Cutler Hammer, Div of Eaton Corp S811 Part Numbering Designation

Catalog Number Selection
S 811 T 30 N 3 S
Frame Size
2
N = 65 mm R = 110 mm T = 200 mm U = 200 mm V = 290 mm
Ampere Rating
37 = 37A 66 = 66A 10 = 105A 13 = 135A 18 = 180A
24 = 240A 30 = 304A 36 = 360A 42 = 420A 50 = 500A
3
65 = 650A 72 = 720A 85 = 850A 10 = 1000A
S = Standard soft starter
(configurable for edge or level control)
D = Inside-the-delta L = Extended ramp start W = Without DIM
Number of Poles
3 = Three-pole device
Options
N = No options P = Pump control V = 690V option (Frame
T18 through V85)
4
S = Soft Starter
811 = Non-combination
soft starter
S811 Open Soft Starters
1
Notes
1
All units require a 24 Vdc power supply found on catalog Page V6-T1-107, or equivalent.
2
3
4
T-, U- and V-Frames require lug kits found on Page V6-T1-107. U-Frame 500A unit does not have IEC certification. Not available in U-Frame.
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Product Selection
Standard Duty Ratings
Starting Method
Soft start 300% 30 sec. 3 50°C
Full voltage 500% 10 sec. 3 50°C
Wye-delta 350% 20 sec. 3 50°C
80% RVAT 480% 20 sec. 2 50°C
65% RVAT 390% 20 sec. 3 50°C
50% RVAT 300% 20 sec. 4 50°C
Motor applications and customer needs come in many different varieties. With the standard and severe duty rating tables, we have attempted to provide
Ramp Current % of FLA
guidelines on what the soft starter is capable of. If the application falls under these categories, you can use these charts. For other applications, or when a
Standard Duty—15 Second Ramp, 4 Starts per Hour, 300% Current Limit at 40°C
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
37 10 18.5 18.5 10 10 10 10 25 20 30 30 S811N37N3S
66 18.5 30 37 20 15 20 20 50 40 60 50 S811N66N3S
Frame Size R
105 30 55 59 30254030756010075S811R10N3S
135 40 63 80 40 30 50 40 100 75 125 100 S811R13N3S
Frame Size T
180 51 90 110 60 50 60 60 150 125 150 150 S811T18N3S
240 75 110 147 75 60 75 75 200 150 200 200 S811T24N3S
304 90 160 185 100 75 100 100 250 200 300 250 S811T30N3S
Frame Size U
360 110 185 220 125 100 150 125 300 250 350 300 S811U36N3S
420 129 220 257 150 125 175 150 350 300 450 350 S811U42N3S
500 150 257 300 150 150 200 150 400 350 500 450 S811U50N3S
Frame Size V
360 110 185 220 125 100 150 125 300 250 350 300 S811V36N3S
420 129 220 257 150 125 175 150 350 300 450 350 S811V42N3S
500 150 257 300 150 150 200 150 400 350 500 450 S811V50N3S
650 200 355 425 250 200 250 200 500 450 600 500 S811V65N3S
720 220 400 450 300 250 600 500 700 600 S811V72N3S
850 257 475 500 350 300 700 600 900 700 S811V85N3S
1000 277 525 550 400 350 800 700 900 800 S811V10N3S
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
2
3
230V 380–400V 440V
690V is available only from T18 thru V85. Not available on U-Frames. 500A rating does not have IEC certification. For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Ramp Time Seconds Starts per Hour
question arises, consult with your local Eaton representative or call our Technical Resource Center.
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Ambient Temperature
1
1
1
1
1
1
1
1
1
1
1
Catalog Number
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
3
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Standard Duty—25 Second Ramp, 4 Starts per Hour, 300% Current Limit at 40°C
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
34 9 15 18.5 10 7-1/2 10 10 25 20 30 25 S811N37N3S
63 15 30 33 20 15 20 20 40 40 60 50 S811N66N3S
Frame Size R
96 25 45 55 30 25 30 30 75 60 75 75 S811R10N3S
120 33 63 63 403040407575100100S811R13N3S
Frame Size T
150 45 80 90 50405050100100150125S811T18N3S
215 63 11013260607560150150200150S811T24N3S
278 80 147 160 75 75 100 75 200 200 250 250 S811T30N3S
Frame Size U
320 90 160 185 100 75 125 100 250 200 300 250 S811U36N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811U42N3S
460 140 250 280 150 125 150 150 350 300 450 400 S811U50N3S
Frame Size V
320 90 160 185 100 75 125 100 250 200 300 250 S811V36N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811V42N3S
460 140 250 280 150 125 150 150 350 300 450 400 S811V50N3S
610 185 315 375 250 150 200 200 500 450 600 500 S811V65N3S
680 200 375 445 200 250 200 600 500 700 600 S811V72N3S
810 250 450 500 300 300 700 600 900 700 S811V85N3S
890 290 510 560 400 350 700 600 900 700 S811V10N3S
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
690V is available only from T18 thru V85. Not available on U-Frames.
