3-Pole Top Mounted Fuse Block Kit
Field mount to Freedom Series starters and contactors. Designed to save space and reduce installation costs. They provide short circuit protection for branch circuits.
Mounted Fuse Block Kit
Table 33-114. Fuse Block Kits
Fuse Type Catalog
Class H — 30A 250V Class R — 30A 250V
Class G — 15A 300V Class G — 20A 300V Class G — 30A 300V Class G — 60A 300V
Class T — 30A 300V Class T — 60A 300V
Class J — 30A 600V Class J — 60A 600V Type M — 30A 600V Class CC — 30A 600V
Class T — 30A 600V Class T — 60A 600V
Type M fuse block not approved for branch circuit protection.
Number
C350KH21 C350KR21
C350KG37 C350KG38 C350KG31 C350KG32
C350KT31 C350KT32
C350KJ61 C350KJ62 C350KM61 C350KC63
C350KT61 C350KT62
Table 33-115. Approximate Dimensions
Fuse Block Dimensions in Inches (mm)
Class Amperes Volts Wide A High B Deep C D
G 15, 20, 3060300
H 30 250 3.00 (76.2) 3.10 (78.7) 2.23 (56.6) 3.62 (91.9) J 30, 60 600 4.81 (122.2) 4.12 (104.6) 2.82 (71.6) — M, CC 30 600 2.40 (61.0) 3.00 (76.2) 2.04 (51.8) — R 30 250 3.00 (76.2) 3.10 (78.7) 2.23 (56.6) 3.62 (91.9) T 30, 60
30 60
2.40 (61.0)
300
2.62 (66.5)
300
3.44 (87.4)
600
3.75 (95.3)
600
4.87 (123.7)
D AC
3.00 (76.2)
4.25 (108.0)
3.00 (76.2)
3.31 (84.1)
3.00 (76.2)
2.04 (51.8)
2.08 (52.8)——
2.33 (59.2)
2.26 (57.4)
2.58 (65.5)
Price U.S. $
— — —
B
Mechanical Interlock and Reversing Kits
Mechanical interlocks and reversing kits are designed for field assembly of reversing contactors or starters from Freedom Series components. The Reversing Kits include a Mechanical Interlock, stabilizer bar and a pre-cut, trimmed and formed wire set. Auxiliary contacts, if required, must be ordered separately. See Page 33-96.
Cat. No. C321KM60B
Table 33-116. Mechanical Interlock Only
Application Catalog
NEMA Size IEC Size Contactor
00 – 2 A – K Horizontal C321KM60B 3 L – N Horizontal C321KM30 3 to 4 N to P Horizontal C321KM43 4 P – S Horizontal C321KM40 4 to 5 Horizontal C321KM45 4 to 6 S to T/U Horizontal C321KM80 5 Horizontal C321KM50 5 to 6 Horizontal C321KM56 6 T and U Horizontal C321KM70 6 to 7 T/U to V – X Horizontal C321KM90 7 V, W and X Horizontal C321KM34 4 or 5 to 5 P – S to 5 Vertical C321KM55 5 to 6 Vertical C321KM65 6 T and U Vertical C321KM66 6 to 7 T/U to V – X Vertical C321KM67
Without cross-wiring.
For use with latest series product.
Table 33-117. Reversing Kits (Horizontal Contactor Mounting Only)
Application Catalog
NEMA Size IEC Size
00 0 1 2 3
— — 4 5 —
Kit includes (2) NC auxiliary contacts.
A – C D – F — G – K —
L and M N — — P – S
Part No. 23-7165
Mounting

Number
Number
C321KM60K14B C321KM60K13B C321KM60K15B C321KM60K16B C321KM60K17
C321KM60K21 C321KM60K18 C321KM60K19 C321KM60K20 C321KM60K44
Wire Set
Price U.S. $
Price U.S. $
Mounting
Plate
Figure 33-27. Approximate Dimensions in Inches (mm)
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
For more information visit: www.eaton.com CA08102001E
February 2007
NEMA Contactors & Starters Freedom
Accessories
33-93
Solid-State Timers
Solid-State Timer
Solid-State ON DELAY Timer — Side Mounted on Freedom Series NEMA 00 – 2, IEC A – K and C25D, C25E and C25F Frame
This timer is designed to be wired in series with the load (typically a coil).
When the START button is pushed (power applied to timer), the ON DELAY timing function starts. At the completion of the set timing period, timer and series wired load will both be energized.
Table 33-118. Mounted Timer Product Selection
Timing Range Catalog
.1 – 1.0 Seconds 1 – 30 Seconds
30 – 300 Seconds
5 – 30 Minutes
Add operating voltage Suffix to Catalog Number. A = 120V, B = 240V, E = 208V
Rated .5 ampere pilot duty — not to be used on larger contactors.
Terminal connections are quick connects only. Two per side.

Number
C320TDN1_ C320TDN30_ C320TDN300_ C320TDN3000_
Price U.S. $
Shorting Bar Kits
These kits provide phase-to-phase power connections of contactors for field assembly. The kits include bus connections and mounting hardware. The shorting bars connect all three phases of a single contactor.
