Cutler Hammer, Div of Eaton Corp Motor Control, Motor Protection Catalog

Electrical Sector Solutions
Volume 5:
Motor Control
and
Protection
Volume 1—Residential and Light Commercial
1
Volume 2—Commercial Distribution
Volume 4—Circuit Protection
Volume 5—Motor Control and Protection
Tab 1—IEC Contactors and Starters . . . . . . . . . . . . . . . . . . . V5-T1-1
Tab 2—NEMA Contac
Tab 3—NEMA Manual Starters . . . . . . . . . . . . . . . . . . . . . . . V5-T3-1
Tab 4—Definite Purpose Contactors and Starters . . . . . . . . V5-T4-1
Tab 5—Motor Protection and Monitoring . . . . . . . . . . . . . . V5-T5-1
Tab 6—Lighting Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T6-1
Tab 7—Vacuum Contactors and Starters . . . . . . . . . . . . . . . V5-T7-1
tors and Starters . . . . . . . . . . . . . . . .
V5-T2-1
2 3 4 5
Tab 8—Rotary Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T8-1
Appendix 1—Eaton Terms & Conditions . . . . . . . . . . . . . . . V5-A1-1
Appendix 2—Catalog Parent Number Index . . . . . . . . . . . . V5-A2-1
Appendix 3—Alphabetical Product Index . . . . . . . . . . . . . . V5-A3-1
Volume 6—Solid-State Motor Control
6
Volume 7—Logic Control, Operator Interface
and Connectivity Solutions
7
Copyright
Dimensions, Weights and Ratings
Terms and Conditions
Technical and Descriptive Publications
Dimensions, weights and ratings given in this catalog are approximate and should not
be used for construction purposes
upon request. All listed product specifications and ratings are subject to change without notice. Photographs are representative of production units.
All prices and discounts are subject to change without notice. When price changes occur, they are published in Eaton’s Price and Availability Digest (PAD). All orders accepted by Eaton’s Electrical Sector are subject to the general terms and conditions as set forth in Appendix 1—Eaton Terms & Conditions.
This catalog contains brief technical data for proper selection of products. Further information is available in the form of technical information publications and illustrated brochures. If additional product information is required, contact your local Eaton Products Distributor.
. Drawings containing exact dimensions are available
Compliance with Nuclear Regulation 10 CFR 21
Eaton products are sold as commercial grade products not intended for application in facilities or activities licensed by the United States Nuclear Regulatory Commission for atomic purposes, under 10 CFR 21. Further certification will be required for use of these products in a safety-related application in any nuclear facility licensed by the U.S. Nuclear Regulatory Commission.
WARNING
The installation and use of Eaton products should be in accordance with the provisions of the U.S. National Electrical Code are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment.
These catalog pages do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Eaton Products Distributor or Sales Office. The contents of this catalog shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Eaton’s Electrical Sector. The warranty contained in the contract between the parties is the sole warranty of Eaton. Any statements contained herein do not create new warranties or modify the existing warranty.
®
and/or other local codes or industry standards that
Copyright ©2019 Eaton, All Rights Reserved.
Eaton is a global leader in power distribution, power quality, control and automation, and monitoring products.
At Eaton, we believe a reliable, efficient and safe power system is the foundation of every successful enterprise. Through innovative technologies, cutting-edge products and our highly skilled services team, we empower businesses around the world to achieve a powerful advantage.
In addition, Eaton is committed to creating and maintaining powerful customer relationships built on a foundation of excellence. From the products we manufacture to our dedicated customer service and support, we know what’s important to you.
Solutions
Eaton takes the complexity out of power systems management with a holistic and strategic approach, leveraging our industry-leading technology, solutions and services. We focus on the following three areas in all we do:
Reliability—maintain the appropriate level of power continuity without disruption or unexpected downtime
Efficiency—minimize energy usage, operating costs, equipment footprint and environmental impact
Safety—identify and mitigate electrical hazards to protect what you value most
Introduction
Using the Eaton Catalog Library
As we grow, it becomes increasingly difficult to include all products in one or two comprehensive catalogs. Knowing that each user has their specific needs, we have created a library of catalogs for our products that when complete, will contain 15 volumes. Since the volumes will continuously be a work in progress and updated, each volume will stand alone. Refer to our volume directory, MZ08100001E, for a quick glance of where to look for the products you need. The 15 volumes include:
Volume 1—Residential and Light Commercial (CA08100002E)
Volume 2—Commercial Distribution (CA08100003E)
Vol u me 3— Po wer Distribution and Control Assemblies (CA08100004E)
Volume 4—Circuit Protection (CA08100005E)
Volume 5—Motor Control and Protection (CA08100006E)
Volume 6—Solid-State Motor Control (CA08100007E)
These volumes are not all-inclusive of every product, but they are meant to be an overview of our product lines. For our full range of product solutions and additional product information, consult Eaton.com/electrical and other catalogs and product guides in our literature library. These references include:
The Consulting Application Guide (CA08104001E)
Volume 7—Logic Control, Operator Interface and Connectivity Solutions (CA08100008E)
Volume 8—Sensing Solutions (CA08100010E)
Volume 9—Original Equipment Manufacturer (CA08100011E)
Volume 10—Enclosed Control (CA08100012E)
Volume 11—Vehicle and Commercial Controls (CA08100013E)
The Eaton Power Quality Product Guide (COR01FYA)
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions (CA08100014E)
Volume 13—Counters, Timers and Tachometers (CA08100015E)—Available in electronic format only
Vol u me 14—Fuse s (CA08100016E)—Available in electronic format only
Volume 15—Solar Inverters and Electrical Balance of System (CA08100018E)
If you don’t have the volume that contains the product or information that you are looking for, not to worry. You can access every volume of the catalog library at Eaton.com/electrical in the Literature Library.
By installing our Automatic Tab Updater (ATU), you can be sure you always have the most recent version of each volume and tab.
Volume 5—Motor Control and Protection CA08100006E—August 2018
i
Introduction
Icons
Green Leaf
Eaton Green Solutions are products, systems or solutions that represent Eaton benchmarks for environmental performance. The green leaf symbol is our promise that the solution has been reviewed and documented as offering exceptional, industry-leading environmental benefits to customers, consumers and our communities. Though all of Eaton’s products and solutions are designed to meet or exceed applicable government standards related to protecting the environment, our products with the Green Leaf designation further provide “exceptional environmental benefit.”
Learn Online
When you see the Learn Online icon, go to Eaton.com/electrical and search for the product or training page. There you will find 100-level training courses, podcasts, webcasts or games and puzzles to learn more.
Drawings Online
When you see the Drawings Online icon, go to Eaton.com/electrical and find the products page. There you will find a tab that includes helpful product drawings and illustrations.
Contact Us
If you need additional help, you can find contact information under the Customer Care heading of Eaton.com/electrical.
ii
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
IEC Contactors and Starters
1.1 XT IEC Power Control
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-2
Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-3
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-18
Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-35
XTSE Contactors .
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-130
C440/XT Electronic Overload Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-143
nual Motor Protectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ma
Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-193
XT Electronic Manual Motor Protector . . . . . . . . . . . . . . . . . . . . . . . .
EMS—Electronic Motor Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-232
XT DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-236
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V5-T1-128
V5-T1-159
V5-T1-219
V5-T1-234
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018 V5-T1-1
1
1
1.1
XT IEC Power Control
IEC Contactors and Starters
XT IEC Power Control
1
1
1
1
1
1
1
1
1
1
1
Product Overview
The XT line of IEC power
1
control offers starting and protection solutions ideal for
1
control panels.