2
500A rating does not have IEC certification.
3
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
230V 380–400V 440V
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
1
Catalog Number
2
3
1
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Standard Duty—15 Second Ramp, 4 Starts per Hour, 300% Current Limit at 50°C
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
34 9 15 18.5 10 7-1/2 10 10 25 20 30 25 S811N37N3S
63 15 30 33 20 15 20 20 40 40 60 50 S811N66N3S
Frame Size R
96 25 45 55 30 25 30 30 75 60 75 75 S811R10N3S
120 33 63 63 403040407575100100S811R13N3S
Frame Size T
150 45 80 90 50405050100100150125S811T18N3S
215 63 110 132 60 60 75 60 150 150 200 150 S811T24N3S
278 80 147 160 75 75 100 75 200 200 250 250 S811T30N3S
Frame Size U
320 90 160 185 100 75 125 100 250 200 300 250 S811U36N3S
460 110 200 220 125 100 150 125 300 250 350 300 S811U42N3S
460 140 250 280 150 125 150 150 350 300 450 400 S811U50N3S
Frame Size V
320 90 160 185 100 75 125 100 250 200 300 250 S811V36N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811V42N3S
460 140 250 280 150 125 150 150 350 300 450 400 S811V50N3S
610 185 315 375 250 150 200 200 500 450 600 500 S811V65N3S
680 200 375 445 200 250 200 600 500 700 600 S811V72N3S
830 257 450 500 300 300 700 600 900 700 S811V85N3S
960 302 510 540 350 300 800 700 900 800 S811V10N3S
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
2
3
230V 380–400V 440V
690V is available only from T18 thru V85. Not available on U-Frames. 500A rating does not have IEC certification. For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
1
Catalog Number
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Standard Duty—50 Second Ramp, 2 Starts per Hour, 300% Current Limit at 50°C
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
21 5.51011555515101515S811N37N3S
42 11 18.5 22 10 10 15 10 30 25 40 30 S811N66N3S
Frame Size R
60 15 30 33 15 15 20 15 40 40 50 50 S811R10N3S
80 22 40 45 25 20 30 25 60 50 75 60 S811R13N3S
Frame Size T
115 33 59 63 303040307575100100S811T18N3S
150 45 80 90 50405050100100150125S811T24N3S
192 55 10011060506060150125200150S811T30N3S
Frame Size U
280 80 150 160 75 75 100 75 200 200 250 250 S811U36N3S
340 110 180 200 100 100 125 100 250 200 350 300 S811U42N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811U50N3S
Frame Size V
280 80 150 160 75 75 100 75 200 200 250 250 S811V36N3S
340 110 180 200 100 100 125 100 250 200 350 300 S811V42N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811V50N3S
420 129 220 257 150 125 150 150 350 300 450 350 S811V65N3S
480 147 257 295 150 150 200 150 400 350 500 450 S811V72N3S
590 180 315 375 200 150 200 200 500 400 600 500 S811V85N3S
650 205 370 415 250 200 250 200 500 450 600 500 S811V10N3S
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
690V is available only from T18 thru V85. Not available on U-Frames.
2
500A rating does not have IEC certification.
