Electrical Sector Solutions
Volume 4:
Circuit
Protection
4
Volume 1—Residential and Light Commercial
1
Volume 2—Commercial Distribution
Volume 3—Power Distribution and Control Assemblies
Volume 4—Circuit Protection
Tab 1—Miniature Circuit Breakers and
Supplementary Protectors . . . . . . . . . . . V4-T1-1
Tab 2—Molded Case Circuit Breakers . . . . . . . . . . . . V4-T2-1
Tab 3—Power Breakers, Contactors and Fuses
Appendix 1—Eaton Terms & Conditions
Appendix 2—Catalog Parent Number Index . . . . . . . V4-A2-1
Appendix 3—Alphabetical Product Index . . . . . . . . . V4-A3-1
. . . . . . . . . .
. . . . .
V4-T3-1
V4-A1-1
2
3
4
Volume 5—Motor Control and Protection
Volume 6—Solid-State Motor Control
Volume 7—Logic Control, Operator
Interface and Connectivity Solutions
5
6
7
Copyright
Dimensions, Weights and Ratings
Terms and Conditions
Technical and Descriptive Publications
Dimensions, weights and ratings given in this catalog are approximate and should not
be used for construction purposes
upon request. All listed product specifications and ratings are subject to change without
notice. Photographs are representative of production units.
All prices and discounts are subject to change without notice. When price changes
occur, they are published in Eaton’s Price and Availability Digest (PAD). All orders
accepted by Eaton’s Electrical Sector are subject to the general terms and conditions
as set forth in Appendix 1—Eaton Terms & Conditions.
This catalog contains brief technical data for proper selection of products. Further
information is available in the form of technical information publications and illustrated
brochures. If additional product information is required, contact your local Eaton
Products Distributor, call 1-800-525-2000 or visit our website at
. Drawings containing exact dimensions are available
Compliance with Nuclear Regulation 10 CFR 21
Eaton products are sold as commercial grade products not intended for application in
facilities or activities licensed by the United States Nuclear Regulatory Commission
for atomic purposes, under 10 CFR 21. Further certification will be required for use of
these products in a safety-related application in any nuclear facility licensed by the
U.S. Nuclear Regulatory Commission.
WARNING
The installation and use of Eaton products should be in accordance with the provisions
of the U.S. National Electrical Code
are pertinent to the particular end use. Installation or use not in accordance with these
codes and standards could be hazardous to personnel and/or equipment.
These catalog pages do not purport to cover all details or variations in equipment, nor to provide for
every possible contingency to be met in connection with installation, operation or maintenance.
Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser’s purposes, the matter should be referred to the local Eaton Products
Distributor or Sales Office. The contents of this catalog shall not become part of or modify any prior
or existing agreement, commitment or relationship. The sales contract contains the entire
obligation of Eaton’s Electrical Sector. The warranty contained in the contract between the parties
is the sole warranty of Eaton. Any statements contained herein do not create new warranties or
modify the existing warranty.
®
and/or other local codes or industry standards that
Copyright ©2019 Eaton, All Rights Reserved.
Eaton is a global leader in power distribution, power quality,
control and automation, and monitoring products.
At Eaton, we believe a reliable, efficient and safe power system is the foundation of every
successful enterprise. Through innovative technologies, cutting-edge products and our highly
skilled services team, we empower businesses around the world to achieve a powerful advantage.
In addition, Eaton is committed to creating and maintaining powerful customer relationships built
on a foundation of excellence. From the products we manufacture to our dedicated customer
service and support, we know what’s important to you.
Solutions
Eaton takes the complexity out of power systems management with a holistic and strategic
approach, leveraging our industry-leading technology, solutions and services. We focus on
the following three areas in all we do:
●
Reliability—maintain the
appropriate level of power
continuity without
disruption or unexpected
downtime
●
Efficiency—minimize
energy usage, operating
costs, equipment footprint
and environmental impact
●
Safety—identify and
mitigate electrical hazards
to protect what you value
most
Introduction
Using the Eaton Catalog Library
As we grow, it becomes increasingly difficult to include all products in one or two comprehensive
catalogs. Knowing that each user has their specific needs, we have created a library of catalogs for our
products that when complete, will contain 15 volumes. Since the volumes will continuously be a work
in progress and updated, each volume will stand alone. Refer to our volume directory, MZ08100001E,
for a quick glance of where to look for the products you need. The 15 volumes include:
●
Volume 1—Residential
and Light Commercial
(CA08100002E)
●
Volume 2—Commercial
Distribution (CA08100003E)
●
Vol ume 3—Power
Distribution and Control
Assemblies (CA08100004E)
●
Volume 4—Circuit
Protection (CA08100005E)
●
Volume 5—Motor Control
and Protection
(CA08100006E)
●
Volume 6—Solid-State
Motor Control
(CA08100007E)
These volumes are not all-inclusive of every product, but they are meant to be an overview
of our product lines. For our full range of product solutions and additional product information,
consult Eaton.com/electrical and other catalogs and product guides in our literature library.
These references include:
●
The Consulting Application
Guide (CA08104001E)
●
Volume 7—Logic Control,
Operator Interface and
Connectivity Solutions
(CA08100008E)
●
Volume 8—Sensing
Solutions (CA08100010E)
●
Volume 9—Original
Equipment Manufacturer
(CA08100011E)
●
Volume 10—Enclosed
Control (CA08100012E)
●
Volume 11—Vehicle and
Commercial Controls
(CA08100013E)
●
The Eaton Power Quality
Product Guide (COR01FYA)
●
Volume 12—Aftermarket,
Renewal Parts and Life
Extension Solutions
(CA08100014E)
●
Volume 13—Counters,
Timers and Tachometers
(CA08100015E)—Available
in electronic format only
●
Vol ume 14—Fuses
(CA08100016E)—Available
in electronic format only
●
Volume 15—Solar Inverters
and Electrical Balance of
System (CA08100018E)
If you don’t have the volume that contains the product or information that you are looking for,
not to worry. You can access every volume of the catalog library at Eaton.com/electrical in the
Literature Library.
By installing our Automatic Tab Updater (ATU), you can be sure you always have the most recent
version of each volume and tab.
Volume 4—Circuit Protection CA08100005E—April 2019 i
Introduction
Icons
Green Leaf
Eaton Green Solutions are products, systems or solutions that represent Eaton
benchmarks for environmental performance. The green leaf symbol is our
promise that the solution has been reviewed and documented as offering
exceptional, industry-leading environmental benefits to customers, consumers
and our communities. Though all of Eaton’s products and solutions are
designed to meet or exceed applicable government standards related to
protecting the environment, our products with the Green Leaf designation
further provide “exceptional environmental benefit.”
Learn Online
When you see the Learn Online icon, go to Eaton.com/electrical and search for
the product or training page. There you will find 100-level training courses,
podcasts, webcasts or games and puzzles to learn more.
Drawings Online
When you see the Drawings Online icon, go to Eaton.com/electrical and find the
products page. There you will find a tab that includes helpful product drawings
and illustrations.