Innovations in the design and
1
development allow users to reduce material costs, reduce
1
installation effort, and enhance panel safety and
1
performance all in a compact design. Some of these key innovations include:
1
1
1
1
1
1
1
1
1
Toolless assembly of man
ual motor controlle
d reversing contactors
an Low coil consumption Front accessibility to coil
terminations Built-in surge suppression
on electronic coils Built-in auxiliary contact for
co
ntactors up to 32A in
mm frame
45 Finger-safe and back-of-
hand proof ratings Direct PLC control on
1
85A–2000A cont
rs
a
actors
e XT line includes a large
Th offering of power control components and accessories that cover a broad range of applications and ratings:
Three-pole contactors to 20
00A
Four-pole contactors to 200A
Capacitor contactors to 68
0 kVAR
Mini contactors to 9A
Relays to 16A
Thermal overload relays to 630A
Electronic overload relays to 1500A
Manual motor protectors to 65A
Manual motor controllers an
d combination ntrollers to 65A
co
motor
Contents
Description Page
Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-3
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-18
Contactors and Starters . . . . . . . . . . . . . . . . . . . . V5-T1-35
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . V5-T1-130
C440/XT Electronic Overload Relay . . . . . . . . . . . V5-T1-143
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . V5-T1-159
Combination Motor Controllers . . . . . . . . . . . . . . . V5-T1-193
XT Electronic Manual Motor Protector . . . . . . . . . V5-T1-219
EMS—Electronic Motor Starter . . . . . . . . . . . . . . V5-T1-232
XT DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-234
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-236
1
1
1
1
1
V5-T1-2
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
Relays and Timers
An Eaton Green Solution
XT IEC Power Control
1.1
Relays and Timers
Product Description
Eaton’s new line of XT relays and timers includes mini and standard frame control relays and auxiliary contacts, mini electronic on-delay and multi-function timers and an electronic star-delta (wye-delta) timer for use in star-delta (wye-delta) combinations. Because XT meets UL standards, it is the perfect product solution for IEC applications all over the world. The compact, space saving and easy to install XT line of IEC contactors and starters is the efficient and effective solution for customer applications.
®
, CSA® and CE
Features
For use with mini and st
andard frame siz
ntactors and starters
co
Control relays
AC control from 12V to 55
0V 50 Hz, 600V 60 Hz
DC control from 1
2V to 220V
On-delay and multi­function timers
24–240 Vac/Vdc control
Available with screw or sp
ring cage terminals
Four-pole configurations
IP20 finger and back-of­hand proof
Large ambient temperature range: –25° to 50°C [–13
22°F]
to 1
The XTRE control relays have positively driv
ntacts between the relay
co and the auxiliary contac mod
ules as well as within
the auxiliary cont
ules
mod
e
en
act
Contents
Description Page
Relays and Timers
Catalog Number Selection . . . . . . . . . . . . . . . . V5-T1-4
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V5-T1-5
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-6
Technical Data and Specifications . . . . . . . . . . V5-T1-12
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-16
1
1
1
1
1
Miniature Controls . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-18
Contactors and Starters . . . . . . . . . . . . . . . . . . . . V5-T1-35
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . . V5-T1-130
C440/XT Electronic Overload Relay . . . . . . . . . . . . V5-T1-143
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . V5-T1-159
Combination Motor Controllers . . . . . . . . . . . . . . . V5-T1-193
XT Electronic Manual Motor Protector . . . . . . . . . V5-T1-219
EMS—Electronic Motor Starter . . . . . . . . . . . . . . . V5-T1-232
XT DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-234
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-236
1
1
1
1
1
1
Standards and Certifications
IEC EN 60947
CE approved
UL
CSA
1
1
1
1
1
Instructional Leaflets
Pub51219 XTRM Mini Control Relays
Pub51210 XTRE Control Relays
Pub51244 XTTR Electronic Star-Delta (Wye-Delta) Timer
Pub51245 XTMT Mini Electronic On-Delay and
Multi-Function Timers
1
1
1
1
°
1
1
t
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
1
1
1
V5-T1-3
1.1
Product Family Code
RM = Mini IEC control
relay
RE = IEC control relay
Coil Code
See table on Page V5-T1-5.
Product Line Prefix
XT = XT IEC power control
Terminations
Blank =Screw
terminals
C = Spring cage
terminals
Conventional Thermal
Current Rating
10 = 10A
Frame
XTRM A = 45 mm—mini
XTRE B = 45 mm—standard
Contact
Configuration 40 = 4NO
31 = 3NO-1NC 22 = 2NO-2NC
XT RE C 10 B 22 AD
Product Family Code
MT = Mini IEC timing
relay
TR = Electronic timing
relay star-delta (wye-delta)
Coil Code
B = 24–240 Vac/Vdc
Product Line Prefix
XT = XT IEC power control
Function
XTMT 11 = On-delay 70 = Adjustable
XTTE 51 = Star-delta
Time Range Max.
XTMT 30S = 1.5–30s 60H = 05–1s
0.15–3s
0.5–10s 3–60s
0.15–3 min
0.5–3 min 3–60 min
0.15–3h
0.5–3h 3–60h
XTTR 60S =3–60s
Conventional
Thermal Current
Rating
6 = 6A
Frame
A = 45 mm
XT MT 6 B 30S 11 B
Catalog Number Selection
1
XT—Relays
1
1
1
1
1
1
1
1
XT—Timers
1
1
IEC Contactors and Starters
XT IEC Power Control
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-4
Volume 5—Motor Control and Protection CA08100006E—August 201m
IEC Contactors and Starters
XTRM10A_
14
13 333443
44
A1
A2
23
24
14
13 2122333443
44
A1
A2
14
13
21
2231324344
A1
A2
XTREC10_
14
13 333443
44
A1
A2
23
24
14
13 2122333443
44
A1
A2
14
13
21
2231324344
A1
A2
XT IEC Power Control
1.1
Product Selection
When Ordering
Orders must be placed in multiples of the package quantity listed
DC operated control relays have a built-in suppressor circuit
Contact terminal numbers to EN50011
Coil terminal numbers to EN50005
Mini Control Relays
Conventional Thermal
(A)
Current I
th
10 4NO 6 3 1.5 XTRM10A40_
10 3NO-1NC 6 3 1.5 XTRM10A31_
10 2NO-2NC 6 3 1.5 XTRM10A22_
Contact Configuration
Control Relays
Conventional Thermal Current Open at 60°C I
16 4NO 6 4 1.5 XTRE10B40_ XTREC10B40_
th
(A)
Contact Configuration
Rated Operational Current
(A)
AC-15 I
e
220–240V 380–415V 500V
Rated Operational Current
(A)
AC-15 I
e
220–240V 380–415V 500V
Circuit Symbol
Circuit Symbol
Screw Terminal Catalog Number
1
Screw Terminal Catalog Number
2
Spring Cage Ter mi na l Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16 3NO-1NC 6 4 1.5 XTRE10B31_ XTREC10B31_
16 2NO-2NC 6 4 1.5 XTRE10B22_
3
XTREC10B22_
3
Coil Voltage Suffix
Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code
110V 50 Hz, 120V 60 Hz
220V 50 Hz, 240V 60 Hz
230V 50 Hz
24V 50/60 Hz
24 Vdc
Notes
1
Underscore (_) indicates magnet coil suffix required. See Coil Voltage Suffix table above.