3
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
230V 380–400V 440V
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
1
Catalog Number
2
3
1
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Standard Duty—15 Second Ramp, 4 Starts per Hour, 450% Current Limit at 40°C
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
29 7.5 12.5 15 7-1/2 7-1/2 10 7-1/2 20 15 25 20 S811N37N3S
49 12.5 22 25 15 10 15 15 30 30 40 40 S811N66N3S
Frame Size R
73 18.5 37 40 20 20 25 20 50 40 60 60 S811R10N3S
94 25 45 55 30 25 30 30 60 60 75 75 S811R13N3S
Frame Size T
155 45 80 90 50406050100100150125S811T18N3S
219 63 110 132 60 60 75 60 150 150 200 150 S811T24N3S
280 80 150 160 75 75 100 75 200 200 250 250 S811T30N3S
Frame Size U
345 100 185 200 100 100 125 100 250 200 350 300 S811U36N3S
405 110 200 250 125 100 150 125 300 250 400 350 S811U42N3S
Frame Size V
345 100 185 200 100 100 125 100 250 200 350 300 S811V36N3S
405 110 200 250 125 100 150 125 300 250 400 350 S811V42N3S
465 140 250 280 150 125 150 150 350 300 450 400 S811V50N3S
530 160 280 335 150 150 200 150 450 350 500 450 S811V65N3S
590 180 315 375 200 150 200 500 400 600 500 S811V72N3S
651 200355425————600450700600S811V85N3S
754 220400465————600500800700S811V10N3S
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
2
230V 380–400V 440V
690V is available only from T18 thru V85. Not available on U-Frames. For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
1
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Standard Duty—30 Second Ramp, 4 Starts per Hour, 450% Current Limit at 40°C
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
21 5.51012.5555515101515S811N37N3S
40 11 18.5 22 10 10 10 10 30 25 30 30 S811N66N3S
Frame Size R
55 15 25 30 15 15 20 15 40 30 50 40 S811R10N3S
75 22 37 45 20 20 25 20 50 50 60 60 S811R13N3S
Frame Size T
151 45 80 90 50405050100100150125S811T18N3S
215 63 11013260607560150150200150S811T24N3S
264 80 140 160 75 75 100 75 200 150 250 200 S811T30N3S
Frame Size U
300 90 160 185 100 75 100 100 200 200 300 250 S811U36N3S
340 100 180 200 100 100 125 100 250 200 350 300 S811U42N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811U50N3S
Frame Size V
300 90 160 185 100 75 100 100 200 200 300 250 S811V36N3S
340 100 180 200 100 100 125 100 250 200 350 300 S811V42N3S
380 110 200 220 125 100 150 125 300 250 350 300 S811V50N3S
420 129 220 257 150 125 150 150 350 300 450 350 S811V65N3S
460 140 250 280 150 125 150 150 350 300 450 400 S811V72N3S
500 150 257 300 150 150 200 150 400 350 500 450 S811V85N3S
560 160 277 325 200 150 250 200 500 400 600 500 S811V10N3S
For Pump Option, replace character 8 with “P” and also, see Pa ge V 6-T 1-108.
Notes
1
690V is available only from T18 thru V85. Not available on U-Frames.
2
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
230V 380–400V 440V
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
1
Catalog Number
2
1
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Severe Duty
Severe Duty Ratings
Starting Method
Soft start 450% 30 sec. 4 50°C
Full voltage 500% 10 sec. 10 50°C
Wye-delta 350% 65 sec. 3 50°C
80% RVAT 480% 25 sec. 4 50°C
65% RVAT 390% 40 sec. 4 50°C
50% RVAT 300% 60 sec. 4 50°C
Severe duty ratings are defined as any combination of parameters that exceed the standard duty ratings where
Ramp Current % of FLA
the ramp time is over 30 seconds, the number of starts per hour exceeds 4, or the current limit set is over
Severe Duty—>30 Second Ramp, >4 Starts per Hour or >300% Current Limit
Three-Phase Motors kW Rating (50 Hz) hp Rating (60 Hz)
Max. Current
Frame Size N
22 5.510 11 5 5 7-1/25 15102015S811N37N3S
42 11 18.5 22 10 10 15 10 30 25 40 30 S811N66N3S
Frame Size R
65 15 30 33 15 15 20 15 50 40 50 50 S811R10N3S
80 22 40 45 25 20 30 25 60 50 75 60 S811R13N3S
Frame Size T
115 33 59 63 303040307575100100S811T18N3S
150 45 80 90 50405050100100150125S811T24N3S
192 55 100 110 60 50 75 60 150 125 200 150 S811T30N3S
Frame Size U
240 75 110 147 75 60 75 75 200 150 200 200 S811U36N3S
305 90 160 185 100 75 100 100 250 200 300 250 S811U42N3S
Frame Size V
240 75 110 147 75 60 75 75 200 150 200 200 S811V36N3S
305 90 160 185 100 75 100 100 250 200 300 250 S811V42N3S
365 110 185 220 125 100 150 125 300 250 350 300 S811V50N3S
420 129 220 257 150 125 150 150 350 300 450 350 S811V65N3S
480 147 257 295 150 150 200 150 400 350 500 450 S811V72N3S
525 160 280 335 150 150 200 150 450 350 500 450 S811V85N3S
575 172 303 370 200 150 250 200 500 450 600 500 S811V10N3S
Notes
1
2
230V 380–400V 440V
690V is available only from T18 thru V85. Not available on U-Frames. For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Ramp Time Seconds Starts per Hour
300%. Example: 35-second ramp, 5 starts per hour, 350% current limit at 40°C ambient.