Contact Us
If you need additional help, you can find contact information
under the Customer Care heading of Eaton.com/electrical.
ii Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and
Miniature Circuit Breakers and
Supplementary Protectors
Supplementary Protectors
1.1 Industrial Circuit Breakers
QUICKLAG® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW . . . . . . . . . . . V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPHGFT, QPHGFT, QPGFEP, QPHGFEP . . . . . . . . . . . . . . . . . V4-T1-8
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . . . . . . . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF . . . . . . . . . . V4-T1-14
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . . . . . . . . . . . . . . . V4-T1-16
Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW . . . . . . . . V4-T1-19
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-23
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . . . . . . . . . . . . . . . V4-T1-27
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP . . . . . . . . . . . . . . . . . . . . . . V4-T1-30
Solenoid Operator—Remote-Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers . . . . . . . . . . . . . . . . . . . . V4-T1-33
International Rated Types HQP, BA, QC, GFMB, GFXBC . . . . . . . . . . . V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . . . . . . . . . . . . . . V4-T1-39
1.2 UL 489 DIN Rail Miniature Circuit Breakers
FAZ-NA and FAZ-NA-L Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-47
1.3 UL 1077 DIN Rail Supplementary Protectors
FAZ Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-74
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.4 UL 1053 DIN Rail RCCB
UL 1053 DIN Rail RCCB 480/277 Vac . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-94
UL 1053 DIN Rail RCCB 208Y/120 Vac . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-100
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-1
1.1
Miniature Circuit Breakers and Supplementary Protectors
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG
Quick Reference
1
Eaton’s QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out
1
Circuit
1
Breaker
Typ e
1
HQP P 10–70 1 120/240 24, 48, 62.5 10a, 11a, 12a — 10,000 — 5000
HQP P 10–125 2 120/240 24, 48, 80 10a, 12a — 10,000 — 5000 5000 5000 V4-T1-6
1
HQP P 10–100 2, 3 240 — 10b, 11b, 12b — — 10,000 — — — V4-T1-6
QPHW P 15–70 1 120/240 24, 48, 62.5 14a — 22,000 — 5000
1
QPHW P 15–125 2 120/240 24, 48, 80 14a — 22,000 — 5000 5000 5000 V4-T1-6
1
QPHW P 15–100 2, 3 240 — 14b — — 22,000 — — — V4-T1-6
QHPX P 15–70 1 120/240 24, 48, 62.5 — — 42,000 — 5000
1
QHPX P 15–100 2 120/240 24, 48, 80 — — 42,000 — 5000 5000 5000 V4-T1-7
QHPX P 15–100 3 240 — — — — 42,000 — — — V4-T1-7
1
QHPW P 15–30 1 120/240 24, 48, 62.5 15a — 65,000 — 5000
1
QHPW P 15–30 2 120/240 24, 48, 80 15a — 65,000 — 5000 5000 5000 V4-T1-7
QHPW P 15–20 3 240 — 15b — — 65,000 — — — V4-T1-7
1
QPGFT P, GF 15–40 1 120 — 10a, 11a, 12a 10,000 — — — — — V4-T1-9
QPGFT P, GF 15–50 2 120/240 — 10a, 11a, 12a — 10,000 — — — — V4-T1-9
1
Notes
1
1
2
3
1
4
Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA.
1
For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-30 to V4-T1-35.
Circuit Breaker
Type Code
QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
Two-pole DC interrupting ratings based on two poles connected in series. Not UL® listed.
Breakers at DC ratings are not UL listed.
62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
Continuous
Ampere
Rating
at 40°C
Number
of
Poles Vac Vdc
Contents
Description
Quick Reference
Federal
Spec.
W-C-375b
Interrupting Ratings rms Symmetrical Amperes
Vac Ratings Vdc Ratings
120 120/240 240 24–48 62.5 80
23
4
— V4-T1-6
4
4
4
Page
Number
— V4-T1-6
— V4-T1-7
— V4-T1-7
1
1
1
1
V4-T1-2 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1.1
Eaton’s QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out, continued
Circuit
Breaker
Typ e
QPHGFT P, GF 15–30 1 120 — 10a, 11a, 12a 22,000 — — — — — V4-T1-9
QPHGFT P, GF 15–50 2 120/240 — 10a, 11a, 12a — 22,000 — — — — V4-T1-9
QPGFEP P, GFEP 15–40 1 120 — — 10,000 — — — — — V4-T1-9
QPGFEP P, GFEP 15–50 2 120/240 — — — 10,000 — — — — V4-T1-9
QPHGFEP P, GFEP 15–30 1 120 — — 22,000 — — — — — V4-T1-9
BABRSP B 15–30 1 120 — — 10,000 — — — — — V4-T1-12
BABRSP B 15–30 2 120/240 — — — 10,000 — — — — V4-T1-12
BRRP P 15–30 1 120 — — 10,000 — — — — — V4-T1-31
BRRP P 15–30 2 120/240 — — — 10,000 — — — — V4-T1-31
CLRP P 15–30 1 120 — — 10,000 — — — — — V4-T1-31
CLRP P 15–30 2 120/240 — — — 10,000 — — — — V4-T1-31
BAB B 10–70 1 120/240 24, 48, 62.5 10a, 11a, 12a — 10,000 — 5000
BAB B 10–125 2 120/240 24, 48, 80 10a, 12a — 10,000 — 5000 5000 5000 V4-T1-12
BAB B 10–100 2, 3 240 — 10b, 11b, 12b — — 10,000 — — — V4-T1-12
BABRP B 15–30 1 120 — — 10,000 — — — — — V4-T1-31
BABRP B 15–30 2 120/240 — — — 10,000 — — — — V4-T1-31
QBAF B, AF 15–20 1, 2 120/240 — — — 10,000 — — — — V4-T1-15
QBCAF B, AF, GF 15–20 1, 2 120/240 — — — 10,000 — — — — V4-T1-15
QBHW B 15–70 1 120/240 24, 48, 62.5 14a — 22,000 — 5000
QBHW B 15–125 2 120/240 24, 48, 80 14a — 22,000 — 5000 5000 5000 V4-T1-12
QBHW B 15–100 2, 3 240 — 14b — — 22,000 — — — V4-T1-12
HBAX B 15–70 1 120/240 24, 48, 62.5 — — 42,000 — 5000
HBAX B 15–100 2 120/240 24, 48, 80 — — 42,000 — 5000 5000 5000 V4-T1-13
HBAX B 15–100 3 240 — — — 42,000 — — — V4-T1-13
HBAW B 15–30 1 120/240 24, 48, 62.5 15a — 65,000 — 5000
HBAW B 15–30 2 120/240 24, 48, 80 15a — 65,000 — 5000 5000 5000 V4-T1-13
HBAW B 15–20 3 240 — 15b — — 65,000 — — — V4-T1-13
QBGFT B, GF 15–40 1 120 — 10a, 11a, 12a 10,000 — — — — — V4-T1-17
QBGFT B, GF 15–50 2 120/240 — 10a, 11a, 12a — 10,000 — — — — V4-T1-17
QBHGFT B, GF 15–30 1 120 — 10a, 11a, 12a 22,000 — — — — — V4-T1-17
QBHGFT B, GF 15–30 1 120/240 — 10a, 11a, 12a — 22,000 — — — — V4-T1-17
QBGFEP B, GFEP 15–40 1 120 — — 10,000 — — — — — V4-T1-17
QBGFEP B, GFEP 15–50 2 120/240 — — — 10,000 — — — — V4-T1-17
QBHGFEP B, GFEP 15–30 1 120 — — 22,000 — — — — — V4-T1-17
QBHGFEP B, GFEP 15–30 2 120/240 — — 22,000 22,000 — — — — V4-T1-17
QC C 10–70 1 120/240 24, 48, 62.5 10a, 11a, 12a — 10,000 — 5000
QC C 10–100 2 120/240 24, 48, 80 10a, 12a — 10,000 — 5000 5000 5000 V4-T1-40
QC C 10–100 2, 3, 4 240 — 10b, 11b, 12b — — 10,000 — — — V4-T1-40
QCD C 10–60 1, 2 120/240 24, 48, 62.5 — 10,000 10,000 — 3000 3000 — V4-T1-22
QCD C 10–100 2, 3 240 24, 48, 62.5 — — 10,000 — 3000 3000 — V4-T1-22
QCF C 10–60 1, 2 120/240 24, 48, 62.5 — 10,000 10,000 — 3000 3000 — V4-T1-41
Notes
1
2
3
4
Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA.
