems capable of delivering
100,000 amperes rms symmetrical.
Note: Plug fuse switches are not service
entrance rated.
Cartridge Fuse General-Duty Safety Switch
Heavy Duty
Heavy-Duty Safety Switches
For heavy commercial and industrial applications where reliable performance and service continuity are critical.
30 – 1200 amperes. 600 Vac, 600 Vdc maximum.
Horsepower rated. Fusible and non-fusible switches
are 100% load break and 100% load make rated.
The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non­fusible switches are 100% fully rated.
Suitable for service entrance applications unless otherwise noted.
Visible double break quick-make, quick-break rotary blade mechanism. Two points of contact provide a posi­tive open and close, easier operation, and also help prevent contact burning for longer contact life.
Triple padlocking capability. Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks. Cabinet door can be further pad­locked at the top and bottom.
Interlocking mechanism. Door can-
not be opened when the handle is in the ON position. Built-in defeater mechanism provides for user access when necessary.
For the toughest heavy commercial and industrial applications, refer to
Page 8-47 for catalog information on
our Mill-Duty Safety Switch.
Deionizing arc chutes. Arc chutes confine and suppress the arcs produced by opening contacts under load.
February 2007
6-Pole Switches
6-Pole Motor Circuit
A compact safety switch that’s ideal for use in heavy industry...when an “in sight” disconnecting means is required for two­speed motors that are remote from their motor control devices.
600 Vac, 250 Vdc maximum.
30 – 200 amperes. Fusible or non-fusible.
Trunk-type latches keep the cover tightly closed and a neoprene gas­ket seals out moisture and dust from the switch assembly.
Visible double break quick-make, quick-break rotary blade mechanism. Two points of contact provide a posi­tive open and close, easier operation, and also help prevent contact burning for longer contact life.
Clear line shield protection.
Built-in fuse pullers. Clearly visible handle.
Triple padlocking capability. Cabinet door can be further padlocked at the top and bottom.
Deionizing arc chutes. Arc chutes
confine and suppress the arcs produced by opening contacts under load.
For more information visit: www.eaton.com
CA08101001E
8
UL
February 2007
Double Throw Switches
Heavy-Duty Double Throw
Used to transfer service from a normal power source to an alternate source...or to switch from one load circuit to another.
30 – 800 ampere switches are horsepower rated.
600 Vac, 250 Vdc maximum.
Fusible or non-fusible. Fusible and non-fusible switches
are 100% load break and 100% load make rated.
Suitable for service entrance applications unless otherwise noted.
The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non­fusible switches are 100% fully rated.
Approved for service entrance with
neutral or ground lug kit installed. Wiring configuration from factory
allows a single load to be supplied by a normal or alternate source. Can be field modified to allow two loads to be alternately supplied by a single power source.
Non-fusible double throw switch can be used to feed a single throw fusible switch, the normal method to provide manual transfer from one power source to another in 800 ampere and larger switches.
Ample wire bending space provides
for easier installation. Visible double break quick-make,
quick-break rotary blade mechanism. Two points of contact provide a posi­tive open and close, easier operation, and also help prevent contact burning for longer contact life.
Triple padlocking capability. Person­nel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks.
Clearly visible handle. The position (ON or OFF) can be clearly seen from a distance.
Switching Devices Safety Switches
Product Description
Deionizing arc chutes. Arc chutes confine and suppress the arcs produced by opening contacts under load.
Additional locking capability. Cabinet door can be further pad­locked at the top and bottom.
Clear line shield (provided on fus­ible double throw) protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield.
Tangential knockouts on sides, top and bottom. Enables any size of conduit to be mounted close to the wall, providing for cable installation closer to the wall and a neat appearance.
listed switching neutral capability is available on 3-pole and 4-pole non-fusible double throw switches with the installation of the proper bonding kit shown on
Rotary Switches
Enclosed Rotary
Provide users with the ability to lock directly wired motor loads in the OFF posi­tion to comply with new OSHA lockout/ tagout regulations. Also for machine applications that require compact, economical disconnect switches.
Meets NEC Article 430 requirements for a separate disconnect means within sight of all motor loads.
Padlockable in the OFF position (up to three padlocks) to meet OSHA lockout requirements.
Available in 16 – 125 ampere ratings.
600 Vac, 3- and 4-pole non-fusible device.
Rated for making and breaking loads.
Accepts auxiliary contacts. Capability to signal PLC controllers.
Ground lug connection provided.
Page 8-5 .
EnviroLine
EnviroLine
Eaton offers a line of Cutler-Hammer safety switches designed for your special application and/or extreme environmental conditions.
EnviroLine Stainless Steel Switch
Primarily for use in the meat pack­ing and food processing industries or any application where water is frequently used to hose down equipment. In addition to the stain­less steel NEMA 4X enclosure, the interior mechanism, backpan, and springs are stainless steel. Ratings for these heavy-duty switches are 30 – 400 amperes, 240 – 600 Vac, available as fusible and non­fusible switches.
Window Switches — The new
enlarged window on 30 – 100 ampere
ratings allows visual blade position verification and blown fuse indica­tion without opening the door. Higher ampere ratings continue to use the Upper and Lower window design. The Upper window switch provides visual verification of ON/ OFF status (blade position), while the Lower window design shows fuse status on fuses with blown fuse indicators. Overall ratings are 30 – 800 amperes, 240 – 600 Vac, fusible and non-fusible. Available in NEMA 12/3R, 4X stainless steel enclosures.
8-3
CA08101001E For more information visit: www.eaton.com