2
DC operated control relays XTRM(C)10A22_ cannot be used with front mount auxiliary contacts.
3
DC operated control relays XTRE(C)10B22_ can only be combined with two-pole auxiliary contacts.
A
B
F
T
TD
415V 50 Hz, 480V 60 Hz
550V 50 Hz, 600V 60 Hz
208V 60 Hz
190V 50 Hz, 220V 60 Hz
240V 50 Hz, 277V 60 Hz
C
D
E
G
H
380V 50 Hz, 440V 60 Hz
380V 60 Hz
12V 50/60 Hz
42V 50 Hz, 48V 60 Hz
48V 50 Hz
L
P
R
W
Y
120 Vdc
220 Vdc
12 Vdc
48 Vdc
AD
BD
RD
WD
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
V5-T1-5
1.1
XTMCXF_
54
53
61
62
515261
62
71
72
82
81
536171
81
82
72
62
54
54
53
61
62
717283
84
54
53 61
627374
83
84
54
63 73
64
74
53
83
84
58
57
65
66
717283
84
Accessories
1
Auxiliary Contacts
1
1
1
1
1
1
1
IEC Contactors and Starters
XT IEC Power Control
Front-Mount Auxiliary Contacts for Use with XTRM Mini Control Relays
Rated Operational Current AC-15 I
(A)
Conventional Thermal Current,
Open (A)
I
th
10 4 2 1.5 2NC 5 XTMCXFA02
10 4 2 1.5 1NO-1NC 5 XTMCXFA11
220V 230V 240V
e
380V 400V 415V 500V
Contact Configuration Contact Sequence
51
61
62
52
Pkg. Qty.
1
Screw Terminal Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
10 4 2 1.5 2NO 5 XTMCXFA20
10 4 2 1.5 4NC 5 XTMCXFA04
10 4 2 1.5 1NO-3NC 5 XTMCXFA13
10 4 2 1.5 2NO-2NC 5 XTMCXFA22
10 4 2 1.5 3NO-1NC 5 XTMCXFA31
10 4 2 1.5 4NO 5 XTMCXFA40
10 4 2 1.5 1NO-1NC
Notes
1
Orders must be placed in multiples of package quantity listed.
2
One early-make contact (NOE), one late-break contact (NCL).
1NO
E
-1NC
L
53
546364
5 XTMCXFAL22
2
1
1
1
1
1
1
V5-T1-6
Volume 5—Motor Control and Protection CA08100006E—August 201m
IEC Contactors and Starters
Two - Po le
Four-Pole
4
51
52
61
62
5
54
53 61
627374
83
84
54
53
61
62
717283
84
XT IEC Power Control
1.1
Front-Mount Auxiliary Contacts for Use with XTRE Control Relays
Rated Operational Current AC-15 I
Conventional Thermal Current,
(A), Open at 60°C Poles
I
th
16 2 6 3 1.5 2NO 5 XTCEXFAC20
16 2 6 3 1.5 1NO-1NC 5 XTCEXFAC11
16 2 6 3 1.5 2NC 5 XTCEXFAC02
16 2 6 3 1.5 1NO
16 4 6 3 1.5 4NO 5 XTCEXFAC40
16 4 6 3 1.5 3NO-1NC 5 XTCEXFAC31
16 4 6 3 1.5 2NO-2NC 5 XTCEXFAC22
16 4 6 3 1.5 1NO-3NC 5 XTCEXFAC13
16 4 6 3 1.5 4NC 5 XTCEXFAC04
16 4 6 3 1.5 1NO-1NC
220V 230V 240V
380V 400V 415V 500V
(A)
e
Contact Configuration Circuit Symbol
-1NC
E
-1NC
1NO
E
1
Pkg. Qty.
63
53
6
54
61
53
62
54
L
L
57 6
66
58
53
63 73
64
54
536171
54
62
515261
62
65
57
66
58
83
84
74
82
72
71
81
72
82
717283
81
84
5 XTCEXFALC11
5 XTCEXFCLC22
2
Screw Terminal Catalog Number
1
1
1
1
3
1
1
1
4
1
3
3
1
1
1
3
1
1
1
1
4
1
1
Notes
1
Interlocked opposing contacts, to IEC/EN 60947-5-1 Annex L (positively driven), within the auxiliary contact modules (not NOE and NCL contacts) and between the auxiliary contacts and built-in contacts of the XTRE control relays.
2
Orders must be placed in multiples of package quantity listed.
3
Catalog number is shown with screw type terminal. For spring cage, add a “C” before the last 2 digits. For example, to order a spring cage version of the XTCEXFAC22, change the catalog number to XTCEXFACC22.
4
One early-make contact (NOE), one late-break contact (NCL).
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
V5-T1-7
IEC Contactors and Starters
XTCEXVSB_
XTMCXVS_
XTRM Relay with Installed Suppressor
XTCEXVSLB_
A1
A2
XTCEXRSB_
1.1
Suppressors
1
For AC operated contactors 50–60 Hz. On DC operated contactor relays and on XTRE10B, the suppressor circuit is built-in. Note dropout delay.
1
Varistor Suppressor
1
1
1
1
1
XT IEC Power Control
12
Varistor Suppressor for XTRE
Voltage
24–48 XTRE(C)10B 10 XTCEXVSBW
48–130 10 XTCEXVSBA
130–240 10 XTCEXVSBB
240–500 10 XTCEXVSBC
For Use with… Contact Sequence
A1
A2
Pkg. Qty.
3
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Varistor Suppressor for XTRM
Voltage
24–48 XTRM6A_,
48–130 XTRM6A_,
110–250 XTRM6A_,
380–415 XTRM6A_,
For Use with… Circuit Symbol
XTRM9A_
XTRM9A_
XTRM9A_
XTRM9A_
Varistor Suppressor with Integrated LED
Varistor Suppressor for XTRE
For Use with… Contact Sequence
For Use with… Contact Sequence
RC Suppressor
Voltage
24–48 XTRE(C)10B 10 XTCEXVSLBW
130–240 10 XTCEXVSLBB
12
RC Suppressor for XTRE
Voltage
24–48 XTRE(C)10B 10 XTCEXRSBW
48–130 10 XTCEXRSBA
110–240 10 XTCEXRSBB
240–500 10 XTCEXRSBC
Notes
1
Note dropout delay.
2
For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor.
3
Orders must be placed in multiples of package quantity listed.
12
A1
A2
A1
A2
Pkg.
3
Qty.
10 XTMCXVSW
10 XTMCXVSA
10 XTMCXVSB
10 XTMCXVSN
Pkg. Qty.
Pkg. Qty.
3
3
Catalog Number
Catalog Number
Catalog Number
1
1
V5-T1-8
Volume 5—Motor Control and Protection CA08100006E—August 2018
RC Suppressor
XTMCXRS_
XTRM Relay with Installed Suppressor
A1
A2
XTCEXVSLBB
XTCEXCNC
XTMCXCN
XTCEXMLB
12
RC Suppressor for XTRM
Voltage
24–48 XTRM6A_,
48–130 XTRM6A_,
110–250 XTRM6A_,
For Use with…
XTRM9A_
XTRM9A_
XTRM9A_
3
Circuit Symbol
IEC Contactors and Starters
XT IEC Power Control
Pkg.