For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-30 to V4-T1-35.
Circuit Breaker
Type Code
QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed.
Breakers at DC ratings are not UL listed.
62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
Continuous
Ampere
Rating
at 40°C
Number
of
Poles Vac Vdc
Federal
Spec.
W-C-375b
Interrupting Ratings rms Symmetrical Amperes
Vac Ratings Vdc Ratings
120 120/240 240 24–48 62.5 80
23
4
4
4
4
4
Page
Number
— V4-T1-12
— V4-T1-12
— V4-T1-13
— V4-T1-13
— V4-T1-40
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-3
Miniature Circuit Breakers and Supplementary Protectors
1.1
Eaton’s QUICKLAG Industrial Circuit Breakers 1 Plug-In, Bolt-On, Cable-In/Cable-Out, continued
1
Circuit
Breaker
1
Typ e
QCF C 15–20 1, 2 120/240 24, 48, 62.5 — 22,000 — — 3000 3000 — V4-T1-26
1
QCF C 15–30 2, 3 240 24, 48, 62.5 — — 10,000 — 3000 3000 — V4-T1-26
1
QCR C 10–60 1, 2 120/240 24, 48, 62.5 — 10,000 10,000 — 3000 3000 — V4-T1-26
QCR C 15–20 1, 2 120/240 24, 48, 62.5 — 22,000 — — 3000 3000 — V4-T1-26
1
QCR C 15–30 2, 3 240 24, 48, 62.5 — — 10,000 — 3000 3000 — V4-T1-26
QCHW C 15–70 1 120/240 24, 48, 62.5 14a — 22,000 — 5000
1
QCHW C 15–100 2 120/240 24, 48, 80 14a — 22,000 — 5000 5000 5000 V4-T1-21
QCHW C 15–100 2, 3 240 — 14b — — 22,000 — — — V4-T1-21
1
QHCX C 15–70 1 120/240 24, 48, 62.5 — — 42,000 — 5000
1
QHCX C 15–100 2 120/240 24, 48, 80 — — 42,000 — 5000 5000 5000 V4-T1-21
QHCX C 15–100 3 240 — — — — 42,000 — — — V4-T1-21
1
QHCW C 15–30 1 120/240 24, 48, 62.5 15a — 65,000 — 5000
QHCW C 15–30 2 120/240 24, 48, 80 15a — 65,000 — 5000 5000 5000 V4-T1-21
1
QHCW C 15–20 3 240 — 15b — — 65,000 — — — V4-T1-21
1
QCGFT C, GF 15–40 1 120 — — 10,000 — — — — — V4-T1-28
QCGFT C, GF 15–50 2 120/240 — — — 10,000 — — — — V4-T1-28
1
QCHGFT C, GF 15–30 1 120 — — 22,000 — — — — — V4-T1-28
QCHGFT C, GF 15–30 2 120/240 — — — 22,000 — — — — V4-T1-28
1
QCGFEP C, GFEP 15–40 1 120 — — 10,000 — — — — — V4-T1-28
QCGFEP C, GFEP 15–50 2 120/240 — — — 10,000 — — — — V4-T1-28
1
QCHGFEP C, GFEP 15–30 1 120 — — 22,000 — — — — — V4-T1-28
1
QCHGFEP C, GFEP 15–30 2 120/240 — — — 22,000 — — — — V4-T1-28
Notes
1
1
QUICKLAG circuit breakers are suitable for application in relative humidity 0–95% noncondensing.
2
Two-pole DC interrupting ratings based on two poles connected in series. Not UL listed.
3
1
1
62.5 Vac interrupting rating is 3800 AIC 10–50A and 2500 AIC 55–100A continuous.
Circuit Breaker Type Codes: P Plug-In; B Bolt-On; C Cable-In/Cable-Out; GF Ground Fault, 5 mA; GFEP Ground Fault, 30 mA.
For Types GHBS, GBHS and BABRP solenoid-operated, remote-controlled circuit breakers, see Pages V4-T1-30 to V4-T1-35.
Circuit
Breaker
Type Code
Industrial Circuit Breakers
Continuous
Ampere
Rating
at 40°C
Number
of
Poles Vac Vdc
Federal
Spec.
W-C-375b
Interrupting Ratings rms Symmetrical Amperes
Vac Ratings Vdc Ratings
120 120/240 240 24–48 62.5 80
2
3
3
3
Page
Number
— V4-T1-21
— V4-T1-21
— V4-T1-21
1
1
1
1
1
1
1
1
1
1
1
1
V4-T1-4 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
QUICKLAG Type HQP Single-Pole
Industrial Circuit Breakers
1.1
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW
Product Description
●
All products 15–100A are
HACR rated
●
Switching duty rated for
120 Vac fluorescent light
applications
Standards and Certifications
●
Built and listed to UL 489
●
All products UL and
®
listed
CSA
Contents
Description Page
Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW
Product Selection. . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-7
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP . . . . .
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers. . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
V4-T1-6
V4-T1-8
V4-T1-14
V4-T1-16
V4-T1-19
V4-T1-23
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-5
1.1
QUICKLAG Type HQP
Single-Pole
Product Selection
1
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type: HQP 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
10 HQP1010 HQP2010 — HQP3010H
15 HQP1015
20 HQP1020
25 HQP1025 HQP2025 HQP2025H HQP3025H
30 HQP1030 HQP2030 HQP2030H HQP3030H
35 HQP1035 HQP2035 HQP2035H HQP3035H
40 HQP1040 HQP2040 HQP2040H HQP3040H
45 HQP1045 HQP2045 HQP2045H HQP3045H
50 HQP1050 HQP2050 HQP2050H HQP3050H
55 HQP1055 HQP2055 HQP2055H HQP3055H
60 HQP1060 HQP2060 HQP2060H HQP3060H
70 HQP1070 HQP2070 HQP2070H HQP3070H
80 — HQP2080 HQP2080H HQP3080H
90 — HQP2090 HQP2090H HQP3090H
100 HQP1100 HQP2100 HQP2100H HQP3100H
110 — HQP2110 — —
125 — HQP2125 — —
150 — HQP2150 — —
QUICKLAG Type: HQP Non-Automatic Switches
Continuous
Ampere Rating
at 40°C
50 HQP1050N — HQP2050N HQP3050N
60 HQP1060N — HQP2060N HQP3060N
100 HQP1100N — HQP2100N HQP3100N
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
12
12
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
HQP2015 HQP2015H HQP3015H
HQP2020 HQP2020H HQP3020H
3
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type: QPHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QPHW1015
20 QPHW1020
25 QPHW1025 QPHW2025 QPHW2025H QPHW3025H
30 QPHW1030 QPHW2030 QPHW2030H QPHW3030H
35 QPHW1035 QPHW2035 QPHW2035H QPHW3035H
40 QPHW1040 QPHW2040 QPHW2040H QPHW3040H
45 QPHW1045 QPHW2045 QPHW2045H QPHW3045H
50 QPHW1050 QPHW2050 QPHW2050H QPHW3050H
55 QPHW1055 QPHW2055 QPHW2055H QPHW3055H
60 QPHW1060 QPHW2060 QPHW2060H QPHW3060H
70 QPHW1070 QPHW2070 QPHW2070H QPHW3070H
80 — QPHW2080 QPHW2080H QPHW3080H
90 — QPHW2090 QPHW2090H QPHW3090H
100 — QPHW2100 QPHW2100H QPHW3100H
110 — QPHW2110 — —
125 — QPHW2125 — —
Notes
1
Switching duty rated for 120 Vac fluorescent light applications.
2
For special low-magnetic breaker, order HQP1015L1 or HQP1020L1.
3
Not UL listed.
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
1
QPHW2015 QPHW2015H QPHW3015H
QPHW2020 QPHW2020H QPHW3020H
V4-T1-6 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1.1
QUICKLAG Type: QHPX 42,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QHPX1015
20 QHPX1020
25 QHPX1025 QHPX2025 — QHPX3025H
30 QHPX1030 QHPX2030 — QHPX3030H
35 QHPX1035 QHPX2035 — QHPX3035H
40 QHPX1040 QHPX2040 — QHPX3040H
45 QHPX1045 QHPX2045 — QHPX3045H
50 QHPX1050 QHPX2050 — QHPX3050H
55 QHPX1055 QHPX2055 — QHPX3055H
60 QHPX1060 QHPX2060 — QHPX3060H
70 QHPX1070 QHPX2070 — QHPX3070H
80 — QHPX2080 — QHPX3080H
90 — QHPX2090 — QHPX3090H
100 — QHPX2100 — QHPX3100H
QUICKLAG Type: QHPW 65,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QHPW1015
20 QHPW1020
25 Q H P W 1 0 2 5Q H P W 2 0 2 5— —
30 Q H P W 1 0 3 0Q H P W 2 0 3 0— —
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
1
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
1
QHPX2015 — QHPX3015H
QHPX2020 — QHPX3020H
QHPW2015 — QHPW3015H
QHPW2020 — QHPW3020H
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Dimensions
Approximate Dimensions in Inches (mm)
Shipping Data
Number
of Poles
1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
Note
1
Switching duty rated for 120 Vac fluorescent light applications.
Carton
Quantity
Approximate
Weight Lbs (kg) Dimensions
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-7
1
1.1
QUICKLAG Type QPGFT Single-Pole
Ground Fault Circuit Breaker
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Plug-On Ground Fault and Equipment
1
Protectors, Types QPGFT, QPHGFT, QPGFEP, QPHGFEP
1
Product Description
1
QUICKLAG Ground Fault Circuit
Breakers, Class A GFCI
●
1
1
1
5 mA trip sensitivity
QUICKLAG Ground Fault
Equipment Protectors
●
30 mA trip sensitivity
Standards and Certifications
●
Built and listed to UL 489
QUICKLAG Ground Fault Circuit
Breakers, Class A GFCI
●
Built and tested to UL 943
QUICKLAG Ground Fault
Equipment Protectors
●
Built and listed to UL 1053
1
Contents
Description Page
Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-10
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers . . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
V4-T1-9
V4-T1-14
V4-T1-16
V4-T1-19
V4-T1-23
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
V4-T1-8 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
QUICKLAG Type QPGFT
Single-Pole
Industrial Circuit Breakers
1.1
Product Selection
Ground Fault Circuit Breakers—5 mA Sensitivity QUICKLAG Type:
QPGFT 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QPGFT1015 QPGFT2015
20 QPGFT1020 QPGFT2020
25 QPGFT1025 QPGFT2025
30 QPGFT1030 QPGFT2030
40 QPGFT1040 QPGFT2040
50 — QPGFT2050
Ground Fault Circuit Breakers—5 mA Sensitivity QUICKLAG Type:
QPHGF 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QPHGF1015 QPHGF2015
20 QPHGF1020 QPHGF2020
25 QPHGF1025 QPHGF2025
30 QPHGF1030 QPHGF2030
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Ground Fault Equipment Breakers—30 mA Sensitivity QUICKLAG Type:
QPGFEP 10,000 Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QPGFEP1015 QPGFEP2015
20 QPGFEP1020 QPGFEP2020
25 QPGFEP1025 QPGFEP2025
30 QPGFEP1030 QPGFEP2030
40 QPGFEP1040 QPGFEP2040
50 — QPGFEP2050
Ground Fault Equipment Breakers—30 mA Sensitivity QUICKLAG Type:
QPHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QPHGFEP1015 QPHGFEP2015
20 QPHGFEP1020 QPHGFEP2020
25 QPHGFEP1025 QPHGFEP2025
30 QPHGFEP1030 QPHGFEP2030
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-9
1
1
Miniature Circuit Breakers and Supplementary Protectors
Blue Wire
Red Wire
Black Wire
Ground
Fault
Breaker
Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac.
Bell Alarm (W1)—contacts change state when breaker trips.
Auxiliary Switch (W2)—contacts change state when breaker is opened (or tripped) or closed.
14-inch (355.6 mm) long 18 AWG pigtail wire leads provided.
Blue
Red
NC
NO
1.1
Special Application Ground Fault Circuit Protectors—5 mA Sensitivity
1
QUICKLAG Type: QPGFT 10,000A Interrupting Capacity with Bell Alarm (W1) or
Auxiliary Switch (W2)
1
Continuous
Ampere Rating
1
at 40°C
15 QPGFT1015W1 QPGFT2015W1
1
20 QPGFT1020W1 QPGFT2020W1
25 QPGFT1025W1 QPGFT2025W1
1
30 QPGFT1030W1 QPGFT2030W1
40 — QPGFT2040W1
1
50 — QPGFT2050W1
15 QPGFT1015W2 —
1
20 QPGFT1020W2 —
25 QPGFT1025W2 —
1
30 QPGFT1030W2 —
1
Special Application Ground Fault Circuit Protectors—30 mA Sensitivity
QUICKLAG Type: QPGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or
1
Auxiliary Switch (W2)
1
Continuous
Ampere Rating
at 40°C
1
15 QPGFEP1015W1 QPGFEP2 015W1
1
20 QPGFEP1020W1 QPGFEP2 020W1
25 QPGFEP1025W1 QPGFEP2 025W1
1
30 QPGFEP1030W1 QPGFEP2 030W1
40
1
50
15 QPGFEP1015W2 —
1
20 QPGFEP1020W2 —
25 QPGFEP1025W2 —
1
30 QPGFEP1030W2 —
1
Industrial Circuit Breakers
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
—
—
QPGFEP2040W1
QPGFEP2050W1
Wiring Diagram
1
Bell Alarm and Auxiliary Contact Schematic
1
1
1
1
1
1
Dimensions
Approximate Dimensions in Inches (mm)
1
Shipping Data
1
Number
of Poles
1
1 24 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)
2 5 5.00 (2.3) 15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3)
1
Note
Shipped individually or in carton quantities.