200V 230V 460V 575–690V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Ambient Temperature
1
1
1
1
1
1
1
1
1
1
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1.2
S811
Inside-the-Delta Standard Duty Ratings
1
Inside-the-Delta Standard Duty—15 Second Ramp, 4 Starts per Hour,
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
300% Current Limit at 40°C Ambient
Max. Continuous Motor Line Current
Frame Size N
65 10 18.518.51515151540305050S811N37N3D
114 18.5 30 37 30253030756010075S811N66N3D
Frame Size R
182 30 55 59 50406050125100150125S811R10N3D
234 40 63 80 60507560150125200150S811R13N3D
Frame Size T
311 51 90 110 100 75 100 100 250 200 250 250 S811T18N3D
415 75 110 147 125 100 125 125 300 250 300 300 S811T24N3D
526 90 160 185 150 125 150 150 400 300 400 400 S811T30N3D
Frame Size U
623 110 185 220 200 150 250 200 450 400 550 450 S811U36N3D
727 129 220 257 250 200 300 250 550 450 700 550 S811U42N3D
865 150 257 300 250 250 300 250 600 550 750 700 S811U50N3D
Frame Size V
623 110 185 220 200 150 250 200 450 400 550 450 S811V36N3D
727 129 220 257 250 200 300 250 550 450 700 550 S811V42N3D
865 150 257 300 250 250 300 250 600 550 750 700 S811V50N3D
1125 200 355 425 400 300 400 300 750 700 900 750 S811V65N3D
1246 — — — ————————S811V72N3D
1471 — — — ————————S811V85N3D
— — — ————————S811V10N3D
Notes
1
2
3
Reduced Voltage Motor Starters
Solid-State Starters
Three-Phase Motor kW Rating (50 Hz) hp Rating (60 Hz)
200V230V460V575V
230V 380–400V 440V
15 sec. start, 300% inrush, 40°C, 1 start every 15 minutes. If these start parameters are exceeded, please refer to 290 mm V-Frame, 865A inside-the-delta starter. U-Frame 500A unit does not have IEC certification. For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Catalog Number
12
3
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Inside-the-Delta Standard Duty—25 Second Ramp, 4 Starts per Hour, 300% Current Limit at 40°C Ambient
Max. Continuous Motor Line Current
Frame Size N
58 9 15 18.51510151540305040S811N37N3D
108 15 30 33 30253030606010075S811N66N3D
Frame Size R
164 25 45 55 50405050125100125125S811R10N3D
206 33 63 63 60506050125125150150S811R13N3D
Frame Size T
257 45 80 90 75607560150150250200S811T18N3D
365 63 110 132 100 100 125 100 250 250 300 250 S811T24N3D
477 80 147 160 125 125 150 125 300 300 400 400 S811T30N3D
Frame Size U
554 90 160 185 150 125 200 150 400 300 450 400 S811U36N3D
646 110 200 220 200 150 250 200 500 400 550 450 S811U42N3D
796 140 250 280 250 200 250 250 550 500 700 600 S811U50N3D
Frame Size V
554 90 160 185 150 125 200 150 400 300 450 400 S811V36N3D
646 110 200 220 200 150 250 200 500 400 550 450 S811V42N3D
796 140 250 280 250 200 250 250 550 500 700 600 S811V50N3D
1055 185 315 375 400 250 300 300 800 700 900 750 S811V65N3D
1176 200 375 445 300 400 300 900 800 900 900 S811V72N3D
1358 — — — ————————S811V85N3D
— — — ————————S811V10N3D
Notes
1
15 sec. start, 300% inrush, 40°C, 1 start every 15 minutes. If these start parameters are exceeded, please refer to 290 mm V-Frame, 796A inside-the-delta starter.
2
U-Frame 500A unit does not have IEC certification.