4
Qty.
10 XTMCXRSW
10 XTMCXRSA
10 XTMCXRSB
Catalog Number
1.1
1
1
1
1
1
1
Free-Wheel Diode Suppressor
In addition to the built-in suppressor circuit for DC actuated contactors. Prevents negative breaking voltage when contactors are used in combination with a safety PLC.
Free-Wheel Diode Suppressor for XTRE
Connector
Pkg. Qty.
For Use with…
XTRE10B
4
Catalog Number
Voltage
130–240
5
Connector
For Use with…
XTRE(C)10B 50 XTCEXCNC
XTRM10A 50 XTMCXCN
Pkg.
4
Qty.
10 XTCEXVSLBB
Mechanical Interlock
Catalog Number
6
Mechanical Interlock
For Use with…
XTRE10B_ 5 XTCEXMLB
XTRM10A_ 5 XTMCXML
Pkg. Qty.
1
1
1
1
1
1
1
1
4
Catalog Number
1
1
1
1
1
1
Notes
1
Note dropout delay.
2
For AC operated contactors, 50/60 Hz. DC operated contactors have an integrated suppressor.
3
For AC operated contactors, 50/60 Hz. Note dropout delay.
4
Orders must be placed in multiples of package quantity listed.
5
For mechanically arranging contactors in combinations. Distance between contactors is 0 mm.
6
For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted. For Frame B, mechanical lifespan is 2.5 x 10
6
operations and the distance between contactors is 0 mm.
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
1
1
1
1
1
1
1
1
V5-T1-9
IEC Contactors and Starters
XTCEXT_
575865
66
A1
A2
1.1
Electronic Timer Modules
1
Front- (top-) mounted timer modules for use with XTRE10B control relays. Can not be combined with top-mount auxiliary contacts, XTCEXF_.
1
1
1
1
1
XT IEC Power Control
Electronic Timer Modules for XTRE
Voltage Contact Sequence Timing Range
On-Delay
24 Vac/Vdc 0.05–1s
100–130 Vac XTCEXTEEC11A
200–240 Vac XTCEXTEEC11B
0.5–10s 15–100s
For Use with…
XTRE10B_ 1 XTCEXTEEC11T
Pkg. Qty.
1
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Off-Delay
24 Vac/Vdc 0.05–1s XTRE10B_ 1 XTCEXTED1C11T
100–130 Vac XTCEXTED1C11A
200–240 Vac XTCEXTED1C11B
24 Vac/Vdc 0.5–10s XTRE10B_ 1 XTCEXTED10C11T
100–130 Vac XTCEXTED10C11A
200–240 Vac XTCEXTED10C11B
24 Vac/Vdc 5–100s XTRE10B_ 1 XTCEXTED100C11T
100–130 Vac XTCEXTED100C11A
200–240 Vac XTCEXTED100C11B
Star-Delta
24 Vac/Vdc 1–30s XTRE10B_ 1 XTCEXTEYC20T
100–130 Vac XTCEXTEYC20A
200–240 Vac XTCEXTEYC20B
Sealable Shroud
Note
1
Orders must be placed in multiples of package quantity listed.
A1
A2
A1
A2
Transparent sealable shroud used to protect electronic timer modules from unwanted access.
575865
57
58
66
67
68
XTCEXTEE, XTCEXTED, XTCEXTEY
1 XTCEXTESHRD
1
1
1
1
1
1
1
1
1
1
V5-T1-10
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
XTMT6A_
A1A215
16 18
XTTR6A60S51
XT IEC Power Control
1.1
Mini Electronic Timers
Mini Electronic On-Delay Timers
Conventional Thermal Current
(A)
I
e
6 3 3 1.5–30 sec Fixed, on-delay XTMT6A30S11B
6 3 3 0.05–1 sec
Electronic Star-Delta (Wye-Delta) Timers
Electronic Star-Delta (Wye-Delta) Timers
Conventional Thermal Current
(A)
I
e
6 3 3 3–60 sec Fixed, star-delta XTTR6A60S51B
Rated Operational Current I
AC-11 Amps
e
Rated Operational Current I
AC-11 Amps
e
Tim e Range Function
0.15–3 sec
0.5–10 sec 3–60 sec
0.15–3 min
0.5–10 min 3–60 min
0.15–3h
0.5–10h 3–60h
Tim e Range Function
Adjustable: on-delay; fleeting contact on energization; flashing; pulse generating; ON-OFF
Terminal Marking According to EN 50042 Catalog Number 220/230/240V 380/400/440V
Z2Z1 A1
15
16 18
A2
Terminal Marking According to EN 50042 Catalog Number 230V 400V
A1
XTMT6A60H70B
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Actuating Voltage
24–240 50/60 Hz 24–240 Vdc
Admissible Cable Length Connection to
Cable unscreened, with cable cross-section 0.5–1.5 mm Two-core cable M250 Two-core cable in the same cable duct with the main cable, 50/60 Hz M50
2
Y1/Y2, Z1/Z2
A2
1
181728
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
V5-T1-11
IEC Contactors and Starters
1.1
Technical Data and Specifications
1
Relays and Timers
1
Description XTRE XTCEXFAC_ XTCEXTE_ XTRM XTMCXFA_
General
1
Standards IEC/EN 60947,
1
Lifespan, mechanical—operations
1
AC operated 20,000,000 10,000,000 3,000,000 10,000,000 10,000,000
DC operated 20,000,000 10,000,000 3,000,000 20,000,000 20,000,000
1
Maximum operating frequency (ops/hr) 9000 9000 9000 9000
1
Climatic proofing
Ambient temperature
1
Open (°C, min./max.) –25/60 –25/60 –40/80 –25/50 –25/50
Enclosed (°C, min./max.) –25/40 –25/40 –25–60 –25/40 –25/40
1
Ambient temperature for storage (°C, min./max.) –40/80 –40/80 –25–40
Mounting position As required,
1
1
1
XT IEC Power Control
IEC/EN 60947, VDE 0660, UL, CSA
11 1 11
180°
VDE 0660,
UL, CSA
30°
90°90°90°
DIN EN 61812, IEC/EN 60947, VDE 060, UL, CSA
not suspended
IEC/EN 60947, VDE 0660, UL, CSA
As required, except vertically A1/A2 at the bottom
IEC/EN 60947, VDE 0660, UL, CSA
As required, except vertically A1/A2 at the bottom
1
Mechanical shock resistance (IEC/EN 60068-2-27) Half-sinusoidal shock 10 ms
1
Base unit with auxiliary contact module
Make contact 7g 7g 6g 10g 10g
1
Break contact 5g 5g 6g 8g 8g
Degree of protection IP20 IP20 IP20 IP20 IP20
1
Protection against direct contact from the front when actuated by a perpendicular test finger (IEC 536)
1
Weight
AC operated (kg) 0.23 0.05 0.08 0.17
1
DC operated (kg) 0.28 0.05 0.08 0.20
1
Terminal capacity
Screw terminals
1
1
1
1
1
1
1
1
1
1
1
2
) 1 x (0.75–4)0.