1
V4-T1-10 Volume 4—Circuit Protection CA08100005E—April 2019
Carton
Quantity
Approximate
Weight Lbs (kg) Dimensions
Miniature Circuit Breakers and Supplementary Protectors
QUICKLAG Type BAB Single-Pole
Industrial Circuit Breakers
1.1
Bolt-On Types BAB, QBHW, HBAX, HBAW
Product Description
●
All products 15–100A are
HACR rated
●
Switching duty rated
for 120 Vac fluorescent
light applications
Standards and Certifications
●
Built and listed to UL 489
●
All products UL and
CSA listed
Contents
Description Page
Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP . . . . .
Bolt-On Types BAB, QBHW, HBAX, HBAW
Product Selection. . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-13
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers. . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
V4-T1-8
V4-T1-12
V4-T1-14
V4-T1-16
V4-T1-19
V4-T1-23
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-11
1.1
QUICKLAG Type BAB
Single-Pole
Product Selection
1
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type: BA 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
10 BAB1010 BAB2010 BAB2010H
15 BAB1015
20 BAB1020
25 BAB1025 BAB2025 BAB2025H BAB3025H
30 BAB1030 BAB2030 BAB2030H BAB3030H
35 BAB1035 BAB2035 BAB2035H BAB3035H
40 BAB1040 BAB2040 BAB2040H BAB3040H
45 BAB1045 BAB2045 BAB2045H BAB3045H
50 BAB1050 BAB2050 BAB2050H BAB3050H
55 BAB1055 BAB2055 BAB2055H BAB3055H
60 BAB1060 BAB2060 BAB2060H BAB3060H
70 BAB1070 BAB2070 BAB2070H BAB3070H
80 — BAB2080 BAB2080H BAB3080H
90 — BAB2090 BAB2090H BAB3090H
100 BAB1100 BAB2100 BAB2100H BAB3100H
110 — BAB2110 — —
125 — BAB2125 — —
QUICKLAG Type: BA Non-Automatic Switches
Continuous
Ampere Rating
at 40°C
50 BAB1050N — BAB2050N BAB3050N
60 BAB1060N — BAB2060N BAB3060N
100 BAB1100N — BAB2100N BAB3100N
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
3
12
12
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
BAB2015 BAB2015H BAB3015H
BAB2020 BAB2020H BAB3020H
BAB3010H
3
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type: QBHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QBHW1015
20 QBHW1020
25 QBHW1025 QBHW2025 QBHW2025H QBHW3025H
30 QBHW1030 QBHW2030 QBHW2030H QBHW3030H
35 QBHW1035 QBHW2035 QBHW2035H QBHW3035H
40 QBHW1040 QBHW2040 QBHW2040H QBHW3040H
45 QBHW1045 QBHW2045 QBHW2045H QBHW3045H
50 QBHW1050 QBHW2050 QBHW2050H QBHW3050H
55 QBHW1055 QBHW2055 QBHW2055H QBHW3055H
60 QBHW1060 QBHW2060 QBHW2060H QBHW3060H
70 QBHW1070 QBHW2070 QBHW2070H QBHW3070H
80 — QBHW2080 QBHW2080H QBHW3080H
90 — QBHW2090 QBHW2090H QBHW3090H
100 — QBHW2100 QBHW2100H QBHW3100H
110 — QBHW2110 — —
125 — QBHW2125 — —
Notes
1
Switching duty rated for 120 Vac fluorescent light applications.
2
For special low-magnetic breaker, order BAB1015L1 or BAB1020L1.
3
Not UL listed.
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
1
QBHW2015 QBHW2015H QBHW3015H
QBHW2020 QBHW2020H QBHW3020H
V4-T1-12 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1.1
QUICKLAG Type: HBAX 42,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 HBAX1015
20 HBAX1020
25 HBAX1025 HBAX2025 — HBAX3025H
30 HBAX1030 HBAX2030 — HBAX3030H
35 HBAX1035 HBAX2035 — HBAX3035H
40 HBAX1040 HBAX2040 — HBAX3040H
45 HBAX1045 HBAX2045 — HBAX3045H
50 HBAX1050 HBAX2050 — HBAX3050H
55 HBAX1055 HBAX2055 — HBAX3055H
60 HBAX1060 HBAX2060 — HBAX3060H
70 HBAX1070 HBAX2070 — HBAX3070H
80 — HBAX2080 — HBAX3080H
80 — HBAX2080 — HBAX3080H
90 — HBAX2090 — HBAX3090H
100 — HBAX2100 — HBAX3100H
QUICKLAG Type: HBAW 65,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 HBAW1015
20 HBAW1020
25 HBAW1025 HBAW2025 — —
30 HBAW1030 HBAW2030 — —
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
1
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
1
HBAX2015 — HBAX3015H
HBAX2020 — HBAX3020H
HBAW2015 — HBAW3015H
HBAW2020 — HBAW3020H
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Dimensions
Approximate Dimensions in Inches (mm)
Shipping Data
Number
of Poles
1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
Note
1
Switching duty rated for 120 Vac fluorescent light applications.
Carton
Quantity
Approximate
Weight Lbs (kg) Dimensions
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-13
1.1
Bolt-On Arc Fault Circuit Interrupter QUICKLAG Types QBAF, QBCAF
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
Bolt-On Arc Fault Circuit Interrupter Types QBAF, QBCAF
1
Product Description
1
●
All products HACR rated
1
1
1
Features, Benefits and
Functions
●
10 and 22 kAIC rating at
120V and 120/240V
●
Single-pole AFCI
●
HID ratings for HID (High
Intensity Discharge) lighting
●
All models are HACR rated
1
Contents
Description Page
Quick Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP . . . . .
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-15
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers . . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
Standards and Certifications
●
Built and listed to UL 489
●
UL File E7819 for QBAF
V4-T1-8
V4-T1-15
V4-T1-16
V4-T1-19
V4-T1-23
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
1
V4-T1-14 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
NAB
120/240 Vac
Source
120V
Duplex
Receptacle
Single-Pole
Line B
Neutral
Neutral
Equipment Ground
Industrial Circuit Breakers
1.1
Product Selection
QBCAF and QBAF Type AFCIs
Effective immediately, Eaton
AFCIs are available for use in
Sumter panels with a 22 kAIC
rating. This higher rated
breaker will allow us to
win jobs where AFCIs are
specified at higher than
10 kAIC. This breaker
provides standard thermal-
1-Inch (25.4 mm) Wide Bolt-On Arc Fault Circuit Interrupter
Poles
Type QBCAF Combination AFCI
Single-pole 10 kAIC 15 Combination AFCI QB1015CAF
Wiring Diagrams
Single-Pole 120V Load Application Single-Pole Shared Neutral with
Sourced by 120/240 Vac Multi-Duplex Receptacle Application
magnetic protection of
branch circuits. This product
will have the same form, fit
and function of the current
bolt-on AFCI (QBCAF and
QBAF Type). Product scope is
below. These breakers are in
Bid Manager™ for Pow-RLine 1a, Pow-R-Line 1a-LX,
kAIC
Rating
22 kAIC 15 Combination AFCI QBH1015CAF
Ampere
Rating Configuration Catalog Number
20 Combination AFCI QB1020CAF
20 Combination AFCI QBH1020CAF
Pow-R-Line 3a and Pow-RLine 4a panelboards. For
series rated combinations,
continue to use the less
expensive 10 kAIC QBCAF
and QBAF offerings.
