Rotary Disconnects
2.68
(68.0)
F
T
M5
M
N
G
AC
3.19
(81.0)
2.52
(64.0)
0.24
(6.0)
1.97
(50.0)
2.87
(73.0)
F1
F1
0.35
(8.8)
0.35
(8.8)
90
E
1.45
(37.0)
3.19
(81.0)
2.52
(64.0)
0.23
(6.0)
1.96
(50.0)
1.99
(50.6)
R5 Series (UL 508) Non-Fusible 16–80A
8.2
Dimensions
Approximate Dimensions in Inches (mm)
R5 Series 16–80A
Toggle Operation Direct Operation with Handle
2.95
(75.0)
2.52
(64.0)
1
External Front Operation External Side Operation
1
G
2.67
(68.0)
0.35
G
0.35
(8.8)
2.68
(68.0)
1.97
(50.0)
1
F1
M5
(8.8)
0.24
(6.0)
F
M
J
F1
T
M5
D
1
N
AC
0.35
(8.8)
8
8
8
8
F
M
1
1
8
8
N
AC
0.35
(8.8)
F1F1
T
8
8
8
8
8
1.42
(36.0)
8
8
8
Ø2.79
(Ø71.0)
8
8
8
R5 Series
Ampere
Rating D Min. D Max. E Min. E Max. AC F F1 G J M N T
16–40 1.18 (30.0) 9.25 (235.0) 3.94 (100.0) 14.65 (372.0) 4.33 (110.0) 1.77 (45.0) 0.59 (15.0) 2.68 (68.0) 0.59 (15.0) 1.18 (30.0) 2.95 (75.0) 0.59 (15.0)
63–80 1.18 (30.0) 9.25 (235.0) 3.94 (100.0) 14.65 (372.0) 4.33 (110.0) 2.06 (52.5) 0.69 (17.5) 2.99 (76.0) 0.69 (17.5) 1.38 (35.0) 3.35 (85.0) 0.69 (17.5)
Notes
1
One switched fourth-pole module (one per device maximum) or one unswitched neutral pole or one auxiliary contact.
2
Maximum four additional blocks.
2
Overall Dimensions Terminal Shrouds Switch Body Switch Mounting Connection Terminal
8
8
8
8
8
8
8
8
8
8
8
8
8
Rotary Disconnects
1.42
(36.0)
E
1.77
(45.0)
3.07
(78.0)
1.36
(34.7)
1.69
(43.0)
0.24
(6.0)
3.50
(89.0)
Ø2.79
(Ø71.0)
X
N
G
2.67
(68.0)
TT
0.29
(7.5)
2.06
(52.5)
M
F2
2.06
(52.5)
F
J
F1
F1
0.35
(8.8)
0.35
(8.8)
0.53
(13.5)
0.12
(3.0)
Ø0.89
(22.5)
1.57
(40.0)
Ø0.28
(7.0)
Ø1.22
(31.0)
1. 10
(28.0)
0.16
(4.0)
8.2
Approximate Dimensions in Inches (mm)
8
Direct Front Operation for 6/8-Pole R5 Load Break
8
Switches or 3/4-Pole R5 Changeover Switches External Front Operation
8
R5 Series (UL 508) Non-Fusible 16–80A
8
1
2
1
2
8
8
8
8
8
R5 Series
8
Ampere Rating E Min. E Max. F F1 F2 G J M N T X
16–40 4.13 (105.0) 14.64 (372.0) 3.83 (97.5) 0.59 (15.0) 1.77 (45.0) 2.67 (68.0) 1.92 (48.8) 1.18 (30.0) 2.95 (75.0) 0.59 (15.0) 0.29 (7.5)
8
63–80 4.13 (105.0) 14.65 (372.0) 4.13 (105.0) 0.69 (17.5) 2.06 (52.5) 2.99 (76.0) 2.06 (52.5) 1.38 (35.0) 3.35 (85.0) 0.69 (17.5) 0.34 (8.8)
3
Overall Dimensions Switch Body Switch Mounting Connection Terminals
8
Door Drilling—SH00/SH0
8
With Fixing Nut With Four Fixing Screws
8
8
8
8
8
8
Operating Handle—SH00/SH0
8
8
Front and Right Side Operation I–0–II or I–I+II–II
Front Operation for R5
Changeover Switches
8
8
8
8
8
Notes
8
1
One switched fourth-pole module (one per device maximum) or one unswitched neutral pole.
2
3
8
8
8
Auxiliary contact.
Maximum four additional blocks.