Solid (mm
2
Flexible with ferrule (mm
Solid or stranded (AWG) 18–14 18–14 18–14
Terminal screw M3.5 M3.5 M3.5 M3.5 M3.5
Pozidriv screwdriver Size 2 Size 2 Size 2 Size 2 Size 2
Standard screwdriver (mm) 0.8 x 5.5
Max. tightening torque (Nm) 1.2 1.2 1.2 1.2 1.2
Spring cage terminals
2
) 1 x (0.75–2.5)
Solid (mm
Flexible with or without ferrule DIN 46228 (mm
Solid or stranded (AWG) 18–14 18–14 18–14 18–14
Standard screwdriver (mm) 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5 0.6 x 3.5
Note
1
Damp heat, constant, to IEC 60068-2-78; damp heat, cyclical, to IEC 60068-2-30.
) 1 x (0.75–2.5)
2
) 1 x (0.75–2.5)
Finger and back-of-hand proof
2 x (0.75–2.5)
2 x (0.75–2.5)
1 x 6
2 x (0.75–2.5)
2 x (0.75–2.5)
Finger and
back-of-hand proof
1 x (0.75–4)0.
2 x (0.75–2.5)
1 x (0.75–2.5)
2 x (0.75–2.5)
0.8 x 5.5
1 x 6
1 x (0.75–2.5)
2 x (0.75–2.5)
1 x (0.75–2.5)
2 x (0.75–2.5)
Finger and back-of-hand proof
1 x (0.75–2.5) 2 x (0.75–1.5)
1 x (0.75–1.5) 2 x (0.75–1.5)
0.8 x 5.5 1 x 6
— —
— —
Finger and back-of-hand proof
1 x (0.75–2.5) 2 x (0.75–2.5)
1 x (0.75–1.5) 2 x (0.75–1.5)
0.8 x 5.5 1 x 6
1 x (0.75–2.5) 2 x (0.75–2.5)
1 x (0.75–2.5) 2 x (0.75–2.5)
Finger and back-of-hand proof
1 x (0.75–2.5) 2 x (0.75–2.5)
1 x (0.75–1.5) 2 x (0.75–1.5)
0.8 x 5.5 1 x 6
1 x (0.75–2.5) 2 x (0.75–2.5)
1 x (0.75–2.5) 2 x (0.75–2.5)
V5-T1-12
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
XT IEC Power Control
1.1
Relays and Timers, continued
Description XTRE XTCEXFAC_ XTCEXTE_ XTRM XTMCXFA_
Contacts
Interlocked opposing contacts to ZH 1/457, including auxiliary contact module
Rated impulse withstand voltage (U
Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3
Rated insulation voltage (U
Rated operational voltage (U
Safe isolation to VDE 0106 Part 101 and Part 101/A1
Between coil and auxiliary contacts (Vac) 400 400 250 300 300
Between the auxiliary contacts (Vac) 400 400 250 300 300
Rated operational current
AC-15 220/240V I
380/415V I
500V I
1
DC-13
DC13 L/R <15 ms
Contacts in series—voltage:
1—24V 10
1—60V
2—60V 10 10 2.5 2.5
1—110V 3 3
3—110V 6 6 1.5 1.5
1—220V 1 1
3—220V
DC13 L/R <50 ms
Contacts in series—voltage:
3—24V 4
3—60V 4
3—110V 2
3—220V 1
Control circuit reliability
= 24 Vdc, U
(at U
e
Conventional thermal current (I
Short-circuit rating without welding
Maximum overcurrent protective device
220/240V–XTPR Frame B 4 4 4
380/415V–XTPR Frame B 4 4 4
Short-circuit protection, max. fuse
500V (A gG/gL) 10 10 6 6 6
500V (A fast) 10 10
Current heat losses at load of I
AC operated (W) 0.3 0.3 0.2 0 .2
DC operated (W) 0.3 0.3 0.3 0 .3
Note
1
Making and breaking conditions to DC13, time constant as stated.
e
e
e
= 17, I
min
) Vac 6000 6000 6000 6000 6000
imp
) Vac 690 690 600 690 690
i
) Vac 690 500 400 600 600
e
= 5.4 mA)
min
) 16 16 6 10 10
th
th
Yes Yes No Yes Yes
6 6 Please inquire 6 4
4 3 Please inquire 3 2
1.5 1.5 1.5
10
66
55
——
——
——
——
Failure rate = <10 in 100 million operations
–8
, <1 failure
———
Failure rate = <10–8, <1 failure
2.5 2.5
0.5 0.5
——
——
——
——
in 100 million operations
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
1
V5-T1-13
IEC Contactors and Starters
1.1
Relays and Timers, continued
1
Description XTRE XTCEXFAC_ XTCEXTE_ XTRM XTMCXFA_
Magnet Systems
1
Pickup and dropout values
AC operated
1
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz (pickup x U
1
Dual-frequency coil 50/60 Hz (pickup x U
1
DC operated
Pickup voltage (pickup x Uc) 0.8–1.1 0.7–1.2 0.85–1.3
1
At 24V: without auxiliary contact module (40°C) (pickup x U
Power consumption
1
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pickup VA 24 25
1
Pickup W 19 22
1
Sealing VA 3.4 2 4.6
Sealing W 1.2 1.8 1.3
1
Dual-frequency coil 50/60 Hz at 50 Hz
Pickup VA 27 30
1
Pickup W 22 26
1
Sealing VA 4.2 5.4
Sealing W 1.4 1.6
1
Dual-frequency coil 50/60 Hz at 60 Hz
Pickup VA 25 29
1
Pickup W 21 24
Sealing VA 3.3 3.9
1
Sealing W 1.2 1.2
1
DC operated
Pull-in = sealing (W) 3 2.6
1
Duty factor (% DF) 100 100 100
Switching times at 100% U
1
AC operated closing delay (ms)
AC operated NO contact opening delay (ms)
1
AC operated with auxiliary contact module, max. closing delay (ms)
1
DC operated closing delay (ms)
1
DC operated NO contact opening delay (ms)
DC operated with auxiliary contact module, max. closing delay (ms)
1
Note
1
1
Smoothed DC or three-phase bridge rectifier.
)
c
1
XT IEC Power Control
) 0.8–1.1 0.85–1.1
c
(approximate values)
c
0.8–1.1 0.85–11 0.8–1.1
) 0.7–1.3 0.7–1.3
c
<
21 14–21
<
18 8–18
—— — 4545
<
31 26–35
<
12 15–25
—— — 7070
1
1
1
1
1
1
1
V5-T1-14
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
Component lifespan (operations) I
e
= Rated operational current
AC-15
240 V
0.01
0.050.02
20.1
0.5
152.0
10 A
20
10
5
2
1
0.5
0.2
0.1
10
6
I
e
L R
DC-13
24 V
= 50 ms
Component lifespan (operations) I
e
= Rated operational current
0.01
0.050.02
20.1
0.5
150.2
10 A
20
10
5
2
1
0.5
0.2
0.1
10
6
I
e
4.5
4.5
3.30
0
1.0
2.9
2.9
2.10
0
0.7
4.5
4.5
3.20
0
1.6
2.9
2.9
2.30
0
0.7
4.5
4.5
2.00
0
2.8
2.9
2.9
1.10
0
1.9
Normally open contact
XTRE_ — AC Operation
XTCEXFALC_ — AC Operation
XTCEXFAC_ — AC Operation
Normally closed contact
Normally open contact
Normally closed contact
Normally open contact (early make)
Normally closed contact (late make)
Normally open contact
XTRE — DC Operation
XTCEXFALC_ — DC Operation
XTCEXFAC_ — DC Operation
Normally closed contact
Normally open contact
Normally closed contact
Normally open contact (early make)
Normally closed contact (late make)
XT IEC Power Control
1.1
Control Relays—Characteristic Curves
XTRE (AC-15)
The diagrams show the closing and opening travel of the contact of the contactor relays and auxiliary contacts at no load. Tolerances are not taken into consideration.