Breakers can also be ordered
from Vista.
120/240 Vac
Source
NA B
Line B
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Neutral
Two-Pole
Neutral
Two 120V
Duplex
Receptacles
1
1
1
Line A
Equipment Ground
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-15
1
1.1
QUICKLAG Type QBGFT Single-Pole
Ground Fault Circuit Breaker
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
Bolt-On Ground Fault and Equipment Protectors,
1
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP
1
Product Description
1
QUICKLAG Ground Fault Circuit
Breakers, Class A GFCI
●
1
1
1
5 mA trip sensitivity
QUICKLAG Ground Fault
Equipment
Protectors
●
30 mA trip sensitivity
Standards and Certifications
●
Built and tested to UL 489
QUICKLAG Ground Fault Circuit
Breakers, Class A GFCI
●
Built and tested to UL 943
QUICKLAG Ground Fault
Equipment Protectors
●
Built and tested to UL 1053
1
Contents
Description Page
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP . . . . .
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-18
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-18
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers . . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
V4-T1-8
V4-T1-14
V4-T1-17
V4-T1-19
V4-T1-23
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
V4-T1-16 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
QUICKLAG Type QBGFT
Single-Pole
Industrial Circuit Breakers
1.1
Product Selection
Ground Fault Circuit Breakers—5 mA Sensitivity QUICKLAG Type:
QBGFT 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QB1015GF QBGFT2015
20 QB1020GF QBGFT2020
25 QB1025GF QBGFT2025
30 QB1030GF QBGFT2030
40 QB1040GF QBGFT2040
50 — QBGFT2050
Ground Fault Circuit Breakers—5 mA Sensitivity QUICKLAG Type:
QBHGFT 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QBH1015GF QBHGF2015
20 QBH1020GF QBHGF2020
25 QBH1025GF QBHGF2025
30 QBH1030GF QBHGF2030
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Ground Fault Equipment Breakers—30 mA Sensitivity QUICKLAG Type:
QBGFEP 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QB1015EP QBGFEP2015
20 QB1020EP QBGFEP2020
25 QB1025EP QBGFEP2025
30 QB1030EP QBGFEP2030
40 QB1040EP QBGFEP2040
50 — QBGFEP2050
Ground Fault Equipment Breakers—30 mA Sensitivity QUICKLAG Type:
QBHGFEP 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QBH1015EP QBHGFEP2015
20 QBH1020EP QBHGFEP2020
25 QBH1025EP QBHGFEP2025
30 QBH1030EP QBHGFEP2030
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-17
1
1
Miniature Circuit Breakers and Supplementary Protectors
Blue Wire
Red Wire
Black Wire
Ground
Fault
Breaker
Single-throw double-pole contacts are UL and CSA listed for 5A at 250 Vac.
Bell Alarm (W1)—contacts change state when breaker trips.
Auxiliary Switch (W2)—contacts change state when breaker is opened (or tripped) or closed.
14-inch (355.6 mm) long 18 AWG pigtail wire leads provided.
Blue
Red
NC
NO
1.1
Special Application Ground Fault Circuit Protectors—5 mA Sensitivity QUICKLAG Type:
1
QBGFT 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2)
Continuous
1
Ampere Rating
at 40°C
1
15 QBGFT1015W1 QBGFT2015W1
20 QBGFT1020W1 QBGFT2020W1
1
25 QBGFT1025W1 QBGFT2025W1
30 QBGFT1030W1 QBGFT2030W1
1
40 — QBGFT2040W1
50 — QBGFT2050W1
1
15 QBGFT1015W2 —
20 QBGFT1020W2 —
1
25 QBGFT1025W2 —
30 QBGFT1030W2 —
1
1
Special Application Ground Fault Circuit Protectors—30 mA Sensitivity QUICKLAG Type:
QBGFEP 10,000A Interrupting Capacity with Bell Alarm (W1) or Auxiliary Switch (W2)
1
Continuous
Ampere Rating
1
at 40°C
15 QBGFEP1015W1 QBGFEP2015W1
1
20 QBGFEP1020W1 QBGFEP2020W1
25 QBGFEP1025W1 QBGFEP2025W1
1
30 QBGFEP1030W1 QBGFEP2030W1
1
40 — QBGFEP2040W1
50 — QBGFEP2050W1
1
15 QBGFEP1015W2 —
20 QBGFEP1020W2 —
1
25 QBGFEP1025W2 —
30 QBGFEP1030W2 —
1
Industrial Circuit Breakers
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
Single-Pole Two-Pole
120 Vac 120/240 Vac
Catalog Number Catalog Number
1
Wiring Diagram
Bell Alarm and Auxiliary Contact Schematic
1
1
1
1
1
1
Dimensions
1
Approximate Dimensions in Inches (mm)
Shipping Data
1
Number of Poles Approximate Weight Lbs (kg) Dimensions
1
1 11.00 (5.0) 12.50 x 6.50 x 5.00 (317.5 x 165.1 x 127.0)
2 5.00 (2.3) 15.50 x 6.00 x 4.50 (393.7 x 152.4 x 114.3)
1
Note
Shipped individually or in carton quantities.
1
1
V4-T1-18 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
QUICKLAG Type QC Single-Pole
Industrial Circuit Breakers
1.1
Cable-In/Cable-Out Types QC, QCD, QCHW, QHCX, QHCW
Product Description
●
All products 10–100A are
HACR rated
●
Switching duty rated for
120 Vac fluorescent light
applications only
Standards and Certifications
●
Built and listed to UL 489
●
All products UL and
CSA listed
Contents
Description Page
Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP . . . . .
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt-On Ground Fault and Equipment Protectors,
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW
Product Selection. . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-22
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers. . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
V4-T1-8
V4-T1-14
V4-T1-16
V4-T1-20
V4-T1-23
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-19
1.1
QUICKLAG
Type QC Single-Pole
Product Selection
1
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type: QC 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
5 QC1005
10 QC1010 QC2010 QC2010H
15 QC1015
20 QC1020
25 QC1025 QC2025 QC2025H QC3025H QC4025H
30 QC1030 QC2030 QC2030H QC3030H QC4030H
35 QC1035 QC2035 QC2035H QC3035H QC4035H
40 QC1040 QC2040 QC2040H QC3040H QC4040H
45 QC1045 QC2045 QC2045H QC3045H QC4045H
50 QC1050 QC2050 QC2050H QC3050H QC4050H
55 QC1055 QC2055 QC2055H QC3055H QC4055H
60 QC1060 QC2060 QC2060H QC3060H QC4060H
70 QC1070 QC2070 QC2070H QC3070H QC4070H
70 — QC2080 QC2080H QC3080H QC4080H
90 — QC2090 QC2090H QC3090H QC4090H
100 QC1100 QC2100 QC2100H QC3100H QC4100H
QUICKLAG Type: QC Non-Automatic Switches
Continuous
Ampere Rating
at 40°C
50 QC1050N — QC2050N QC3050N —
60 QC1060N — QC2060N QC3060N —
100 QC1100N — QC2100N QC3100N —
Notes
1
Not UL listed.