3
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Three-Phase Motor kW Rating (50 Hz) hp Rating (60 Hz)
200V 230V 460V 575V
230V 380–400V 440V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Catalog Number
12
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Inside-the-Delta Standard Duty—15 Second Ramp, 4 Starts per Hour, 300% Current Limit at 50°C Ambient
Max. Continuous Motor Line Current
Frame Size N
58 9 15 18.51510151540305040S811N37N3D
108 15 30 33 30253030606010075S811N66N3D
Frame Size R
164 25 45 55 50405050125100125125S811R10N3D
206 33 63 63 60506060125125150150S811R13N3D
Frame Size T
257 45 80 90 75607575150150250200S811T18N3D
365 63 110 132 100 100 125 100 250 250 300 250 S811T24N3D
477 80 147 160 125 125 150 125 300 300 400 400 S811T30N3D
Frame Size U
554 90 160 185 150 125 200 150 400 300 450 400 S811U36N3D
646 110 200 220 200 150 250 200 450 400 550 450 S811U42N3D
796 140 250 280 250 200 250 250 550 450 700 600 S811U50N3D
Frame Size V
554 90 160 185 150 125 200 150 400 300 450 400 S811V36N3D
646 110 200 220 200 150 250 200 450 400 550 450 S811V42N3D
796 140 250 280 250 200 250 250 550 450 700 600 S811V50N3D
1055 185 315 375 400 250 300 300 750 700 900 750 S811V65N3D
1176 200 375 445 S811V72N3D
1358 257 450 500 S811V85N3D
— — — ————————S811V10N3D
Notes
1
U-Frame 500A unit does not have IEC certification.
2
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
Three-Phase Motor kW Rating (50 Hz) hp Rating (60 Hz)
200V 230V 460V 575V
230V 380–400V 440V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Catalog Number
1
2
1
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Inside-the-Delta Standard Duty—50 Second Ramp, 2 Starts per Hour, 300% Current Limit at 50°C Ambient
Three-Phase Motor
Max. Continuous Motor Line Current
Frame Size N
36 5.5 10 11 7-1/2 7-1/2 7-1/2 7-1/2 25 15 25 25 S811N37N3D
73 11 18.522 1515251550406050S811N66N3D
Frame Size R
103 15 30 33 2525302560607575S811R10N3D
138 22 40 45 40 30 50 40 100 75 125 100 S811R13N3D
Frame Size T
199 33 59 63 50 50 60 50 125 125 150 150 S811T18N3D
257 45 80 90 75 60 75 75 150 150 250 200 S811T24N3D
324 55 100 110 100 75 100 100 250 200 300 250 S811T30N3D
Frame Size U
485 80 150 160 125 125 150 125 300 300 400 400 S811U36N3D
580 100 180 200 150 150 200 150 400 300 550 450 S811U42N3D
646 110 200 220 200 150 250 200 450 400 550 450 S811U50N3D
Frame Size V
485 80 150 160 125 125 150 125 300 300 400 400 S811V36N3D
580 100 180 200 150 150 200 150 400 300 550 450 S811V42N3D
646 110 200 220 200 150 250 200 450 400 550 450 S811V50N3D
727 129 220 257 250 200 250 250 550 500 700 550 S811V65N3D
816 147 257 295 250 250 300 250 600 550 750 700 S811V72N3D
1021 180 315 375 300 250 300 300 750 600 900 750 S811V85N3D
———————————S811V10N3D
Notes
1
U-Frame 500A unit does not have IEC certification.
2
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
kW Rating (50 Hz) hp Rating (60 Hz)
200V 230V 460V 575V
230V 380–400V 440V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
S811
Reduced Voltage Motor Starters
Solid-State Starters
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Inside-the-Delta Standard Duty—15 Second Ramp, 4 Starts per Hour, 450% Current Limit at 40°C Ambient
Three-Phase Motor
Max. Continuous Motor Line Current
Frame Size N
47 7.5 12.515 1010151030254030S811N37N3D
83 12.522 25 2515252550506060S811N66N3D
Frame Size R
126 18.537 40 303040307560100100S811R10N3D
162 25 45 55 50 40 50 50 100 100 125 125 S811R13N3D
Frame Size T
266 45 80 90 75 60 100 75 150 150 250 200 S811T18N3D
379 63 110 132 100 100 125 100 250 250 300 250 S811T24N3D
485 80 150 160 125 125 150 125 300 300 400 400 S811T30N3D
Frame Size U
580 100 185 200 150 150 200 150 400 300 550 450 S811U36N3D
695 110 200 250 200 150 250 200 450 400 600 550 S811U42N3D
798 140 250 280 250 200 250 250 550 450 700 600 S811U50N3D
Frame Size V
580 100 185 200 150 150 200 150 400 300 550 450 S811V36N3D
695 110 200 250 200 150 250 200 450 400 600 550 S811V42N3D
798 140 250 280 250 200 250 250 550 450 700 600 S811V50N3D
908 160 280 335 250 250 300 250 700 550 750 700 S811V65N3D
1021 — — — ————————S811V72N3D
1125 — — — ————————S811V85N3D
Note
1
U-Frame 500A unit does not have IEC certification.
