Type S752, Intelligent
Product Description. . . . . . . 39-14
Application Description. . . . 39-14
Features and Benefits . . . . . 39-14
Operation . . . . . . . . . . . . . . 39-16
Catalog Number
Selection . . . . . . . . . . . . . . 39-16
Product Selection . . . . . . . . 39-17
Accessories . . . . . . . . . . . . . 39-19
Renewal Parts . . . . . . . . . . . 39-19
Standards and
Certifications . . . . . . . . . . . 39-19
Instructional Leaflets . . . . . . 39-19
Technical Data and
Specifications . . . . . . . . . . 39-20
Dimensions . . . . . . . . . . . . . 39-21
S752
Product Description
Eaton’s Cutler-Hammer® Intelligent Technologies (IT.) S752 Line of Reduced Voltage Soft Starters is very compact, multi-functional, easy to install and easy to program. Designed to control the acceleration and deceler­ation of three-phase motors, the device is available in configurations to be applied either in the line of the motor, or in the delta windings of the motor. The in-line device is available for current ranges from 0.25 to 50 amps. The inside-the-delta device is available for current ranges from 0.44 to 78 amps.
The S752 is a redesign of the popular S751 soft starter. Design enhance­ments include an increased current rating, short circuit coordination ratings with breakers and fuses, and inside-the-delta control. The S752 has replaced the S751 in the Cutler­Hammer product offering.
The S752 is designed to be a complete package combining the SCRs, bypass contactor and overload in one, very compact device. The S752 is available as a component for panel mounting, in Motor Control Centers or in Enclosed Control (NEMA Type 1, 3R, 4, 4X, 7/9 and 12).
Application Description
The S752 combines the soft starter overload, bypass contactor into one device for fast and easy installation. With its small size, it can easily fit in place of existing soft starters, wye­delta starters or across-the-line NEMA and IEC starters. This feature allows easy upgrades to existing systems.
The in-line version is designed for use with three-phase motors in a delta (three-lead) configuration. The product is designed to be wired in the three­phase line feeding the three motor input leads as is done for normal across-the-line starting.
The inside-the-delta version is to be used on 6-lead or 12-lead wye-delta motors. The device is wired into the windings of the motor. A reduced voltage start is achieved without the need to reconnect the motor in wye and delta configurations. The S752 offers enhanced performance over traditional wye-delta electromechani­cal starters.
The starter uses Silicon Controlled Rectifiers (SCRs) to ramp the voltage to the motor, providing smooth accel­eration and deceleration of the load. After the motor is started, the internal run bypass contactor closes, resulting in the motor running directly across­the-line. Internal run bypass signifi­cantly reduces the heat generated as compared to non-bypass starters. The soft stop option allows for a ramp stop time that is longer than the coast­to-stop time.
The built-in solid-state overload pro­tects the motor from overload condi­tions with sophisticated algorithms that model true motor heating, result­ing in better motor protection and fewer nuisance trips. Advanced pro­tective and diagnostic features reduce downtime.
The S752 was designed with safety in mind. The device features a fully motor-rated run bypass contactor. The bypass contactor is capable of break­ing the motor load in failed SCR condi­tions. Short circuit protection ratings are offered with both circuit breakers and fuses. Safety is enhanced with the use of green materials, 24V DC control and finger safe IP20 terminals.
Features and Benefits
Run bypass significantly reduces the
heat generated as compared to non- bypass soft starters. Less heat mini- mizes enclosure size and cooling requirements and maximizes the life of all devices in the enclosure.
Run bypass mode greatly reduces
internal heating created by the power dissipation across the SCRs. The bypass contactor directly connects the motor to the line and improves system efficiency by reducing internal power losses.
Solid-state overload protection pro-
vides accurate current measure- ment and trip settings. Sophisticated algorithms solve a series of differential equations that
model true motor heating and cool- ing, resulting in superior motor over- load protection while minimizing nuisance trips. Advanced selectable protective features safeguard the motor and system against a variety
of system faults.
Six SCRs control all three motor
phases providing smooth accelera- tion and deceleration performance.
Easy to read LED displays device
status and provides fault indication.
Internal run bypass contactors and overload protection eliminate the need for additional devices, thereby reducing enclosure sizes, minimizing installation and wiring time and reducing overall assem- bly size and cost.
Variable ramp times and torque
control settings provide unlimited starting configurations, allowing for maximum application flexibility.
Soft stop control suits applications
where an abrupt stop of the load is not acceptable.