2
Switching duty rated for 120 Vac fluorescent light applications only.
For special low-magnetic breaker, order QC1015L1 or QC1020L1 .Non-automatic switches, see Page V4-T1-41.
Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
1
2
2
Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
1
QC2005
QC2015 QC2015H QC3015H QC4015H
QC2020 QC2020H QC3020H QC4020H
———
1
QC3010H
1
—
1
1
1
1
1
1
1
1
1
1
V4-T1-20 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1.1
QUICKLAG Type: QCHW 22,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QCHW1015
20 QCHW1020
25 QCHW1025 QCHW2025 QCHW2025H QCHW3025H QCHW4025H
30 QCHW1030 QCHW2030 QCHW2030H QCHW3030H QCHW4030H
35 QCHW1035 QCHW2035 QCHW2035H QCHW3035H QCHW4035H
40 QCHW1040 QCHW2040 QCHW2040H QCHW3040H QCHW4040H
45 QCHW1045 QCHW2045 QCHW2045H QCHW3045H QCHW4045H
50 QCHW1050 QCHW2050 QCHW2050H QCHW3050H QCHW4050H
55 QCHW1055 QCHW2055 QCHW2055H QCHW3055H QCHW4055H
60 QCHW1060 QCHW2060 QCHW2060H QCHW3060H QCHW4060H
70 QCHW1070 QCHW2070 QCHW2070H QCHW3070H QCHW4070H
70 — QCHW2080 QCHW2080H QCHW3080H QCHW4080H
90 — QCHW2090 QCHW2090H QCHW3090H QCHW4090H
100 — QCHW2100 QCHW2100H QCHW3100H QCHW4100H
QUICKLAG Type: QHCX 42,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QHCX1015
20 QHCX1020
25 QHCX1025 QHCX2025 — QHCX3025H —
30 QHCX1030 QHCX2030 — QHCX3030H —
35 QHCX1035 QHCX2035 — QHCX3035H —
40 QHCX1040 QHCX2040 — QHCX3040H —
45 QHCX1045 QHCX2045 — QHCX3045H —
50 QHCX1050 QHCX2050 — QHCX3050H —
55 QHCX1055 QHCX2055 — QHCX3055H —
60 QHCX1060 QHCX2060 — QHCX3060H —
70 QHCX1070 QHCX2070 — QHCX3070H —
70 — QHCX2080 — QHCX3080H —
90 — QHCX2090 — QHCX3090H —
100 — QHCX2100 — QHCX3100H —
Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
1
1
Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
1
1
QCHW2015 QCHW2015H QCHW3015H QCHW4015H
QCHW2020 QCHW2020H QCHW3020H QCHW4020H
QHCX2015 — QHCX3015H —
QHCX2020 — QHCX3020H —
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type: QHCW 65,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
15 QHCW1015
20 QHCW1020
25 QHCW1025 QHCW2025 — — —
30 QHCW1030 QHCW2030 — — —
Notes
1
Switching duty rated for 120 Vac fluorescent light applications only.
Non-automatic switches, see Page V4-T1-41.
Single-Pole Two-Pole Two-Pole Three-Pole Four-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number
1
1
QHCW2015 — QHCW3015H —
QHCW2020 — QHCW3020H —
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-21
1
1
1
1
1
1
1
1
Miniature Circuit Breakers and Supplementary Protectors
QUICKLAG Type QCD
Miniature Circuit
Breaker
1.1
QUICKLAG Type QCD Miniature Circuit Breakers
1
QCD breakers are used
primarily in HVAC and
industrial applications.
1
●
1
1
1
1
Single-, two- and
three-pole options
●
Modular construction
●
DIN mounted
(symmetrical rail 35 x
7.5 DIN/EN 50 022)
●
QCD same profile as
Type QCR
Industrial Circuit Breakers
●
Flexible power feed
connection:
wire size, position
●
Same breaker size for
entire rating range
●
Field mountable
accessories:
finger shroud proof, quick
connect terminals
●
Other accessories:
jumper unit
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
QUICKLAG Type QCD 10,000A Interrupting Capacity Thermal-Magnetic Breakers
Continuous
Ampere Rating
at 40°C
10 QCD1010 QCD2010 — —
15 QCD1015 QCD2015 QCD2015H QCD3015H
20 QCD1020 QCD2020 QCD2020H QCD3020H
25 QCD1025 QCD2025 QCD2025H QCD3025H
30 QCD1030 QCD2030 QCD2030H QCD3030H
35 QCD1035 QCD2035 QCD2035H QCD3035H
40 QCD1040 QCD2040 QCD2040H QCD3040H
45 QCD1045 QCD2045 QCD2045H QCD3045H
50 QCD1050 QCD2050 QCD2050H QCD3050H
55 QCD1055 QCD2055 QCD2055H QCD3055H
60 QCD1060 QCD2060 QCD2060H QCD3060H
70 — QCD2070 QCD2070H QCD3070H
80 — QCD2080 QCD2080H QCD3080H
90 — QCD2090 QCD2090H QCD3090H
100 — QCD2090 QCD2090H QCD3100H
QUICKLAG Type QCD Non-Automatic Switches
Continuous
Ampere Rating
at 40°C
60 — — QCD2060NA —
100 ————
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
— QCD2100 QCD2100H —
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
1
Dimensions
Approximate Dimensions in Inches (mm)
1
Shipping Data
1
Number
of Poles
1
1 24 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
2 12 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
1
3 8 9.00 (4.1) 12.50 x 7.50 x 5.00 (317.5 x 190.5 x 127.0)
1
1
V4-T1-22 Volume 4—Circuit Protection CA08100005E—April 2019
Carton
Quantity
Approximate
Weight Lbs (kg) Dimensions
Miniature Circuit Breakers and Supplementary Protectors
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH
Industrial Circuit Breakers
1.1
Contents
Description Page
Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V4-T1-2
QUICKLAG Plug-On Types HQP, QPHW, QHPX, QHPW V4-T1-5
QUICKLAG Plug-On Ground Fault and Equipment Protectors,
Types QPGFT, QPHGFT, QPGFEP, QPHGFEP . . . . .
Bolt-On Types BAB, QBHW, HBAX, HBAW . . . . . . . . V4-T1-11
Bolt-On Arc Fault Circuit Interrupter Types
QBAF, QBCAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bolt-On Ground Fault and Equipment Protectors,
Single-Pole Two-Pole Single-Pole Two-Pole
QCR (Rear-Mounted Breakers) QCF (Front-Mounted Breakers)
Types QBGFT, QBHGFT, QBGFEP, QBHGFEP . . . . .
