DATASHEET - PSG60N24RP
Power supply unit, 1-phase, 100-240VAC/24VDC, 2.5A
Part no. PSG60N24RP
Catalog No. 172890
Alternate Catalog
PSG60N24RP
No.
EL-Nummer
4560888
(Norway)
Delivery program
Product range Power supplies PSG
Subrange power supply unit
Description Power Boost via 1.5-fold rated operational current for 5 s
Phases Single-phase
Input voltage range 85 - 264 V AC
Nominal input voltage 100 - 240 V AC
Rated output voltage 24 V DC (± 2%)
Rated output current A 2.5
Setting range for the output voltage 22 - 28 V DC
Rated output power W 60
PELV (EN 60204), SELV (EN 60950)
(120 - 375 V DC)
Technical data
Input characteristics
Nominal input voltage 100 - 240 V AC
Input voltage range V 85 - 264 V AC
Supply frequency
Rated value Hz 50/60
Range Hz 47 - 63
Nominal current I
Inrush current limitation I²t (+25 °C) A < 40 A at 115 V AC
Mains buffering at nominal load ms
Mains failure bridging ms > 20 at 115 V AC
Run-up time after mains voltage applied ms < 3000
Internal input fuse (device protection, not accessible) T3.15 AH/250 V
Back-up fuse 6, 10, 16 A (recommended)
Tripping characteristic B
Leakage Current < 1 mA at 240 V AC
Short-term interruption 100% voltage dip, 1 cycle (20 ms at 50 Hz), automatic start
n
Output characteristics
Rated output power W 60
Rated output voltage 24 V DC (± 2%)
Tolerance ±2 %
Setting range for the output voltage 22 - 28 V DC
Nominal current A 2,5
Derating from T
Capacitive load starting Max 8000 µF
Heat dissipation W 9
Efficiency % > 86 with 115 V AC
Residual ripple and switching peaks < 50 mVpp / < 150 mVpp
> +50 °C > 50 °C (2.5% / °C)
amb
120 - 375 V DC
A 1.5 bei 100 V AC
< 80 A at 230 V AC
> 125 at 230 V AC
> 70 °C (4% / °C),
> 87 with 230 V AC
08/30/2019 Eaton 172890 ED2019 V58.0 EN 1 / 4
General characteristics
Housing Insulated material
Status indication green LED for "DC OK"
MTBF (mean time between failures) > 800,000 h
Height mm 120.6
Width mm 32
Depth mm 119.3
Weight kg 0.33
Terminations Screw connection
Stripping length mm 7
Terminal capacity
flexible with ferrules/solid
Tightening torque Nm 0.5
Ambient air temperature range °C
Operation °C -20 - +80 (> 50 °C derating)
Storage, transport ϑ °C
Storage ϑ °C -25 - +85
damp heat < 95 % relative humidity at +25 °C, no condensation
Vibrations (IEC/EN 60068-2-6) 10 - 500 Hz at 30 m/s² (3 G max ) for 60 min. in X-axis, Y-axis, Z-axis directions
Mechanical shock resistance (IEC 60068-2-27) 30 g (300 m/s²) in all directions
Pollution degree 2
Climatic class (IEC) 3K3 according to EN 60721
2
0.32 - 5.3 mm² (AWG 22 -10)
mm
Safety and safety features
Transient overvoltage protection Varistor
Current limitation at short-circuit I
Overvoltage protection Yes, against internal overvoltage
Insulation voltage
Input/Output 4 kV AC (type test), 3 kV AC (routine test)
Input/PE 1.5 kV AC
Output/PE 1.5 kV AC
Degree of Protection IP20
Protection class Class I with PE connection
= 150 % der max. Ausgangsleistung
Überstrom
Standards
Electrical equipment of machines: IEC60204-1 (Overvoltage category III)
Equipping power installations with electronic apparatus: EN 50178/IEC 62103
Safety extra-low voltage: PELV (EN 60204), SELV (EN 60950)
Protection against electric shock: DIN 57100-410
CE: according to EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
RoHS-compliant: RoHS Directive 2011/65/EU
ITE: EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024
Industrial: EN 55011
Mains harmonics limitation: EN 601000-3-2
Electrical Safety (of IT equipment) : SIQ to EN60950-1, UL/c-UL recognized to UL
60950-1, CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1
UL508
Class2: UL/c-UL recognized to UL1310 and CSA C22.2 No. 223 |
Component power supply unit for general use: EN61204-3
Approvals EAC
Design verification as per IEC/EN 61439
Technical data for design verification
Rated operational current for specified heat dissipation I
Heat dissipation per pole, current-dependent P
Equipment heat dissipation, current-dependent P
Static heat dissipation, non-current-dependent P
Heat dissipation capacity P
Operating ambient temperature min. °C -25
Operating ambient temperature max. °C 80
IEC/EN 61439 design verification
10.2 Strength of materials and parts
10.2.2 Corrosion resistance Meets the product standard's requirements.
08/30/2019 Eaton 172890 ED2019 V58.0 EN 2 / 4
n
vid
vid
vs
diss
A 0
W 0
W 0
W 9
W 0