Contact Travel Diagrams
XTRE
XTRE (DC-13)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Note
1
Making and breaking conditions to DC-13, time constant as stated.
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
V5-T1-15
1
1
1
1
1
1.1
LED
A1-A2
15-18
t
A1-A2
15-18
OFFONOFF
LED
A1-A2 15-18
t
LED
LED
tttt
A1-A2 15-18
LED
A1-A2
15-18
0.5 s
t
17-18
ttu
A1-A2
17-28
Power LED
LED LED
45
[1.77]
58
[2.28]
52 – 54
[2.05] – [2.13]
5.5 [.22]
52 – 54
[2.05] – [2.13]
45
[1.77]
62.5
[2.46]
IEC Contactors and Starters
XT IEC Power Control
Flow Diagrams—Electronic Timers, XTMT Mini Timers
1
On-Delay
1
1
1
ON-OFF Function
1
1
1
Fleeting Contact on Energization
1
1
1
1
Flashing, Pulse Initiating
1
1
1
Pulse Generating
1
Dimensions
Approximate Dimensions in mm [in.]
Mini Contactor Relays
Mini Control Relay XTRM
XTRM Mini Control Relay with IP40 XTMCX Shroud
43
[1.69]
58
[2.28]
45
[1.77]
XTRM Mini Control Relay with RC or Varistor Suppressor
65.3
[2.57]
45
[1.77]
1
1
1
Star-Delta (Wye-Delta) Timer
1
Star-Delta
1
1
1
1
Rating Data
1
Rating Data for Approved Types
1
Pilot Duty General Use
Control Relays—XTMR
1
A600, P300 10A–600 Vac
1
Timers—XTMT, XTTR
B300 6A–250 Vac
1
1
1
V5-T1-16
Volume 5—Motor Control and Protection CA08100006E—August 2018
0.5A–250 Vdc
XTRM Mini Control Relay with XTMCXFA Auxiliary Contact
M4
58
[2.28]
45
[1.77]
83 – 86
[3.27] – [3.39]
50
[1.97]
35
[1.38]
IEC Contactors and Starters
18
[.71]
45
[1.77]
6.5
[.26]
75
[2.95]
117
[4.61]
68
[2.68]
45
[1.77]
18
[.71]
26.4
[1.04]
52.3
[2.06]
45
[1.77]
36
[1.42]
6.5
[.26]
75
[2.95]
125
[4.92]
68
[2.68]
38
[1.50]
25
[.98]
70
[2.76]
45
[1.77]
6.5
[.26]
75
[2.95]
45
[1.77]
68
[2.68]
90
[3.54]
XT IEC Power Control
1.1
Approximate Dimensions in mm [in.]
Control Relays
Control Relay XTRE with XTCEXFA Auxiliary Contact
Control Relay with Spring Cage Terminals XTREC with XTCEXFA Auxiliary Contact
Electronic Timer Module XTCEXTE
Control Relay XTRE with XTCEXMLB Mechanical Interlock
Coil Suppressors for Use with XTRE Control Relays
Approx.
28
32 [1.26]
[1.10]
25.9
[1.02]
19.2 [.76]
25
[.98]
9
[.35]
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
V5-T1-17
1.1
XTMC Miniature Contactor
An Eaton Green Solution
IEC Contactors and Starters
XT IEC Power Control
1
1
1
1
1
1
1
1
1
1
1
Miniature Controls
Product Description
1
Eaton’s new line of XT
1
miniature controls includes non-reversing and reversing mini contactors, mini overload
1
relays and snap-on accessories. A wide range of
1
applications is possible, including small electrical
1
motors from fractional to 5 hp (460 Vac) or up to 4 kW (400 Vac).
1
Application Description
1
Due to its compact size, the XT line of mini controls is
1
best suited to be applied in light-duty loads, such as
1
hoisting, packaging, material handling, heating, lighting and automation systems. XT mini
1
contactors are a particularly compact, economic and
1
environmentally friendly solution wherever control
1
of small motors or loads is required.
1
1
Features
Mini Contactors—Types XTMC and XTMF, 6–9A
AC control from 12V to 55
0V 50 Hz, 600V 60 Hz
DC control from 1
2V to 220V
Reversing or non-reversing
Three- and four-pole co
nfigurations
Three-pole XTMC
Four-pole XTMF
Panel or DIN rail mounting
IP20 finger and back-of­hand proof
Low noise operation
High degree of climatic proo
fing
Large ambient temperature range –25° to 50°C [–13
22°F]
1
° to
Contents
Description Page
Relays and Timers . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-3
Miniature Controls
Catalog Number Selection . . . . . . . . . . . . . . . . V5-T1-19
Product Selection . . . . . . . . . . . . . . . . . . . . . . . V5-T1-20
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-24
Technical Data and Specifications . . . . . . . . . . . V5-T1-27
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-32
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-34
Contactors and Starters . . . . . . . . . . . . . . . . . . . . V5-T1-35
Thermal Overload Relays . . . . . . . . . . . . . . . . . . . V5-T1-130
C440/XT Electronic Overload Relay . . . . . . . . . . . V5-T1-143
Manual Motor Protectors . . . . . . . . . . . . . . . . . . . V5-T1-159
Combination Motor Controllers . . . . . . . . . . . . . . . V5-T1-193
XT Electronic Manual Motor Protector . . . . . . . . . V5-T1-219
EMS—Electronic Motor Starter . . . . . . . . . . . . . . V5-T1-232
XT DC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-234
Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . V5-T1-236
Standards and Certifications
Mini Overload Relays— Bimetallic
Type XTOM
Phase failure sensitivity Direct mount to XTMC and
XT
MF mini contactors Trip Class 10 11 s e t t i ng s t o co v e r
0.1 to 12A Ambient temperature
com
pensated –5
23° to 122°F]
[ Manual and automatic
rese
t by selector switch
One make (NO) or one brea
k (NC) auxiliary contact
as standard Test/Off button Trip-free release
° to 50°C
IEC EN 60947
CE approved
UL
CSA
CCC
1
1
1
1
1
V5-T1-18
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
Type
MC = Three-pole FVNR
mini IEC contactor
MF = Four-pole FVNR mini
IEC contactor
MR = Three-pole FVR mini
IEC contactor
Designation
XT = XT IEC power control
Current Rating,
AC-3
XTMC 6 = 6.6A 9 = 8.8A
XTMF 9 = 8.8A
Integral Auxiliary Contact
01 = 1NC 10 = 1NO
Coil Codes
A = 110V 50 Hz, 120V 60 Hz B = 220V 50 Hz, 240V 60 Hz F = 230V 50 Hz T = 24V 50/60 Hz TD = 24 Vdc C = 415V 50 Hz, 480V 60 Hz D = 550V 50 Hz, 600V 60 Hz E = 208V 60 Hz G = 190V 50 Hz, 220V 60 Hz H = 240V 50 Hz, 277V 60 Hz