kW Rating (50 Hz) hp Rating (60 Hz)
200V 230V 460V 575V
230V 380–400V 440V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
S811
Solid-State Starters
1.2
Inside-the-Delta Standard Duty—30 Second Ramp, 4 Starts per Hour, 450% Current Limit at 40°C Ambient
Three-Phase Motor
Max. Continuous Motor Line Current
Frame Size N
36 5.5 10 12.5 7-1/2 7-1/2 7-1/2 7-1/2 25 15 25 25 S811N37N3D
69 11 18.522 1515151550405050S811N66N3D
Frame Size R
96 15 25 30 25 25 30 25 60 50 75 60 S811R10N3D
130 22 37 45 303040307575100100S811R13N3D
Frame Size T
257 45 80 90 75 60 75 75 150 150 250 200 S811T18N3D
365 63 110 132 100 100 125 100 250 250 300 250 S811T24N3D
448 80 140 160 125 125 150 125 300 250 400 300 S811T30N3D
Frame Size U
503 90 160 185 150 125 150 150 300 300 450 400 S811U36N3D
580 100 180 200 150 150 200 150 400 300 550 450 S811U42N3D
646 110 200 220 200 150 250 200 450 400 550 450 S811U50N3D
Frame Size V
503 90 160 185 150 125 150 150 300 300 450 400 S811V36N3D
580 100 180 200 150 150 200 150 400 300 550 450 S811V42N3D
646 110 200 220 200 150 250 200 450 400 550 450 S811V50N3D
727 129 220 257 250 200 250 250 550 450 700 550 S811V65N3D
796 — — — ————————S811V72N3D
865 — — — ————————S811V85N3D
Note
1
U-Frame 500A unit does not have IEC certification.
kW Rating (50 Hz) hp Rating (60 Hz)
200V 230V 460V 575V
230V 380–400V 440V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
S811
Inside-the-Delta Severe Duty Ratings
1
Severe duty ratings are defined as any combination of
1
parameters that exceed the standard duty ratings where the ramp time is over 30
1
seconds, the number of starts per hour exceeds 4, or
1
the current limit set is over 300%.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reduced Voltage Motor Starters
Solid-State Starters
Example: 35-second ramp, 5 starts per hour 350% current limit at 40°C ambient.
Inside-the-Delta Severe Duty
Three-Phase Motor
Max. Continuous Motor Line Current
Frame Size N
39 5.5 10 11 7-1/2 7-1/2 10 7-1/2 25 15 30 25 S811N37N3D
73 11 18.5 22 15 15 25 15 50 40 60 50 S811N66N3D
Frame Size R
111 15 30 33 2525302575607575S811R10N3D
138 22 40 45 4030504010075120100S811R13N3D
Frame Size T
199 33 59 63 50506050125125150150S811T18N3D
257 45 80 90 75607575150150250200S811T24N3D
324 55 100 110 100 75 100 100 250 200 300 250 S811T30N3D
Frame Size U
415 75 110 147 125 100 125 125 300 250 300 300 S811U36N3D
526 90 160 185 150 120 150 150 400 300 450 400 S811U42N3D
623 110 185 220 200 150 250 200 450 400 550 450 S811U50N3D
Frame Size V
415 75 110 147 125 100 125 125 300 250 300 300 S811V36N3D
526 90 160 185 150 120 150 150 400 300 450 400 S811V42N3D
623 110 185 220 200 150 250 200 450 400 550 450 S811V50N3D
727 129 220 257 250 200 250 250 550 450 700 550 S811V65N3D
816 147 257 295 250 250 300 250 600 550 750 700 S811V72N3D
908 160 280 335 250 250 300 250 700 550 750 700 S811V85N3D
— — — ————————S811V10N3D
Notes
1
U-Frame 500A unit does not have IEC certification.
2
For more information on optimum performance of the 1000A Frame Size V S811, see Appendix E of MN03902002E.
kW Rating (50 Hz) hp Rating (60 Hz)
200V 230V 460V 575V
230V 380–400V 440V
1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF 1.0SF 1.15SF