Cable-In/Cable-Out Types QC, QCD, QCHW,
QHCX, QHCW . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF,
QCRH, QCFH
Cable-In/Cable-Out Ground Fault and Equipment Protectors,
Types QCGFT, QCHGFT, QCGFEP, QCHGFEP . . . . .
Solenoid-Operated, Remote-Controlled Latching
Types BABRP, BABRSP, BRRP and CLRP. . . . . . . . .
Solenoid Operator—Remote Controlled Latching for
Type GHBS, GBHS and GHQRSP Breakers. . . . . . .
International Rated Types HQP, BA, QC, GFMB, GFXBC V4-T1-36
Special Application Breakers, Types HQP, BA, QC . . . V4-T1-39
Cable-In/Cable-Out, 1/2-Inch Wide, Types QCR, QCF, QCRH, QCFH
Product Description
Eaton Type QCR circuit
breakers have as a standard
feature provisions for 35 mm
DIN rail rear mounting with
a spring-loaded release.
Optional clips for individual
mounting are available as a
separate accessory.
Type QCF have two threaded
steel inserts to facilitate front
mounting with #6–32 steel
screws. The clamp type
terminals are accessible from
the rear of the breaker so that
cables can be accessed
without removal of the
breaker from the front cover.
Application Description
QCR and QCF circuit breakers
are only 1/2-inch (12.7 mm)
wide per pole and are
excellent for general purpose
industrial applications where
space savings is required.
Features, Benefits
and Functions
●
1/2-inch (12.7 mm) wide
per pole
●
Cable-in/cable-out
●
Black cases with black
handles
●
Three position handle:
ON, Tripped (center), OFF
●
Thermal-magnetic
protection
V4-T1-8
V4-T1-14
V4-T1-16
V4-T1-19
Product Selection. . . . . . . . . . . . . . . . . . . . . . . .
QCR and QCF Options and Accessories . . . . . . V4-T1-26
Standards and Certifications
●
Built and listed to UL 489
●
UL File No. E7819
●
CSA File No. LR48907
●
Type QCR and QCF circuit
breakers are UL listed
circuit breakers that are
suitable for use as branch
circuit protectors
●
All ratings 15–60A are
HACR rated
V4-T1-24
V4-T1-27
V4-T1-30
V4-T1-33
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-23
1.1
Cable-In/Cable-Out,
1/2-Inch Wide
Product Selection
1
Miniature Circuit Breakers and Supplementary Protectors
Industrial Circuit Breakers
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
QCR Breaker Catalog Numbers
Continuous
Ampere Rating
at 40°C
QCR Breaker 10 kAIC Interrupting Ratings
10 QCR1010 QCR2010 — —
15 QCR1015
20 QCR1020
25 QCR1025 QCR2025 QCR2025H QCR3025H
30 QCR1030 QCR2030 QCR2030H QCR3030H
35 QCR1035 QCR2035 — —
40 QCR1040 QCR2040 — —
45 QCR1045 QCR2045 — —
50 QCR1050 QCR2050 — —
55 QCR1055 QCR2055 — —
7
60
QCR Breaker 22 kAIC Interrupting Ratings
15 QCRH1015
20 QCRH1020
Notes
1
Standard breaker terminals are box type lugs.
2
Breakers with T Catalog Number Suffix are suitable for line and load side ring terminal connection
(#10–32 plus/minus terminal screw provided).
3
Breakers with P Catalog Number Suffix are suitable for terminating two 10 AWG Quick-Connect Type Terminals per
phase on breaker load side.
4
Breakers with Shunt Trip (extra pole required on breaker right-hand side) are available on single-, two- and three-pole.
Contact the Customer Support Center at 1-800-356-1243.
5
Breakers with H Catalog Suffix have 240 Vac construction.
6
All 15 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications.
7
60/75°C Cu/Al wire on all ratings except 60A, which requires Cu only conductor.
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
QCR1010T QCR2010T — —
— QCR2010P — —
6
6
QCR1015T
— QCR2015P — —
6
6
QCR1020T
— QCR2020P — —
QCR1025T QCR2025T QCR2025HT QCR3025HT
— QCR2025P — —
QCR1030T QCR2030T QCR2030HT QCR3030HT
— QCR2030P — —
— QCR2035P — —
— QCR2040P — —
— QCR2045P — —
— QCR2050P — —
— QCR2055P — —
QCR1060 QCR2060 — —
— QCR2060P — —
6
QCRH1015T
6
QCRH1020T
1234
5
QCR2015 QCR2015H QCR3015H
QCR2015T QCR2015HT QCR3015HT
QCR2020 QCR2020H QCR3020H
QCR2020T QCR2020HT QCR3020HT
QCRH2015 — —
6
6
QCRH2015T — —
QCRH2020 — —
QCRH2020T — —
1
1
V4-T1-24 Volume 4—Circuit Protection CA08100005E—April 2019
Miniature Circuit Breakers and Supplementary Protectors
Cable-In/Cable-Out,
1/2-Inch Wide
Industrial Circuit Breakers
1.1
QCF Breaker Catalog Numbers
Continuous
Ampere Rating
at 40°C
QCF Breaker 10 kAIC Interrupting Ratings
10 QCF1010 QCF2010 — —
15 QCF1015
20 QCF1020
25 QCF1025 QCF2025 QCF2025H QCF3025H
30 QCF1030 QCF2030 QCF2030H QCF3030H
35 QCF1035 QCF2035 — —
40 QCF1040 QCF2040 — —
45 QCF1045 QCF2045 — —
50 QCF1050 QCF2050 — —
55 QCF1055 QCF2055 — —
6
60
QCF Breaker 22 kAIC Interrupting Ratings
15 QCFH1015
20 QCFH1020
Notes
1
Standard breaker terminals are box type lugs.
2
Breakers with T Catalog Number Suffix are suitable for line and load side ring terminal connection
(#10–32 plus/minus terminal screw provided).
3
Breakers with Shunt Trip Attachment (extra pole required on breaker right-hand side) are available.
Contact the Customer Support Center.
4
Breakers with H Catalog Suffix have 240 Vac construction.
5
All 15 and 20A single-pole breakers are SWD (Switching Duty) rated for fluorescent lighting applications.
6
60/75°C Cu/Al wire on all ratings except 60A, which requires Cu only conductor.
Single-Pole Two-Pole Two-Pole Three-Pole
120/240 Vac 120/240 Vac 240 Vac
Catalog Number Catalog Number Catalog Number Catalog Number
QCF1010T QCF2010T — —
5
5
QCF1015T
5
5
QCF1020T
QCF1025T QCF2025T QCF2025HT QCF3025HT
QCF1030T QCF2030T QCF2030HT QCF3030HT
QCF1060 QCF2060 — —
5
QCFH1015T
5
QCFH1020T
123
4
QCF2015 QCF2015H QCF3015H
QCF2015T QCF2015HT QCF3015HT
QCF2020 QCF2020H QCF3020H
QCF2020T QCF2020HT QCF3020HT
QCFH2015 — —
5
5
QCFH2015T — —
QCFH2020 — —
QCFH2020T — —
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 4—Circuit Protection CA08100005E—April 2019 V4-T1-25