L = 380V 50 Hz, 440V 60 Hz N = 400V 50 Hz P = 380V 60 Hz R = 12V 50/60 Hz W = 42V 50 Hz, 48V 60 Hz Y = 48V 50 Hz AD = 120 Vdc BD = 220 Vdc RD = 12 Vdc WD = 48 Vdc
Frame Size
A = 45 mm mini
XT MC 6 A 10 A
Type
OM = Mini overload relay
Trip Class
C1 = Class 10A
Designation
XT = XT IEC power control
Frame Size
A = 45 mm mini
Overload Release
P16 = 0.1–0.16A P24 = 0.16–0.24A P40 = 0.24–0.4A P60 = 0.4–0.6A 001 = 0.6–1A 1P6 = 1–1.6A
2P4 = 1.6–2.4A 004 =2.4–4A 006 = 4–6A 009 = 6–9A 012 = 9–12A
XT OM P16 A C1
XT IEC Power Control
1.1
Instructional Leaflets
Pub51219 XTMC, XTMF Mini Contactors, XTRM Mini
Control Relay and Accessories
Pub51243 XTOM Mini Overload Relays
Pub51206 Mini Reversing Link Kits
MN03402002E XTOM Mini Overload Relays Installation
and User Manual
Catalog Number Selection
XT IEC Miniature Contactors
1
1
1
1
1
1
1
1
1
1
1
1
1
1
XT IEC Miniature Overload Relays
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-19
IEC Contactors and Starters
XTMC_
1.1
Product Selection
1
Full Voltage Non-Reversing Miniature Contactors
1
1
1
1
1
1
XT IEC Power Control
Maximum UL Ratings—Single-Phase and Three-Phase
Horsepower Ratings Single-Phase Three-Phase 115V 200V 230V 200V 230V 460V 575V
1/43/411-1/22333 1NO XTMC6A10_
1/43/411-1/22333 1NC XTMC6A01_
1/211-1/223553 1NO XTMC9A10_
1/211-1/223553 1NC XTMC9A01_
1/211-1/223554 XTMF9A00_
Number of Power Poles
Auxiliary Contacts
Screw Terminal Catalog Number
1
1
1
1
1
1
1
Magnet Coil Suffix
Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code
1
110V 50 Hz, 120V 60 Hz A 415V 50 Hz, 480V 60 Hz C 380V 60 Hz P 120 Vdc AD
1
220V 50 Hz, 240V 60 Hz B 550V 50 Hz, 600V 60 Hz D
230V 50 Hz F 208V 60 Hz E 42V 50 Hz, 48V 60 Hz W 12 Vdc RD
1
24V 50/60 Hz T 190V 50 Hz, 220V 60 Hz G 48V 50 Hz Y 48 Vdc WD
24 Vdc TD
1
380V 50 Hz, 440V 60 Hz L ——— —
1
Notes
IEC Utilization Categories, see Page V5-T1-249. AC-1: Non-inductive or slightly inductive loads.
1
AC-3: Squirrel cage motors—starting, switching of motors during running. AC-4: Squirrel cage motors—starting, plugging, inching.
1
1
Underscore (_) indicates magnetic coil suffix required.
2
With DC operation: Integrated diode resistor combination, coil rating 2.6W.
3
1
XTMF four-pole contactor not available with “D” or “R” coil voltage suffix.
Maximum IEC Ratings AC-3
Operational Current AC-3 Amp Rating 380/400V
6.6 20 1.53333 1NO XTMC6A10_
6.6 20 1.53333 1NC XTMC6A01_
8.8 20 2.24443 1NO XTMC9A10_
8.8 20 2.24443 1NC XTMC9A01_
8.8 20 2.24444 XTMF9A00_
2
Conventional Free Air Thermal Current AC-1 at 50°C
240V 50 Hz, 277V 60 Hz H ——— —
Three-Phase Motors 50–60 Hz 220–
380–
240V
400V 550V
3
12V 50/60 Hz R
660/ 690V
Number of Power Poles
3
Auxiliary Contacts
220 Vdc BD
Screw Terminal Catalog Number
1
1
1
1
1
1
1
1
1
1
V5-T1-20
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
XTMR_
XT IEC Power Control
1.1
Full Voltage Reversing Miniature Contactors
1
Maximum UL Ratings—Single-Phase and Three-Phase
Horsepower Ratings Single-Phase Three-Phase Spare Auxiliary Contacts 115V 200V 230V 200V 230V 460V 575V K1M K2M
1/4 3/4 1 1-1/2 2 3 3 XTMR6A21_
1/211-1/22355 XTMR9A21_
63
64
63
64
63
64
63
64
Catalog Number
12
1
1
1
1
1
1
Maximum IEC Ratings AC-3
Three-Phase Motors 50–60 Hz
Operational Current AC-3 Amp Rating 380/400V
6.6 20 1.5333 XTMR6A21_
8.8 20 2.2444 XTMR9A21_
Conventional Free Air Thermal Current AC-1 at 50°C
220/ 230/ 240V
380/ 400/ 440V 500V
660/ 690V
Spare Auxiliary Contacts K1M K2M
63
64
63
64
63
64
63
64
Catalog Number
12
1
1
1
1
1
1
Magnet Coil Suffix
Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code
110V 50 Hz, 120V 60 Hz A 415V 50 Hz, 480V 60 Hz C 380V 60 Hz P 120 Vdc AD
220V 50 Hz, 240V 60 Hz B 550V 50 Hz, 600V 60 Hz D
230V 50 Hz F 208V 60 Hz E 42V 50 Hz, 48V 60 Hz W 12 Vdc RD
24V 50/60 Hz T 190V 50 Hz, 220V 60 Hz G 48V 50 Hz Y 48 Vdc WD
24 Vdc TD
380V 50 Hz, 440V 60 Hz L ——— —
Notes
IEC Utilization Categories, see Page V5-T1-249. AC-1: Non-inductive or slightly inductive loads. AC-3: Squirrel cage motors—starting, switching of motors during running. AC-4: Squirrel cage motors—starting, plugging, inching.
1
Underscore (_) indicates magnetic coil suffix required. See Magnet Coil Suffix table above.
2
The factory-installed reversing mini contactor includes (2) XTMC…01 contactors, (2) XTMCXFA20 2NO front-mount auxiliary contacts (1) XTMCXRL reversing link kit and (1) XTMCXML mechanical interlock.
3
XTMF four-pole contactor not available with “D” or “R” coil voltage suffix.
2
240V 50 Hz, 277V 60 Hz H ——— —
3
12V 50/60 Hz R
3
220 Vdc BD
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
1
1
1
1
1
1
V5-T1-21
IEC Contactors and Starters
XTMC_
2122313253
54
2122313253
54
1.1
Star-Delta (Wye-Delta) Miniature Contactors
1
XT IEC Power Control
1
1
1
Maximum Current UL Ratings—Single-Phase and Three-Phase
Horsepower Ratings Single-Phase Three-Phase 115V 200V 230V 200V 230V 460V 575V
1/211-1/22357-1/230 K1M main contactorXTMC9A10_
1
1
1
1
1
1
1
Maximum IEC Ratings AC-3
Horsepower Ratings Three-Phase Motors 50–60 Hz 220/230/240V 380/400/440V 500V
4 5.5 5.5 30 K1M main contactor XTMC9A10_
1
1
1
1
Mini Overload Relay Settings (A)
Setting Starting
1
x 0.58
A: I
N
Motor protection in the Y and delta configurations.
1
B: I
x 1
N
Only partial motor protection in star position
1
C: I
x 0.58
N
Motor not protected in star position.
