Cutler Hammer, Div of Eaton Corp Part Numbering Designation
Specifications and Main Features
Frequently Asked Questions
User Manual
Catalog Number Selection
S 811 T 30 N 3 S
Frame Size
2
N = 65 mm
R = 110 mm
T = 200 mm
U = 200 mm
V = 290 mm
Ampere Rating
37 = 37A
66 = 66A
10 = 105A
13 = 135A
18 = 180A
24 = 240A
30 = 304A
36 = 360A
42 = 420A
50 = 500A
3
65 = 650A
72 = 720A
85 = 850A
10 = 1000A
S = Standard soft starter
(configurable for
edge or level control)
D = Inside-the-delta
L = Extended ramp start
W = Without DIM
Number of Poles
3 = Three-pole device
Options
N = No options
P = Pump control
V = 690V option (Frame
T18 through V85)
4
S = Soft Starter
811 = Non-combination
soft starter
S811 Open Soft Starters
1
Notes
1
All units require a 24 Vdc power supply found on catalog Page V6-T1-107, or equivalent.
2
3
4
T-, U- and V-Frames require lug kits found on Page V6-T1-107.
U-Frame 500A unit does not have IEC certification.
Not available in U-Frame.
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Product Selection
Standard Duty Ratings
Starting Method
Soft start300%30 sec.350°C
Full voltage500%10 sec.350°C
Wye-delta350%20 sec.350°C
80% RVAT480%20 sec.250°C
65% RVAT390%20 sec.350°C
50% RVAT300%20 sec.450°C
Motor applications and
customer needs come in
many different varieties.
With the standard and severe
duty rating tables, we have
attempted to provide
Ramp Current
% of FLA
guidelines on what the soft
starter is capable of.
If the application falls under
these categories, you can
use these charts. For other
applications, or when a
Standard Duty—15 Second Ramp, 4 Starts per Hour, 300% Current Limit at 40°C
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
2
3
230V380–400V 440V
690V is available only from T18 thru V85. Not available on U-Frames.
500A rating does not have IEC certification.
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Ramp Time
SecondsStarts per Hour
question arises, consult
with your local Eaton
representative or call our
Technical Resource Center.
200V230V460V575–690V
1.0SF1.15SF1.0SF1.15SF1.0SF1.15SF1.0SF1.15SF
Ambient
Temperature
1
1
1
1
1
1
1
1
1
1
1
Catalog
Number
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
3
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Standard Duty—25 Second Ramp, 4 Starts per Hour, 300% Current Limit at 40°C
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
2
3
230V380–400V 440V
690V is available only from T18 thru V85. Not available on U-Frames.
500A rating does not have IEC certification.
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
200V230V460V575–690V
1.0SF1.15SF1.0SF1.15SF1.0SF1.15SF1.0SF1.15SF
1
Catalog
Number
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Standard Duty—50 Second Ramp, 2 Starts per Hour, 300% Current Limit at 50°C