Cutler Hammer, Div of Eaton Corp Overload Relays Accessories Catalog

42.4
Motor Protection and Monitoring
Overload Relays
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
Accessories
CT Kits
Accessories
Description Catalog Number
Safety Cover
Reset Bar
Remote Reset
The C440 is provided with two levels of communication capability.
Basic Communication via Expansion Module— Monitoring Only
Basic communication on the C440 is accomplished using an expansion module. The expansion module plugs into the expansion bay on the C440 overload relay, enabling communications with the overload via their Modbus RTU (RS-485) network. No additional parts are required. See figure below.
Safety Cover
Clear Lexan cover that mounts on top of the FLA dial and DIP switches when closed. ZEB-XSC
Reset Bar
Assembles to the top of the overload to provide a larger target area for door mounted reset operators.
Remote Reset
Remote reset module (24 Vdc)
Remote reset module (120 Vac)
Remote reset module (24 Vac)
Advanced Communication— Monitoring and Control
C440 also has the ability to communicate on industrial protocols such as DeviceNet, PROFIBUS, Modbus RTU and Modbus TCP, and Ethernet (planned) while providing control capability using I/O.
An expansion module (mentioned earlier) combined with a communication adapter and a communication module allows easy integration onto the customer’s network. See figure below.
ZEB-XRB
C440-XCOM
ZEB-XRR-120
ZEB-XRR-24
The communication adapter comes standard with four inputs and two outputs (24 Vdc or 120 Vac) while providing the customer with flexible mounting options (DIN rail or panel). See figure below,
42
42
42
42
42
42
Basic Communication— Modbus
Note
Customer can wire remote mounted button to reset module (i.e., 22 mm pushbutton, catalog number M22-D-B-GB14-K10).
10 Control Products Catalog CA08102001E—July 2010 www.eaton.com
Advanced Communication— Communication Adapter with Communication Module
Motor Protection and Monitoring
Overload Relays
42.4
The following information can be viewed using the communication option:
Motor status—running, stopped, tripped or resetting
Individual rms phase currents (A, B, C)
Average of three-phase rms current
Communication Accessories
Description Catalog Number
Expansion Module
Communication Adapter
Expansion module (Remote Reset/Modbus RTU, RS-485 Communication) C440-XCOM
Communication adapter kit (DIN C Panel mounted adapter, required for advance communication option) C440-COM-ADP
Percent thermal capacity
Fault codes (only available prior to reset)
Percent phase unbalance
Ground fault current and percent
Overload relay settings— trip class, DIP switch selections, reset selections
Modbus address (can be set over the network)
42
42
42
42
42
42
42
42
42
42
42
42
42
42
DeviceNet communication module kit—120V I/O (consists of C440-XCOM + C441K + C440-COM-ADP) C440-DN-120
DeviceNet communication module kit—24 Vdc I/O (consists of C440-XCOM + C441L + C440-COM-ADP) C440-DN-24
PROFIBUS communication module kit—120V I/O (consists of C440-XCOM + C441S + C440-COM-ADP) C440-DP-120
PROFIBUS communication module kit—24V I/O (consists of C440-XCOM + C441Q + C440-COM-ADP) C440-DP-24
Modbus communication module kit—120V I/O (consists of C440-XCOM + C441N + C440-COM-ADP) C440-MOD-120
Modbus communication module kit—24 Vdc I/O (consists of C440-XCOM + C441P + C440-COM-ADP) C440-MOD-24
Ethernet IP communication module kit—120V I/O (consists of C440-XCOM + C441R + C440-COM-ADP) C440-EIP-120