Table 33-119. Product Selection
Description Catalog
NEMA Size 3,
IEC Sizes L – N
NEMA Size 4,
IEC Sizes A – S
NEMA Size 6,
IEC Sizes T and U
Number
C321SB18
C321SB19
C321SB22
Price U.S. $
Pneumatic Timers — Top Mounted
Attachment mounts on top of any NEMA Size 00 – 2 or IEC Size A – K Freedom Series starter or contactor (top mounted auxiliary contacts can not be installed on device when timer is used). Timer unit has 1NO-1NC iso­lated timed contacts — circuits in each pole must be the same polarity. Units are convertible from OFF to ON DELAY or vice-versa.
Table 33-120. Product Selection
Timing Range Catalog
.1 to 30 Seconds 10 to 180 Seconds
Number
C320TP1 C320TP2
Price U.S. $
Table 33-121. Maximum Ampere Ratings
Description Volts AC
120 240 480 600
Make Break
30315
1.5
7.5 .756.6
Locking Cover for Overload Relay — C306 Only
Snap-on transparent or opaque plastic panel for covering access port to the overload relay trip setting dial — helps prevent accidental or unauthorized changes to trip and reset setting.
Table 33-122. Product Selection
Description Min.
Clear cover, no accessibility
Gray cover, no accessibility, with Auto only nib
Gray cover, no accessibility, with Manual only nib
Gray cover with FLA dial accessibility, A, B, C, D positions and Auto only nib
Gray cover with FLA dial accessibility, A, B, C, D positions and Manual only nib
Ordering Quantity (Std. Pkg.)
50 C320PC3
50 C320PC4
50 C320PC5
50 C320PC6
50 C320PC7
Catalog Number
Price U.S. $
Identification Markers
Designed to snap on the face of con­tactor for easy, personalized identifica­tion of individual devices. Includes holder and labels.
Table 33-123. Product Selection
Description Catalog
Identification Marker
Number
C320DL2
Price U.S. $
Control Circuit Fuse Block
These panel mounted fuse holders, designed for control circuit protection or other similar low current requirements, have extractor type fuse caps. The Class CC rejection type fuses (KTK-R) used in these holders are intended for use with equipment designated as being suitable for use on systems having high available fault currents. If branch circuit protective device is 45A or greater, C320FBR fuse kit may be required for control circuit protection per NEC 430-72.
Table 33-124. Product Selection
Type Max.
Fuse Holder Only
A fuse is not supplied, but holder will accept a Bussman Type KTK or KTK-R (13/32" x 1-1/2") fuse, 600V maximum.
Includes a 5A, 600V KTK-R fuse.
Fuse
Amperes
15 30
1.88 (47.8)
Figure 33-28. Approximate Dimensions in Inches (mm)
1.25 (31.8) .97
(24.6)
Catalog Number
C320FB C320FBR
.88
(22.4)
2.06
(52.3)
Price U.S. $
1.19
(30.2)
33
CA08102001E For more information visit: www.eaton.com
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
33-94
NEMA Contactors & Starters Freedom
February 2007
Accessories
33
DIN Rail Mounting Channel — 35 mm
Designed for DIN rail mounting of IEC style contactors and starters.
DIN Rail
Table 33-125. Product Selection
Description Catalog
Number
1 Meter Length MC382MA1
Price U.S. $
Finger Protection Shields
Snap-on shields for both contactors and starters provide IEC Type IP20 Fin­ger Protection. Prevents accidental contact with line/load terminals.
Table 33-126. Product Selection
Application Catalog
NEMA Size 00, IEC Sizes
A – C
NEMA Size 0, IEC Sizes
D – F
NEMA Sizes 1 – 2, IEC
Sizes G – K
Contactors Reversing Contactors
NEMA Size 1
Starters Reversing Starters
NEMA Size 2, IEC Sizes
G – K
Starters Reversing Starters
Number
C320LS1
C320LS2
C320LS3 C320LS4
C320LS5 C320LS6
C320LS7 C320LS8
Price U.S. $
Adapter to DIN Rail Mount
NEMA 1 – 2 and IEC G – K Contactors
Designed to allow DIN rail mounting of NEMA 1 – 2 and IEC G – K contactors. Includes all hardware required to con­vert contactors from panel mounting to 35 mm DIN rail mounting.
Table 33-127. Product Selection
Catalog Number
C320DN65
Price U.S. $
Transient Suppressor Kits
These kits limit high voltage transients produced in the control circuit when power is removed from the contactor or starter coil. There are three separate suppressors for use on 24 – 120V, 208 – 240V or 277 – 480V coils respectively.
Cat. No. C320TS2
These devices mount directly to the coil terminals of Freedom Series con­tactors or starters NEMA Sizes 00 – 2, IEC Sizes A – K and lighting contactors 10 – 60A. Reversing devices will require two.
Table 33-128. Product Selection
Description Coil
Transient Suppressor
Suppressor is compatible with coil voltages/ ranges as shown, both 50 and 60 Hz.
Voltage
24/120V 208/240V 277/480V
Catalog Number
C320TS1 C320TS2 C320TS3
Price U.S. $
NEMA Sizes 3 – 5, IEC Sizes L – S
This device mounts on top of any side mounted auxiliary contact on Freedom Series NEMA Sizes 3 – 5, IEC Sizes L – S and lighting contac­tors 100 – 300A. It connects across coil terminals on any 120V contactor or starter magnet coil (reversing starters or contactors require 2).
Limits high voltage transients pro­duced in the circuit when power is removed from the coil.
Table 33-129. Product Selection
Description Coil
Transient Suppressor
Voltage
120V C320AS1
Catalog Number
Price U.S. $
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 1CD1C
For more information visit: www.eaton.com CA08102001E