1
Timing relay set to approximately 10 sec.
Notes
1
Depending on the coordination type required (that is, Type 1 or Type 2) it must be established whether the fuse protection and the input wiring for the main and delta contactors are to be
1
common or separate.
1
1
Operating frequency: 30 starts/hour. See Magnet Coil Suffix table on following page.
2
Underscore (_) indicates magnet coil suffix required.
<
15 sec
15–40 sec
>40 sec
1
Maximum Changeover Time (sec.)
1
Maximum Changeover Time (sec.)
Spare Auxiliary Contacts K1M
Spare Auxiliary Contacts K1M
Component Description Catalog Number
K1M auxiliary contact XTMCXFC22
K5M delta contactor XTMC9A01_
K3M star contactor XTMC9A10_
K3M auxiliary contact XTMCXFC02
K1T timing relay XTTR6A60S51B
Component Description Catalog Number
K1M auxiliary contact XTMCXFC22
K5M delta contactor XTMC9A01_
K3M star contactor XTMC9A10_
K3M auxiliary contact XTMCXFC02
K1T timing relay XTTR6A60S51B
2
2
1
1
1
1
1
1
1
1
V5-T1-22
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
XTOM_
6429896
97 95
XT IEC Power Control
1.1
Magnet Coil Suffix
Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code Coil Voltage Suffix Code
110V 50 Hz, 120V 60 Hz A 415V 50 Hz, 480V 60 Hz C 400V 50 Hz N 120 Vdc AD
220V 50 Hz, 240V 60 Hz B 550V 50 Hz, 600V 60 Hz D 380V 60 Hz P 220 Vdc BD
230V 50 Hz F 208V 60 Hz E 12V 50/60 Hz R 12 Vdc RD
24V 50/60 Hz T 190V 50 Hz, 220V 60 Hz G 24V 50 Hz U 48 Vdc WD
24 Vdc TD
380V 50 Hz, 440V 60 Hz L 48V 50 Hz Y ——
Mini Overload Relays
1
Mini Overload Relays
Overload Release I
t
0.1–0.16A 10A 1NO-1NC 20 0.5 15 XTOMP16AC1
0.16–0.24A 10A 1NO-1NC 20 1 15 XTOMP24AC1
0.24–0.4A 10A 1NO-1NC 20 2 15 XTOMP40AC1
0.4–0.6A 10A 1NO-1NC 20 2 15 XTOMP60AC1
0.6–1A 10A 1NO-1NC 20 4 15 3 XTOM001AC1
1–1.6A 10A 1NO-1NC 20 6 15 6 XTOM1P6AC1
1.6–2.4A 10A 1NO-1NC 20 6 15 6 XTOM2P4AC1
2.4–4A 10A 1NO-1NC 20 15 15 XTOM004AC1
4–6A 10A 1NO-1NC 20 15 20 XTOM006AC1
6–9A 10A 1NO-1NC 20 15 35 XTOM009AC1
9–12A 10A 1NO-1NC 45 XTOM012AC1
Notes
1
With DC operation: Integrated diode resistor combination, coil rating 2.6W.
2
Short-circuit protection: Observe the maximum permissible fuse of the contactor with direct device mounting. See MN03402002E for more information.
3
When fitted directly to the contactor, a clearance of at least 5 mm is required between the overload relays.
240V 50 Hz, 277V 60 Hz H 42V 50 Hz, 48V 60 Hz W ——
23
Short-Circuit Protection (A)
Tri p Class
Contact Sequence
Contact Configuration
Typ e 1 Coordination, gG/gL
Typ e 2 Coordination, gG/gL
Circuit Breaker
CEC/NEC Fuse
Catalog Number
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
1
1
1
1
1
1
1
1
1
1
1
V5-T1-23
IEC Contactors and Starters
21
223132
54
53
61
62
515261
62
71
72
82
81
58
57
65
66
717283
84
1.1
Accessories
1
Auxiliary Contacts
1
Front-mounted snap-on auxiliary contacts for mini contactors are available with screw terminals in a variety of contact configurations. Auxiliary contact modules are standard with interlocked opposing
1
contacts, except in the case of early-make or late-break contacts.
1
Front-Mount Auxiliary Contacts for Use with Mini Contactors
Conventional Free Air Thermal Current,
1
1
1
1
= Ie, AC-1 in Amps
I
th
10 2NC 5 XTMCXFC02
10 1NO-1NC 5 XTMCXFD11
XT IEC Power Control
Contact Configuration Contact Sequence
212233
Pkg. Qty.
1
Screw Terminal Catalog Number
1
10 2NO-2NC 5 XTMCXFC22
1
1
10 2NC 5 XTMCXFA02
1
21
223132
1
10 1NO-1NC 5 XTMCXFA11
1
34
43
53
54
44
51
61
62
52
1
10 2NO 5 XTMCXFA20
1
1
10 4NC 5 XTMCXFA04
53
546364
1
1
10 1NO-3NC 5 XTMCXFA13
536171
81
1
62
61
82
72
717283
1
10 2NO-2NC 5 XTMCXFA22
54
53
1
62
54
1
10 3NO-1NC 5 XTMCXFA31
53 61
84
83
1
54
627374
84
1
10 4NO 5 XTMCXFA40
1
1
10 1NO-1NC
1NO
-1NC
E
L
53
63 73
83
64
54
84
74
5 XTMCXFAL22
1
2
1
1
Notes
1
Orders must be placed in multiples of package quantity listed.
2
One early-make contact (NOE), one late-break contact (NCL).
V5-T1-24
Volume 5—Motor Control and Protection CA08100006E—August 2018
IEC Contactors and Starters
XTMCXR_
XTMC Relay with Installed Suppressor
XTMCX_
XTMC Relay with Installed Suppressor
XTMCXML
XT IEC Power Control
1.1
Suppressors
RC Suppressor
Voltage
24–48 XTMC6A_,
48–130 XTMC6A_,
110–250 XTMC6A_,
Varistor Suppressor
Voltage
24–48 XTMC6A_,
48–130 XTMC6A_,
110–250 XTMC6A_,
380–415 XTMC6A_,
1
For Use with…
XTMC9A_
XTMC9A_
XTMC9A_
For Use with…
XTMC9A_
XTMC9A_
XTMC9A_
XTMC9A_
1
1
1
1
Circuit Symbol
A1
A2
Pkg.
2
Qty.
10 XTMCXRSW
10 XTMCXRSA
Catalog Number
1
10 XTMCXRSB
1
1
1
1
3
Pkg.
Circuit Symbol
A1
2
Qty.
10 XTMCXVSW
Catalog Number
1
1
1
A2
10 XTMCXVSA
1
10 XTMCXVSB
1
10 XTMCXVSN
1
Mechanical Interlock
Mechanical Interlock
Pkg.
Description
Mechanical interlock 5 XTMCXML
Notes
For two contactors with AC or DC operated magnet system that are horizontally or vertically mounted, the distance between contactors is 0 mm and the mechanical lifespan is 2.5 x 10
1
For AC operated contactors, 50/60 Hz. Note dropout delay.
2
Orders must be placed in multiples of package quantity listed.
3
For AC operated contactors, 50/60 Hz. DC operated contactors have integrated varistor suppressors.
Qty.
2
Catalog Number
6
operations.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 5—Motor Control and Protection CA08100006E—August 2018
1
V5-T1-25
Loading...