Accessories
CT Kits
Accessories
Description Catalog Number
Safety Cover
Reset Bar
Remote Reset
Communication
The C440 is provided with two levels of communication capability.
Basic Communication via
Expansion Module—
Monitoring Only
Basic communication on
the C440 is accomplished
using an expansion module.
The expansion module plugs
into the expansion bay on
the C440 overload relay,
enabling communications
with the overload via their
Modbus RTU (RS-485)
network. No additional parts
are required. See
figure below.
Safety Cover
Clear Lexan cover that mounts on top of the FLA dial and DIP switches when closed. ZEB-XSC
Reset Bar
Assembles to the top of the overload to provide a larger target area for door
mounted reset operators.
Remote Reset
Remote reset module (24 Vdc)
Remote reset module (120 Vac)
Remote reset module (24 Vac)
Advanced Communication—
Monitoring and Control
C440 also has the ability to
communicate on industrial
protocols such as DeviceNet,
PROFIBUS, Modbus RTU and
Modbus TCP, and Ethernet
(planned) while providing
control capability using I/O.
An expansion module
(mentioned earlier) combined
with a communication
adapter and a communication
module allows easy
integration onto the
customer’s network. See
figure below.
ZEB-XRB
C440-XCOM
ZEB-XRR-120
ZEB-XRR-24
The communication adapter
comes standard with four
inputs and two outputs
(24 Vdc or 120 Vac) while
providing the customer with
flexible mounting options
(DIN rail or panel). See
figure below,
42
42
42
42
42
42
Basic Communication—
Modbus
Note
Customer can wire remote mounted button to reset module (i.e., 22 mm pushbutton, catalog number M22-D-B-GB14-K10).
10 Control Products Catalog CA08102001E—July 2010 www.eaton.com
Advanced Communication—
Communication Adapter with
Communication Module
Motor Protection and Monitoring
Overload Relays
42.4
The following information can be viewed using the communication option:
●
Motor status—running,
stopped, tripped or
resetting
●
Individual rms phase
currents (A, B, C)
●
Average of three-phase
rms current
Communication Accessories
Description Catalog Number
Expansion Module
Communication
Adapter
Expansion module (Remote Reset/Modbus RTU, RS-485 Communication) C440-XCOM
Communication adapter kit (DIN C Panel mounted adapter, required for advance communication option) C440-COM-ADP
●
Percent thermal capacity
●
Fault codes (only available
prior to reset)
●
Percent phase unbalance
●
Ground fault current and
percent
●
Overload relay settings—
trip class, DIP switch
selections, reset selections
●
Modbus address (can be
set over the network)
42
42
42
42
42
42
42
42
42
42
42
42
42
42
DeviceNet communication module kit—120V I/O (consists of C440-XCOM + C441K + C440-COM-ADP) C440-DN-120
DeviceNet communication module kit—24 Vdc I/O (consists of C440-XCOM + C441L + C440-COM-ADP) C440-DN-24
PROFIBUS communication module kit—120V I/O (consists of C440-XCOM + C441S + C440-COM-ADP) C440-DP-120
PROFIBUS communication module kit—24V I/O (consists of C440-XCOM + C441Q + C440-COM-ADP) C440-DP-24
Modbus communication module kit—120V I/O (consists of C440-XCOM + C441N + C440-COM-ADP) C440-MOD-120
Modbus communication module kit—24 Vdc I/O (consists of C440-XCOM + C441P + C440-COM-ADP) C440-MOD-24
Ethernet IP communication module kit—120V I/O (consists of C440-XCOM + C441R + C440-COM-ADP) C440-EIP-120